Custom Home Design Plan #211 By SDS-CAD Specialized Design ...

Sample House Plan Plans for as low as $9.99

Custom Home Design Plan #211

By SDS-CAD Specialized Design Systems

BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS.

BUILD AS PER UBC, IRC OR CURRENT LOCAL CODE REQUIREMENTS

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8

Cover Page Main Floor Plan Foundation Plan Elevation Plan Typical Section Details Floor and Roof Framing Plan Cabinet & Main Electrical Misc Details

Sample House Plan

To the best of my knowledge these plans are drawn to comply with owner's and/ or builder's specifications and any changes made on them after prints are made will be done at the owner's and / or builder's expence and responsibility. The contractor shall verify all dimensions and enclosed drawing. SDSCAD is not liable for errors once construction has begun. While every affort has been made in the preparation of this plan to avoid mistakes, the maker can not guarantee against human error. The contractor of the job must check all dimensions and other details prior to construction and be solely responsible thereafter. All calculations and member sizing should be verified for your building by a certified building official.

Note: Paper size 11 x 17 B - size, scale is as stated if printed on 22 x 34 - D size scale is 2X @COPYRIGHT SDSCAD Specialized Design Systems

CLIENT DATE

DRWN BY CHK'D BY DATE REVISIONS

JOB NO.

SHEET NO.

1

OF

8

SDS-CAD Specialized Design Systems

P O Box 374 Mendon, Utah email: sdscad@

Residential Design

Residential Design

SDS-CAD Specialized Design Systems

P O Box 374 Mendon, Utah email: sdscad@

Sample House Plan Plans for as low as $9.99

VENTING SCHEDULE

Range Hoods All Bath Fans Dryer Vent

Vent Through Roof Vent to Exterior Vent to Exterior

INSULATION SCHEDULE

Ceilings Wall above grade Wall interior below grade

R-38 Min R-19 Min R-13 Min

NUMBER W01 W02 W03

QTY 1 3 2

FLOOR 1 1 1

SIZE 3030 3040 6240

WINDOW SCHEDULE

DIMENSIONS WIDTH

36"X36"

36 "

36"X48"

36 "

74"X48"

74 "

HEIGHT 36 " 48 " 48 "

DESCRIPTION DOUBLE HUNG DOUBLE HUNG MULLED UNIT

NUMBER D01 D02 D03 D04 D05 D06

QTY 2 5 1 5 1 1

FLOOR 1 1 1 1 1 1

SIZE 1668 2668 3068 4068 6068 6268

DOOR SCHEDULE

DIMENSIONS WIDTH

17 3/4X80X1 3/8" 18 "

30X80X1 3/8" 30 "

36X80X1 3/4" 36 "

24X80"

24 "

72X80"

72 "

37X80"

37 "

HEIGHT 80 " 80 " 80 " 80 " 80 " 80 "

DESCRIPTION 4-PANEL 4-PANEL EXT. CROSS@BUCK BIFOLD EXT. SLIDER-GLASS BIFOLD

48'-0"

10'-6"

2'-2"

5'-5"

2'-2"

10'-4"

5'-5"

12'-0"

3'-8"

3'-0"

3'-8"

3040

3'-0"

12'-0" 6'-2"

6240

24'-0"

2'-2"

2'-10"

1'-10"

9'-10" 6'-0"

6068

2'-0"

4068

3'-0" 3'-0"

4068

3'-0" 3'-0"

2668

1'-8"

MASTER BDRM

11'-6" x 11'-6"

4'-2"

4'-4" 1'-9"

2668

BATH

8'-0" x 5'-0"

2668 4068

10'-6"

2'-2"

WH 6268

3'-7 1/2" 3'-7 1/2"

BEDROOM

10'-5" x 9'-11"

3'-2" 3'-0"

4068

2'-4" 1'-9" 6"1'-3"

2668

2668

2'-0"

7'-10"

1668

2668

BATH

8'-0" x 5'-0"

1668

4068

3'-2" 3'-0"

2668

2'-4" 1'-9"

2668

LIVING

11'-5" x 16'-10"

BEDROOM

11'-6" x 10'-0"

3068

1'-0" 3'-0"

3040

3'-0"

PORCH

11'-5" x 5'-6"

2'-0"

3'-0"

6240

6'-2" 12'-2"

DN

3'-0" 1'-0" 3'-0" 24'-0"

2'-10" 3'-0" 2'-0" 11'-10"

3040

3'-0"

1'-0"

13'-4" 17'-4"

9'-0"

3030

3'-0" 24'-8"

12'-8"

6'-0"

48'-0"

CLIENT DATE

DRWN BY CHK'D BY DATE

REVISIONS

MAIN FLOOR PLAN

SCALE 1/8"=1'

Sample House Plan

Note: Paper size 11 x 17 B - size, scale is as stated if printed on 22 x 34 - D size scale is 2X @COPYRIGHT SDSCAD Specialized Design Systems

JOB NO.

