333.190 Inspection of purchased commodities; material or ...
THE NEVADA STATE PURCHASING DIVISION IS SOLICITING BIDS FOR
3,000 GALLON WATER TENDER
INVITATION TO BID NO. 8474
F.O.B. Conservation and Natural Resources/Nevada Division of Forestry, State Headquarters, 2478 Fairview Drive, Carson City, NV 89701
Release Date: 08/31/16
Vendor Questions Due: 09/13/16
Deadline for Submission and Opening Date and Time: 09/29/16 @ 2:30 PM PT
Requisition No. 706-27700
For additional information or to obtain a copy of this Invitation to Bid, please contact:
Heather Moon, Buyer III
(775) 684-0179
(TTY for the Hearing Impaired: 1-800-326-6868 and ask the relay agent to dial (775) 684-0179)
See page 41, for instructions on submitting bids.
Company Name: ____________________________________________________________________
Contact Name: _________________________________________Title:________________________
Address: __________________________________________________________________________
City: ___________________________________________ State: ___________Zip: ______________
Telephone (_____) __________________________ Fax (_____) ____________________________
E-Mail Address: _____________________________________________________________________
While there are no set asides in the State of Nevada or preferences for Minority Business Enterprise, Women Business Enterprise and Small Business, we encourage those vendors to compete for state business at every opportunity and we make every effort to contact these businesses when opportunities arise, therefore if it is your judgment that your business fits within these categories, please check appropriate boxes.
Minority Owned Women Owned Small Business
Page 1 of 69
TABLE OF CONTENTS
1. PROJECT OVERVIEW 3
2. ACRONYMS/DEFINITIONS 3
3. ITEM SPECIFICATIONS 4
4. PAYMENT 40
5. BID SUBMITTAL INSTRUCTIONS 41
6. BID SOLICITATION, EVALUATION AND AWARD PROCESS 42
7. TERMS AND CONDITIONS FOR PURCHASE OF GOODS 44
ATTACHMENT A 51
In accordance with NRS 333.350(1), a contract may be awarded for separate items, portions or groups of items in the best interest of the State, as required.
Prospective vendors are advised to review Nevada’s ethical standards requirements, including but not limited to, NRS 281A.
1. PROJECT OVERVIEW
The purpose of this solicitation is to obtain competitive pricing for a one-time purchase of one (1) 3,000 Gallon Water Tender for the Nevada Division of Forestry. As a condition of this award, vendor is required to deliver any vehicle(s) specified herein to any government entity using any award or contract that results from this solicitation through a licensed Nevada vehicle dealer, which will then be considered a joint submittal, or be a licensed Nevada vehicle dealer prior to the submission and opening date of the proposal pursuant to Nevada Revised Statute 482. Vendors must return two (2) copies of their entire bid document submission to State Purchasing. Failure to comply with this requirement could be grounds for non-acceptance of the bid.
The awarded vendor shall accept full responsibility and liability in the transport of the agency’s vehicle, relieving the State of Nevada of any loss, liability or claim whatsoever incurred while the vehicle is in the vendor’s custody. Following delivery of the completed vehicle, the Nevada Division of Forestry shall thoroughly inspect the vehicle for total compliance with the specifications. Acceptance shall not be accomplished until said equipment is in exact compliance with all requirements as specified.
2. ACRONYMS/DEFINITIONS
For the purposes of this Invitation to Bid, the following acronyms/definitions will be used:
Awarded Vendor/ The organization or individual that is awarded and has an approved contract or purchase
Contractor order with the State of Nevada for the goods identified in this Invitation to Bid.
Bidder/Vendor Organization or individual submitting a bid in response to this Invitation to Bid.
Division Department of Conservation and Natural Resources, Division of Forestry
FOB Destination Free on Board to the destination. Requires the seller to, at its own expense and risk, transport the goods to the destination and there tender delivery of them in the manner provided in NRS 104.2503. See NRS 104.2319(1)(b); UCC 2-319(1).
Goods As defined in NRS 104.2105, and as specifically identified in this Invitation to Bid.
ITB Invitation to Bid. A written statement which sets forth the requirements and specifications of a contract to be awarded by competitive selection. See NRS 333.020(4).
Lowest Responsible Person or firm (company/organization) that conforms in all material respects to the
Bidder/Vendor specifications within the invitation to bid and offers the lowest cost after all factors have been considered. See NRS 333.340
MSRP Manufacturer’s Suggested Retail Price
NAC Nevada Administrative Code
NOA Notice of Award
NRS Nevada Revised Statutes
Proprietary Any trade secret or confidential business information that is contained in a bid Information submitted on a particular contract. See NRS 333.020(5)(a); NRS 333.333.
Public Record All books and public records of a governmental entity, the contents of which are not otherwise declared by law to be confidential must be open to inspection by any person and may be fully copied or an abstract or memorandum may be prepared from those public books and public records. See NRS 333.333; NRS 600A.030(5).
Purchase Order Buyer-generated document that authorizes a purchase transaction. It sets forth the descriptions, quantities, prices, discounts, payment terms, date of performance or shipment, other associated terms and conditions, and identifies a specific seller. When accepted by the seller, it becomes a contract binding on both parties; also called order.
Subcontractor Third party, not directly employed by the vendor, who will provide goods and/or services identified in this ITB. This does not include third parties who provide support or incidental services to the vendor.
Shall/Must/Will Indicates a mandatory requirement. Failure to meet a mandatory requirement may result in the rejection of a bid as non-responsive.
Should/May Indicates something that is recommended but not mandatory. If the vendor fails to provide recommended information, the State may, at its sole option, either ask the vendor to provide the information or evaluate the bid without the information.
State The State of Nevada and any agency identified herein.
Trade Secret Information including, without limitation, a formula, pattern, compilation, program, device, method, technique, product, system, process, design, prototype, procedure, computer programming instruction or code that derives independent economic value, actual or potential, from not being generally known to, and not being readily ascertainable by proper means by the public or any other person who can obtain commercial or economic value from its disclosure or use, and is the subject of efforts that are reasonable under the circumstances to maintain its secrecy. See NRS 600A.030(5).
UCC Uniform Commercial Code
3. ITEM SPECIFICATIONS
Unless otherwise specified in this ITB, reference to a specific manufacturer or a specific product or model in the bid specifications does not restrict bidders to that manufacturer, product or model. This method is used to indicate the functional requirements (e.g., type, design, characteristics, quality) of the article desired. Bids may be considered on other manufacturer’s products or other models determined by the Purchasing Division to be the functional equivalent of the product or model referenced.
DESCRIPTION
This bid solicitation is for the complete construction of (1) truck body and water tank to be designated as a "3,000 gallon Water Tender”, and when mounted to an appropriate cab and chassis, will be described as a Nevada Division of Forestry "3,000 gallon Water Tender.” This body will be installed on a diesel-powered cab and chassis of approximately 142.50" cab-axle measurement, with a 226" wheelbase, and the axle to the vehicle frame will be 96”. Use of the vehicle includes responding to emergency wildland interface incidents, natural disasters, and conservation project worksites that requires driving on extensive mountain roads and forest truck trails that will impose extreme stress on all components. The safety of the driver and vehicle is to be considered in all phases of construction. The certification of the vehicle described in this specification must meet or exceed all requirements of the NFPA 1901 & 1906, latest editions, except where otherwise noted. The final completed vehicle certification is the responsibility of the contractor constructing the water tender as described herein.
SCOPE
These specifications and a prototype 3,000 gallon Water Tender that are used for Wildland Fire Suppression are a job description to be utilized by the contractor to construct one (1) complete, working, 3,000 gallon Water Tender based under a general specification. This job description requires the highest quality, state-of-the-art components including fire pump, plumbing, wiring, lighting, and general construction items for the body; all of which is required of the finished product provided by this solicitation and subsequent purchase order. Variations between the specifications, and the received cab and chassis may exist in "Cab to Axle dimension", frame construction, and basic component location. The contractor shall make allowances if these differences exist, so that component interface and body clearances can be maintained. If the cab and chassis are delivered with accessories or fittings that prevent the mounting of NDF specified components, i.e., cab roof horns, etc. then such items will be removed and reinstalled elsewhere after being approved by the NDF Fleet Manager, and all the applicable body work is accomplished by the contractor.
GENERAL PROVISIONS
PRECONSTRUCTION CONFERENCE
A pre-construction conference will be held at the Division of Forestry’s facility between the contractor and the designated NDF representative within 15 days after formal notification of receiving the successful bid (NOA). This conference will be held prior to the start of any construction. The purpose of this meeting is to review the specifications and any variations in the chassis. This meeting can be held via conference call and video monitoring systems.
PRODUCTION / DELIVERY SCHEDULE
Each bidder shall submit a production and delivery schedule covering the contract as if they are the successful contractor. Bidders must state when (in calendar days after the PO is issued) the unit will be completed and delivered, thus completing the contract. The completed unit is to be delivered by the contractor to the NDF Fleet Operations Facility in the Carson City area for the final acceptance and operational inspection no later than June 15th 2017.
WARRANTY COMPLY _____YES NO_____
The successful contractor shall warranty the Water Tender body and fire pump system, assembled or manufactured, to be free from defects in material, and workmanship for ten (10) years, unless otherwise noted, from the date the unit is placed in field service by the Nevada Division of Forestry.
This warranty shall not apply to the following:
• Any component parts or trade accessories such as chassis, engines, tires, pumps, valves, signaling devices, batteries, electric lights, bulbs, alternators, and all other installed equipment and accessories, in as much as they are usually warranted separately by their respective manufacturers, or are subject to normal wear and tear.
• Failures resulting from the apparatus being operated in a manner or for a purpose not recommended by the apparatus manufacturer.
• Loss of time or use of the apparatus, inconvenience or other incidental expenses.
• Any apparatus which has been repaired or altered outside of the apparatus manufacturer's factory in any way that affects its stability, or which has been subject to misuse, negligence, or accident.
The general Water Tender warranty will ensure that the vehicle has been manufactured to the contract specifications, and will be free from defects in material and workmanship that may appear under normal use and service within the warranty period. The contractor will repair or replace said defective parts and/or materials at no cost to the NDF, and the work is to be done at the contactors authorized service facility that is the closest to the in service location of the vehicle.
Any warranty issues prior to the In-Service date will be at the contractor's expense. This warranty shall also include any and all costs if it is necessary to move the unit back to the contractor's place of business, or authorized repair facility for warranty repairs. The commercial chassis and all the OEM installed components shall be covered by the vehicle manufacturer's warranty. A copy of this warranty must accompany the bid. The unit will be maintained and repaired by the NDF’s Fleet Operations Staff according to the NDF's Fleet Operations Guidelines.
The NDF's Preventive Maintenance Program shall be considered sufficient to meet all warranty requirements. Any questions concerning the maintenance program should be directed to the NDF's Fleet Operations Manager. Forestry fire apparatus operates over a large portion of the State of Nevada, thus making it imperative that the vehicle be repaired throughout the State, and the bidder must indicate by letter the procedure to be followed by the NDF in handling items and conditions covered by the warranty or guarantee. This information must accompany the bid.
Specify General Water Tender Mfr. Warranty _____________________________________
CORROSION LIMITED WARRANTY COMPLY _____YES NO_____
The bidder, shall warrant only to the original purchaser and the first purchaser who places the motor vehicle in service that the apparatus body manufactured by the bidder (the "body"), under normal use and with normal maintenance, will remain free from corrosion for a period of ten (10) years from the date that the motor vehicle was first placed in service. A body shall be considered to have "corrosion defects" if it is found by the bidder to have perforation caused by corrosion under normal use and with normal maintenance.
Specify Corrosion Warranty _____________________________________
STAINLESS STEEL PLUMBING WARRANTY COMPLY _____YES NO_____
The bidder shall warrant that all stainless steel piping used in the construction of the fire apparatus water/foam plumbing systems against defects and workmanship provided the apparatus is used in a normal and reasonable manner. This warranty is extended only to the original user-purchaser for a period of ten (10) years from the date of delivery.
Specify Stainless Steel Plumbing Warranty _____________________________________
BALL VALVE WARRANTY COMPLY _____YES NO_____
The bidder shall warrant that all ball valves used in the construction of the fire apparatus water/foam plumbing systems against defects and workmanship provided the apparatus is used in a normal and reasonable manner. This warranty is extended only to the original user-purchaser from the date of delivery.
Specify Ball Valve Warranty _____________________________________
MID-SHIP FIRE PUMP WARRANTY COMPLY _____YES NO_____
The mid-ship mounted fire pump that is specified to be supplied with this apparatus shall be warranted by the manufacturer for a period from the date that the apparatus is put into service. The manufacturer shall repair, at no cost to the purchaser, any problems caused by defective materials and/or workmanship. The warranty shall cover the reasonable costs of removing the fire pump from the apparatus and reinstalling it after the completion of the covered warranty repairs, but shall not cover any liability for the loss of service or downtime costs of the apparatus. The provisions of this warranty shall be provided in the delivery documentation.
Specify Main Fire Pump Mfr. Warranty _____________________________________
WATER TANK WARRANTY COMPLY _____YES NO_____
The stainless steel water tank that is specified to be supplied with this apparatus that is externally mounted of the truck body shall be warranted by the water tank manufacturer for a fifteen (15) year period from the date that the apparatus is put into service. The manufacturer shall repair, at no cost to the purchaser, any problems caused by defective materials and/or workmanship. The tank manufacturer shall make an effort to begin the process to repair the tank within 48 hours following initial notification of a covered defect. Should the need arise, the warranty shall cover the reasonable costs of removing the water tank from the apparatus and reinstalling it after the completion of the covered warranty repairs, but shall not cover any liability for the loss of service or downtime costs of the apparatus.
Specify Mfr. Warranty _____________________________________
FOAM TANK WARRANTY COMPLY _____YES NO_____
The foam tank that is integral with the main stainless steel water tank shall carry a fifteen (15) year warranty against defects in workmanship and perforation corrosion. The provisions of this warranty shall be provided in the delivery documentation.
Specify Foam Tank Mfr. Warranty _____________________________________
FOLDABLE TANK WARRANTY COMPLY _____YES NO_____
The foldable 3,500 gallon tank shall carry a five (5) year warranty (minimum), against defects in workmanship, seam tearing, and corrosion; provided that the foldable tank is used in a normal and reasonable manner. The provisions of this warranty shall be provided in the delivery documentation.
Specify Foldable Tank Mfr. Warranty _____________________________________
INSPECTION TRIPS COMPLY _____YES NO_____
Designated NDF representatives will make in-plant inspections during the construction of the single 3,000 gallon Water Tender being manufactured. One NDF Fleet inspector and Chief Officer will travel to the vendor's fabrication facility to make these inspections. The vendor will make and purchase the hotel and airfare reservations for each designated NDF representative that is performing the scheduled inspections. The reservations that are procured will be the most direct route from the airport in Reno, NV to the airport nearest to the vehicle manufacturing facility, and the hotel will also be made available in the same immediate area. The inspections shall include but is not limited to the following:
A. Pre-painting inspection;
B. Final pre-delivery inspection; and
C. Delivery acceptance inspection.
It is the contractor's responsibility to:
A. Notify the NDF fourteen (14) working days in advance when requesting a required inspection.
REPEAT INSPECTIONS COMPLY _____YES NO_____
NDF is able to conduct up to two trips per unit on contract, with no labor cost to the contractor. If additional inspection trips are required by the contractor, or are necessary because of contractor scheduling, inspection rejections, or other contractor related cases, such inspection trips shall be at the expense of the contractor at the rate as follows:
*$60.00 per hour: (including travel time). This includes all travel and transportation expenses.
The hour rate shall be for a minimum of an eight (8) hour day if overnight travel is required. Airfare and hotel reservations will also be required to be procured by the contractor for the repeat inspections as necessary.
ACCEPTANCE INSPECTIONS COMPLY _____YES NO_____
The NDF designated representative shall perform a final pre-delivery inspection on each unit at the contractor's place of business prior to delivery of the completed unit. The final acceptance and operational inspection of the completed unit shall occur after the delivery of the unit to the NDF's Fleet Operations Facility in the Carson City area. The complete unit as presented to the NDF’s designated representative will be clean externally (freshly washed and chamois), and internally (vacuumed and wiped).
Additionally, the complete unit shall be serviced, (lube oil & filter changed) and checked for all requirements for operation (lube, oil, water, air, fuel, etc.) so the unit can be immediately put into service.
GENERAL INFORMATION
NDF REPRESENTIVE
The designated NDF representative will monitor and periodically inspect work as it progresses, and will consult with the contractor in all phases of construction up to the final test of each unit produced according to this contract. The term, "NDF Representative" as used in these specifications will be a Forestry Fleet Supervisor designated by the Nevada Division of Forestry.
DRAWINGS AND SPECIFICATIONS COMPLY _____YES NO_____
Each bid must be accompanied by scaled drawings and detailed descriptions covering the body and equipment that the bidder is proposing to furnish. Generic drawings will not be acceptable. The successful bidder shall provide complete drawings that include details of construction in addition to the following items: exhaust system location, compartments with dimensions, center console design, front & rear bumper design, door hardware, steps and handrail locations, tank design and location, fire pump compartment, housing, and plumbing design, fire hose bed design, location of emergency lighting, standard lighting, etc.
SERVICE / OPERATORS MANUALS COMPLY _____YES NO_____
Upon final delivery of each completed unit, the contractor shall submit to the NDF "as built" body components, exploded 3D-CAD views with part #'s, electrical, fire pump and related plumbing including valves, emergency lighting wiring schematics, complete component and parts lists, serial numbers, line setting tickets, etc. The contractor shall also supply the NDF a master copy with the original service/operators manuals of all the various installed components and schematics in binder format.
PREPARATION COMPLY _____YES NO_____
The contractor shall service all of the installed components with the manufacturer's recommended fluids. (i.e. oil, refrigerant, coolant, etc.) The contractor assumes full responsibility for failure or damage to components caused by lack of, or improper service at time of final inspection and acceptance.
SERVICE AND PARTS COMPLY _____YES NO_____
Each bidder shall demonstrate the ability to provide satisfactory service and parts supply, and shall state the locations of their service facilities and/or the authorized service representative within 120 miles of Carson City, Nevada.
CAB AND CHASSIS COMPLY _____YES NO_____
The vehicle, attachments, and special equipment as listed in the following specifications must be unused, and current production items manufactured for adaptation to one another. All driveline components are to be compatible with maximum torque of the engine that is offered. Highway delivery from manufacturer to contractor will be acceptable in "Full Mount" or "Half Mount" if the rear drivelines are removed. It is the intent of the NDF to operate the unit as a Water Tender that can travel on and off the highway under extremely severe conditions. All components shall be engineered and designed in such a manner that will prevent misalignment or interference of one another under extreme strain (fan and fan shroud, cab mounting, doors, fenders, hood, steering, etc.). In addition, where trade names are mentioned in this document, they are for reference purposes only. Any sole source or item restricted to a specific trade name will be identified. As stated previously, when there are relocations of cab accessories, i.e., mirrors, gauges, etc., to meet specifications and leaves holes, dents or other poor finish, the damage shall be repaired to the original component finish.
PUMP CERTIFICATION TEST COMPLY _____YES NO_____
The apparatus shall be certified to the requirements of NFPA 1901 prior to delivery of the completed apparatus. The certificate for the fire pump testing shall be furnished with the apparatus on delivery.
FIRE PUMP ID/DATA PLATE COMPLY _____YES NO_____
A durable fire pump identification and data plate, fabricated from corrosion resistant metal, shall be provided and installed on the pump operator's panel. The plate shall state the name and address of the apparatus manufacturer, the serial number of the unit and the pump performance test results.
WATER TENDER DATA PLATE COMPLY _____YES NO_____
A data plaque shall be provided and installed on the inside of driver's door. The data plaque shall contain the required information based on the applicable components of the apparatus:
• Engine oil
• Diesel fuel capacity
• Diesel Exhaust Fluid (DEF) capacity
• Engine coolant
• Chassis transmission fluid
• Drive axle lubricant
• Steer axle hub lubricant
• Power steering fluid
• Pump, generator or other component lubrication
• Paint manufacturer, type and color number
• Tire size, air pressure, and speed ratings
• General vehicle weights & dimensions
• Water tank information
• Foam Tank Information
• Other NFPA applicable fluid levels or data as required
Location shall be on the door panel on the driver's door.
HEAVY DUTY COMPLY _____YES NO_____
The term "heavy duty" as used in these specifications shall mean that the item of which the term is applied to shall exceed the usual quantity or capacity supplied with standard production vehicles, and it shall be able to withstand unusual strain, exposure, (including salt), temperatures, wear, etc., from the use of frequent off-road vehicle operations.
