AR-716-E16
ACCESS & INDUSTRIAL CONTROL
AR-716-E16
V220912
Contents
1 Product
2 Panel Mounting Base (AR-716-E16-X)
3 Metal Box (AR-716-E16-M)
Option
Option
AR-701B-X Fit 35mm DIN Rail or Mount directly
Specification
CPU
32bit / ARM32 72MHz / Flash 512KB Temperature
20 70
Memory
2048KB (2MB)
Digital Input
2 Door Open Button/ 2 Door Sensor/ 1 Fire-alarm
Power Supply 9 ~ 24VDC
Relpy Output 2 Door Relay / 1 Alarm Relay
Power Consumption < 3W
Door Relay Time Toggle, 0.1~600 Sec.
Interface /
RS-485 : 9600 bps (N, 8, 1) Alarm Relay Time Toggle, 0.1~600 Sec.
Baud Rate
Ethernet : 10/100M Base T
User Capacity 16,000 (Default value) / 32,000 / 65,000
External Readers 2 RS-485 + 2 WG
Event log
32,000
Aux. WG Port Anti-pass-back Lift Control Door Group Time Zone Real-time Clock DIP_SW
WG 26 / WG 34 16 Doors Yes 255 63 (stand-alone /networking) YES 8 (Node ID: 1~254)
Connector Table
POWER BUSY (REV)
LED
ON 1 2 3 45 6 7 8
CN15 CN13/CN14/CN12 CN10/CN11/CN9
21 7 65 4 3 2 1 7 65 4 3 2 1
GND Fire WG PORT0 Dip-switch ALM
WG PORT1
Reset (Hold till BUSY LED is blinking)
LED
Host
21
Host TX Host RX CH1 TX CH1 RX CH2 TX CH2 RX
LED
CH1
21
LED
CH2
21
TCP/IP Module
Relay LED
K1 K2 K3 Door Door ALM
N.O.
N.O.
N.O.
Door/Alarm Relay Ouput Power 65 43 21 43 21
CN1 CN2 CN3 CN18 CN4/CN5/CN6 CN7/CN8
Connector CN1 Host RS-485
Code
Pin Description
LA+
1 Host RS-485(A+)
LB-
2 Host RS-485(B-)
Connector: CN2 CH1 Slave RS-485
Code
Pin Description
LA+
1 RS-485(A+)
LB-
2 RS-485(B-)
Connector CN4/CN5/CN6 WG Door / Alarm Relay
Code
Pin Description
Alarm Relay
1 K3-N.O./N.C.
Output
2 COM
Door 1 Relay
3 K2-N.O./N.C.
Output (WG1)
4 COM
Door 0 Relay
5 K1-N.O./N.C.
Output (WG0)
6 COM
Connector CN3 CH2 Slave RS-485
Code
Pin Description
LA+
1 RS-485(A+)
LB-
2 RS-485(B-)
Connector CN15 Fire-alarm Input
Code
Pin Description
Fire-ALM
1 Fire-alarm Input
GND
2 DC Power 0V Output
Connector CN7/CN8 Power Supply
Code
Pin Description
GND
1 0V Input
VIN (716-E16) 2 12VDC Input
GND
3 0V Output
VOUT(Slave units) 4 12VDC Output
Connector CN9/CN10/CN11 WG Port 1
Code
Pin Description
WG0
1 Wiegand DAT: 0 Input
WG1
2 Wiegand DAT: 1 Input
BZ
3 Beeper Output
LEDG
4 LED Green Output
LEDR
5 LED Red Output
SEN (N.C.)
6 Door Status Input
EGR: PB (N.O.) 7 Exit Button Input
Connector CN12/CN13/CN14 WG Port 0
Code
Pin
WG0
1
WG1
2
BZ
3
LEDG
4
LEDR
5
SEN (N.C.)
