Configurable NAT Router User Manual - Rockwell Automation
User Manual
Configurable NAT Router
Catalog Number 1783-NATR
Important User Information
Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards.
Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice.
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.
The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams.
No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual.
Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited.
Throughout this manual, when necessary, we use notes to make you aware of safety considerations.
WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss.
ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence.
IMPORTANT Identifies information that is critical for successful application and understanding of the product.
Labels may also be on or inside the equipment to provide specific precautions.
SHOCK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be present.
BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous temperatures.
ARC FLASH HAZARD: Labels may be on or inside the equipment, for example, a motor control center, to alert people to potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE). Follow ALL Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE).
Allen-Bradley, Rockwell Software, Rockwell Automation, RSLinx Classic, Stratix 5700, Stratix 5900, Studio 5000, and Studio 5000 Logix Designer are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.
Preface
Network Implementation
The 1783-NATR is a network device with Embedded Switch Technology capable of doing Network Address Translation (NAT) for applications using Device Level Ring (DLR) or linear topologies. The 1783-NATR device can be used to connect a small private network (for example, a machine network) to a larger plant-wide network without changing IP addresses on the private network.
The 1783-NATR device serves as a default gateway for the private network. It translates private IP addresses to unique public IP addresses (1:1 NAT). If a device on the private network must be accessible from the public network, a translation is created on the 1783-NATR device.
Figure 1 shows an example network implementation of the 1783-NATR device. In this example, two small machines with private networks are integrated into an overall plant network for remote access and monitoring purposes.
Figure 1 - Network Implementation Example with 1783-NATR Device
FORCE
EtherNet/IPTM
EtherNet/IPTM
Cisco 3750X
1:1 NAT Mapping
Private
192.168.1.2 192.168.1.3 192.168.1.4 192.168.1.5 192.168.1.6 192.168.1.7 192.168.1.8
Public
10.10.10.2 10.10.10.3 10.10.10.4 10.10.10.5 10.10.10.6 10.10.10.7 10.10.10.8
Public IP 10.10.10.x
Stratix 5700
Com IN2 Ref IN1
Public IP 10.10.11.x
1:1 NAT Mapping
Private
192.168.1.2 192.168.1.3 192.168.1.4 192.168.1.5 192.168.1.6 192.168.1.7 192.168.1.8
Public
10.10.11.2 10.10.11.3 10.10.11.4 10.10.11.5 10.10.11.6 10.10.11.7 10.10.11.8
192.168.1.7
1783-NATR 192.168.1.2
115 VAC
RELAY
192.168.1.8
MACHINE 1 Private IP Address: 192.168.1.X
192.168.1.6
192.168.1.3
Module Status Network Activity Network Status Point Bus Status 1734-AENT System Power Field Power
192.168.1.4
Module Status Network Activity Network Status Point Bus Status 1734-AENT System Power Field Power
192.168.1.5
AC/DC OUT AC/DC OUT
1783-NATR 192.168.1.2
192.168.1.7
115 VAC
RELAY
192.168.1.8
MACHINE 2 Private IP Address: 192.168.1.X
192.168.1.6
192.168.1.3
Module Status Network Activity Network Status Point Bus Status 1734-AENT System Power Field Power
192.168.1.4
Module Status Network Activity Network Status Point Bus Status 1734-AENT System Power Field Power
192.168.1.5
Rockwell Automation Publication 1783-UM008A-EN-P - February 2015
3
Preface
Line Controller
EtherNet/IPTM
EtherNet/IPTM
FORCE
Figure 2 shows an example network implementation of the 1783-NATR device with a Stratix 8300 switch.