TRUCK MANUFACTURER/SPECIFICATIONS COMPLY _____YES NO_____
Unit bid shall be a 2017 International 7600 SFA, 6x4, conventional cab, 2-door chassis (SF567) - w/ Maxxforce 13 Engine, and/or maximum engine option available.
Specify Mfr. and Model _____________________________________
Specify Engine Mfr. and Model _______________________________
VEHICLE WEIGHT RATING AND PAYLOAD COMPLY _____YES NO_____
This agency is extremely concerned about the curb weight, payload allowance, center of gravity and weight distribution due to the personnel and equipment to be carried, and the unique operating conditions that are encountered. The chassis manufacturers displayed gross vehicle weight rating (GVWR) for the vehicle shall not be altered.
NOTE: The successful bidder must provide upon delivery, a certified weight slip showing total curb weight and front and rear axle weights.
The in-service weight shall not exceed 90% of the front axle GAWR and 46,000 lb. on the rear axles when:
• fully loaded with water, foam and fuel,
• with 270 lbs. per seat, and
• 2,000 lbs. of equipment evenly distributed in the storage compartments.
GENERAL DIMENSIONS AND WEIGHTS COMPLY _____YES NO_____
Manufacturer's gross vehicle weight rating shall be approximately 62,540 lbs.
Specify Completed Vehicle GVW ____________________________
Bare cab/chassis curb weight with specified tires to be approximately 14,000 lbs.
Specify Bare Cab/Chassis Curb Weight ________________________
Wheelbase shall be approximately 226".
Specify Wheelbase ___________________________
Clear cab to centerline of rear axle shall be approximately 142.50".
Specify Dimensions __________________________
Frame to centerline of rear axle shall be approximately 96".
Specify Dimensions __________________________
FRAME COMPLY _____YES NO_____
“C" channel frame, heat treated alloy steel with yield strength at a minimum of 120,000 psi yield. Frame shall include additional factory reinforcement package.
Specify Frame Type _________________Yield Strength ________________
FRAME EXTENSION, FRONT COMPLY _____YES NO_____
Integral; 20" In Front of Grille
GRAVEL SHIELD – FRONT BUMPER ATTACK LINE COMPARTMENT
COMPLY _____YES NO_____
A gravel shield shall be installed filling the area above the extension rails. The gravel shield shall incorporate a compartment with a latch able lid. This compartment shall be adequately sized to conceal a 1.5”X 15 foot bumper attack line with an Akron assault nozzle hooked to the front discharge wye. The lid shall be mounted to a stainless hinge and incorporate the same handle as the other compartments on the build. This gravel shield shall be constructed of .125" thick non-skid, bright aluminum tread plate, and shall be supported at the front by the top flange of the bumper. At the rear, the gravel shield shall be supported by a substructure.
OVERALL CRITICAL DIMENSIONS
a. Overall vehicle chassis/build-up length is to be roughly 343” Specify Length _________
b. Overall width is to be roughly 99 inches. Specify Width __________
c. Overall vehicle height is to be no more than 120 inches. Specify Height __________
d. Over center clearance to be no less than 18". Specify Clearance _______
e. Departure angle to be no less than 20 degrees. Specify Angle __________
f. Approach angle to be no less than 25 degrees. Specify Angle __________
BODY MODULE & TANK CAPACITIES COMPLY _____YES NO_____
The total capacity of the body module exterior compartments shall be 104 cubic feet excluding the pump body compartment.
The fire pump housing shall have an overall height of roughly 100”.
The fabricated body, minus the pump housing, shall have an overall height of 60.5".
The tank size shall be roughly 178” long X 74” wide X 58” tall.
The total capacity of tank shall be 3,000 gallons.
SIDE-SLOPE STABILITY COMPLY _____YES NO______
The manufacturer shall fabricate the tank of the vehicle in such a way as to provide for the best low center of gravity as possible. The NFPA 1906 – Standard for Wildland Fire Apparatus establishes requirements for vehicle stability, weight distribution and load distribution. Vehicles must be capable of operating on 20% grades, and must pass a 30° stability test (27° for GVW’s > 33,000 lbs.).
A test vehicle shall be placed on a tilt table to test break-over angle. The vehicle will be certified to operate within the NFPA 1906 vehicle stability requirements.
NOTE: The documentation shall be provided upon receiving the vehicles at delivery, and a certification label shall be placed in the driver side door jam.
GENERAL SPECIFICATIONS
ENGINE COMPLY _____YES NO_____
The engine shall be a turbocharged 475+ horsepower diesel engine, with at least 1,700 ft. lbs. of torque. The diesel engine shall be equipped with a dry air filter element w/fire safety screen, an inner air filter element, air filter restriction gauge, full flow oil filter, and engine governor, set at manufacturer's recommended governed speed. Crankcase and oil pressure system shall be designed to provide full pressure lubrication when ascending or descending at 45% grade, and/or operating on a 30% side slope. A "Jacobs Retarder" or International Diamond Logic engine brake for Maxx Force I6 engines that is electronically controlled shall also be provided. Specific interface and programming with transmission shall not cause harm to the engine by an excessive spike in engine RPM’s from having the system activated and down shifting automatically at high road speeds when the retarder is engaged
Specify Mfr. & No. _____________________ Specify HP _________ @ _______ lbs. torque
TRANSMISSION COMPLY _____YES NO_____
Shall be an automatic, Allison 4500 RDS_P (6-speed), must be the latest in series and with modulator lock-up features incorporated/built in. Transmission will include oil level sensor, and provisions for a PTO to drive the Water Tender’s fire pump. The transmission and related wiring shall include a spare input/output for the emergency vehicle series. Shift control shall be keypad type.
Specify Transmission Mfr. & Model _____________________________________________
TRANSMISSION PTO – FIRE PUMP COMPLY _____YES NO_____
A transmission power take-off (PTO) unit shall be provided and installed on the chassis automatic transmission to drive the firefighting water pump. The PTO shall be a 10-bolt type, “Hot Shift” style, with a torque rating that meets the engine speed ratio that provides the required pump performance. The PTO driveshaft shall be equipped with Spicer 1410 series universal joints. The PTO shift mechanism shall be located in the cab interior in a location accessible to both the driver’s and officer’s seating positions, typically on the center console, and also located on the left pump operator’s panel within easy reach of the operator, and shall include indicator lights as mandated by NFPA # 1901 latest editions.
Specify PTO Mfr. & Model _____________________________________________
ENGINE COOLING SYSTEM COMPLY _____YES NO_____
Shall be the manufacturer's maximum option available for engine and transmission combination, and thermostatically controlled with a pressure regulated overflow system. System shall be designed to provide maximum cooling efficiency and cross flow circulation of coolant when ascending, descending, or parked (engine idling) on 45% grades, and when engine is the power source for the Water Tender high pressure water pump. Fan drive shall be a Horton Drive Master Polar Extreme, direct drive type, two speed, with residual torque device for disengaged fan speed. The optional engine fan override switch will be included. Fan blade shall be of nylon construction. The radiator shall be of aluminum construction, with front to back cross flow series system design, with a 1593 sq. in. core, minimum. The included charge air cooler shall be 1548 sq. in. capacity, minimum. The cooling system will be equipped with premium rubber hoses. The cooling system will be filled with extended life coolant, rated to - 40° F, and shall include a de-aeration system with surge tank.
SECONDARY ENGINE COOLING SYSTEM COMPLY _____YES NO_____
A (Sen-Dure) auxiliary engine water cooler shall be included, located near the engine compartment, plumbed into the engine coolant system, and into the main fire pump water system to assist in cooling the truck diesel engine during stationary pump operations. A 3/4” (or greater) sized supply line will be installed from the discharge side of the main pump to deliver metered water through a relatively low pressure heat exchanger/cooler system. The heat exchanger/cooler shall not allow mixing of the chassis coolant and water from the fire pump. The ¼ turn “Engine Cooler” valve shall be located on the left side of the operator’s pump panel. The cooler return line shall pass through a check valve into the water tank.
TRANSMISSION COOLING SYSTEM COMPLY _____YES NO_____
An integrated radiator or external auxiliary (Modine) oil cooler shall be provided for the Allison automatic transmission, and plumbed between the engine coolant supply, and the transmission oil pan housing.
EXHAUST SYSTEM COMPLY _____YES NO_____
The OEM DPF, muffler(s), tail pipe(s) and header pipe(s) may require relocation and/or modification. The exhaust system on the chassis shall be frame mounted on the right side, under the cab; and shall include the vertical tail pipe that is frame & cab mounted, that is on the right hand side of the back of the cab. The after treatment device will be of the switchback horizontal design. The frame & cab mounted vertical tail pipe will have a stainless steel shield to protect employees from heat & burns from the exhaust system. The tail pipe(s) and muffler(s) shall be mounted to provide as much ground clearance as possible. Care must be exercised to protect such items as fuel lines, electrical wiring, brake hoses, compartment floors, batteries, fuel and water tanks, etc. from high exhaust heat. To accomplish this purpose, Storm King wrap and heat shielding shall be added as needed. The area over the right side under the cab shall have the tailpipe wrapped to prevent excessive heat from beneath the cab. When completed, the exhaust system on the vehicle shall be in accordance with Federal Motor Carrier Safety Regulations, Part 393.83. Exhaust system design shall be discussed during the pre-construction conference.
FUEL TANK COMPLY _____YES NO_____
The fuel tank shall be constructed of non-polished aluminum, D style, top draw, 19” deep, and frame mounted on the left side, under the cab. Fuel capacity shall be 80-gallons minimum. The tank or tank mounting is not to extend rearward past vertical alignment with the back of the cab. Tank will have (BMCS) approved fuel cap, tank vent and fuel drain. The fuel line is to be installed with proper support and protection. The fuel filtration equipment shall meet the engine manufacturer's requirements.
Specify Fuel Tank Capacity _______________________________
FUEL SYSTEM HEATER COMPLY _____YES NO_____
The fuel systems for the chassis diesel engine shall be equipped with an in-line heater system to aide in extreme cold weather vehicle operation.
FUEL TANK VENT EXTENSION COMPLY _____YES NO_____
The OEM fuel tank vent line shall be extended from the fuel tank check valve and vented to the atmosphere. The vent line shall extend vertically from the tank to the bottom of the cab rear window and then bend 180 degrees towards the ground. A vent plug orifice (#60 drill size) shall be installed into the upper end of each line. No fuel tank roll over protection check valves shall be removed from the fuel system.
DIESEL EXHAUST FLUID (DEF) TANK COMPLY _____YES NO_____
The vehicle shall be equipped with a DEF tank to meet current Federal emission standards. The DEF tank shall be frame mounted on the left side, under the cab. The DEF tank capacity shall be 9.5-gallons, minimum. The tank itself or the tank mounting is not to extend rearward past vertical alignment with the back of the cab. Tank shall have an approved cap, tank vent, and drain. The DEF tank lines are to be installed with proper support and protection. Diesel exhaust fluid filtration equipment, if any, shall meet engine manufacturer's requirements.
Specify Fuel Tank Capacity _______________________________
FUEL AND DEF TANK SKID PLATE COMPLY _____YES NO_____
A heavy duty removable skid plate that is painted to match the color of the vehicle’s frame shall be fastened to the bottom side of the fuel and DEF tank hangers. This removable skid plate shall be turned up on the front and rear sides to prevent the tank mounting system from digging into the ground when the apparatus is maneuvering in off-road conditions.
AXLE; FRONT COMPLY _____YES NO_____
The front steer axle shall have a minimum rating of 18,000 lbs., Meritor #MFS-18-133A or equivalent, and will be a wide-track, I-Beam type. The front axle is to include oil-filled hubs, and be OEM approved for this application.
Specify Mfr. _____________________________ Minimum Rating ______________
AXLE; REAR COMPLY _____YES NO_____
The tandem rear axles shall be full floating; hypoid or spiral bevel; single reduction, Meritor #RT-46-160P or equivalent, rated at 46,000 lbs. A driver-controlled locking differential is to be provided in the rear-rear axle, with indicator light. The tandem rear axles are to be equipped with a power divider lock that is operated by electric over air, and shall include a cab control and indicator light. The rear differentials will be equipped with a lube pump. Final vehicle gear ratio to allow for 80 MPH at rated engine RPM with transmission in 6th gear at “0%" road grade. (Maximum Nevada posted speed limit 75 MPH) The axles will include a magnetic drain plug, and will be filled with synthetic gear oil, (EmGard FE-75-W-90).
Specify Type ____________________ Rating __________________
FRONT SUSPENSION COMPLY _____YES NO_____
The suspension system on the front of the Water Tender shall be comprised of 18,000 lb. capacity parabolic taper leaf springs that are semi-elliptical, with a total rated capacity at the ground equal to the maximum rating of the front axle. The leaf spring shackles shall be grease-able. The front suspension will include shock absorbers, heavy-duty option.
Specify Type ____________________ Rating __________________
REAR SUSPENSION COMPLY _____YES NO_____
The tandem suspension system on the rear of the Water Tender shall be comprised of a Hendrickson 46,000 lb. capacity walking beam type suspension system, with rubber end bushings, and transverse torque rods. The rear suspension shall be a Hendrickson #HMX-460-54 or equivalent, with axle spacing of 54”. The rear suspension will include four (4) shock absorbers, heavy-duty option.
Specify Type ____________________ Rating __________________
WHEELS AND TIRES COMPLY _____YES NO_____
WHEELS: (11 each) size 22.5 X 8.25 for 22.5 tires, ventilated, steel disc, hub Pilot, 10 lug, single front, dual rear, with single flange nut installation. All wheels shall be interchangeable with one another. Wheel type and size must assure proper overall and compatible front and rear tread width.
Specify Size __________________________________
FRONT TIRES: (2 each) 315/80R22.5 18 ply Continental HSC-1 heavy-duty steer tires. Available tires will be further discussed at the pre-construction conference.
Specify size _______________________________
REAR TIRES: (8 each) 11R22.5 16 ply Continental HDR-2 closed-shoulder traction tires. Available tires will be further discussed at the pre-construction conference.
Specify size _______________________________
SPARE TIRE COMPLY _____YES NO_____
A spare wheel and (1) 11R22.5 Continental HSC-1 will be shipped to the body builder with the vehicle, which shall be strapped to the frame rails. Vendor will have a check-in and accountability process for the included spare wheel and tire.
BRAKES; PARKING COMPLY _____YES NO_____
The vehicle shall include rear tandem axle wheel spring brakes with parking brake control and the SR-7 relay valve. The parking brake is to be set with "pull" action, and released with "push" action.
BRAKES; SERVICE COMPLY _____YES NO_____
The truck brake system is to meet all Federal and State requirements for air brakes, and shall include a Bendix anti-lock brake system that provides 4-channel automatic full vehicle wheel control. The supply air for the vehicle braking system is to be the maximum capacity available for the brake assemblies on each axle. The “S" cam brake design is preferred on the drum airbrakes system. The engine mounted air compressor shall be a Bendix BA-921, with 15.9 CFM capacity, and must be liquid cooled. The compressor’s air source is to be routed from the engine dual stage air cleaner housing. Front brakes are to be sized 16.5” x 6", with 24 sq. in. long stroke brake chambers, and the rear brakes are to be sized 16.5” x 7", and are to include 30/30 sq. in. long stroke spring brake chambers. Air system is to have a Bendix AD-IP spin-on cartridge filter air dryer assembly and integral heater, with the height dimension no greater than frame rail depth, (Ref: BW AD-g). Automatic slack adjusters are to be provided on all axles. DV-2 heated drain valves on the chassis air tanks shall also be provided. Brakes are to have dust shields on the front and rear of the vehicle.
Specify Front Brake Size ____________________ Rear Brake Size ____________________
NOTE: No component of the Original Equipment Manufacturer’s brake system shall be moved or modified.
STEERING SYSTEM COMPLY _____YES NO_____
Vehicle is to be equipped with power-assisted steering. The vehicle shall have a 2-spoke, 18” diameter steering wheel. The steering column shall be of the tilting and telescoping type. The steering gear shall be a Sheppard M-100 or as best determined by the manufacturer.
Specify Steering System Type ________________________________
CAB CONFIGURATION COMPLY _____YES NO_____
The vehicle cab shall be a (two) 2-door, OEM manufactured all metal conventional cab with welded type construction, with front fenders, and a single piece square style front bumper; and shall include the following:
a. Extended tilt hood or tilt hood and fenders – shall include under hood insulation for sound abatement.
b. Cab grab bars/handles – driver & passenger side
c. Cab rear suspension – air bag type
d. Cab interior trim – premium, fully covered interior on rear of cab
e. Chrome front grille
f. Bug screen – screen shall be mounted in the front-end, behind the grille.
g. Splash panel insulation – Insulation shall be included on the splash panels for sound abatement.
h. Front bumper – steel, square front design with angled sides, - powder coated grey
i. Frame extension – front integral, 20 in.
j. Driver’s air ride bucket seat w/ (2) armrests with vinyl covering.
k. Passenger’s bucket seat mounted on top of battery box w/ (2) armrests with vinyl covering
l. 3-point seat belts (Red) – both cab seating positions
m. Armrests - both doors
n. Factory floor matting - shall include removable rubberized debris mats
o. Windows - tinted glass
p. Two adjustable sun visors
q. Air conditioning
r. AM / FM weather-band AUX/CD stereo with four speakers, 2 overhead, and 2 in the rear of cab
s. Power door locks
t. Power windows
u. Engine fan override switch
v. Diesel Particulate Filter Regeneration Inhibit Switch
w. Dual electric 2-speed / intermittent windshield wipers
x. Dual horns – Air & Electric
y. 100+ dba back-up alarm.
z. 2-way radio wiring effects – wiring with 20 amp fuse protection, includes ignition wire with 5 amp fuse, wire ends, heat shrink, and 10' coil taped to base harness.
aa. Battery master disconnect switch - driver's side, floor mounted
ab. OEM integral cup holder – dash mounted
ac. Power accessory outlet – dash mounted
ad. Fresh air heater and defroster
ae. HVAC fresh air filter with a stainless ember screen
af. Storage compartment in each cab door
ag. Keyed ignition switch shutoff
ah. Warning system – low coolant, low fuel, low oil pressure, low battery voltage, high engine temp.
ai. Low air (brake) pressure warning device
aj. Dual front frame mounted tow hooks or eyes
ak. Tilting steering column
al. Overhead instrument cluster outfitted with direction & outside temperature
am. Power & heated mirrors - 7.09" x 15.75" mirror with 7.5" square convex mirror mounted below primary mirror, break-away type, with clearance LED lights.
an. Body builder module – frame-mounted body builder module and wiring
ao. Engine control – remote mounted, provisions that are to include wiring for body builder installation of PTO controls, and with ignition switch control for MaxxForce electronic engines.
ap. Circuit breakers – vehicle will be equipped with manual reset circuit breakers at the main fuse panel, with trip indicators, and will replace all fuses except for 5-Amp circuit fuses.
aq. Storm King fire wrap on air and electrical lines below the vehicle frame rail with stainless retaining straps
ar. Center control console with specified components
CAB INSTRUMENTS AND GAUGES COMPLY _____YES NO_____
(Minimum Complement) All gauges to be in-dash mounted:
as. Indicating voltmeter
at. Air pressure gauge
au. Oil pressure gauge
av. DEF fluid level gauge
aw. Engine coolant temperature gauge
ax. Fuel level gauge
ay. Speedometer
az. Odometer
ba. IP cluster display – fault codes
bb. Intake air filter restriction gauge vacuum activated Donaldson P/N RAX 00-5806
bc. Tachometer
bd. Transmission oil temperature gauge
be. Engine hour meter (actual run time)
bf. PTO hour meter (actual run time) with indicator light and related wiring.
CAB INTERIOR COMPLY _____YES NO_____
Shall be a vinyl "Premium" trim package. Storage compartments shall be provided in both cab doors and above the front windshield, below the headliner. Seat color shall be (grey).
CHARGING SYSTEM COMPLY _____YES NO_____
The alternator for the vehicle shall be 12 volts, brush type, Leece Neville (14931PAH) that is rated at a minimum of 320 amps with an output at 14 volts, or equivalent. The alternator pulley shall be 2.4” in diameter, for increased alternator output at idle. Mounting shall be pad type. Circuit system protection shall be standard.
Specify Mfr. & No. of Alternator _______________________________
STARTING MOTOR COMPLY _____YES NO_____
The electric starter motor for the engine of the vehicle shall be a Mitsubishi 105P or equivalent, that is 12 volt, gear reduced, with thermal over-crank protection.
Specify Mfr. & No. of Starter _______________________________
BATTERIES COMPLY _____YES NO_____
The vehicle shall include three (3) sealed maintenance-free batteries, BCI "Group 31" design, high cycle, with 2775 CCA total. Battery box shall be steel, equipped with a removable cover, and mounted beneath the right front passenger’s seat within the cab of the vehicle. The batteries shall be vented to the outside of the vehicle. A battery jump start stud connected to the positive terminal shall be included, and placed on the outside of the vehicle in an accessible location.