6
EGR: PB (N.O.) 7
Description Wiegand DAT:0 Input Wiegand DAT:1 Input Beeper Output LED Green Output LED Red Output Door Status Input Exit Button Input
Connector CN18 Host TCP/IP
Code
Pin Description
TCP/IP Socket 1 CAT5
Installation
231 mm 117 mm
110 mm 80 mm
Metal Box
Plastic Mounting Base
175 mm 90 mm
180 mm 93 mm
- 1 -
16 Doors IP Control Panel
Hardware Architecture
WG Port 0
WG Port 1
V220912
Fire
Door Sensor Push Button
Wiegand Reader
Door Sensor Push Button
Wiegand Reader
CN15
CN12~14
CN9~11
SOYAL
or
or
Converter Converter AR-727-CM AR-321-CM
CN1 CN2 CN3
CN18 CN4 CN5 CN6 CN7 CN8
Door Lock for WG Port 0
Door Lock for WG Port 1
CH1 support two wiring method:
1 CH1 supports WG1 & WG2 & 6 doors (WG1 & WG2 & Subnode 3~8)
2 CH1 supports 8 doors (Subnode 1~8)
CH1
CH2
or
or
Magnetic Lock or Electric Bolt
Magnetic Lock or Electric Bolt
CH2 supports 8 doors (Subnode 9~16)
WG
Node ID 003 Node ID 004 Node ID 005
Reader
WG
Node ID 008
Reader
Node ID 009 Node ID 010 Node ID 011 Node ID 012 Node ID 013 Node ID 014 Node ID 015 Node ID 016
AR-0600M-270 Magnetic Lock
AR-0600M-270 Magnetic Lock
AR-0600M-270 Magnetic Lock
AR-101PBI-L Push Button
AR-101PBI-L Push Button
AR-101PBI-L Push Button
Controller
Each reader under CH/CH2 is able to connect input and output devices according to the requirements (such as: exit button/door sensor /electric magnetic lock/electric bolt lock/electric strike )
AR-1207 Electric Bolt
AR-1207
AR-1207
WG Reader
WG
WG
Controller
Controller
Controller
- 2 -
ACCESS & INDUSTRIAL CONTROL
AR-716-E16
Wiring Diagram
Fire
COM N.O.
WG Port 0
SOYAL SOYAL Door Sensor
SOYAL PSusOhYABLutton DNo.oOr. Sensor
WG Port 1
1 23 456 789
*0#
Wiegand Reader Push Button
1 23 456 789
*0#
Wiegand Reader
N.C.
N.O.
ON
1 2 3 45 6 7 8
Node ID is set by DIP_Switch, Node ID: 001~254
~
Value DIP SW Node 01 Node 02 Node 03
1 2 4 8 16 32 64 128 12345678 ON Off Off Off Off Off Off Off Off ON Off Off Off Off Off Off ON ON Off Off Off Off Off Off
Node 253 ON Off ON ON ON ON ON ON Node 254 Off ON ON ON ON ON ON ON
LEDG BZ
EGR: PB (N.O.) CN10 SEN (N.C.)
LEDR
WG1 WG0
LEDG BZ
EGR: PB (N.O.) CN13 SEN (N.C.)
LEDR
GND CN15 Fire-ALM
CN11
CN12
CN14
To PC
Port 0
Port 1
BZ RLED GGLLEEDD WG 1 WG 0
0V 12V BZ RLED GGLLEEDD WG 1 WG 0 0V 12V
+ ?
ON 1 2 3 45 6 7 8
+ ?
CN9
WG1 WG0
V220912
POWER
12~24V
If the wire length of Controller and Reader is more than 100 meters, it is recommended NOT to use the "Wiegand Power." Check connection mode within the dashed box: Controller and Reader must use the "common-COM-point."
POWER 12~24V
(REV) BUSY Reset POWER
K3 Alarm
K1: WG PORT0 N.O. Door
K2: WG PORT1 N.O. Door
TCP/IP Module (Optional)
HUB
USB
CH1 CN2 CH1 TX CH1 RX
CH2 CN3 CH2 TX CH2 RX
Host TX Host RX
TCP/IP RJ45
CN18
Host CN1
or
or
Converter AR-727-CM
Converter AR-321-CM
+
+
+
Ethernet
N.O.(Jumper)
COM CN4 Door 0
COM Door 1
CN5
COM Alarm
CN6
VOUT(Slave units)
GND CN7
N.O.