Figure 2 - Network Implementation Example with 1783-NATR Device and Stratix 8300
Stratix 8300
1:1 NAT Mapping
Private
192.168.1.2 192.168.1.3 192.168.1.4 192.168.1.5 192.168.1.6
Public
10.10.10.2 10.10.10.3 10.10.10.4 10.10.10.5 10.10.10.6
Public IP 10.10.10.x
1783-NATR
Private IP 192.168.1.x
Public IP 10.10.11.x
1783-NATR
1:1 NAT Mapping
Private
192.168.1.2 192.168.1.3 192.168.1.4 192.168.1.5 192.168.1.6
Public
10.10.11.2 10.10.11.3 10.10.11.4 10.10.11.5 10.10.11.6
Private IP 192.168.1.x
192.168.1.3
IN
OUT
00:00:BC:66:0F:C7
DANGER
24VDC SOURCE
24VDC SINK\ SOURCE
0 1 2 3 45 6 7 8 9 10 11 12 13 14 15
0 1 2 3 45 6 7 8 9 10 11 12 13 14 15
DC OUTPUT
DC INPUT
HIGH SPEED COUNTER
A0 B0 Z0 A1 B1 Z1
0 2 FUSE 1 3 OK
00 08 01 09 02 10 03 11 04 12 05 13 06 14 07 15 COM COM 01 NC NC +V +V
00 08 01 09 02 10 03 11 04 12 05 13 06 14 07 15 CO0M CO1M
A0+ AoB0+ B0-
Z0+ Z0A1+ A1B1+ B1-
Z1+ Z1-
+V -V OUT OUT 02 O1UT O3UT
COM COM
OVUT OVUT 0+ 0+
O0VVU+T
OVUT 0V+
O0U+T O0U+T
O0VU+T O0VU+T COM O0VU+T
COM O0VU+T
O0VU+T O0VU+T O0VU+T O0VU+T OUIT OUIT 0+ 0+
COM COM
192.168.1.2
Mod Net
5500S2
2 1
IN1
U
COM
IN2
V
SHLD W
D+
D-
-
+
MBRK
192.168.1.4
MACHINE 1 For this example, all machine nodes must have their gateway IP set to 192.168.1.1
192.168.1.6
Module Status Network Activity Network Status Point Bus Status 1734-AENT System Power Field Power
192.168.1.5
192.168.1.6
192.168.1.3
IN
OUT
00:00:BC:66:0F:C7
DANGER
24VDC SOURCE
24VDC SINK\ SOURCE
0 1 2 3 45 6 7 8 9 10 11 12 13 14 15
0 1 2 3 45 6 7 8 9 10 11 12 13 14 15
DC OUTPUT
DC INPUT
HIGH SPEED COUNTER
A0 B0 Z0 A1 B1 Z1
0 2 FUSE 1 3 OK
00 08 01 09 02 10 03 11 04 12 05 13 06 14 07 15 COM COM 01 NC NC +V +V
00 08 01 09 02 10 03 11 04 12 05 13 06 14 07 15 CO0M CO1M
A0+ AoB0+ B0-
Z0+ Z0A1+ A1B1+ B1-
Z1+ Z1-
+V -V OUT OUT 02 O1UT O3UT
COM COM
OVUT OVUT 0+ 0+
O0VVU+T
OVUT 0V+
O0U+T O0U+T
O0VU+T O0VU+T COM O0VU+T
COM O0VU+T
O0VU+T O0VU+T O0VU+T O0VU+T OUIT OUIT 0+ 0+
COM COM
192.168.1.2
Mod Net
5500S2
2 1
IN1
U
COM
IN2
V
SHLD W
D+
D-
-
+
MBRK
192.168.1.4
MACHINE 2 For this example, all machine nodes must have their gateway IP set to 192.168.1.1
Module Status Network Activity Network Status Point Bus Status 1734-AENT System Power Field Power
192.168.1.5
Because there are Public and Private ports on the 1783-NATR device, the ports are used for different purposes.
Public Port
The Public port is used to connect the device to the Public (Outside) network. The public network can be a plant-wide network with unique IP addressing scheme. The MAC address of the Public port differs from the MAC address of the Private ports. The IP address of the Public port also differs from the IP address of the Private ports. The Public port is in standard Ethernet configuration in the Star topology.
4
Rockwell Automation Publication 1783-UM008A-EN-P - February 2015
Access Release Notes
Preface
Private Ports
The Private ports are used to connect the device to the Private (Inside) network. The private network can be a small network for a machine or process area where IP addresses can be reused throughout the plant. The Private ports share MAC addresses, which differ from the MAC address of the Public port. The Private ports share IP addresses, which differ from the IP address of the Public port. The Private ports can be used in the Linear or Ring topology. In Ring topology, the ports comply with the ODVA DLR specification. In Linear topology, the ports operate as standard Ethernet in daisy-chain or star topology.
Product release notes are available online within the Product Compatibility and Download Center.
1. From the Quick Links list on , choose Product Compatibility and Download Center.
2. From the Compatibility Scenarios tab or the Get Downloads tab, search for and choose your product.
3. Click the download icon
to access product release notes.
Rockwell Automation Publication 1783-UM008A-EN-P - February 2015
5
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- connections and ip address xerox
- xplornet hub 2
- quick start guide engenius tech
- 192 168 1 100 for your t3 troubleshooting tp link
- lab building a switch and router network
- zigbee emberznet sdk 7 1 1 0 ga silicon labs
- how to set wi fi function for hikvision wi fi camera
- configuring a tplink router actcorp
- file sharing application guide tp link
- jlv 3 1 0 0 0 user guide veterans affairs
Related searches
- excel user manual pdf
- excel 2016 user manual pdf
- excel user manual free download
- how to find router user name
- microsoft project user manual pdf
- sap user manual pdf
- microsoft flight simulator 2020 user manual pdf
- unity user manual pdf
- apple iphone 11 user manual pdf
- onenote user manual pdf
- user manual for iphone 11 pro
- kindle user manual pdf