LIGHTING COMPLY _____YES NO_____
The vehicle shall be equipped with the following lighting:
a. Halogen sealed beam headlights, round, with chrome plated bezels, and equipped with a controlled beam switch.
b. Automatic Light Check Function
c. Daytime running lights
d. Automatic Lights w/Wipers Function
e. Parking lights
f. Front off-road driving lights
g. Two rear LED stop and tail lights
h. Two rear LED turn signal lights
i. Two rear LED reverse lights
j. Side and rear scene lights
k. Instrument panel lights
l. Interior dome lighting, door switch operated (on both doors).
m. Courtesy lights– mounted in front & rear map pocket, right and left side
n. Side LED marker lights
o. Clearance and identification LED lights
p. Two front mounted turn signal lights
q. Hazard warning light switch
r. Self-canceling flashing turn signal light switch (OEM)
s. Emergency vehicle lighting as specified
t. All lighting to meet NFPA and FMCSS regulations
FINISH, PAINT COMPLY _____YES NO_____
Cab & wheels shall be painted gloss white in color. All frames, drivelines, and undercarriage shall be undercoated semi - gloss black in color.
CAB / CHASSIS DOCUMENTS COMPLY _____YES NO_____
One copy of the Owners / Operators Manuals applicable to the vehicle shall be supplied for the unit ordered. One copy of line set documents of reproducible quality for the unit ordered shall be provided. (These documents shall identify each wear item that is fabricated or is a component that is installed by the body manufacturer, and must be identified by name, model, and part number; as to be usable for obtaining parts once the vehicle is in the field, as a complete fire apparatus.)
CONTROLS AND ACCESSORIES COMPLY _____YES NO_____
Any control or accessory items connected into the OEM main chassis engine or transmission electronic management systems shall be installed as directed by the chassis manufacturer, using their specified hardware or components. The vehicle shall be equipped with throttle hand control for the PTO. The vehicle shall also be equipped with a remote mounted engine control, with wiring for the body. The fire pump panel control will be wired into these systems by the Water Tender manufacturer.
WATER TENDER PUMPS & ACCESSORIES
FIRE PUMP SYSTEM DETAILS COMPLY _____YES NO_____
The pump module must employ Hydra Technology. Due to the design, a fire pump module that is manufactured with Hydra Technology is compact in size, and massive in performance.
Each component in the module must undergo a selection and placement of analysis staff engineers. Utilizing advanced 3D software, the engineers’ goals must provide component placements for ergonomics with a completed module that produces maximum water flow with optimum versatility. Only after the complete analysis and build of the module utilizing computer design equipment, can the build of the hardware in the shop begin.
Pump module design beginning with a foundation; cage framework assemblies that are precision manufactured from strong, corrosion free, heavy wall, stainless steel tubing. This framework mounts to the truck frame through a mounting design complimented with iso-mount elastomer cushions. The result shall be a mounting system that allows for the twisting movement of the truck frame without undue stress loading of the pump module.
Next assembled shall be the stainless steel side panels. Brushed or powder coated stainless steel side panels shall provide strength and durability.
A thorough review of the valve control and switch placements on the control module shall result in a neat and orderly layout. The horizontal control rods shall appear neat and orderly. The appearance is only a portion of the requirement. The same neat and orderly appearance after countless hours of engineering design and ergonomic study shall provide a smooth trouble free linkage for valve operation. The gauge panel door shall be an expansive double wall stainless door supported by a 3/8 inch diameter hinge pin. The double wall door provides unsurpassed strength and gauge protection while thwarting the casual attempt of tinkering. Authorized servicing of the components within the door is simplified with a bolt on access panel.
The apparatus stainless steel piping, stainless steel panels, and a stainless steel framework are all to provide years of trouble free service. Pipe threads are not allowed on plumbing larger than 1.5 inch in diameter. The pump module design shall employ Victaulic coupling connections in the pump module to save time when servicing a component. Installation of components without the use of pipe threads allows for “drop-out” maintenance of critical components without disassembly of entire piping systems. Drop in valves and manifolds with Victaulic couplings are only the start of the serviceability designed into this pump module.
The apparatus shall be designed to meet the specified rating at 0 to 5000' altitude.
NOTE: Apparatus Manufacturers taking exception to any portion of this requirement will not be acceptable.
FIRE PUMP PANEL COMPLY _____YES NO_____
The Water Tender shall be equipped with a main fire pump control panel that is located on the left, driver’s side of the body build-up. All pump controls and gauges shall be properly identified. The layout of the pump control panel shall be ergonomically efficient and systematically organized. The pump operator's panel shall be removable in two (2) main sections for ease of maintenance. The pump and gauge panels shall be constructed of 12-gauge stainless steel. The gauge panel shall contain a panel for mounting of all instruments, lighting switches, engine monitoring system, engine cooling controls, and pressure control system. The gauge panel shall be a double panel door design to protect in the enclosed door all gauge tubing, switch, and control wiring. The inner pan shall bolt onto the stainless steel exterior panel. As previously stated, there shall be an access panel in the inner panel that is easily removable for control or gauge service or replacement.
The gauge panel door shall be designed as an opening pump house service door on the street (left) side of the pump house. This gauge panel door shall provide an opening minimum size of 28 inches wide by 14 inches in height or as best determined by the manufacturer. The lower section of the panel shall contain all inlets, outlets and drains. All push-pull valve controls shall have quarter-turn locking control rods with chrome plated zinc tee handles. Guides for the push-pull control rods shall be chrome plated zinc castings securely mounted to the pump panel. Push-pull valve controls shall be capable of locking in any position. The control rods shall pull straight out of the panel, and shall be equipped with universal joints to eliminate binding. The side gauge access door, the side middle horizontal support panel, the inlet/discharge panel, and the side drain panel on the left side of the pump module shall have a black powder coat finish. The right side of the pump panel intake valve area shall be brushed stainless steel.
The fire pump panels’ lower step shall be an integral component of the pump compartment. This step shall be spaced down from the bottom of the pump module side panels to allow water to flow freely away from the running board area, and shall be made from a diamond tread aluminum material. The running board supports shall be welded directly to the pump frame structure to provide proper support. It is the opinion that service access to the pump, valves, gauges and controls are of the utmost importance. Special consideration shall be taken when evaluating the pump module design of each fire apparatus manufacturer. Pump panels that offer little to no access without the use of tools shall not be considered compliant with this requirement. The pump panel layout and design shall be discussed during the pre-construction conference.
Specify Size of Fire Pump Panel & Access Door ____________________________________________
NOMENCLATURE PLATES COMPLY _____YES NO_____
5/8" X 3" metal, Vision Mark (or equal) individual nomenclature plates shall readily identify all switches, valves, and controls. The lettering shall be deeply etched enamel paint-filled or anodized aluminum-etched color coded tags, and shall describe the function of all the pump panel controls, switches, discharge, and suction valves. The plates shall be attached with stainless steel nylock nuts and machine screws where allowable. (Plastic I.D. plates, adhesive backed plates, and/or self-tapping screws are unacceptable).
All intakes, drains, and discharges are to be labeled as to their size and function.
Specify Nomenclature Plates Mfr. & Size _____________________________________________
WATER TANK LEVEL INDICATOR COMPLY _____YES NO_____
The vehicle shall be equipped with a Fire Research Tank Vision model WLA200-A00 tank indicator kit. The kit shall include an electronic indicator module, a pressure sensor, and a 10' sensor cable. The indicator shall show the volume of water in the tank on nine (9) easy to see super bright LEDs. A wide view lens over the LEDs shall provide for a viewing angle of 180 degrees. The indicator case shall be waterproof, manufactured of aluminum, and have a distinctive blue label. The indicator shall be mounted on the Water Tender pump panel and center console inside the cab of the vehicle. An additional water tank level indicator gauge shall be mounted on the right side pump panel, on the right side of the vehicle.
The program features shall be accessed from the front of the indicator module. The program shall support self-diagnostics capabilities, self-calibration, and a data link to connect remote indicators. Low water warnings shall include flashing LEDs at 1/4 tank, down chasing LEDs when the tank is almost empty, and an output for an audio alarm. The indicator shall receive an input signal from an electronic pressure sensor. The sensor shall be mounted from the outside of the water tank near the bottom. No water level probe shall be placed on the interior of the tank. Wiring shall be weather resistant and have automotive type plug-in connectors.
Specify Mfr. & Model _____________________________________________
FIRE PUMP CONTROLS & GUAGES COMPLY _____YES NO_____
The following shall be provided on the pump and gauge panels in a neat and orderly fashion:
FOAM CONTROL PANEL
The control panel for the foam system will be located on the pump panel. Please see individual section listing for specific requirements.
LIGHTING CONTROL PANEL
The control panel for the exterior work lighting system will be located on the pump panel, and shall include weather-proof switches and proper labeling for the following:
• Pump Panel Lights
• Ground Lights
• Left Scene Lights
• Right Scene Lights
• Rear Work Lights
• Horn
PRESSURE GOVERNOR AND MONITORING DISPLAY COMPLY _____YES NO_____
A Fire Research INCONTROL series TGA400-A00 pressure governor and monitoring display kit shall be installed. The kit shall include a control module, 600 psi pressure sensor, and cables. The control module case shall be waterproof and have dimensions that are not to exceed 6 3/4" high by 4 5/8" wide by 1 3/4" deep. Inputs for monitored information shall be from a J1939 data bus, or from independent sensors. Outputs for engine control shall be on the J1939 data bus or engine specific wiring.
The following continuous displays shall be provided:
• CHECK ENGINE and STOP ENGINE warning LEDs
• Engine RPM; shown with four daylight bright LED digits that are more than 1/2" high
• Engine OIL PRESSURE; shown on an LED bar graph display in 10 psi increments
• Engine TEMPERTURE; shown on an LED bar graph display in 10 degree increments
• BATTERY VOLTAGE; shown on an LED bar graph display in 0.5 volt increments
• PSI / RPM setting; shown on a dot matrix message display
• PSI and RPM mode LEDs
• THROTTLE READY LED.
A dot-matrix message display shall show diagnostic and warning messages as they occur. It shall show monitored apparatus information, stored data, and program options when selected by the operator.
The program shall store the accumulated operating hours for the pump and engine, previous incident hours, and current incident hours in a non-volatile memory. Stored elapsed hours shall be displayed at the push of a button. It shall monitor inputs and support audible and visual warning alarms for the following conditions:
• High Engine RPM
• High Transmission Temperature
• Low Battery Voltage (Engine Off)
• Low Battery Voltage (Engine Running)
• High Battery Voltage
• Low Engine Oil Pressure
• High Engine Coolant Temperature
The governor shall operate in two control modes, pressure and RPM. No discharge pressure or engine RPM variation shall occur when switching between modes. A control knob that uses optical technology shall adjust pressure or RPM settings. It shall be 2" in diameter with no mechanical stops, a serrated grip, and have a red idle push button in the center.
A throttle ready LED shall light-up when the interlock signal is recognized. The governor shall start in pressure mode and set the engine RPM to idle. In pressure mode, the governor shall automatically regulate the discharge pressure at the level set by the operator. In RPM mode, the governor shall maintain the engine RPM at the level set by the operator except in the event of a discharge pressure increase. The governor shall limit a discharge pressure increase in RPM mode to a maximum of 30 psi. Other safety features shall include recognition of no water conditions with an automatic programmed response, and a push button to return the engine to idle.
Specify Governor Monitor/Display Mfr. & Model ________________________________________
PRESSURE GOVERNOR and MONITORING DISPLAY BUZZER COMPLY _____YES NO_____
Fire Research Pump InControl option for an audible alarm buzzer shall be installed. The buzzer shall sound when a signal from the InControl monitor activates it.
MASTER GAUGES COMPLY _____YES NO_____
The pump master vacuum and pressure gauges shall be 3.5" in diameter with white dial face gauges with black lettering and markings. The master vacuum gauge shall be a compound style gauge with a vacuum/pressure range of -30"~0~400 psi. with the dial face of the gauge labeled in black INTAKE. The master pressure gauge shall be provided with a range of 0-400 psi and the dial face of the gauge labeled in black DISCHARGE. The gauges shall be liquid less, with a dash-pot shock & vibration resistant movement. The cases shall be temperature compensated with an internal breathing diaphragm. The gauge accuracy shall be plus or minus 1% of full scale per ANSI B40.1, Grade 1A. To prevent internal freezing and to keep contaminants from entering the gauge, the stem and bourdon tube shall be filled with low temperature oil, and be sealed from the water system using an isolating diaphragm located in the stem. A bright metal bezel shall be supplied with each gauge that is resistant to corrosion, and protects the lens from damage.
MASTER GAUGE TEST PORTS COMPLY _____YES NO_____
Adjacent to each gauge, there shall be a pressure tap to provide simultaneous reading of the vacuum and pressure exerted on the individual gauge; it shall also be supplied with the proper identification label.
PRESSURE GAUGES COMPLY _____YES NO_____
Each line pressure gauge shall be mounted immediately above the control for the corresponding valve. The individual line pressure gauges for the discharges shall be 2.5" in diameter with white dial face gauges with black lettering and markings. The gauges shall be a compound style gauge with a vacuum/pressure range of 0 - 400 psig. The gauges shall be fluid filled with pulse and vibration dampening Interlube to lubricate the internal mechanisms to prevent lens condensation and to ensure proper operation to -40 degrees F. The cases shall be temperature compensated with an internal breathing diaphragm to permit fully filled cases and to allow a rigid lens with a distortion free viewing area. The gauge accuracy for the gauge shall be plus or minus 2% mid-scale, plus or minus 3% balance, per ANSI B40.1, Grade 1A. To prevent internal freezing and to keep contaminants from entering the gauge, the stem and bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem. A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.
All line pressure gauges shall be mounted adjacent to the corresponding discharge control tee handles.
FIRE PUMP COMPLY _____YES NO_____
The apparatus is to be equipped with a chassis mounted fire pump. The pump shall have pump and roll capabilities. The pump is to be driven from the PTO on the transmission. The contractor shall provide and install a Darley JMP 500 pump, a PTO-operated 500 G.P.M. fire service rated 2-stage centrifugal pump that provides water pressure to all discharges.
The pump unit shall be fully capable of meeting the National Fire Protection Association (NFPA) # 1901, latest editions, standards for initial attack fire apparatus. The pump shall have the capacity of 500 gallons per minute rated performance. The entire pump shall be assembled, and tested at the pump manufacturer's factory.
Additionally, the main fire pump shall be designed so repairs can be made by replacement of normal repair parts, i.e., seals, bearings, impeller and wear rings in a standard shop setting. The impeller and wear rings shall be made of bronze material. The pump pressure shall be tested to a minimum of 600 psi. The impeller shaft seal shall be a mechanical, self-adjusting type. The pump shall be painted to match the color of the chassis. The fire pump must be provided with the OEM pump manufacturer's transfer valve air cylinder assembly or electric transfer valve actuator assembly, bracketing and wiring harness. NO EXCEPTIONS
The PTO pump shall be mounted in a manner that the pump and gear case can be completely removed from beneath the truck for repair or replacement in a minimal amount of time. All pump mounting brackets shall be powder coated to match the color of the chassis.
Specify Fire Pump Mfr. & Model _____________________________________________
FIRE PUMP INSULATION PACKAGE COMPLY _____YES NO_____
The main mid-ship fire pump assembly shall include a cold weather insulation package to protect the fire pump from freezing during cold weather operations. A well-known or readily available cold weather insulation package shall be utilized for this purpose for ease of future replacement, if necessary.
PUMP DRIVE SHAFT COMPLY _____YES NO_____
A Spicer 1410 Series drive shaft shall be provided for the power from the transmission PTO to the fire pump. The fire pump and gear case shall be mounted in such a manner that the PTO driveline angles do not exceed the manufacturer's recommended angles for the u-joints, and shall be of the proper series and type specified by the pump and PTO manufacturer.
FIRE PUMP GEARBOX COMPLY _____YES NO_____
The gearbox shall be designed of ample capacity for lubrication reserve and to maintain the proper operating temperature. The pump ratio shall be selected by the apparatus manufacturer to give maximum performance with the engine and transmission selected.
PUMP SHIFT CONTROL COMPLY _____YES NO_____
The pump shift shall be air operated, and shall incorporate a double action piston to shift from road to pump and back. A manual or electric operated pump shift mechanism is not acceptable. The pump shift switch shall be mounted in the cab and on the pump panel, and identified as "PTO PUMP SHIFT" and include instructions permanently inscribed on the pump shift switch plates. The cab and pump panel operating switch shall have a protective cover to prevent it from accidentally being moved. The pump shift control assembly shall incorporate an indicating light system, which will notify the operator when the shift has been completed to PUMP and when the chassis transmission is in correct pumping gear.
The switch that activates the lights must be mounted on the pump transmission and positioned so that the pump shift arm activates the switch only when the shift arm has completed its full travel into PUMP position. An additional indicator light shall be provided adjacent to the throttle control at the pump operator's panel to indicate a completion of the pump shift.
PRIMING PUMP SYSTEM COMPLY _____YES NO_____
The priming pump shall be a Hale ESP-12 positive displacement vane type, oil-less, electrically driven, and conform to standards outlined in NFPA 1901. Activation of the priming system shall be accomplished by a push button switch. A priming button shall be located on the pump panel. A Hale SPV remote valve shall be used to isolate the intake system from the atmosphere when the primer is not in operation.
Specify Mfr. & Model _____________________________________________
FOAM SYSTEM COMPLY _____YES NO_____
A Foam Pro model 1600 built-in foam injection system shall be provided with the controls at the operator's pump panel. The foam system shall be a fully automatic, electronic, direct injection foam proportioning system. The system shall be capable of handling Class A foam concentrate. The foam proportioning operation shall be based on an accurate direct measurement of water flows, with no water flow restriction. The foam system shall be installed in accordance with the manufacturer's recommendations. The foam system shall have a 12 volt, 1/3 hp electric motor driven positive displacement piston type foam concentrate pump, with a rated capacity of .01 to 1.7 GPM at 200 psi, with a maximum operating pressure of 400 psi.
FOAM SYSTEM PRESSURE RELIEF ON SHUTDOWN
For firefighter safety, a time delayed solenoid valve and TDI Series interval timer with time delay ranges (1-1023 seconds) shall be installed in the 2" discharge manifold after the foam system check valve to discharge trapped manifold water pressure upon pump shut down. NO EXCEPTIONS TO THIS REQUIREMENT.
FOAM TANK REFILL SYSTEM COMPLY _____YES NO_____
A Hale truck mounted "EZ-Fill" foam tank fill system shall be provided and installed on the apparatus. The refill system shall provide the ability to automatically refill the Water Tenders’ foam tank from the ground, without carrying foam solution up to the fill tower at the top of the stainless steel water tank. The refill system shall be activated by a switch provided on a control panel with indicator lights mounted on the pump panel, and will automatically shut off when the foam tank is full. The refill system shall be equipped with fresh water flush capabilities, and a cam lock pickup tube connection located on the pump panel.
FOAM SYSTEM OUTLETS COMPLY _____YES NO_____
The foam system shall be distributed into the following discharge outlets:
• Front bumper 1.5” discharge
• Both 1.5”Pump house cross lay
FOAM SYSTEM CONTROLS COMPLY _____YES NO_____
The Foam Pro system shall be equipped with an electronic control unit, suitable for installation on the pump operator's pump panel. The control module shall provide the following functions:
• Activate the foam proportioning system.
• Provide selectable control of foam proportioning rates from 0.1% to 1.0%, in 0.1% increments
• Flash a "low concentrate" warning when the foam concentrate tank runs low on solution
There shall be a remote start - stop button located on the in cab console to allow operation of the foam unit from inside the cab.
Specify Foam System Mfr. & Model _____________________________________________
WATER TANK CONSTRUCTION COMPLY _____YES NO_____
The tank shall have a rated capacity in U.S. gallons, complete with a fifteen (15) year warranty. The tank manufacturer shall mark the tank and furnish notice that indicates proof of warranty. The purpose of the notice is to inform department personnel who store or use the tank that the unit is under warranty. The tank shall be constructed of 12ga. T-304 stainless steel. The 3,000 gallon stainless steel water tank shall have an approximate size of 58" X 74" X 178". The tank shall include the integrated 30 gallon foam tank, which will be mounted within the front wall of the tank. The tank shall be of a special configuration and is so designed to be completely independent of the body and compartments. All exterior tank joints and seems shall be welded and tested for maximum strength and integrity. The top of the tank shall be fitted with lifting eyes designed to facilitate easy removal. The tank is to be equipped with a baffling system that is comprised of 10ga. T-304 stainless steel heads, cross baffles, and foundation doublers. All partitions shall be equipped with vent and air holes to permit movement of air and water between compartments. The partitions shall be designed to provide maximum water flow and meet NFPA rules. The tank will include rubberized perma-slats (full length of foundation) and 3/16" A-36 M/S bolsters & foundation assembly (Painted Black) to secure the tank to the chassis, which will also include the use of (6) DOT tie down brackets. The tank is to remain satin (industrial standard 2B finish).