VIN (716-E16) GND CN8
Door Lock for WG Port 1
Electric Bolt Door Lock for WG Port 0 or
Magnetic Lock
Electric Bolt
or +
+
Magnetic Lock
+
......
1 23 456 789
*0#
Node ID 008 Controller
Node ID 002 Node ID 001 Controller Controller
RS-485 CH1/CH2 Port Connect to Electric Lock
?
POWER 12~24V
+
1 23 456 789
*0#
......
Node ID 009 Node ID 010 Node ID 011 Node ID 012 Controller Controller Controller Controller
Node ID 016 Controller
Lock Power 12~24V
?
+
N.O. N.C. COM SEN PB ALM 12V 0V
1 23 456 789
*0#
Controller
N.C.
SOYAL SOYAL
Door Sensor
N.O.
+
+
Push Button Electric Strike Electric Bolt or Magnetic Lock
- 3 -
16 Doors IP Control Panel
IP Setting
Open your Web Browser and input factory default IP
address:
If the IP address of AR-716-E16 has been changed, we must enter the new IP address.
Page menu
Current Status
Monitor the on-line computer
Network Setting
IP Setting
User Password
Change the Log-in information
Current State Online Status is able to be monitored showing which computer is linking on Ethernet Module
Current IP address of the AR-716-E16
Log-in User Password
When you choose the "Networking Setting" or "User Password," Log-in window will pop out and please input user name and password. At the Factory Default Status -
User name: SuperAdm Password: 721568
Networking Setting
You will see initial IP Address 192.168.1.127 and make sure MAC Address is identical to the sticker on Ethernet Module device. Please alter the IP address as you want, and then click "Update" button. After updating the IP, please re-connect the Web Browser with the new IP address.
User Password Change the log-in password to lock the IP setting of Ethernet Module. The password can be made up of 10 characters at most, and it can be either A~Z or 0~9.
- 4 -
V220912
ACCESS & INDUSTRIAL CONTROL
AR-716-E16
V220912
Initial Setup:
Software: Connection
1. Open the "701 Server" Software There are two ways to open the Communication Port setting window:
and Communication Port Setting
a
c e
a. According to the computer Detection results to select the port (Use the RS-485)
b b. Select [TCP/IP Oonly] (Use the Ethernet) c. Select the option: Polling Message From Controller
d d. Polling Interval: 200ms - meaning the PC polls the controller every 200ms once it accesses the message from the controller
e. Click YES
2. After COM Port setting, there are two ways to open the Node Number for Polling window:
and
Node Number for Polling
f. Select node ID (for example:001) and access controller
" 327E/3xxE/7xxE/8xxE/716Ev5"
g. If use the Ethernet mode, please check the "IP"; if use the RS-485
mode, there's no need to check
f
g
h
h. If use the Ethernet mode, input IP in "IP Address" column
(Default value: 192.168.1.127)
i i. Input 1621 in "Port" column(Default value: 1621; the Port number
is predetermined by SOYAL for connection to the network)
j. Select LAN BASE
k. Click YES
3. Open Controller On/Off Line window to check the device connection status:
Well: controller successfully connected to PC. Not connected well: the following checks are required.
Software: Parameters Settting: Door Number and Users Edit
1. After the 701Server Software connection, go click 82xEv5 Parameters Setting
to set up 716-E16's door number
a. Roll and select the Targe Node ID of 716-E16 (The same as the dip-switch) b. Click "Read" to read back the parameter of 716-E16 c. Click "716-E16" button to set up Door Number d. Input the new Door Number of Slave Reader, which door number must be unique and non-repetitive
- 5 -
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- registered enrolled voters statewide
- calix gigacenter skybest
- department of veterans affairs equal employment
- torque tension reference guide fastenal
- anyconnect client to asa with use of dhcp for cisco
- panasonic security viewer for smartphone
- 844e gigacenter quick start guide
- i 485 inventory as of january 2019
- consumer price index minneapolis st paul bloomington
- south dakota mortality report final 2020 provisional