UQ-POWER DIESEL GENERATOR Powered by Kubota Model:KE37

UQ-POWER DIESEL GENERATOR

Powered by Kubota Model:KE37

*Silent Type Unit Shown Above

GENERAL DATA

Prime Power Continuous

kW/kVA

Power Standby Power kW/kVA

kW/kVA

Frequency

Hz/rpm

Voltage

V

Current

A

Connection

/

Rated Power Factor

/

Open TypeL?W?H

inches

Open Type(Weight)

lbs

Silent TypeL?W?H

inches

Silent Type(Weight)

lbs

37.0

46.0

33.0

41.0

40.0

50.0

60

1800

208

120

140

3P 4W Series

0.8pf

66.94?40.75x54.5

1984

[x56.7

2645

Available in the following voltages 120/208, 277/480, 120/240( both single and three phase)

All data based on ISO 3046, altitude 1000m (361ft), barometric pressure 100kPa (29.53inHg), air temperature 25 (77? F), relative humidity 30%.

Please contact UQ-Power for correct generator capacity selection when the load application can't meet with the standard reference. UQ-Power diesel generators comply with standards ISO8528ISO 14000ISO3046GB755BS5000VDE0530, ISO3046IEC34-1

All data is subject to change without notice.

Page 1of 5

C .ONSTFIAGNUDRAARTDION

Standard Unit Configuration

Engine Alternator Radiator

Brand new Kubota Diesel Engine, to include air filter, fuel filters, oil filter, starting motor and charging Alternator YANAN SLG brushless AC alternator with Yanan YA460F or YA440 50, fan with protective shroud

Base frame

Base mounted fuel tank, fuel meter, rubber anti-vibration pads, battery holder 500KW: channel steel base frame

Circuit Breaker Engine Control System Start Battery Exhaust System Documents

Molded case circuit breaker (MCCB)

DEEP SEA 6020 Lead-acid battery, connection cables. Flex exhaust, Elbow and flange, Exhaust silencer, etc. UQ-Power standard,Mechanical drawing, electric drawing, operation & maintenance manual, certification etc.

Optional available Equipment

Engine accessories

Heavy-duty air filter Coolant heater Lub oil heater Fuel and Water Separator

Cooling system

Control System

Circuit Breaker Automatic Transfer Switch

50 radiator Heat exchanger + water cooling tower + External water circulation pumping system

Remote horizontal water tank system

OtherComap controls inc

2, 3 and 4 pole, thermo-magnetic

ATS- available in Nema 1 and 3R, 2 and 3 pole

Optional Fuel Tank

Double wall tank available in 8, 12, and 24 hour sizes

uq-

All data is subject to change without notice..

Page 2of 5

ENGINE DATA Engine

Model

V3600

Aspiration Type

Aspirated Vertical in line

No. of Cylinders

4

Governor Type

Mechanical Governor

FuelSystem

Prime power Fuel consumption

Fuel #

3.18 gallns/hour at full Load

D(ASTMD975)

Lubrication System

Lub Oil Capacity Lub #

13.2

L

CF

Coolant System

Coolant Capacity

10

L

Std. Thermostat (Modulating)

71

Range

Engine power Displacement Bore?Stroke Compression Ratio Rated Speed

48

kW

3.620

L

98x120

mm

23:1

1800

RPM

Injection System

Bosch Type

Lub Oil Consumption

NA

l/h

Max.Temperature

121

Max. Top Tank Temp.

110

Air Intake System

Air intcke

Naturally Aspirated

Air Pressure

Exhaust System

Exhaust Gas Flow

Single exhaust

Max.Back Pressure

1.96

kPa

7.07

kPa

uq-

Starting System

Start Mode

Electric start

Battery

All data is subject to change without notice.

80

Ah

Page 3of 5

ALTERNATOR DATA

Alternator Model

Yanan SLG224C

PF.

0.8

Phase

3

Connection

3P 4WY

Winding Pitch

connection 2/3

Insulation Class

H/H

Tel. Influence

TIF50

Harmonic

THF2%

Coefficient Voltage

?5%

Adjust Scope

CONTROL SYSTEM DATA

Rate Power Voltage Frequency Bearing Proteccion Class Efficiency Voltage Regulation AVR Excitation System

44/55

kW/kVA

208/120 V

60

Hz

Single Bearing

IP21

80.70%

?1.0%

YN440

Self-excited

MODEL DSE6020

Control Panel features

Electronic J1939 (CAN) and Modbus capable. MPU and alternator

sensing engine support for diesel,and gas engines all in one

controller. With a large number of flexible inputs, outputs and

protection circuits.

The modules can be easily adapted to suit a wide range of

applications.

Key Functions

utility voltage sensing

Configurable staged loading

Configurable remote start input

Generator/load power monitoring CAN, MPU and alternator

alternative configuration

(kW, kV A, kV Ar, pf)

speed sensing in one variant

alarm including common alarm,common

Generator overload protection (kW) alarms

Efficient power save mode

mains and generator closed via front panel 4 configurable DC outputs

3 engine maintenance engine speed protection Engine pre-heat Multiple date and time scheduler Engine idle control for starting

electric and common shutdown

LCD and LED alarm indication

Configurable event log (50)

Heated display option available

4 configurable analog./digitali nputs &s topping

6 configurable digital inputs

Support for 0-10 V & 4-20 mA oil pressure sensors

Fuel pump control

For more information, please visit the Deep Sea Controls website

Battery voltage monitoring

Start on low battery voltage output

uq-

All data is subject to change without notice.

Page 4of 5

WARRANTY POLICY 1.Standard warranty for one year or 1000 hours ( whichever comes first) from sales date. Refer to UQ-Power Diesel Generator Warranty Manual for more details. 2.Maintenance parts( filters, belts,hoses, batteries),improper operation and maintenance failures are excluded from the warranty policy

. DRAWING (for illustration purposes only)

0

0

0

0

e ee =

0

0

0 00

=

=

00 00

.

0 0

0

98.43''

B=

0

aBB=

B==

All data is subject to change without notice, sorry for inform.

Page 5of 5

uq-

................
................

In order to avoid copyright disputes, this page is only a partial summary.