REAR ACCESS LADDER COMPLY _____YES NO_____
There shall be a rear access ladder welded to the tank with a minimum of three rungs made out of stainless steel. The ladder must extend above the tank to utilize as hand holds while accessing the top of the tank. The sides of the ladder must be round tubing with self-cleaning rungs. The ladder must be welded to fish plates on the tank to maximize the mounting surface area.
TANK SUMP AND CONNECTIONS COMPLY _____YES NO_____
There shall be one (1) sump, standard per tank. The sump shall be located as close as possible to the longitudinal center of the tank. The sump shall have a 5” FNPT threaded outlet, and a 2” drain plug with valve. All tanks shall have an anti-swirl plate located above the tank to pump connection. There will be two (2) standard tank outlets: one for tank to sump suction line, and one for a tank fill line. All tank fill couplings shall be backed with flow deflectors to break up the stream of water entering the tank, and be capable of withstanding sustained fill rates of up to 1,000 GPM. The addition of rear suction fittings, nurse valve fittings, dump valve fittings, and through tank sleeves to accommodate rear discharge piping must be specified. All auxiliary outlets and inlets must meet NFPA guidelines that are in effect at the time of tank manufacture.
TANK LID & FILL TOWER COMPLY _____YES NO_____
The tank fill tower shall be constructed of stainless steel, and shall have a minimum dimension of 20” on the outer perimeter. The tower shall be located in the center rear portion of the tank. The tank lid shall be outfitted with a hinged-type cover. Inside the fill tower, there shall either be a fill pipe leading to the integrated foam tank, or the foam tank fill can be at the front of the main tank. The vent overflow shall be a minimum ID of 4” that is designed to run through the tank, and shall be piped behind the rear axle beneath the tank.
REAR DISCHARGE CHUTE COMPLY _____YES NO_____
The rear of the tank needs to incorporate a 10” square, three (3) sided, three stage discharge chute. The discharge chute shall be located in the lower, center potion of the tank and discharge to each side and the rear of the water tender. The slide out stages shall be incorporated into the main chute and interchangeable. A locking shut off valve shall be incorporated into the rear discharge chute design, and each chute shall be independently controlled to select the desired discharge.
OVERFLOW AND VENT PIPE COMPLY _____YES NO_____
The water tank shall be fitted with an integral 4" ID combination overflow/vent pipe running from the fill tower through the tank to a 4" coupling flush mounted into the bottom of the tank to allow water to overflow beneath the chassis.
Specify Water Tank Mfr. & Model _____________________________________________
WATER TANK CAPACITY COMPLY _____YES NO_____
The water tank shall be rectangular shaped with rounded corners, and shall have a minimum capacity of 3,000 US gallons.
INTERNAL FOAM TANK COMPLY _____YES NO_____
A thirty (30) gallon foam concentrate tank shall be furnished as an internal component of the main water storage tank. The foam tank shall have an anti-foaming fill stack and removable screen located in an accessible area. The foam tank fill tower shall be equipped with a latch, pressure/vacuum vent, and have a sealed airtight cover. The foam tank shall be plumbed to the on board "Class A" foam system. A drain valve connection shall be provided at the lowest point of the foam tank. The foam tank shall be outfitted with a 1/4 turn 3/4" drain valve that is mounted on the pump panel.
The following labels shall be attached to the foam tank fill lid:
• "CLASS A FOAM TANK FILL"
• "WARNING: DO NOT MIX BRANDS AND TYPES OF FOAM"
WATER TENDER PLUMBING & VALVES
MASTER DRAIN COMPLY _____YES NO_____
The apparatus shall be equipped with a manually operated Class 1 Master Pump Drain for draining of the lower pump cavities, volute, and selected water-carrying lines and accessories. The all brass and stainless steel construction of this master drain valve assembly shall allow for pump operation up to 600 psi.
FIRE PUMP DRAIN DISCHARGES COMPLY _____YES NO_____
The 3/4 inch drain valves shall be equipped with 90-degree fittings to direct the discharge water beneath the pump module away from the pump operator's panel.
ANODE SYSTEM COMPLY _____YES NO_____
To reduce the effect of galvanic action, the fire pump shall be equipped with two (2) easily replaceable sacrificial catalytic action ¾" magnesium anodes. One anode is to be installed on the inlet (suction) side of the system and one anode is to be installed on the pressure (outlet) side of the fire pump.
THERMAL PROTECTION VALVE COMPLY _____YES NO_____
The pump shall be equipped with a Hale TRV-L, thermal protection device, which monitors the water temperature of the pump, and relieves water when the temperature inside the pump exceeds the preset value of the relief valve (120 degrees F / 49 degrees C). The TRV shall automatically dump a controlled amount of water to the atmosphere or back to the tank when the pump water temperature exceeds the preset value. The valve shall automatically close when the water temperature cools below the preset value.
A chrome panel placard with a visual warning lamp and test button shall be provided on the operator's pump panel. The warning light shall illuminate when the Thermal Relief Valve is open and discharging water.
SUCTION PRESSURE RELIEF VALVE COMPLY _____YES NO_____
A Class 1, 2.5" NPT, relief valve shall be installed on the suction side of the pump and be preset at 125 psi. The relief valve shall have a working range of 50 psi to 250 psi. The valve shall be of stainless steel construction, and shall include a stainless steel spring and rubber seat. The valve shall be normally closed and shall limit pressure in the pumping system. When excessive intake pressures are received, the water shall be directed below the apparatus toward the rear tires. The discharge side of the intake relief valve shall terminate in NST male adapter and labeled "Do Not Cap".
AKRON BALL VALVES COMPLY _____YES NO_____
All ball valves on the Water Tender build-up shall be manual control 1/4 turn Akron heavy duty valves with stainless steel ball, unless specified otherwise. The valves shall have an all cast brass body with flow optimizing stainless steel ball, and dual polymer seats. The valve shall be capable of dual directional flow while incorporating a self-locking ball feature using an automatic friction lock design, and a specially designed flow optimizing brass ball. The valve shall not require the lubrication of seats or any other internal waterway parts, and shall be capable of swinging out of the waterway for maintenance by the removal of eight bolts. All exposed brass valves shall be painted the standard body color; the front bumper discharge valves shall be painted silver.
LARGE DIAMETER CAP COMPLY _____YES NO_____
Two (2) 4” chrome plated NH cap with long handles shall be supplied. The cap shall be capable of withstanding 500 PSI.
LEFT SIDE STEAMER INLET COMPLY _____YES NO_____
There shall be one (1) 4” steamer inlet furnished on the left side pump panel. The suction inlet shall have an NPT thread. At the intake connection there shall be a chrome plated adapter that is a 4" female NPT to 4" male NH; a cap and removable strainer shall be provided.
LEFT SIDE INTAKE COMPLY _____YES NO_____
There shall be an intake located on the left (street) side of the pump and shall contain a 2.5" intake with a 2.5" quarter-turn swing-out valve. The inlet valve shall have a swing type control handle located adjacent to the valve. The inlet shall be provided with a 2.5" NST female swivel that extends through the pump panel. A chrome plated intake plug with plug retention chain shall be installed on the inlet to the valve. The valve shall be able to be removed from the operator's side of the pump panel by removing a brushed stainless steel trim panel. The valve shall also include a push-pull type valve that is piped to the inlet, to bleed-off pressure from the connection on the outlet side of the valve. A removable strainer shall be provided.
RIGHT SIDE STEAMER INLET COMPLY _____YES NO_____
There shall be one (1) 4” steamer inlet furnished on the right side pump panel. The suction inlet shall have an NPT thread. At the intake connection there shall be a chrome plated adapter that is a 4" female NPT to 4" male NH; a cap and removable strainer shall be provided.
RIGHT SIDE INTAKE COMPLY _____YES NO_____
There shall be an intake located on the right (curb) side of the pump and shall contain a 2.5" intake with a 2.5" quarter-turn swing-out valve. The inlet valve shall have a swing type control handle located adjacent to the valve. The inlet shall be provided with a 2.5" NST female swivel that extends through right side middle section of the pump panel. A chrome plated intake plug with plug retention chain shall be installed on the inlet to the valve. The valve shall also include a push-pull type valve that is piped to the inlet, to bleed-off pressure from the connection on the outlet side of the valve. A removable strainer shall be provided.
RECIRCULATION VALVE COMPLY _____YES NO_____ A 1.5" quarter-turn full flow ball valve and line shall be labeled and plumbed from the discharge side of the pump to the water tank to help cool the pump when it is engaged and water is not being discharged. This line shall be plumbed through a pump control panel-mounted valve and high pressure flexible piping and stainless steel couplings that is designed to bypass water when the valve is open, allowing the water inside the pump to be maintained at a safe temperature. A check valve shall be included in the line to facilitate priming.
ENGINE COOLER VALVE COMPLY _____YES NO_____
A Class 1 brass, ½", quarter turn ball valve with chrome handle shall be supplied and labeled "Engine Cooler". The valve shall be installed on the left lower forward side of the pump panel with the line running to the (Sen-Dure) auxiliary engine water cooler that is located near the engine and plumbed into the engines’ coolant system. The fire pump water system will assist in cooling the truck diesel engine during stationary pump operations. A 3/8” line will be run from the discharge side of the main pump to deliver metered water through the cooler. The cooler return line shall pass through a check valve into the water tank.
TANK TO PUMP COMPLY _____YES NO_____
The tank to pump piping shall be capable of delivering water to the pump at a rate of at least five hundred (500) gallons per minute. This flow shall be sustained while pumping to a minimum of 80% of the certified tank capacity with the apparatus on level ground. The tank to pump line shall run from the pump to the front face of the water tank and down into the tank sump. A rubber coupling shall be included in this line to prevent damage from vibration or chassis flexing. The tank to pump line shall be 3" I.D. piping with a 3" air operated ball valve or as best determined by the manufacturer. A built in check valve shall be provided in the tank to pump supply line to prevent the unintentional back filling of the water tank through the line. A guarded air toggle switch and indicator lights shall be located on the pump operator's panel for tank to pump operation. A red indicator light shall be provided when the valve is closed and a green indicator light for when the valve is opened.
Note: Requires a check valve
TANK REFILL COMPLY _____YES NO_____
A 2.5" tank refill line shall be provided using a 2.5" quarter-turn full flow ball valve controlled from the pump operator's panel with a push pull manual locking handle. The tank refill shall be plumbed with high pressure flexible piping and high pressure flexible piping stainless steel couplings.
RIGHT REAR DIRECT TANK FILL COMPLY _____YES NO_____
There shall be a direct tank fill located on the right (curb) side of the rear wall of the stainless steel water tank, and shall contain a 3" intake with a 2.5" quarter-turn swing-out valve. The inlet valve shall be painted body color and have a swing type control handle located adjacent to the valve. The inlet shall be provided with a 30 degree drop 2.5" NST female swivel. A chrome plated intake plug with plug retention chain shall be installed on the inlet, to the valve. A removable strainer shall be provided.
LEFT SIDE DISCHARGE COMPLY _____YES NO_____
There shall be a discharge located on the left (street) side of the pump and shall contain a 2.5" discharge with a swing type control handle adjacent to the valve. The discharge outlet shall have a 2.5" quarter-turn swing-out valve. The discharge shall be provided with a chrome plated 30-degree discharge fitting with 2.5" NH male threads that extends through the pump panel. A pressure cap is to be provided. The valve shall be able to be removed from the operator's side of the pump panel by removing a brushed stainless steel trim panel.
RIGHT SIDE DISCHARGE COMPLY _____YES NO_____
There shall be a discharge located on the right (curb) side of the pump and shall contain a 2.5" discharge with a swing type control handle adjacent to the valve. The discharge outlet shall have a 2.5" quarter-turn swing-out valve. The discharge shall be provided with a chrome plated 30-degree discharge fitting with 2.5" NH male threads that extends through the pump panel. A pressure cap is to be provided. The valve shall be able to be removed from the operator's side of the pump panel by removing a brushed stainless steel trim panel.
REAR DISCHARGE COMPLY _____YES NO_____
Piping to the rear discharge shall be accomplished by a sleeve that is routed through the water tank for the discharge.
REAR DISCHARGE - LEFT SIDE COMPLY _____YES NO_____
There shall be one (1) 2.5" and one (1) 1.5” discharge outlet located on the left side rear of the stainless steel water tank. The 2.5” discharge outlet shall be plumbed with 2.5" high pressure hose and have a 2.5" quarter-turn, swing out valve with direct control on the outside rear portion of the apparatus. The discharge shall be provided with a chrome plated 30-degree discharge fitting with 2.5" NST male thread on the end of the valve for fire hose connections. A pressure cap is to be provided. The 1.5” discharge outlet shall be plumbed with 1.5" high pressure hose and have a 1.5" quarter-turn, swing out valve with direct control on the outside rear portion of the apparatus. The discharge shall be provided with a chrome plated 30-degree discharge fitting with 1.5" NST male thread on the end of the valve for fire hose connections. A pressure cap is to be provided.
FRONT DISCHARGE COMPLY _____YES NO_____
One (1) 1.5" discharge shall be located at the front bumper. The front discharge shall be plumbed using a single feed of 2" stainless steel pipe and wire reinforced high pressure hose coupled with stainless steel fittings. The front discharge outlet shall have one (1) 2" quarter-turn swing out valve. The front discharge shall be provided with a 1.5" brass 90-degree swivel adapter with 1.5" NH male threads. A pressure cap is to be provided. The valve for the center front bumper hose well shall be located on the left side of the front bumper outboard of the frame rail, and be vertically mounted within the bumper and controlled at the valve.
The discharge swivel location shall provide adequate clearance for the use of a 1.5" gated wye, and be designed so as not to interfere with the opening and closing of the hood. The swivel shall feature a stop to prevent it from rotating 360 degrees and impacting the hood. An inline 1/4 turn valve shall be mounted easily accessible beneath the cab on the left side to turn off the water supply to the front discharge. Drains shall be provided in the low points in the plumbing to drain water. One 1.5”X 15 foot bumper attack line shall be included and install in a compartment behind the front bumper incorporated into the gravel shield and hooked into the wye.
FRONT CROSSLAY DISCHARGE VALVES COMPLY _____YES NO_____
One (1) discharge outlet on each side shall be located adjacent to the pump house hose lay, set back from the panel edge, on the left and right side. The discharge outlet shall have a 2" quarter-turn swing-out valve with a swing type control handle adjacent to the valve. The discharge shall be provided with painted brass straight discharge with 1.5" NH male threads that extends through the pump panel. A pressure cap is not to be provided. The valves shall be able to be removed from the outside of the pump panel.
FRONT & REAR SPRAY BARS COMPLY _____YES NO_____
Two spray bar nozzles shall be located on the front bumper, on the outer corners ahead of the front tires and be forward facing. Two spray bar nozzles shall be located on the rear bumper, on the outer corners behind the rear tires and be rearward facing. The front and rear spray bar plumbing shall be constructed out of a minimum of 1” stainless pipe, properly rated braided hose with crimp fittings, and be mounted in a location which will maximize the effectiveness of the nozzles while providing the best protection from foreign objects and debris. All the plumbing shall include drains at the low spots to prevent freezing and rubber hoses in locations needed to compensate for chassis flexing. The braided rubber hoses shall utilize a crimp style fitting and be rated for the appropriate pressure.
Four Stainless steel Bete 1 X 1SJ 1” bulk head style mount with NF40050 swivel spray nozzles will be supplied and installed to maximize the available spray pattern. Two nozzles will be mounted on the front spray bar on the outer corners of the vehicle ahead of each tire to maximize the available spray pattern. Two nozzles shall be mounted on the rear bumper on the outer corners of the water tender behind the rear tires.
The front and rear spray nozzles shall be independently controlled from the cab utilizing one Jamesbury VPVL051DABD or equivalent, electric control valves each. The rear control valve will be located under the cab in an easily accessible location and will control the rear spray bar. The front control valve will be mounted in the engine bay near the front of the chassis in an easily accessible location and will control the front spray bar. The electric control switches will be located in the center console with the appropriate labels. Location to be determined at preconstruction.
Final design and location of the spray bars will be determined at a pre-construction meeting.
TANK DRAIN COMPLY _____YES NO_____
A 2" tank drain shall be provided on the bottom of the main tank in the tank sump. The drain shall be provided with a 2" 1/4 turn Akron ball valve and located near the rear of the vehicle. The valve shall include an adapter to 2.5” male NH threads with a cap to prevent unintentional draining. This drain shall include a labeled external locking push pull manual locking handle to operate the valve from the side or rear of the water tender.
BODY FABRICATION
FABRICATION DETAILS COMPLY _____YES NO_____
The apparatus being purchased is expected to have an 18 to 20 year service life. Based on this requirement, the department is extremely concerned that the apparatus remains structurally sound and the outward appearance remains in a “like new” condition, with minimal maintenance and upkeep, throughout the intended service life. In order for the vendor to meet our agency requirements, all details of fabrication shall be maintained as per these specifications, including the prototype vehicle, and per the approved contractor's supplied drawings. The contractor shall make all allowances for obstructions to fabrications as required by variations in the chassis. Minor details of construction and materials that are not otherwise specified in this specification are left to the discretion of the contractor, who shall be solely responsible for the design and construction of these components.
APPARATUS BODY DESIGN AND CONSTRUCTION COMPLY _____YES NO_____
The apparatus body shall be built and designed exclusively for Fire Service use. The overall body width shall be 98 inches wide and shall be constructed in accordance with current NFPA requirements. All metal work shall be free of sharp edges, objects or corners. No exceptions are allowed to this requirement. The engineering and testing techniques shall have been performed with special attention given to fatigue life and structural integrity of compartments and body support system. The apparatus body shall be designed with the use of parametric modeling engineering software to ensure proper design of panel cuts and alignment of holes in mating parts. The entire apparatus body shall be a precision laser cut, fully-welded construction, properly reinforced with integral flanges eliminating the need for additional structural shapes. Hose body fabrications shall be free of all internal projections which might injure personnel or damage fire hose.
The pump module is to be completely separate from the main body to prevent damage due to flexing.
QUALITY COMPLY _____YES NO_____
All material and equipment shall be new and unused. All bolts other than stainless steel shall be a minimum of zinc-plated, heat-treated, "SAE Grade 5", of proper length. Exceptions shall be where Grade 8 bolts are specified. All threaded nut fasteners will be self-locking “Nylock” nuts or will have lock washers. Any original equipment manufacturers special design bolt (i.e., SAE Grade 8, flanged head, long shoulder bolt) that is removed from the chassis during fabrication shall be reinstalled or replaced by the same type and grade, and shall be properly torqued to the manufacturer’s specifications.
All welds involved in the fabrication process shall be free of slag, internal and external, and all exposed outer surface welds shall be ground smooth. All workmanship, welding, cutting, fabrication, and assembly shall be of high quality, and in conformance with best manufacturing practices. All welding shall be according to ANSI and AWS standards. Flame cut edges will be ground smooth and finished for a neat and uniform appearance. No welding or cutting will be permitted on the basic chassis without the designated NDF Representative's approval. All brackets, braces, fittings and other attachments will be bolted to the frame or chassis. Existing holes in the standard truck frame shall be utilized wherever possible. If additional bolt holes are required, they shall be drilled through the web of the frame, at least twice the "hole" diameter distance from the start of the frame flange radius. The top and bottom of the frame rail will not be drilled through in any circumstances. Securing of air, coolant, fuel and electrical lines, looms or harnesses will not utilize plastic clips or bands. Only insulated metal loops, clips and/or devices are acceptable for the fire service. Plastic looms underneath the vehicle will be protected with Storm King heat wrap sheathing.
MODULAR BODY REQUIREMENTS COMPLY _____YES NO_____
The body shall be modular in design allowing transfer of body components to a new chassis in the event of an accident or wear. Body components shall be removable from chassis without cutting or bending. The modular design shall also facilitate ease of repair or replacement of major body parts. The mounting of the apparatus body shall be separate and distinct from the water tank mounting and the pump module mounting. The body compartment floors, rear walls and roof areas shall be constructed of 12-gauge stainless steel or aluminum. The vertical front and rear walls are to be designed with 14-gauge stainless steel or aluminum. Interior and unexposed metal panels shall be #4B finish to eliminate the need for high maintenance painted surfaces in the compartments. All exterior non-painted stainless steel panels shall have #4B finish.
