9–45 KW TIER 4 FINAL MOBILE DIESEL POWER GENERATORS
9?45 KW TIER 4 FINAL MOBILE DIESEL POWER GENERATORS
20 kW Open Unit shown with Optional Roller Frame
Designed from the ground up to meet EPA Tier 4 Final emissions regulations
Rugged, heavy duty design and performance
Compact modular designs have been optimized for high performance in minimal space
Quiet and smooth running
Easy installation hook-ups
EPS 9 kW, Tier 4 Final Mobile Diesel Generator Specifications
9 KW ENCLOSED UNIT
9 KW OPEN UNIT
CONFIGURATION
EPS Model Number KW ? Stand-by (1) KW ? Continuous (1) 120 / 240V (Single Phase Continuous Amps) Engine Fuel Consumption (US Gal./hr.) @ 25% / 50% / 100% Load Length (inches) Width (inches) Height (inches) Weight (including oil & antifreeze)
ENCLOSED SERIES10009ENC
9.0 8.0
66.6 / 33.3
Kubota D1105 BG
.31 / .49 / .8
39.42 24.00 24.53 635 lbs.
OPEN SERIES10009MMEO
9.0 8.0
66.6 / 33.3
Kubota D1105 BG
.31 / .49 / .8
39.42 24.00 24.53 583 lbs.
(1) All unit ratings are established at 1.0 power factor, 68 degrees F and 500 ft. above sea level. De-rate unit by 3.5% for every 1000 ft. above 500 ft. and 1% for every 10 degrees F above 68 degrees F.
(2) Sound level tests were performed on a unit in an open environment, pusher-fan model with all 5 generator cooling vents open. A typical installation will result in lower sound levels.
Illustrations shown may include optional equipment. Specifications subject to change without notice.
See back page for features and options.
EPS 12 kW, Tier 4 Final Mobile Diesel Generator Specifications
12 KW ENCLOSED UNIT
12 KW OPEN UNIT
CONFIGURATION
EPS Model Number KW ? Stand-by (1) KW ? Continuous (1) 120 / 240V (Single Phase Continuous Amps) Engine Fuel Consumption (US Gal./hr.) @ 25% / 50% / 100% Load Length (inches) Width (inches) Height (inches) Weight (including oil & antifreeze)
ENCLOSED SERIES10012ENC
12.0 11.0
100 / 50
Kubota V1505 BG
.46 / .73 / 1.19
45.12 24.00 24.53 728 lbs.
OPEN SERIES10012MMEO
12.0 11.0
100 / 50
Kubota V1505 BG
.46 / .73 / 1.19
45.33 24.00 24.53 671 lbs.
(1) All unit ratings are established at 1.0 power factor, 68 degrees F and 500 ft. above sea level. De-rate unit by 3.5% for every 1000 ft. above 500 ft. and 1% for every 10 degrees F above 68 degrees F.
(2) Sound level tests were performed on a unit in an open environment, pusher-fan model with all 5 generator cooling vents open. A typical installation will result in lower sound levels.
Illustrations shown may include optional equipment. Specifications subject to change without notice.
See back page for features and options.
EPS 14 kW, Tier 4 Final Mobile Diesel Generator Specifications
14 KW ENCLOSED UNIT
14 KW OPEN UNIT
CONFIGURATION
EPS Model Number KW ? Stand-by (1) KW ? Continuous (1) 120 / 240V (Single Phase Continuous Amps) Engine Fuel Consumption (US Gal./hr.) @ 25% / 50% / 100% Load Length (inches) Width (inches) Height (inches) Weight (including oil & antifreeze)
ENCLOSED SERIES10015MT4E
14.0 13.3
110.8 / 55.4
Kubota D1503-M-E4BG
.46 / .82 / 1.43
44.22 25.75 26.00 888 lbs.
OPEN SERIES10015MT4O
14.0 13.3
110.8 / 55.4
Kubota D1503-M-E4BG
.46 / .82 / 1.43
43.37 25.75 25.87 798 lbs.
(1) All unit ratings are established at 1.0 power factor, 68 degrees F and 500 ft. above sea level. De-rate unit by 3.5% for every 1000 ft. above 500 ft. and 1% for every 10 degrees F above 68 degrees F.
(2) Sound level tests were performed on a unit in an open environment, pusher-fan model with all 5 generator cooling vents open. A typical installation will result in lower sound levels.
Illustrations shown may include optional equipment. Specifications subject to change without notice.
See back page for features and options.
EPS 20 kW, Tier 4 Final Mobile Diesel Generator Specifications
20 KW ENCLOSED UNIT
20 KW OPEN UNIT
NOTE: 20 kW Enclosed Unit includes separate mounting pod (shown on left) for fuel filter, electric fuel pump, and fuel/water separator which is integrated with the engine electronics.
CONFIGURATION
EPS Model Number KW ? Stand-by (1) KW ? Continuous (1) 120 / 240V (Single Phase Continuous Amps) Engine Fuel Consumption (US Gal./hr.) @ 25% / 50% / 100% Load Length (inches) Width (inches) Height (inches) Weight (including oil & antifreeze)
ENCLOSED S10020J4ENC
20.9 19.4
162 / 81
Kubota D1803TI-E4G
.34 / .68 / 1.50
58.18 25.76 28.77 1,169 lbs.
OPEN S10020T4C3
20.9 19.4
162 / 81
Kubota D1803TI-E4G
.34 / .68 / 1.50
55.63 26.00 28.90 1,138 lbs.
(1) All unit ratings are established at 1.0 power factor, 68 degrees F and 500 ft. above sea level. De-rate unit by 3.5% for every 1000 ft. above 500 ft. and 1% for every 10 degrees F above 68 degrees F.
(2) Sound level tests were performed on a unit in an open environment, pusher-fan model with all 5 generator cooling vents open. A typical installation will result in lower sound levels.
Illustrations shown may include optional equipment. Specifications subject to change without notice.
See back page for features and options.
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- diesel generator set specifications sheet 25 kva
- kubota kj digital series
- kg25kwrc kubota diesel generator radiator cooled rated 25
- power and reliability you can count on absolute generators
- kubota power generators
- phone 0732681062 kubota perkins
- pdf rk power generator
- durable generator
- diesel generator technical data
- kubota generator engines kubota engine
Related searches
- tier 4 nys retirement benefits
- nyc tier 4 pension calculator
- tier 4 credit score
- kohler 45 kw generator manual
- used 45 kw generator
- 45 kw generac generator
- 45 kw generator diesel
- 45 kw generac generator manual
- 45 kw natural gas generator
- liver stage 4 final days
- mobile ac power supply
- glioblastoma stage 4 final stages