TFE/TFE-R

[Pages:2]? Operating temperature range -67oC t o +250oC

? Highly flame retarded

? Excellent chemical resistance

? Shrink ratio 1.8:1 TFE Shrink ratio 3.2:1 TFE-R

TFE/ TFE-R

High temperature,chemically inert,heat-shrinkable tubing

Raychem TFE and TFE-R are heatshrinkable tubings manufactured from a modified Teflon (Polytetrafluoroethylene), an excellent high temperature covering and insulation material w ith a milk-w hite translucence. TFE is the general purpose tubing for difficult chemical and thermal environments. TFER has the added advantages of thin w all, high shrink ratio, greater flexibility and

transparency in application. TFE and TFER are highly flame retarded and exhibit outstanding chemical and solvent resistance w ith electrical characteristics which remain stable over a wide temperature range. The operating

temperature ranges from -67 ?C to +250 ?C, and up to 400?C for short

periods.

The major uses of these materials are for electrical insulation, protection of electronic components and the covering of hydraulic hose and couplings preventing contamination and corrosion. The high mechanical strength and extremely low coefficient of friction make it ideal for reducing damage to bearing shafts, etc.

Ordering information

W

D

d

Inside diamet er

D (min) Expanded as supplied

mm mm

TFE TFE-R

0.8 2 .0

0.9 3 .2

1.1 6 .4

1.2 9 .5

1.4 12 .7

1.5 15 .9

1.9 19 .0

2.3 25 .4

3.0 32 .0

3 .8

-

4 .8

-

6 .1

-

7 .6

-

9 .4

-

1 0 .9

-

1 1 .9

-

d (max) Recovered af t erheat ing mm mm TFE TFE-R 0.3 8 0 .6 0.4 6 1 .0 0.5 6 1 .6 0.6 8 2 .4 0.8 1 3 .7 0.9 9 4 .5 1.2 4 5 .7 1.5 5 7 .1 1.8 3 8 .8 2.2 6 2.8 4 3.5 8 4.5 2 5.6 9 7.0 6 8.8 1 -

Standard colours

Colour Code

Wall thickness W (nom) Recovered aft er heat ing mm mm TFE TFE-R 0 .2 3 0.2 3 0 .2 3 0.2 5 0 .2 5 0.3 0 0 .2 5 0.3 0 0 .3 0 0.3 8 0 .3 0 0.3 8 0 .3 0 0.3 8 0 .3 0 0.3 8 0 .3 0 0.3 8 0 .3 0 0 .3 0 0 .3 8 0 .3 8 0 .3 8 0 .3 8 0 .3 8 -

Standard package

1.2 m lengt h quant it y

m

m

TFE TFE-R

18

12

18

12

18

12

18

6

18

6

18

6

18

6

18

6

18

6

12

-

12

-

6

-

6

-

6

-

6

-

6

-

Ordering description

TFE

TFE-R

TFE-30-X TFE-28-X TFE-26-X TFE-24-X TFE-22-X TFE-20-X TFE-18-X TFE-16-X

TFE-R-5/ 64-X TFE-R-1/ 8-X TFE-R-1/ 4-X TFE-R-3/ 8-X TFE-R-1/ 2-X TFE-R-5/ 8-X TFE-R-3/ 4-X TFE-R-1 -X

TFE-14-X TFE-12-X

TFE-R-11/ 4-X -

TFE-10-X

-

TFE-8-X

-

TFE-6-X

-

TFE-4-X

-

TFE-2-X

-

TFE-0-X

-

The largest size w hich w ill recover snugly over the component to be covered should be ordered.

With TFE-R the maximum outside diameter of the device to be encapsulated should be less than 2 0%of the minimum expanded inside diameter of the tubing. The w all thickness of the tubing w ill be less than specified if recovery is restricted during shrinkage.

Other lengths and sizes are available subject to special order.

Clear X

Temperature rating

TFE/ TFE-R

Operating temperature range: M inimum full recovery temperature:

-6 7? C to +2 50?C +34 0? C

Approvals

M IL-DTL-23 053 / 12 AMS 3584, 3585

Def Std 5 9-9 7 Type 5A (TFE)

Def Std 5 9-9 7 Type 5B (TFE-R) BS 3 G 1 98 Type 21A (TFE) BS 3 G 1 98 Type 21B (TFE-R)

Performance

Test Heat shock: Heat ageing: Dielectric strength: Fluid resistance:

Special installation instructions

Specif icat ions

Test met hod ASTM D2 671 (4 h at 4 00? C) ISO 18 8 (168 h at 3 50? C) IEC 243

Test requirement

No dripping, cracking or flow ing

Ultimate elongation:

15 0%(min)

27 .5 M V/ m (min)

Inert

For full product performance details consult Raychem Specification TFE RW 205 5 TFE-R RW 2 05 4.

For optimum performance TFE and TFE-R must be heated above their crystaline melting points, 3 27?C. As the tubing reaches this temperature, it turns from a milk-w hite translucence to a completely transparent material - at this point the heat source should be removed, as 2 0%-30 %of shrinkage occurs as the tubing cools and returns to its original appearance.

Raychem Specification TFE RW 2 05 5 TFE-R RW 2 05 4. M aterial Safety Data Sheet available on request. Installation instructions available on request.

Raychem Int erconnect Cheney M anor Industrial Estate Sw indon, Wiltshire SN2 2QE Tel: (44 )-17 93-528 17 1 Fax: (44 )-17 93-616 65 2

Raychem and TFE/ TFE-R are trademarks of Raychem Interconnect, a division of Tyco Electronics

Corporation.

All of the above information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Tyco Electronics makes no warranties as to the accuracy or completeness of the information and disclaims any liability regarding its use. Tyco Electronics only obligations are those in the Standard Terms and Conditions of Sale for this product and in no case will Tyco Electronics be liable for any incidental, indirect or consequential damages arising from the sale, resale, use or misuse of the product. Tyco Electronics Specifications are subject to change without notice. In addition Tyco Electronics reserves the right to make changes in materials or processing, without notification to the Buyer, which do not affect compliance with any applicable specification.

RI0 045 .129 9

................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download