MATERIAL COMPLY _____YES NO_____
All sheet metal, structural metal, and formed parts, such as corner posts, doors, side rails, end members, and headers used in fabricating the Water Tender body shall be 12 gauge stainless steel or 5052-H32/3003-H32 aluminum as noted in this specification.
BRAND NAMES COMPLY _____YES NO_____
Unless otherwise stated "No Exceptions", brand names mentioned in these specifications are for reference only, and are intended for the purpose of assisting in describing the need, use, and quality of the item. The contractor will identify any alternate item(s), and it is NDF's responsibility to either accept or reject any alternative item(s).
CURRENT PRODUCTION COMPLY _____YES NO_____
The manufactured body and components shall be manufactured from current production components. The use of any used or non-current production parts is prohibited.
RIVETS COMPLY _____YES NO_____
The rivets used to attach any of the interior paneling directly to the structural sections as needed shall be Crest 304 stainless steel 1601-1613 AVX or equivalent.
Specify Mfr. & No. _________________________________
BODY SCREWS COMPLY _____YES NO_____
The apparatus body manufacturer shall use machine screws to fasten door skins, covers, protective plates and accessories to the module. Holes must be threaded, have nut-zerks, weld nuts, spring nuts, and the like to fasten items to the body. The use of thread locker or lock washers on these fasteners is required. Use of sheet metal screws including self-tapping screws to fasten panels or items to the body will be rejected.
BODY MOUNTING COMPLY _____YES NO_____
The body assembly shall be fastened to the truck chassis by means of six (6) special brackets. Designer mounting systems can be discussed further at the pre-construction conference meeting. One set shall be attached to the forward portion of the left and right body cross member and the truck frame by means of an elastomer spring with a captivated die spring mounting system with limited travel. The lower portion of this spring mounting system shall be an integral part of the pump module frame mounting system. This design allows for maximum chassis flexing without undue stress transfer to the apparatus body.
The four (4) additional mounting brackets manufactured from .25" plate (two on each side) shall be welded to the body supports just aft of the wheel wells and near the right and left side rear compartments to the chassis frame extensions by means of an elastomer spring mounting system, with extended travel captivated die spring to form a modular integral body support system. The upper brackets shall be welded to the body frame and each lower bracket shall be bolted to the truck frame with a minimum of two 1/2" grade eight bolts, washers and self-locking nuts. The fabricated mounting brackets shall be manufactured from a minimum of .25" plate and have all seams or joints welded on both sides.
Full length 3" x 1" x 80” shore rubber filler strip is required between the longitudinal sills and the top of the truck frame to maintain at least 20" of clearance between the ground and the lowest underbody compartment. The filler strips (bonded to the rubber) shall be welded to the body longitudinal tubing.
The apparatus body shall not rest upon the chassis truck rails and must be separated entirely from the steel frame of the chassis to prevent galvanic action.
Loose fitting U-bolt body mounting systems are not acceptable due to the likeliness of the apparatus body shifting, flexing, or becoming detached from the chassis upon rear end impact.
BODY FLOORING CONSTRUCTION COMPLY _____YES NO_____
The fabricated body floor shall be made from either 12-guage stainless steel or aluminum. All sub floor seams shall intersect at the cross members. The floor seam layout of the body shall be discussed at the pre-construction conference.
TANK MOUNTING COMPLY _____YES NO_____
A tank mounting cradle shall be supplied. The tank mounting cradle shall consist of a minimum of five (5) cross members and four (4) full tank length longitudinal members. The tank shall rest on the tank mounting sub frame, and shall be insulated from the sub-frame with a 2.5" wide rubber insulator. The tank shall sit cradle-mounted using four (4) corner angles of 8" x 8" x 4" x .250" welded directly to the tank sub-frame. The angles shall keep the tank from shifting left to right or front to rear. The tank is designed on the free-floating suspension principal and shall not require the use of hold downs. The tank shall be completely removable without disturbing or dismantling the apparatus body structure. The water tank cradle shall be designed to be completely independent of the apparatus body to eliminate torsional stress loading in the body. The tank cradle shall be mounted with captivated die springs on the four corners to allow the cradle to move independent of the twist of the truck chassis. No exception will be permitted to the tank mounting requirements.
Note: New "U" shaped rubber extrusions for the center rails are to be installed.
COMPARTMENTS AND STORAGE
The compartment dimensions may vary to accommodate batteries, exhaust system, etc. The final dimensions and configuration will be as approved by the designated NDF Representative. On all exterior storage compartments, dual LED Strip lighting at a minimum shall be provided. The sheet metal for the compartment doors shall be 12-gauge aluminum. Exterior storage compartment doors shall have a gas pressurized door control. The doors shall be flush-fitted with a reinforced cross section(s) and equipped with weather proof recessed automotive closed cell door seals fastened to the jamb. All compartment doors shall have bolt on heavy duty polished stainless steel continuous type hinges, (1/4" pins and 1" joint length).
All compartment door latches shall be polished stainless steel bolt-in “D” style with 5° bent rotary handle recessed latches that are keyed to match the other body locks.
All compartment floors and shelves shall be fitted with removable Turtle Tiles (black or grey in color) or equal material formed to cover the complete floor area. The leading edge of all compartment doors will be equipped with reflective red & white tape. The compartment mounting for each individual compartment shall be welded to the main body. Self-tapping screw or bolts are not acceptable. All main body storage compartments shall be vented to the outside with “Weber” style stainless steel rotary vents. The vent locations shall be approved by the designated NDF Representative.
******
COMPARTMENT SHELVING COMPLY _____YES NO_____
The vehicle shall include adjustable aluminum shelves that are to be installed and have flanges that are 2" deep with a material thickness of .188". A channel support bracket shall be provided along the bottom center of each shelf. Each shelf shall be fully adjustable in height and held in place by extruded uprights. Conspicuity tape with a red/white reflective stripe shall be applied along the length of the front face of all adjustable shelves.
NOTE: Each compartment listing in these specifications contains specific details on the shelving that is required.
COMPARTMENT ROOF CONSTRUCTION COMPLY _____YES NO_____
Each compartment top shall have a 12-gauge aluminum roof section for supporting roof loads of up to 500 pounds per square foot without permanent roof deformation. The aluminum roof sections shall attach the compartment rear wall and compartment vertical sides through a welded joint creating a full perimeter compartment attachment of the aluminum roof section.
RIGHT FRONT EXTERIOR STORAGE COMPARTMENT COMPLY _____YES NO_____
The Water Tender shall include a right front exterior storage compartment on the pump body below the cross lay. It shall have approximate dimensions of 22" wide x 18" high x 24” deep or as best determined by the manufacturer to utilize the available space. The clear door compartment dimensions shall be approximately 20" wide x 16" high as best determined by the manufacturer. The compartment door shall be hinged vertically on the right hand side, open from the left to the right, and be designed to have a sweep out floor. The compartment shall have four (4) vertical unistrut sections added to the interior wall for mounting of a storage shelf. An aluminum storage shelf shall be provided. A compartment width stainless steel scuff plate shall be provided below the storage compartment to protect the body from damage. The top edge of the scuff plate shall be 90 degrees to cover the door threshold.
There shall be two large removable panels provided on the inside of the compartment, one on the floor of the compartment and one at the rear of the compartment. These panels shall provide an opening for service access to the right side of the interior of the pump module. The single 12-gauge aluminum flush fitted compartment door shall be appropriately sized, as best determined by the manufacturer, and shall be equipped with recessed weatherproof automotive closed cell door seals, and additional rubber seals on the door frame shall be provided.
Dual LED Strip lighting shall be provided controlled by a door actuated switch in all compartments.
Specify Compartment Dimensions _________________________________
MID-SHIP EXTERIOR COMPARTMENTS COMPLY _____YES NO_____
The two side forward corner storage compartments shall be fabricated into the front of the body directly behind the fire pump panel. The front exterior storage compartment shall have hinged exterior door. The full length hinges shall be mounted on the front of these compartments. The left compartment shall have four (4) vertical unistrut sections added to the interior wall for mounting of the storage shelf. The right and left hand compartments shall have a full size slide out tray mounted to the floor. A compartment width stainless steel scuff plate shall be provided below the storage compartments to protect the body from damage. The top edge of the scuff plates shall be 90 degrees to cover the door threshold.
The compartment on the left hand side shall be a full height and full depth compartment in front of the rear wheels. It shall have approximate dimensions of 34.5” wide x 28.75" high and 24” deep. The clear door compartment dimensions shall be 32.5" wide x 25.75" high x 24" deep. The left hand compartment shall have a full size slide out tray mounted to the floor to gain access to the contents.
The compartment on the right hand side shall be a full height and full depth compartment. It shall have approximate dimensions of 34.5” wide x 28.75" high and 24” deep. The clear door compartment dimensions shall be 32.5" wide x 25.75" high x 24" deep. The right hand compartment shall have a full size slide out tray mounted to the floor to gain access to the contents.
Dual LED Strip lighting shall be provided controlled by a door actuated switch in all compartments.
Specify Compartment Dimensions Left Side _________________________________
Specify Compartment Dimensions Right Side_________________________________
REAR SIDE-CORNER EXTERIOR COMPARTMENTS COMPLY _____YES NO_____
The two (2) side-rear corner storage compartments shall be fabricated into the rear of the body, and will include an aluminum adjustable shelf in the storage compartment. The rear exterior storage compartment shall have hinged exterior door. The full length hinges shall be mounted on the front of these compartments. The compartment shall have four (4) vertical unistrut sections added to the interior wall for mounting of the storage shelf. A compartment width stainless steel scuff plate shall be provided below the storage compartments to protect the body from damage. The top edge of the scuff plates shall be 90 degrees to cover the door threshold.
The compartment on the left hand side shall be a full height and full depth compartment behind the rear wheels. It shall have approximate dimensions of 26.5” wide x 22.75" high. The clear door compartment dimensions shall be 24.5" wide x 19.75" high x 24" deep.
The compartment on the right hand side shall be a full height and full depth compartment behind the rear wheels. It shall have approximate dimensions of 26.5” wide x 22.75" high. The clear door compartment dimensions shall be 24.5” wide x 19.75" high x 24" deep.
The approximate size of these compartments shall be full height floor to ceiling dimension that shall be best determined by the manufacturer to meet angle of departure requirements.
The two (2) 12-gauge aluminum flush fitted compartment doors on each side shall be appropriately sized, as best determined by the manufacturer, and shall be equipped with recessed weatherproof automotive closed cell door seals and additional rubber seals on the door frame shall be provided.
Dual LED Strip lighting shall be provided controlled by a door actuated switch in all compartments.
Note: The rear compartment is raised to meet a minimum 20° angle of departure critical to the mission of this equipment. Angle reinforcement is to be added to the bottom of the rear compartment.
Specify Compartment Dimensions Left Side _________________________________
Specify Compartment Dimensions Right Side_________________________________
REAR EXTERIOR COMPARTMENT COMPLY _____YES NO_____
Dual LED Strip lighting shall be provided controlled by a door actuated switch in all compartments.
Specify Compartment Dimensions _________________________________
HARD SUCTION HOSE STORAGE COMPARTMENT COMPLY_____YES NO_____
The hard suction hose storage compartment shall be fabricated out of tread bright aluminum and installed above the left side main body. This exterior storage compartment shall be accessed from the front of the vehicle, with a single access door. The door shall be recessed and equipped with weatherproof automotive closed cell door seals. This compartment will include an aluminum shelf that permanently divides the storage compartment, in order to store two (2) 10’ X 4” hard suction hoses, two (2) 10’ X 2.5”, and two (2) 10’ X 1.5” hard suction hoses. These hoses may be able to be stored in each other to save space. A compartment width stainless steel scuff plate shall be provided below the storage compartments to protect the body from damage. The top edge of the scuff plates shall be 90 degrees to cover the door threshold. The approximate size of this compartment shall be determined by the manufacturer.
Specify Compartment Dimensions _________________________________
3000 GALLON FOL-DA-TANK WITH ZICO HYDRAULIC LIFT COMPLY _____YES NO_____
A Zico PTS lifting system with an integrated full length stainless steel cover shall be mounted on the right side of the apparatus above the main body, beside the water tank. The main body must be reinforced to withstand the added stresses of the lift and tank. The lift will be properly sized to handle a FDTA 3000 Fol-Da-Tank. The lift shall not come in contact with the side of the apparatus while in the lowered positon and provide proper support for the tank. The control switch shall be located on the right side pump panel and shall include an arming switch and an armed warning light. The operator must be able to see the unit at all times while being operated. The unit must also be tied into the open compartment warning light on the console to warn the operator if the unit is in the lowered position.
A Fol-Da-Tank model FDTA3000-22VW/30oz vinyl Floor shall be included in the bid and mounted inside the Zico lift. The tank shall yellow in color and be constructed out of the 30 ounce vinyl material. The frame shall be aluminum to reduce the overall weight of the tank.
FRONT CROSSLAY HOSE BED STORAGE COMPARTMENT COMPLY_____YES NO_____
The front cross lay hose bed storage compartment shall be fabricated and installed above the main pump module, at the top front portion of the body build-up, and be accessible from both the right and left sides of the vehicle. They shall be arranged in a single stack design with two adjustable center dividers in the storage area in order to create three separate adjustable vertical storage compartments. Each storage area shall extend from the side of the pump module to the center of the storage with approximate dimensions of 22” wide x 18” tall or as best determined by the manufacturer to maximize the use of the available space above the pump panel. The hose bed shall be large enough to accommodate 150 ft. of 1.5” fire hose. The floor of the hose storage area shall contain drain holes to allow drainage. Brushed stainless steel hose guides shall be provided on the left and right side of each pump house hose bed. This exterior storage compartment shall be accessed from the top of the vehicle, and be equipped with a single flip-open top access door that is complete with full-length stainless steel piano hinge. The door shall swing open and up from the rear of the vehicle, towards the cab. The door to this compartment shall be equipped with a rubber plunger door hold device, to hold the door in the open position. The door shall not swing into the top of the cab of the vehicle. An installed door check device shall be installed to prevent this from happening. Small hand holds shall be provided at each side of the door.
The cross lay hose bed compartment shall include a stainless steel scuff plate at both the right and left side of the vehicle at the bottom of the compartment, to protect the body from damage when hose is deployed out the sides of the vehicle.
The sides of the cross lay top access compartment door shall be outfitted with weighted NFPA compliant vinyl flaps to protect stored hose from the elements. Hose bed covers shall be suitable for use by the fire service. The hose bed covers shall be outfitted with adjustable latches. The vinyl cross lay end flaps shall be black in color.
A single latch able 5052-H32 or 3003-H32 Tread bright aluminum fitted compartment door shall be appropriately sized and provided, as best determined by the manufacturer.
The compartments shall be equipped with a smooth perforated aluminum mesh grate on the floor of the compartment that is slip-in, and easily removed for cleaning. This will help prevent stored hose from molding.
LED lighting is to be provided for the inside of this compartment to provide light for night operations. LED Strip lighting or small round LED lighting with a rubber grommet can be installed throughout the compartment, or as best determined by the manufacturer.
Specify Compartment Dimensions _________________________________
CHOCK BLOCKS STORAGE COMPARTMENT COMPLY _____YES NO_____
Two (2) storage compartments shall be fabricated and located between the rear wheel wells, on the both sides of the vehicle for deployment of the two (2) aluminum chock blocks. A compartment width stainless steel scuff plate shall be provided below, above, and to the sides of the storage compartments to protect the body from damage. The top edge of the scuff plates shall be 90 degrees to cover the door threshold. The approximate size of this compartment shall be best determined by the manufacturer. LED Strip lighting is not required.
Specify Compartment Dimensions _________________________________
NOTE: ALL of the compartment doors that will have the potential to strike other painted surfaces shall have rubber bumpers installed in the contact areas. These storage compartments shall be discussed during the pre-construction conference.
FIRE PUMP COMPARTMENT COMPLY _____YES NO_____
The pump compartment shall be separate from the hose body and compartments so that each may flex independently of the other. It shall be a fabricated assembly of heavy-duty stainless steel or aluminum tubing and angles, which does not support the fire pump. The pump compartment shall be mounted onto the chassis through rubber bushing assembly in a four point pattern to allow for the chassis frame to flex as needed. The pump compartment shall be a modular design, allowing its removal from the chassis in an assembly that is complete with pump, plumbing, and gauges; with an approximate width of 24".
GENERAL BODY FABRICATION COMPONENTS
DOOR HOLDERS & DOOR CHECKS COMPLY _____YES NO_____
The exterior compartment doors shall be provided with a suitable device or means to control and hold the doors in the open position, and not allow the door to contact the side body. Gas pressurized shocks with metal rod ends will be accepted. This type of door control system is preferred for use in the design and build of NDF fire equipment.
DOOR LATCHES COMPLY _____YES NO_____
The main exterior compartment door latches shall be flush mounted, stainless steel, Austin Hardware or Hansen rotary “D” ring style latches with a 5-degree bend for easier grasping of each door handle with gloved hands. These latches shall be provided with a keyed lock, and shall include rotary latch striker posts or equivalent. The door striker shall be adjustable and secured with a nut from behind door frame. The striker washer will not be removed. Cold rolled, threaded 0.162" steel rods shall be used to activate dual rotary latches. Once final adjustments to latches are made, threads are to have Loctite or equivalent applied. All double door compartments shall have an exterior stainless steel rotary handle and rotary latches on the forward door. The forward doors will latch into the door frame mounted striker posts, and will hold closed the secondary compartment access door, or as best determined by the manufacturer. All compartment doors shall be keyed alike on each vehicle. Each vehicle manufactured should be keyed differently from one another if possible.
Specify Door Latch Mfr. & No. _____________________________
DOOR HINGES COMPLY _____YES NO_____
All compartment door hinges shall be full length, piano type, stainless steel hinges, 2.5" wide with a 0.25" pin. The hinges shall be attached with 12 x 3/4 stainless steel truss head screws spread 4" apart and staggered 0.5" horizontally for additional strength and adjustability. Hinges shall be staked every 4”. All curbside and street side doors shall be hinged on the forward sides, unless a double door is specified. Hinges shall be attached to the door and to the body with a reinforced nut, washer and bolt system at the top and bottom of the hinge.
DOOR SEALS COMPLY _____YES NO_____
Each doorframe will have a 0.875" flange for the installation of an air cell hollow core, 360-degree compression door seal. This seal creates watertight, dust-free compartment integrity. Door seal shall be knock-on type.
THRESHOLDS COMPLY _____YES NO_____
All compartment doorframes shall have full width formed stainless steel threshold plates to protect the lower edge of the frame.
WHEEL WELLS COMPLY _____YES NO_____
Shall be 10-gauge aluminum. Tire clearance shall be 4" minimum loaded to allow the installation of tire snow chains.
MISCELLANEOUS COMPONENTS
DRIVER’S CONSOLE COMPLY _____YES NO_____
A storage console shall be installed between the two front seats in the cab of the vehicle, and made of formed aluminum and finished with black powder coating. The console shall have a removable top and front panel. The console shall be vented to allow heat dissipation from the electrical components mounted within. The electrical fuse/breaker panel shall be mounted to the front side of the console and be provided with a protective lid that contains a legend for the breaker functions. The console shall be the maximum size that will fit between the front bucket seats, while ensuring allowances for seat belt access, engine doghouse removal, and rear seat leg room. The overall height shall not exceed the height of the front seat cushions. The customer-supplied Bendix King digital DPH 2-way communications radio will be located in this console. Provisions shall be made to install the cab headset communications system and the 2-way radio, which includes the antenna coax (2) and the proper fused power and ground wires. An LED map light shall be installed in the upper right corner. A (3) outlet/accessory plug shall be installed on the right front side of the console. The console shall also have backlit switches with engraved labels with a layout to properly identify component and accessory function, and will also be outfitted with a map holder with three (3) dividers that are fabricated out of mill-finished aluminum. The console form/map box will be of the following dimensions: 13.5" deep x 20.75" wide x 14" front to back. This box is sized to utilize the maximum space available and that is deep enough to house 8.5" X 11" binders with two (2) full length adjustable dividers. The map holder portion of the console shall be covered with a lockable, black powder coated cover. A Bendix King hand-held radio charger holder shall be mounted on the front of the center console. This holder shall be powder coated black to match the console. The holder shall be mounted low enough so the hand-held radio charger body does not protrude above the top surface of the center console. A Whelen P46HHS hand held LED spotlight shall be hard wired into cab console, and mounted in a convenient location for use. A heavy duty stainless steel J-hook for mounting the light shall be provided on the front of the console. The console shall be bolted to chassis floor with .25” bolts, washers, and nylock nuts.
The following components shall be mounted in the cab console top panel:
• Whelen CenCom Siren Controller
• Bendix King 2-way Digital Radio
• Whelen Rear Amber Traffic Advisor Controller
• PTO Pump Shift Control to Include Switch Guard, Indicator Light, and Identification Tag
• Water Tank Level Gauge
• Foam System Remote Control
• Intercom Control
The following accessory switches shall be mounted in the cab console top panel and engraved with the proper function:
• Ground Lights
• Pump Panel Lights
• Hose Bed Lights
• Front spray bar control
• Rear spray bar control
• Spare
The following accessory indicator lights shall be mounted in the cab console top panel:
• Compartment Open/Fol-Da-Tank down (Red)
LICENSE PLATE BRACKET COMPLY _____YES NO_____
The rear license plate bracket at the rear of the vehicle must be recessed into the storage compartment on the right rear side of the vehicle.
SPARE TIRE CARRIER COMPLY _____YES NO_____
A ratchet type cable lift spare tire carrier shall be provided and installed under the chassis frame aft of the rear axle. The use of the vehicle’s lug wrench shall be the mechanism to raise and lower the spare tire. The spare tire shall be secured to the body assembly in the raised position with four (4) "right hand thread" wheel studs and supplied lug nuts of the same OEM type and style that match the vehicle. Access to the ratchet assembly will be at the rear of the vehicle. An access door cover shall be provided to cover and protect the ratchet assembly.
FRONT BUMPER COMPLY _____YES NO_____
The OEM front bumper can be retained as long as it provides access to the front recovery tow hooks, side warning lights, and the front discharge valve assembly. These options are listed specifically in their respective sections. The front bumper must have access cutouts installed into the front face of the bumper for the operator to be able to control the discharge valve that which is located directly behind the front bumper. The front bumper must also provide a location to mount the front spray nozzles.
CAB GUARDS, EMISSIONS BURN PROTECTION, RIGHT SIDE COMPLY _____YES NO_____
The right, passenger side of vehicle’s cab shall be equipped with perforated stainless steel guards and trim edge. The trim edge is fastened directly to the cab below the doors. The stainless steel guards are to be fastened to the top ledge of the cab entry steps. The upper edge of the stainless steel guards are to be bent inward, to allow for the flex of the vehicle’s cab, as the cab rides on an air bag suspension system. The cab shall not strike these guards when the cab air bag suspension system is deflated. The guards will protect hands and feet from accidentally contacting the exhaust system piping, catalytic converter, and regeneration filter.
DRIP RAILS COMPLY _____YES NO_____
Shall be aluminum, run down the entire length of the large side compartment structure on both sides of the body above the compartment doors. Drip rails shall be integrated into the aluminum tread plate top cap of the body. All drip rails shall be finished with 45 degree angled ends to avoid hooking foreign debris which brush against the vehicle causing damage.
SIDE VEHICLE STEPS COMPLY _____YES NO_____
The vehicle shall be equipped with aluminum tread bright steps that are placed on each side of the vehicle, below the pump panel. The vehicle shall be equipped with two (2) Cast Products fixed steps with integral hand hold installed on each side of the pump panel. The steps shall have an open grate design for self-cleaning. They shall be placed the pump panel for the vehicle occupants to safely reach the top of the cross-lay and storage rack. Specific construction design and placement shall be discussed at the pre-construction conference.
REAR VEHICLE BODY STEPS COMPLY _____YES NO_____
The vehicle shall be equipped with two (2) Cast Products fixed steps with integral hand hold installed on the rear of the apparatus body. The step shall have an open grate design for self-cleaning. They shall be placed on the rear of the vehicle on approximately 24” from the side and mid height, on the rear valence, for the vehicle occupants to safely reach and access the ladder and top of the tank. Specific construction design and placement shall be discussed at the pre-construction conference.
AIR COUPLING COMPLY _____YES NO_____
One (1) automotive style standard air chuck with a dust cover shall be provided on the rear of the cab area or on the fire pump panel. A protective guard shall be installed to protect the air chuck from feet or falling tools. A valve shall be installed at the air tank to shut-off air supplied to the coupler if necessary; at or below 60 psi.
FRONT VEHICLE RECOVERY / TOW EYE COMPLY _____YES NO_____
The front recovery tow loop shall be a single hoop in the center of the front bumper. The factory loop style will be acceptable for this build.
REAR VEHICLE RECOVERY / TOW EYE COMPLY _____YES NO_____
Two (2) rear vehicle tow eye shall be constructed of .750” thick x 9” steel plate and securely attached to the left and right frame rails at the rear of the chassis frame extension. The hole diameter of the rear tow eye is to have a center opening with a dimension of 4".
AIR HORN COMPLY _____YES NO_____
The OEM mounted air horn shall be relocated to the front bumper area (if not already located there) and controlled by a switch on the steering wheel, a switch on the fire pump panel, and by a foot switch mounted on the cab floor on the passenger side of the vehicle. The horn supply line shall be loomed and properly clamped the entire length. If no OEM air horn is supplied with the chassis, a Grover model #1710 stutter tone horn shall be provided.
Specify Horn Mfr. & No. _________________________________
AIR INTAKE SCREEN COMPLY _____YES NO_____
An ember screen (stainless steel) shall be installed on the vehicle’s fresh air intake system and outside cab vent. The air intake and cab vent shall be protected as to prevent water and particles greater than .039 inches in diameter from entering the air intake system. Particular attention is required on screening of the remote through the hood style air intake systems. NO EXCEPTIONS TO THIS REQUIREMENT WILL BE ACCEPTED.
DRIVELINE SAFETY HOOPS COMPLY _____YES NO_____
Bolt on driveline safety hoops shall be provided on the forward portion of all multi-piece drivelines. The hoops shall be fabricated from steel and are secured to the lower body sills with grade 8 bolts and locking washers or nuts. NO EXCEPTIONS TO THIS REQUIREMENT WILL BE ACCEPTED.
SPLASH GUARDS COMPLY _____YES NO_____
Two (2) splash guards shall be mounted behind the front wheels and two (2) splash guards shall be installed at the rear of body in conformance with Title-49 FMCSS standards. The splash guards shall be plain black with end weights and be mounted at a distance to the back of the wheels to preclude flaps from being carried into the tires when backing into brush, etc.
SPECIAL GUARD COMPLY _____YES NO_____
If the OEM windshield washer bottle on the International 7400 is located in the left front wheel well housing, and is susceptible to being damaged from flying rocks and debris from the rotation of the front tire, the washer bottle shall be protected with a metal plate, and shall have a narrow vertical cut-out where the plate directly covers the washer bottle, so the fluid level can be easily viewed by the vehicle operator during inspection.
CHOCK BLOCKS COMPLY _____YES NO_____
Two collapsible heavy-duty extruded aluminum wheel chocks measuring 8" high x 7" wide x 11.8" long shall be provided with the apparatus. Worder 7HY HD Yellow Handled Extrusions are the requested chocks. The wheel chock related mounting bracket shall also be provided. Mounting bracket shall be installed in two compartments located within the rear wheel well, on the driver’s side of the vehicle for deployment.
SAFETY EQUIPMENT COMPLY _____YES NO_____
One (1) 10 lb. ABC portable fire extinguisher with permanent mounting bracket must be installed near the driver’s seat. One (1) three piece bi-directional emergency reflective triangle set must be installed in cab.
ADDITIONAL EQUIPMENT COMPLY _____YES NO_____
One (1) 33MM wheel lug wrench and related handle; one (1) 20-ton bottle jack and related handle; and one (1) heavy-duty set of jumper cables shall be provided.
LIGHTING AND ELECTRICAL SYSTEM
GENERAL BODY FABRICATION ELECTRICAL WIRING COMPLY _____YES NO_____
All vehicle wiring is to be "Cross Link Polyethylene" heat resistant type that meets SAE J1128 type SXL wiring guidelines. The wiring shall be loomed, grommets installed, and routed the maximum distance away from possible high heat sources, and properly clamped to the body or frame members to preclude chaffing on other components. Only insulated metal loops for electrical wiring mounting are acceptable for the fire service. Where holes are cut into the body structure for wiring, they will have the hole circumference filed smooth with grommets installed. The wiring as per the vendor supplied wiring schematic shall be function coded at both the device that the wire is attached to, in addition to the wire connected to the device that controls the circuitry of the wire. The lighting, and warning buzzer is to be a minimum of 14-gauge. The 12-Volt wiring from the truck to the junction box is to be a minimum 4-gauge cable, which is protected with a 150-amp resettable circuit breaker. A Cole-Hersey #24059 relay shall be used to activate the main power circuit; it shall be activated from the accessory terminal on the ignition switch to minimize battery drain from unimportant accessories left on while the vehicle’s engine is not running. This does not include the 2-way communications radio. Battery cables shall be AWG size 2-0 with crimped terminals with the respective colored heat shrink tubing protecting the terminals from arching and corrosion. An as-built wiring schematic must accompany each unit upon delivery. NO EXCEPTIONS TO THIS REQUIREMENT WILL BE ACCEPTED.
All uninsulated terminals AWG size 0-4/0 (starter and battery) shall be square crimped with a Roto crimp tool (AMP Special Industries # 600850-1). The crimp area and wire will be sealed with heat shrink tubing to protect it from moisture and strain relief. Soldered terminals and connectors are not acceptable.
All wiring circuits will terminate in a weatherproof junction box (Signal-Stat # 3120) or equal, and shall be located under left front corner of body to allow main body removal from the chassis. The electrical system protection shall incorporate the use of self-resetting circuit breakers in lieu of fuses.
NOTE: If any toggle switches are used for the build-up, they shall have screw terminals. Spade-type terminals are unacceptable. All cab switches shall be self- illuminating, and are to be labeled to their function with engraved I.D. plates, and fastened with machine screws and self- locking nuts or rivets. Adhesive backed I.D. plates are not acceptable.
All lights shall be provided and installed with backing plates where necessary, and shall also be wired, protected, flashed, and switched as per the job description. The turn signal and hazard switch assembly supplied with the truck chassis may require that the flasher be upgraded by the contractor to meet LED operation and/or electrical load requirements. All emergency lights and design will be NFPA approved. All marker lights, clearance lights, turn signal lights, headlights, stop lights, etc. must meet FMCSA standards.
ELECTRICAL INTERFACE COMPLY _____YES NO_____
The apparatus shall be equipped with a state of the art electrical interface utilizing the chassis multiplexing system as the foundation for the design. Integration of analog devices and hard wiring with logic devices shall be kept to a minimum.
MASTER BATTERY DISCONNECT SWITCH COMPLY _____YES NO_____
A Cole Hersey # 75903 battery disconnect switch with a # 82065 face plate (or equal) shall be provided and mounted on the cab floor next to the driver’s seat. A green LED battery switch-on indicator light shall be dash mounted near the key switch to alert the driver that the battery switch is either in the on/off position. This switch will disconnect all battery power to the vehicle, except to the vehicles ECM for both the engine and transmission.
AIR HORN ACTIVATION SWITCH COMPLY _____YES NO_____
A switch shall be located on the pump panel to activate the chassis air horn. The switch shall be a momentary pushbutton type switch with a red cover. The switch shall be supplied with the proper identification label.
COMPARTMENT OPEN LIGHT COMPLY _____YES NO_____
A Red Open Compartment Flashing Light, Whelen OS Series LED shall be mounted on the face of the vehicle’s center console. A chrome flange is to be supplied with the light. A label shall be applied adjacent to the light that reads: “OPEN COMPARTMENT'. An audible buzzer shall be provided and activate when the parking brake is removed, and a compartment is left open. The compartment open light circuit shall be wired to all compartment doors including the cross-lay covers and the Fol-Da-Tank lift in the down position.
PUMP PANEL LIGHTING COMPLY _____YES NO_____
The fire pump panel shall be illuminated by strip lighting and automatically activated when the vehicle is placed into “pump”, and/or when the pump panel light switch is turned to the “ON” position on the fire pump panel. A protective stainless steel louver placed above the pressure gauges, instrument cluster, and foam control will house the LED strip lighting. This pump panel lighting system and protective cover will also be installed on the right (passenger) side of the vehicle’s pump panel.
STORAGE COMPARTMENT LIGHTING COMPLY _____YES NO_____
All truck body storage compartments shall be illuminated by strip lighting and activated when each individual compartment door is opened. The storage compartments lights shall be Truck-Lite (or equal) LED strip lighting. A minimum of two (2) LED compartment lights shall be provided for each body compartment. Any wiring loom and switches inside any compartment shall be protected using a removable metal guard, in order to avoid damage from contents shifting during transit. Lights shall be wired to the master battery disconnect switch, or as specified by the manufacturer.
WORK AREA LIGHTING COMPLY _____YES NO_____
Six (6) flush mounted LED work lights shall be installed on the stainless steel brackets welded to the water tank. Two (2) lights on each rear corner of the vehicle, and two (2) lights on both the right and left sides of the water tank. The side work lights shall be installed on the upper forward and rear sides of the stainless steel water tank. The rear work light brackets will be large enough to share bracket space for the rear upper red LED warning lights. The work lights shall be switched through the siren control and the fire pump panel. One switch each will operate the light pairs on each side and rear of the vehicle, independently from one another. Whelen M9V2R Series Linear Super-LED surface mount clear lights are to be provided. The light bar side scene lights will illuminate with each side pair of work lights.
GROUND LIGHTING COMPLY _____YES NO_____
Underbody ground lights shall be provided under the Water Tender. Eight (8) LED Truck-Lite ground lights shall be installed: Two (2) under the cab by each cab door, two (2) mid-ship underneath the body, two (2) at the rear of the vehicle underneath the body, and two (2) underneath the vehicle’s front bumper. Both cab lights will come on when either cab door is opened. Exterior ground lights shall illuminate when either switch on the console or fire pump panel is turned to the “ON” position. Different light design variations and mounting locations can be discussed at the pre-construction conference.
TAIL, STOP, TURN SIGNAL, AND BACK-UP LIGHTING COMPLY _____YES NO_____
On the rear of the vehicle on each side, shall be one (1) Whelen 600 series lighting bracket that is to accommodate four (4) Whelen 600 series LED light heads. The lighting bracket shall contain one (1) red LED tail light/brake light, one (1) amber LED turn signal light, one (1) clear LED reverse light, and one (1) red LED emergency warning light. The red LED emergency warning light shall be affixed in the top portion of the lighting bracket. The lighting bracket is to be chrome plated.
SIDE TURN SIGNAL LIGHTING COMPLY _____YES NO_____
On the side of the main body, near the wheel well housing, a LED turn signal indicator light will be fastened to build-up. These lights will be rubber mounted using a Signal-Stat #60315Y lamp and #60700 grommet or similar.
CLEARANCE MARKER LIGHTING COMPLY _____YES NO_____
The clearance and side marker lights shall be round 2” Signal-Stat LED red #3050 rubber mounted, and Signal-Stat LED amber #3050A rubber mounted. Rubber Grommet: Signal-Stat #30401. All lights must be wired into the existing tail light circuit and mounted as follows:
• 2 each -amber, top front corner of body.
• 2 each -amber, top front side corner of body.
• 2 each -red, top rear corner of body.
• 2 each -red, top rear side corner of body.
• 3 each-red, three light cluster mounted upper center of body above the rear storage compartment.
LICENSE PLATE LIGHT COMPLY _____YES NO_____
A license plate light shall be mounted directly above the license plate mounting area on the rear of the vehicle on the right side. A Signal-Stat 26 series #26336 license plate light or similar shall be used, with a LED bulb installed.
BODY REFLECTORS COMPLY _____YES NO_____
Reflectors shall be Signal-Stat #57 or similar, center hole mount, 3" diameter and mounted as follows:
• 2 each -red, rear lower corners of body.
• 2 each -red, rear side lower corners of body.
• 2 each -amber, front side lower corners of body.
BODY CHEVRON STYLE REFLECTOR COMPLY _____YES NO_____
A portion of the rear of the vehicle shall be covered with red and yellow reflective chevron striping to meet NFPA standards. The stripes shall be 4" wide and shall alternate red and yellow. The chevron pattern shall angle up from the outer edges toward the center of the rear body. The reflective chevron decal material shall meet NFPA standards.
FRONT CAB MAP LIGHT COMPLY _____YES NO_____
An 18" rheostat controlled map light shall be provided and mounted on the console. (Federal Signal Little lite model # LF18ES-LED) or equal.
COMMUNICATIONS RADIO SYSTEM COMPLY _____YES NO_____
The contractor will supply two (2) 2-way radio antennas that shall be installed on the cab roof. The antennas will not be mounted within 18” of the vehicle’s light bar. The antennas shall be evenly spaced apart from one another and from the sides of the roof of the vehicle. The antennas shall not be within 18” of one another, as well. 15' of coax cable supplied by the contractor will connect the antennas to NDF 2-way communications radios. The cables will run to the center cab console. A 10-guage positive & negative wire (in loom) will be fully wired and fuse protected with a 20 amp fuse and made available in the center console for connection to the NDF Bendix King digital radio when it is installed.
CAB COMMUNICATIONS SYSTEM COMPLY _____YES NO_____
The contractor will supply either a Centronics or Firecom headset communications system inside the cab of the vehicle, with connections and headsets for (2) passengers. The headsets will hang above each seat within the cab of the vehicle. All positions shall have a voice activated intercom. Both front seat positions and the pump panel shall have push-to-talk radio transmit capabilities. The cab communications system shall be fully wired, and the connection shall be made available in the center console for connection to the NDF radio when it is installed. A waterproof headset connection jack shall be installed on the fire pump panel for use by the apparatus operator.
BACK-UP WARNING DEVICE COMPLY _____YES NO_____
A minimum 102 dba electronic back-up alarm shall be installed in an appropriate location at the rear of vehicle, and wired into the back-up lighting circuit.
Specify Mfr. & No. _________________________________
BACK-UP CAMERA COMPLY _____YES NO_____
The vehicle will be outfitted with an automatically activated rear-view camera. The camera system should be comparable to a ROSCO vision systems STSK7965. The camera lens shall be installed in an appropriate location at the rear of vehicle, and wired into the back-up lighting circuit to activate the system automatically. The monitor shall be mounted in a custom bracket inside the cab, below the overhead console that contains the sun visors, towards the windshield, centered in that immediate area. The custom monitor bracket shall provide a clean look, and will cover the cables or wires related to the back-up camera system.
Specify Mfr. & No. _________________________________
GROUND STRAP COMPLY _____YES NO_____
An electrical ground strap shall be installed from the fire pump body assembly to the truck frame. The ground shall be a cable equal to OEM ground cables or straps.
ON-BOARD BATTERY MAINTAINER COMPLY _____YES NO_____
A Kussmaul-type on-board battery maintainer will be installed onto the vehicle in a compartment or storage area where it will be free from the elements and protected from damage. The on-board battery maintainer will maintain the vehicle’s batteries when it is plugged-into shore power with the block heater connection.
EMERGENCY LIGHTING
EMERGENCY UPPER FRONT ZONE LIGHTING COMPLY _____YES NO_____
A Whelen Justice Series 61" light bar shall be mounted on the roof of the cab as per the manufacturer's recommendation with inside cab support structure (10 gauge steel) added for roof strength. The light bar’s clear LED lighting shall be automatically disabled when the parking brake is applied. NOTE: The light bar will be outfitted with clear dome tops and will be outfitted with alley and takedown lights. The light bar will have (1) front steady red light when illuminated. Additional front and side light bar lighting shall be full-flashing red LED lights. The rear of the light bar will have two (2) amber LED flashing lights, with the rest of the rear LED lights being red in color.
EMERGENCY LOWER FRONT ZONE LIGHTING COMPLY _____YES NO_____
Two (2) alternating synchronized red Whelen 700 Series LED lights shall be installed below the grill, and shall not restrict air flow to the vehicle’s radiator. Two (2) red Whelen 700 Series LED lights shall be installed on the right and left side of the vehicle’s hood towards the front corners of the vehicle. Lights shall have chrome bezels.
EMERGENCY SIDE REAR WARNING LIGHTING COMPLY _____YES NO_____
Four (4) synchronized red Whelen M9V Series LED warning lights/ white flood lights, two on each side, shall be mounted on the side of the water tank, in the upper most front and rear corners of the tank. The warning light shall be wired into the controller slide switch and the flood lights shall be controlled by two separate auxiliary siren controller buttons one for each side.
EMERGENCY REAR WARNING LIGHTING COMPLY _____YES NO_____
Two (2) synchronized red Whelen M9V2R Series warning/white flood light assemblies are to be mounted in the upper most corners of the water tank, at the rear of the vehicle on the stainless steel mounting brackets welded to the tank. The warning light shall be wired into the controller slide switch and the two rear flood lights shall be controlled by one separate auxiliary siren controller button.
Two (2) alternating synchronized additional amber Whelen 700 Series LED lights shall be mounted on the rear of the vehicle on both the right and left side, just below the rear warning lights.
One (1) 30” mini Whelen TIR3 8-LED light head amber directional traffic advisor shall be provided and mounted on the rear of the vehicle, centered directly above the rear lower storage compartment. Controller for traffic advisor shall be installed in driver’s console and wired to Pos. #1 on the slide switch.
HEADLIGHT FLASHER COMPLY _____YES NO_____
Two clear Whelen ION series flush mounted, synchronized led lights, shall be mounted to the outer corners of the grill, near the headlights. These lights will function as the wig wags and be programmed to come on in the #3 position of the slide switch and it shall be automatically disabled by applying the parking brake. The lights shall also incorporate a separate cut off switch that is wired into the siren control, should the feature need to be interrupted.
Specify Whelen Part # ______________________
EMERGENCY LIGHTING WARRANTY COMPLY _____YES NO_____
A three (3) year manufacturer's warranty on the light bar shall be provided. Individual warning lights shall be covered by the manufacturer for at least one (1) year.
AUDIBLE WARNING CONTROLS COMPLY _____YES NO_____
A Whelen CenCom Sapphire with the dial style control head CCSRN36 electronic siren control shall be provided. It shall have a noise canceling microphone, and shall be mounted in a manufactured console on the floor of the vehicle’s cab. A 100 watt siren loudspeaker (Whelen SA315 with mounting bracket) shall be supplied and mounted in the vehicle’s front bumper. All emergency lighting shall be controlled through the siren controller, and the takedown, left, right, and rear area work lights shall also be operated through the controller.
The siren control slide switch positions shall activate the following emergency lighting:
• Position # 1 - Rear LED amber warning lights, including traffic advisor, and light bar rear amber LED
• Position # 2 - Add light bar LED lighting, (including (1) steady red), front grill LED lighting, rear LED warning lighting, and side LED warning lighting.
• Position # 3 -Add light bar clear flashing LED lighting, headlight flasher and siren.
NOTE: The emergency lighting shall be wired through a self-resetting circuit breaker rated adequately above the required amperage draw for the circuit. Emergency lighting will have chrome bezels for surface mounting (if applicable).
FINISHING AND LABELING
GENERAL PROVISIONS COMPLY _____YES NO_____
The completed vehicle will be subject to severe wildland fire suppression use and accompanying body abrasion. However, as a new vehicle, a high quality commercial finish is required to provide the best possible foundation for finish maintenance and operator pride. All visible exterior surface areas shall be free of grinding marks, dents, peen marks, paint sag, orange peel and/or unsightly workmanship when the finished vehicle is presented for NDF's acceptance. Painting is to be applied according to the paint manufacturer's directions on properly prepared and primed surfaces.
When completed, all exterior painted surfaces of the entire main body shall be finished to be an exact color match of the OEM's commercially finished cab exterior. When completed, all exterior painted surfaces of the Water Tender body build-up shall be the single color specified gloss white. The water tank is to remain satin (industrial standard 2B finish).
MATERIALS COMPLY _____YES NO_____
The highest quality, state of the art, low V.O.C. polyurethane finishing system shall be utilized. (DuPont, PPG, Sherwin Williams, or equal). The finish coat will be applied in multiple coats to ensure proper paint coverage with a high gloss finish. Priming will be a single stage process. There will be multiple coats of catalyzed two-component polyurethane primer-surface applied for leveling of small perfections and topcoat sealing. Painted stainless steel surfaces shall use a compatible surface etching primer before any component receives any final paint coating. Application shall be in strict accordance with the paint manufacturer's instructions, including the number of coats and dry mil thickness.
Specify Finish Coat Mfr. & No. ______________________________
PREFINISH PAINTING COMPLY _____YES NO_____
The chassis area and component parts that will are inaccessible for "finish" painting when the completed unit is to be painted shall will be cleaned, primed and painted the specified gloss white color before final assembly.
STORAGE COMPARTMENT INTERIOR FINISH COMPLY _____YES NO_____
The interior of all storage compartments shall be unpainted/mill-finish.
NOTE: All stainless steel hinges, door handles and compartment latches are not to be painted.
PAINT FINISH WARRANTY COMPLY _____YES NO_____
The finish paint on the unit will be provided with a five (5) year paint finish guarantee for the following items: Peeling or delaminating of the topcoat or other layers of paint, cracking or checking, and the loss of gloss finish caused by defective materials or improper application. A copy of this warranty shall be submitted with the bid proposal.
EXTERIOR LETTERING / STRIPING COMPLY _____YES NO_____
Under the direction of the designated NDF representative, the contractor shall supply and install after final painting the full length of the chassis/body the 6" green reflective stripe and NDF exterior decal set and door shields on each unit manufactured. The striping package must conform to the NDF Fleet Standardization Plan and NFPA 1901 standards. Decals shall only be applied to the body after the chassis has been appropriately mounted to the body. The contractor shall also supply and install a 3" X 5" DIESEL FUEL adhesive backed decal on the vehicle fuel tank(s). This decal shall be weather and fuel proof.
CAB SEATING COMPARTMENT INSTRUCTION LABELS COMPLY _____YES NO_____
The contractor shall install and supply the following labels as required by State and Federal regulations. The labels shall be engraved plastic, red with white letters, black with white letters or white with red letters and fastened with rivets. Adhesive backed labels will be rejected. Mounting locations shall be discussed at the pre-construction conference.
• 1 each - The cab dash area shall have an apparatus dimension label installed. The label shall be highly visible, indicating the overall height, length, width and weight of the vehicle.
• 2 each - USE OF SEAT BELTS ARE MANADATORY AT ALL TIMES
• 1 each – DANGER - Personnel Must Be Seated And Seat Belts Must Be Fastened While Vehicle Is In Motion Or DEATH OR SERIOUS INJURY MAY RESULT - shall be provided in the apparatus cab interior. This label shall be located so that it is visible from all seating positions.
• 1 each - NO RIDING ON REAR OF APPARATUS - shall be installed on rear of the apparatus. The label shall be applied to the vehicle at the rear step area. The label shall warn personnel that riding in or on these areas, while the vehicle is in motion, are prohibited.
• 1 each -NO SMOKING
*******
Item Unit Extended MSRP
No. Qty. Description Price Price Price
3.1 1 WATER TENDER: 3,000 Gallon; ________ _________ ______
Diesel Powered Cab and Chassis; per each per each
In Accordance With Specifications Provided.
Specify Mfr. & No. _______________________________
Specify Warranty ________________________________
OPTIONAL EQUIPMENT:
Item Unit Extended MSRP
No. Qty. Description Price Price Price
3.2 2 4” SUCTION HOSE: _____ _____ _____
10’ Length Kocheck Maxi- Flex Suction Hose Per each Per each
(Small Lug) w/NH Threads.
3.3 2 2.5” SUCTION HOSE: _____ _____ _____
10’ Length Kocheck Maxi- Flex Suction Hose Per each Per each
(Small Lug) w/NH Threads.
3.4 2 1.5” SUCTION HOSE: _____ _____ _____
10’ Length Kocheck Maxi- Flex Suction Hose Per each Per each
(Small Lug) w/NH Threads.
3.5 1 4” SUCTION STRAINER: _____ _____ _____
Kocheck Suction Hose Strainer Per each Per each
w/NH Threaded Couplings
3.6 1 2.5” SUCTION STRAINER: _____ _____ _____
Kocheck Suction Hose Strainer Per each Per each
w/NH Threaded Couplings
3.7 1 1.5” SUCTION STRAINER: _____ _____ _____
Kocheck Suction Hose Strainer Per each Per each
w/NH Threaded Couplings
3.8 2 GATED WYES: _____ _____ _____
2.5" NH Female to 1.5" NH Male Per each Per each
w/Chrome Caps
3.9 5 WATER THIEF TEES: _____ _____ _____
1.5" NH x 1" NH Male Per each Per each
3.10 2 HYDRANT GATE VALVE: _____ _____ _____
2.5" NH Per each Per each
3.11 2 HYDRANT WRENCH: _____ _____ _____
Standard Adjustable Hydrant Wrench Per each Per each
3.12 1 CRAFTSMAN TOOL KIT: _____ _____ _____
Part # 34283 Per each Per each
3.13 1 FIRE FIGHTING PUMP 1.5”: _____ _____ _____
6HP Honda Engine, Let Goliath Per each Per each
Part # PFP 6HP HND-M-TWIN
3.14 2 DRIP TORCH: _____ _____ _____
w/Mounting Bracket, Cascade Per each Per each
#10000 & 10050
3.15 1 FENCE PLIER TOOL: _____ _____ _____
Standard Fence Cutting Pliers Per each Per each
3.16 1 RUBBER MALLET: _____ _____ _____
Nupla Rubber Mallet Per each Per each
3.17 1 WATER EXTINGUISHER: _____ _____ _____
Water Fire Extinguisher Per each Per each
3.18 1 FIRE EXTINGUISHER: _____ _____ _____
BC Dry Chemical Extinguisher Per each Per each
w/Mounting Bracket
3.18 1 SPANNER WRENCHES & MOUNT: _____ _____ _____
Akron #448 Spanner Wrench Mount Per each Per each
w/ Two (2) #10 Wrenches
3.19 1 AKRON ASSAULT #4802 1” NOZZLE: _____ _____ _____
w/Pistol Grip and Spinning Teeth 25 GPM Per each Per each
3.20 1 AKRON ASSAULT #4818 1.5” NOZZLE: _____ _____ _____
Break apart w/Pistol Grip Per each Per each
and Spinning Teeth 60-200 GPM
3.21 2 AKRON ASSAULT #4820 1.5” NOZZLE: _____ _____ _____
w/Pistol Grip and Spinning Teeth 60-200 GPM Per each Per each
3.22 2 F/M REDUCER _____ _____ _____
2.5” NHF x 1 ½” NHM reducer, lightweight alloy Per each Per each
3.23 2 F/M REDUCER: _____ _____ _____
1.5" NHF x 2.5" NHM reducer, lightweight alloy Per each Per each
3.24 2 ADAPTER: _____ _____ _____
2.5” NH x 4.5” double female adapter, Per each Per each
lightweight alloy
3.25 2 ADAPTER: _____ _____ _____
2.5” NH double male adapter, lightweight alloy Per each Per each
3.26 2 ADAPTER: _____ _____ _____
2.5” NH double female adapter, lightweight alloy Per each Per each
3.27 10 FIRE HOSE 3” x 50’: _____ _____ _____
2.5” couplings, synthetic hose, poly lined Per each Per each
w/lightweight alloy couplings, color tan
3.28 4 FIRE HOSE 3” x 25’: _____ _____ _____
2.5” couplings, synthetic hose, poly lined Per each Per each
w/lightweight alloy couplings, color tan
3.29 2 FIRE HOSE 1.5” x 20’: _____ _____ _____
synthetic hose, poly lined w/lightweight alloy Per each Per each
alloy couplings, color yellow
3.30 5 1“ WILDLAND FIRE HOSE 100’: _____ _____ _____
Single Jacket, color white Per each Per each
3.31 5 1.5“WILDLAND FIRE HOSE 100’: _____ _____ _____
Single Jacket, color white Per each Per each
“ALL OR NONE” TOTAL OPTIONAL EQUIPMENT PRICING: $____________________
Additional Requirements
(1) Bids MUST be submitted on this form to be considered.
(2) Bidders are especially cautioned to RECHECK BID PRICES FOR ERRORS prior to submitting bid as changes in bid prices after opening date and hour of bid due to an error WILL NOT BE PERMITTED OR ACCEPTED. Bidder shall be required to furnish equipment at price or prices bid on or be penalized by being removed from bidder’s list for a period of one year.
(3) The bidder certifies by signature on this bid that neither it nor its principals is presently debarred, suspended, proposed for debarment, declared ineligible, or voluntarily excluded from participation in any Federal department or agency sponsored program.
(4) Contractor in bidding on and in the performance of this solicitation shall be solely responsible for complying with all laws, including but not limited to, codes, statutes, regulations, and ordinances of the City, County, State, and Federal governments.
(5) Authorized service, repair and parts shall be required throughout the State of Nevada as it is unknown exact locations where unit(s) are to be deployed. State Name, Address and Phone Number of all service locations available. Service and repair locations may be determining factor in award of bid. __________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
State response time after initial call for service. ________ Hours.
(6) All vehicles bid on must meet the latest Federal Safety Regulations and be manufacturer’s current listed model.
(7) All vehicles bid on must meet the requirements of the Nevada Revised Statutes, Chapter 484 as applicable.
(8) All vehicles bid on must meet the requirements of the Nevada Revised Statutes, 482.318 et seq.
(9) All vehicles bid on must meet the requirements of the Nevada Revised Statutes, 482.135.
(10) All models shall be manufacturer's current listed model.
(11) As a condition of award, a vendor is required to deliver any vehicle(s) specified herein to any government entity using any award or contract that results from this solicitation through a licensed, Nevada vehicle dealer which will then be considered a joint submittal, or be a licensed Nevada vehicle dealer prior to the submission and opening date of the price agreement pursuant to Nevada Revised Statute 482. In the spaces below, please provide the Purchasing Division with the name, address, telephone number, facsimile number and license number of the dealer who will provide or perform the delivery of the completed unit(s).
Name: _________________________________________________________
Address: _______________________________________________________
Telephone Number: ____________________Fax: ______________________
Nevada Vehicle Dealer License Number: _____________________________
Signature of Nevada Vehicle Dealer: _________________________________
Failure to provide the requested information may be cause for rejection of your response.
(12) The section entitled "EXCEPTIONS TO SPECIFICATIONS" must be completed by all bidders. Failure to complete this section or failure to list exceptions he specifications will result in the bid being considered incomplete and unacceptable to the State of Nevada.
(13) If equipment is delivered minus any part, item or accessory issued as standard manufacturer's equipment, and/or as specified by the State, the successful bidder will be immediately notified. If the missing part, item or accessory cannot be provided and installed within 72 hours, the State reserves the right to buy the item or part from another source and bill the successful bidder for the cost including installation.
(14) All equipment, included in the base vehicle description or optional, must be factory installed when it is factory available. The Nevada State Purchasing Division, the purchasing local government or political subdivision whichever is applicable must receive prior notification whenever any local installation is to be performed. Any equipment included in the base vehicle description that is to be locally installed must be clearly listed. Any options that will be locally installed must be so noted.
(15) WARRANTY & RECALL SERVICE: All warranty and recall service shall be performed at a service facility located within the State of Nevada. Bids on equipment from manufacturers that do not have service facilities within the State or who cannot provide such service by an authorized representative within the State of Nevada will bear the cost of transportation to and from the place where work is to be done.
Warranty and Maintenance Requirements
a) Manufacturer's warranty shall be a minimum of 12 months on entire machine and 12 additional months on power train or longer if provided by O.E.M. at no cost to the State. Warranty will not begin until the unit has arrived at and been accepted by the at the final use location. NDF will provide the vendor with the effective date. .A copy of the manufacturer's and/or vendors standard warranty must be submitted with pricing.
b) Manufacturer shall provide a five-year limited body warranty against rust-thru from date of delivery. A two-year limited warranty against defects in materials and workmanship from date of delivery for items not in the 5-year policy
c) Vendor must provide details of any upgrade or delayed start warranty and any maintenance policy including costs to keep warranties in effect.
d) All warranty and recall service shall be performed at a factory authorized service facility located within the State of Nevada.
NOTE: Any information required for periodic service checks required to keep warranties in effect must be provided by successful bidder.
(16) Bidder is required to submit descriptive data or printed specifications describing COMPLETE UNIT bidding. Failure to comply with this request may be cause for non-acceptance of bid.
(17) BRAND NAMES: Unless otherwise stated “No Exceptions”, brand names mentioned in these specifications are for reference only and are intended for the purpose of assisting in describing the need, use, and quality of the item. The contractor will identify any alternate item(s) and it is the State’s prerogative to either accept or reject any alternative item(s).
(18) Bidders are especially cautioned to RECHECK BID PRICES FOR ERRORS prior to submitting bid as changes in bid prices after opening date and hour of bid due to an error WILL NOT BE PERMITTED OR ACCEPTED. Bidder shall be required to furnish equipment at price or prices bid on or be penalized by being removed from bidder's list for a period of one year.
(19) Vendor is required to provide Dealers Report of Sale (DRS) or Manufacturers Statement of Origin (MSO) with each equipment item at the time of delivery. Please specify the DRS/MSO be made out to:
Nevada Division of Forestry
2478 Fairview Drive
Carson City, NV 89701
(20) For purposes of addressing questions concerning this solicitation, the sole contact will be the Purchasing Division’s designee. Upon issuance of this solicitation, employees and representatives of the agencies identified herein will not answer questions or otherwise discuss the contents of this request with any prospective vendors or their representatives. Failure to observe this restriction may result in disqualification of any bid. This restriction does not preclude discussions between affected parties for the purpose of conducting business unrelated to this procurement.
4. PAYMENT
4.1 Prices offered in bids are an irrevocable offer for the term of the contract and any contract extensions unless otherwise specified in the Additional Requirements of this ITB.
4.2 The State generally pays within 30 days upon receipt of invoice and the using agency’s approval. Per the State’s policy and procedures, payments are not made prior to receipt of goods.
Vendor’s Payment Terms _____________________________
4.3 Prompt payment discount periods equal to (or greater than) 30 calendar days will receive consideration and bid pricing will be reduced (for evaluation purposes only) by the amount of that discount(s).
Vendor’s Prompt Payment Discount Offered ____________________
4.4 Vendor’s prices contained in this bid are subject to acceptance within _________calendar days.
4.5 The price quoted is for the specified delivery, and, unless otherwise specified in the Contract, is FOB destination (freight included) to the delivery address. Unless otherwise specified in the Contract, the price does not include applicable federal or State sales, use, excise, processing or any similar taxes, or duty charges, which shall be paid by the State, or in lieu thereof, the State shall provide the Vendor with a tax exemption certificate acceptable to the applicable taxing authority. Unless otherwise specified in the Contract, payment shall be made in accordance with Nevada law to the Vendor.
4.6 The State requests MSRP prices in effect at the time of bid submittal for internal statistical purposes.
4.7 Purchasing Card Acceptance
In an effort to streamline the purchasing and payment process, the State is encouraging agencies to use the state contracted purchasing card to facilitate small dollar purchases. While at the present time it is not mandatory that contractors accept credit card purchases; contractors are encouraged to consider this alternate payment process.
Purchasing (Credit) Cards accepted: Yes __________ No __________
Payment discount for transactions involving card use: ___________ % Discount.
4.8 Delivery
Delivery will be completed within _______ calendar days after receipt of purchase order.
5. BID SUBMITTAL INSTRUCTIONS
5.1 Bids must be received at the address referenced below per Section 5.5, ITB Timeline. Bids that do not arrive by bid opening time and date WILL NOT BE ACCEPTED. Vendors may submit their bid any time prior to the above stated deadline.
5.2 Bids may be submitted via mail, overnight delivery or facsimile.
5.2.1 Hard Copy Bid Submission: Must be submitted in a sealed package, the package must be clearly marked: Invitation to Bid No. 8474, Bid Opening Date: September 29, 2016.
Bid shall be submitted to:
State of Nevada, Purchasing Division
Heather Moon
515 E. Musser Street, Suite 300
Carson City, NV 89701
5.2.2 Electronic Bid Submittal: Faxed bids shall be sent to 775-684-0169 ONLY. Bids sent to any other fax number will NOT be accepted. Awarded vendor will be required to follow up with an original signature of the submitted bid. Bids sent by fax must be sent with a cover page, the package must be clearly marked: Invitation to Bid No. 8474, Bid Opening Date: September 29, 2016.
5.3 The State Purchasing Division will not be held responsible for bid packages mishandled as a result of not being properly prepared.
5.4 The Invitation to Bid (ITB) Question Submittal Form is located on the Solicitation Opportunities webpage at . Select the Solicitation Status, Questions dropdown and then scroll to the ITB number and select the “Question” link.
The deadline for submitting questions is as specified in Section 5.5 ITB Timeline.
All questions and/or comments will be addressed in writing. An email notification that the amendment has been posted to the Purchasing website will be issued on or about the date specified in Section 5.5, ITB Timeline.
5.5 ITB TIMELINE
The following represents the proposed timeline for this project. All times stated are Pacific Time (PT). These dates represent a tentative schedule of events. The State reserves the right to modify these dates at any time.
|Task |Date/Time |
|Deadline for submitting questions |09/13/2016 @ 12:00 PM |
|Answers posted to website |On or about 09/16/2016 |
|Deadline for submission and opening of bids |No later than 2:30 PM on 09/29/2016 |
|Evaluation period (approximate time frame) |09/29/2016 - 10/03/2016 |
|Selection of vendor |On or about 10/03/2016 |
5.6 This entire document and any amendments, if applicable, to this ITB must be returned as part of the vendor’s bid submission. Failure to comply with this requirement may be grounds for non-acceptance of the bid.
5.7 For purposes of addressing questions concerning this ITB the sole contact will be the Purchasing Division. Upon issuance of this ITB, employees and representatives of the agencies identified herein will not answer questions or otherwise discuss the contents of this ITB or any subsequent submitted bid responses with any prospective bidders or their representatives until issuance of formal NOA. Failure to observe this restriction may result in disqualification of any bid. This restriction does not preclude discussions between affected parties for the purpose of conducting business unrelated to this procurement.
5.8 Sealed bids will be publically opened and read at the date, time and location specified within the ITB. Assistance for handicapped, blind or hearing-impaired persons who wish to attend the ITB opening is available. If special arrangements are necessary, please notify the Purchasing Division designee as soon as possible and at least two days in advance of the opening.
6. BID SOLICITATION, EVALUATION AND AWARD PROCESS
6.1 This procurement is being conducted in accordance with NRS Chapter 333 and NAC Chapter 333.
6.2 Bids must conform to all terms, conditions and specifications in this ITB.
6.3 Contractor agrees to comply with conditions of the Federal Occupational Safety and Health Acts of 1970 (OSHA) as may be amended, and certifies that all items furnished and purchased under this order will conform to and comply with said standards and regulations. Contractor further agrees to indemnify and hold harmless purchaser from all damages assessed against purchaser as a result of Contractor’s failure to comply with the acts and standards thereunder and for the failure of the items furnished under this order to so comply.
6.4 Pursuant to NRS Chapter 613 in connection with the performance of work under this contract, the contractor agrees not to unlawfully discriminate against any employee or applicant for employment because of race, creed, color, national origin, sex, sexual orientation or age, including, without limitation, with regard to employment, upgrading, demotion or transfer, recruitment or recruitment advertising, layoff or termination, rates of pay or other forms of compensation, and selection for training, including, without limitation, apprenticeship.
The contractor further agrees to insert this provision in all subcontracts, hereunder, except subcontracts for standard commercial supplies or raw materials.
6.5 Every contract or order for goods must be awarded to the lowest responsible bidder. (NRS 333.340(1)) To determine the lowest responsible bidder, the Purchasing Division may consider:
• The location of the using agency to be supplied;
• The qualities of the articles to be supplied;
• The total cost of ownership of the articles to be supplied;
• The conformity of the articles to be supplied with the specifications;
• The purposes for which the articles to be supplied are required; and
• The dates of delivery of the articles to be supplied.
The Purchasing Division shall not be obligated to accept low bid, but will make an award in the best interest of the State after all factors have been evaluated. (NRS 333.300(2))
6.5.1 When the advertisement for bids includes a statement that bids for alternative articles will be considered, alternative articles will be considered in as much as they are determined to:
• Meet or exceed the specifications of the article listed in the original request for bids;
• The purchase of the alternative article results in a lower price; and
• The Chief deems the purchase of the alternative article to be in the best interests of the State.
6.6 Bids may be withdrawn by written or facsimile notice received prior to the ITB opening time. Withdrawals received after the ITB opening time will not be considered except as authorized by NRS 333.350(3).
6.7 The State reserves the right to alter, amend, or modify any provisions of this ITB, or to withdraw this ITB, at any time prior to the award of a contract pursuant hereto, if it is in the best interest of the State to do so.
6.8 Any unsuccessful bidder may file an appeal in strict compliance with NRS 333.370.
6.9 The Legislature, the Supreme Court, the Nevada Wing of the Civil Air Patrol (NRS 333.469), the Nevada System of Higher Education (NRS 333.470) and local governments (as defined in NRS 332.015) are intended third party beneficiaries of any contract resulting from this ITB and any local government may join or use any contract resulting from this ITB subject to all terms and conditions thereof pursuant to NRS 332.195. The State is not liable for the obligations of any local government which joins or uses any contract resulting from this ITB.
6.10 Vendors who enter into a contract with the State of Nevada and who sell tangible personal property in the State of Nevada are required to obtain a permit in accordance with NRS 372.125, and required to collect and pay the taxes imposed by law on the sale of tangible personal property in this State.
6.11 When applicable, submission of a bid must include any and all proposed terms and conditions, including, without limitation, written warranties, maintenance/service agreements, license agreements, lease purchase agreements and the bidder’s standard contract language. A review of these documents will be necessary to determine if a bid is in the best interest of the State.
7. TERMS AND CONDITIONS FOR PURCHASE OF GOODS
7.1 INCORPORATED DOCUMENTS: The Contract shall consist of this ITB, any amendments to this ITB if applicable, the vendor’s bid and all documentation contained therein, together with any subsequently issued purchase order(s) executed by a person with full power and authority to issue same on behalf of the State. A vendor’s bid shall not contradict or supersede any State specifications, terms or conditions without written evidence of mutual assent to such change appearing in the Contract.
7.2 NOTICE: Unless otherwise specified, termination shall not be effective until thirty (30) calendar days after a party has served written notice of default, or without cause upon the other party. All notices or other communications required or permitted to be given under this Contract shall be in writing and shall be deemed to have been duly given if delivered via email, personally in hand, by telephonic facsimile, regular mail, or mailed certified mail, return receipt requested, postage prepaid on the date posted, and addressed to the other party at the address specified above.
7.3 TERMINATION:
7.3.1 Termination Without Cause. Any discretionary or vested right of renewal notwithstanding, this Contract may be terminated upon written notice by mutual consent of both parties or unilaterally by either party without cause.
7.3.2 State Termination for Nonappropriation. The continuation of the Contract beyond the current biennium is subject to and contingent upon sufficient funds being appropriated, budgeted, and otherwise made available by the State Legislature and/or federal sources. The State may terminate the Contract, and the Vendor waives any and all claim(s) for damages, effective immediately upon receipt of written notice (or any date specified therein) if for any reason the Contracting Agency’s funding from State and/or federal sources is not appropriated or is withdrawn, limited, or impaired.
7.3.3 Cause Termination for Default or Breach. A default or breach may be declared with or without termination. The Contract may be terminated by either party upon written notice of default or breach to the other party as follows:
7.3.3.1 If the Vendor fails to provide or satisfactorily perform any of the conditions, work, deliverables, goods, or services called for by the Contract within the time requirements specified in the Contract or within any granted extension of those time requirements; or
7.3.3.2 If any state, county, city or federal license, authorization, waiver, permit, qualification or certification required by statute, ordinance, law, or regulation to be held by the Vendor to provide the goods or services required by the Contract is for any reason denied, revoked, debarred, excluded, terminated, suspended, lapsed, or not renewed; or
7.3.3.3 If the Vendor becomes insolvent, subject to receivership, or becomes voluntarily or involuntarily subject to the jurisdiction of the bankruptcy court; or
7.3.3.4 If the State materially breaches any material duty under the Contract and any such breach impairs the Vendor's ability to perform; or
7.3.3.5 If it is found by the State that any quid pro quo or gratuities in the form of money, services, entertainment, gifts, or otherwise were offered or given by the Vendor, or any agent or representative of the Vendor, to any officer or employee of the State of Nevada with a view toward securing a contract or securing favorable treatment with respect to awarding, extending, amending, or making any determination with respect to the performing of such contract; or
7.3.3.6 If it is found by the State that the Vendor has failed to disclose any material conflict of interest relative to the performance of the Contract.
7.3.4 Time to Correct. Termination upon a declared default or breach may be exercised only after service of formal written notice as specified in paragraph 6.2, and the subsequent failure of the defaulting party within fifteen (15) calendar days of receipt of that notice to provide evidence, satisfactory to the aggrieved party, showing that the declared default or breach has been corrected.
7.3.5 Winding Up Affairs Upon Termination. In the event of termination of the contract for any reason, the parties agree that the provisions of this paragraph survive termination:
7.3.5.1 The parties shall account for and properly present to each other all claims for fees and expenses and pay those that are undisputed and otherwise not subject to set off under the Contract. Neither party may withhold performance of winding up provisions solely based on nonpayment of fees or expenses accrued up to the time of termination;
7.3.5.2 The Vendor shall satisfactorily complete work in progress at the agreed rate (or a pro rata basis if necessary) if so requested by the Contracting Agency.
7.4 REPRESENTATIONS AND WARRANTIES: The Vendor represents and warrants to the State:
7.4.1 Bid Representations: All statements made by the Vendor on any application, bid, proposal, offer, financial statement, or other document used by the Vendor to induce the State to enter into the Contract are true, correct, complete, and omit no information which would render them misleading.
7.4.2 Use of Broker: The Vendor agrees to indemnify the State from any damage, liability, or expense that it may suffer as a result of any claim of a broker or other finder with whom it is determined that the Vendor has dealt in connection with the transactions contemplated under the contract.
7.4.3 Express Warranties: For the period specified in the NOA, Vendor warrants and represents each of the following with respect to any goods provided under the contract:
7.4.3.1 Fitness for Particular Purpose: The goods shall be fit and sufficient for the particular purpose set forth in the Contract.
7.4.3.2 Fitness for Ordinary Use: The goods shall be fit for the purpose for which goods of a like nature are ordinarily intended, it being understood that the purpose for the goods covered by the Contract are ordinarily intended for use in general government administration and operations.
7.4.3.3 Merchantable, Good Quality, No Defects: The goods shall be merchantable, of good quality, and free from defects, whether patent or latent, in material and workmanship.
7.4.3.4 Conformity: The goods shall conform to the standards, specifications and descriptions set forth in the Contract. If the Vendor has supplied a sample to the State, the goods delivered shall conform in all respects to the sample and shall be identified by the word "sample" and Vendor's name.
7.4.3.5 Uniformity: The goods shall be without variation, and shall be of uniform kind, quality, and quantity within each unit and among all units.
7.4.3.6 Packaging and Labels: The goods shall be contained, packaged, and labeled so as to satisfy all legal and commercial requirements applicable to use by a government agency, including without limitation, Occupational Safety and Health Administration material safety data sheets and shall conform to all statements made on the label.
7.4.3.7 Full Warranty: The foregoing warranties are "full" warranties within the meaning of the Magnuson-Moss Warranty -- Federal Trade Commission Improvement Act, 15 U.S.C. 2301 et seq., and implementing regulations 16 C.F.R. pts. 700-703, if applicable to this transaction.
7.4.3.8 Title: The Vendor has exclusive title to the goods and shall pass title to the State free and clear of all liens, encumbrances, and security interests.
7.4.3.9 Infringement; Indemnity: The Vendor warrants the purchase or use of the goods shall not infringe upon any United States or foreign patent, and the Vendor shall indemnify the State against all judgments, decrees, costs, and expenses resulting from any alleged infringement and shall defend, upon written request of the State, at its own expense, any action which may be brought against the State, its vendees, lessees, licensees, or assignees, under any claim of patent infringement in the purchase or use of the Vendor's goods. If the State is enjoined from using such goods, the Vendor shall re-purchase such goods from the State at the original purchase price. The State shall notify the Vendor promptly in writing of any such suit. If the State compromises or settles any such suit without the written consent of the Vendor, the Vendor shall be released from the obligations of this paragraph and from any liability to the State under any statute or other rule of law.
7.4.3.10 Usage of Trade; Course of Dealings; Implied Warranties: The Vendor shall be bound by any implied warranty that, at the time of execution of the Contract, prevails in the trade of government in the marketing area in and about the State of Nevada. The Vendor shall also be bound by any other implied warranty arising through course of dealings between the Vendor and the State from and after the execution of the Contract. The Vendor shall also be bound by all warranties set forth in Nevada's Uniform Commercial Code (NRS
Chapter 104) in effect on the date of issuance of the NOA.
7.4.3.11 Warranties Cumulative: It is understood that warranties created by the Contract, whether express or implied, as well as all warranties arising by operation of law that affect the rights of the parties, are cumulative and should be construed in a manner consistent with one another.
7.4.3.12 Priority of Warranties: If it is held by a court of competent jurisdiction that there is an irreconcilable conflict between or among any of the warranties set forth in the Contract and any warranties implied by law, the parties agree that the specifications contained in the Contract shall be deemed technical and mere language of description.
7.4.3.13 Beneficiaries of Warranties: Benefit of any warranty made in the Contract shall be in favor of the State, any of its political subdivisions or agencies, employee or licensee thereof who uses the goods, and the benefit of any warranty shall apply to both personal injury and property damage.
7.5 DELIVERY, INSPECTION, ACCEPTANCE, TITLE, RISK OF LOSS: The Vendor agrees to deliver the goods as indicated in the Contract, and upon acceptance by the State, title to the goods shall pass to the State. The State shall have the right to inspect the goods on arrival and within a commercially reasonable time. The State must give notice to the Vendor of any claim or damages on account of condition, quality, or grade of the goods, and must specify the basis of the claim in detail. Acceptance of the goods described in the Contract is not a waiver of UCC revocation of acceptance rights or of any right of action that the State may have for breach of warranty or any other cause. Unless otherwise stated above, risk of loss from any casualty, regardless of the cause, shall be on the Vendor until the goods have been accepted and title has passed to the State. If provided by the Vendor, the State agrees to follow reasonable instructions regarding return of the goods.
7.6 NO ARRIVAL, NO SALE: The Contract is subject to provisions of no arrival, no sale terms, but proof of shipment shall be given by the Vendor; each shipment to constitute a separate delivery. A variation of ten (10) days in time of shipment or delivery from that specified in the Contract does not constitute a ground for rejection. The State may treat any deterioration of the goods as entitling the State to the rights resulting from a casualty to the identified goods without regard to whether there has been sufficient deterioration so that the goods no longer conform to the Contract.
7.7 BREACH, REMEDIES: Failure of either party to perform any obligation of the Contract shall be deemed a breach. In the event of a breach, the party asserting breach may, in addition to any remedies or rights afforded by Nevada law, cancel the Contract with respect to any executory obligations. All rights and remedies are cumulative with one another and with those provided by law, and exercise of one remedy or right is not a waiver of the right to pursue any other right or remedy afforded. Penalties provided under Nevada law shall be limited to those in effect on the effective date of the Contract. See NRS 333.365. Either party, as a prevailing party to any arbitration or other action regarding the enforcement of the Contract, is entitled to reasonable attorney’s fees and costs. It is specifically agreed that reasonable attorneys' fees shall include without limitation One hundred twenty-five dollars ($125) per hour for State-employed attorneys. The State may set off consideration against any unpaid obligation of the Vendor to any State agency.
7.8 LIMITED LIABILITY: The State will not waive and intends to assert available NRS Chapter 41 liability limitations in all cases. Contract liability of both parties shall not be subject to punitive damages.
7.9 WAIVER OF BREACH: A failure to assert any right or remedy available to a party under the Contract, or a waiver of the rights or remedies available to a party by a course of dealing or otherwise shall not be deemed to be a waiver of any other right or remedy under the Contract, unless such waiver is contained in a writing signed by the waiving party.
7.10 SEVERABILITY: If any provision contained in the Contract is held to be unenforceable by a court of law or equity, the Contract shall be construed as if such provision did not exist and the non-enforceability of such provision shall not be held to render any other provision or provisions of the Contract unenforceable.
7.11 ASSIGNMENT/DELEGATION: To the extent that any assignment of any right under the Contract changes the duty of either party, increases the burden or risk involved, impairs the chances of obtaining the performance of the Contract, attempts to operate as a novation, or includes a waiver or abrogation of any defense to payment by State, such offending portion of the assignment shall be void, and shall be a breach of the Contract. No duties of either party may be delegated without written consent by the other party, and any such consent does not in any way affect the liability of the delegating party, unless the writing so states.
7.12 FORCE MAJEURE: Neither party shall be deemed to be in violation of this Contract if it is prevented from performing any of its obligations hereunder due to strikes, failure of public transportation, civil or military authority, act of public enemy, accidents, fires, explosions, or acts of God, including, without limitation, earthquakes, floods, winds, or storms. In such an event the intervening cause must not be through the fault of the party asserting such an excuse, and the excused party is obligated to promptly perform in accordance with the terms of the Contract after the intervening cause ceases.
7.13 GOVERNING LAW; JURISDICTION: This Contract and the rights and obligations of the parties hereto shall be governed by, and construed according to, the laws of the State of Nevada, including, without limitation, Nevada's UCC (NRS Chapter 104) in effect on the date of the NOA. The parties consent to the jurisdiction and venue of the First Judicial District Court, Carson City, Nevada for enforcement of the Contract.
7.14 ENTIRE AGREEMENT; CONFLICT WITH OTHER DOCUMENTS: The Contract (including all incorporated attachments) is intended by the parties as the final expression of their agreement and is the complete and exclusive statement of the terms hereof. All prior agreements are superseded and excluded. Prices, quantities, dates, and places of deliveries and means of transportation may be fixed by attachments to the Contract. Except as previously stated, if any term in any incorporated attachment or in any Vendor's invoice contradicts or negates a term in the Contract, the Contract shall control. All amendments must be in writing and signed by the parties.
7.15 In accordance with NRS 333.4611, the State of Nevada, Purchasing Division shall require the purchase of new appliances, equipment, lighting and other devices that use electricity, natural gas, propane or oil, have received the Energy Star label pursuant to the program established pursuant to 42 U.S.C. 6294a or its successor, or meet the requirements established pursuant to 48 C.F.R. 23.203. These standards do not apply insofar as: (a) No items in a given class have been evaluated to determine whether they are eligible to receive the Energy Star label or have been designated by the Federal Government to meet the requirements established pursuant to 48 C.F.R. 23.302 or (b) The purchase of these items that have received the Energy Star label would not be cost-effective in an individual instance, comparing the cost of the items to the cost of the amount of energy that will be saved over the useful life of the item.
7.16 TERM: In accordance with NRS 333.280, the Purchasing Division may enter into a contract for the furnishing of goods for not more than two (2) years. The original terms of a contract may be extended annually thereafter if the conditions for extension are specified in this solicitation, and the Purchasing Division determines that an extension is in the best interest of the State.
7.17 INSURANCE: Automobile Liability, as stated below, is required only if the commodity is being delivered to the State by the vendor. If the commodity is being shipped by common carrier, automobile liability will not be required. Vendor shall furnish the State with certificates of insurance (ACORD form or equivalent approved by the State) as required. The certificates for each insurance policy are to be signed by a person authorized by that insurer to bind coverage on its behalf.
Automobile Liability
Bodily Injury and Property Damage for any owned, hired, and non-owned vehicles used in the performance of this Contract.
Combined Single Limit (CSL) $1,000,000
ATTACHMENT A
VENDOR AUTHORIZATION AND COMPLIANCE CERTIFICATION
The Vendor is duly organized, validly existing, and in good standing under the appropriate laws with full power and authority to conduct the business that it presently conducts in the State of Nevada. The Vendor has the legal power and right to enter into and perform the Contract. Consummation of the transactions contemplated by the Contract will not violate any provision of law, or any of the Vendors governing documents (articles of incorporation, partnership Contract, etc). Execution of the Contract and all documents provided for in the Contract by the Vendor and its delivery to the State have been duly authorized by the board of directors or managing agents of the Vendor and no further action is necessary on the Vendor's part to make the Contract valid and binding on the Vendor in accordance with its terms. The Vendor has obtained all licenses and permits to perform all of its requirements under the Contract, and is current on all tax obligations to the State of Nevada or any other governmental entity in Nevada.
Submission of a bid shall constitute an agreement to all terms and conditions specified in this ITB, including, without limitation, the Terms and Conditions for Purchase of Goods. Exceptions will be taken into consideration as part of the evaluation process.
I have read, understand and agree to comply with the specifications, terms and conditions specified in this ITB. Checking “YES” indicates compliance, while checking “NO” indicates non-compliance and must be detailed below. In order for any exceptions to be considered they MUST be documented.
YES _______ I agree. NO _______ I do not agree, Exceptions below:
SIGNATURE _________________________________________ ___________________
Vendor Date
PRINT NAME _________________________________________
Vendor
EXCEPTION SUMMARY
Attached additional sheets if necessary
|BID SECTION NUMBER |BID PAGE NUMBER |EXCEPTION |
| | |(PROVIDE A DETAILED EXPLANATION) |
| | | |
| | | |
| | | |
| | | |
| | | |
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related searches
- title loans online without inspection of car
- purchased vehicle out of state
- material and non material elements of culture
- percentage of americans with 401k or stock
- symptoms of female heart attack or stroke
- spiritual meaning of 333 joanne
- meaning of 333 spiritual path
- spiritual meaning of 333 bible
- meaning of number 333 biblical
- cost of goods purchased formula
- cost of merchandise purchased formula
- ltd commodities catalog