SHEET NO.

2

OF

8

Residential Design

SDS-CAD Specialized Design Systems

P O Box 374 Mendon, Utah email: sdscad@

41'-8"

48'-0"

Sample House Plan Plans for as low as $9.99

Concrete: 1. All slabs are to be 4" concrete over 4" gravel unless otherwise noted on the plans. 2. Concrete to be ACI 301-66, Type II cement, 2500 psi at 28 days, 5" maximum slump. 3. Reinforcing to be ASTM A615-Bars with Fy=60 ksi lamp 30 diameter

minimum at splices or weld per ACI Std. 4. Concrete design based on Fc 2000 psf, Fc 2500 psi for quality only. 5. Anchor bolts shall be A-307 embedded 7" minimum into concrete or masonry grout.

BRACED WALLS BWP AND ALT BRACED WALL ABWP OPTIONS Brace all exterior walls and cross-stud partitions at each end of building and at least every 25' of length by one of the following: a. Simpson WB 126 wall bracing with 3-16d nails at each

end and 1-8d nails at each stud. b. Plywood sheathing of a minimum thickness of 3/8 inch. c. Continuous bracing from floor to floor

Simpson HPAHD strap location marker See detail for cantilever

FOOTING SCHEDULE

HOUSE WALLS DECKS & PORCHES BEARING WALL GARAGE WALL

20" x 10" Min 18" x 10" Min 20" x 10" Min 18" x 10" Min

Min 2 #4 Rebar Horizontal on undisturbed or compacted soil

48'-0"

24'-0"

24 x 24 x 10 footing 6 x 6 PT post equally spaced 5 1/2" x 11 7/8" LVL Beam

BRACED WALL PANEL 4X8 SHT. ON FOUNDATION.

NAIL W/8d NAILS @6" O.C. EDGES @12" O.C. IN FIELD. NAIL BOTTOM TO SILL PLATE.

12'-0"

ALTERNATE BRACE WALL PANELS PROVIDE (2) STRAPS FOR B.W.P.

FOUNDATION PLAN SCALE 1/8"=1'

Sample House Plan

24'-0"

12'-0"

Note: Paper size 11 x 17 B - size, scale is as stated if printed on 22 x 34 - D size scale is 2X @COPYRIGHT SDSCAD Specialized Design Systems

CLIENT DATE

DRWN BY CHK'D BY DATE

REVISIONS

JOB NO.

SHEET NO.

3

OF

8

6'-4"

Residential Design

SDS-CAD Specialized Design Systems

P O Box 374 Mendon, Utah email: sdscad@

Sample House Plan Plans for as low as $9.99

RIGHT ELEVATION

SCALE 1/8"=1'

6/12 PITCH

LEFT ELEVATION

SCALE 1/8"=1'

Exterior Finish to be determined by homeowner and to meet subdivision requirements

ARCHITECTURAL ASHPHALT SHINGLES

Siding

CLIENT DATE

DRWN BY CHK'D BY DATE

REVISIONS

FRONT ELEVATION

SCALE 1/4"=1'

Sample House Plan

REAR ELEVATION

SCALE 1/4"=1'

Note: Paper size 11 x 17 B - size, scale is as stated if printed on 22 x 34 - D size scale is 2X @COPYRIGHT SDSCAD Specialized Design Systems

JOB NO.

SHEET NO.

4

OF

8

Sample House Plan Plans for as low as $9.99

Roof Framing:

1.

Fascia to be 2"x Douglas Fir.

2.

For soffit size see details.

3.

For spans and dimensions refer to floor plans.

4.

Trusses are to be an approved truss design from the truss manufacture's engineer.

Install as per engineers specs

5.

Use Simpson H-1 hurricane anchors at each truss or rafter to wall connection.

6.

Solid blocking required between joists, rafters, and trusses over all bearing walls.

Such blocking shall be 1 ?" minimum thickness and full depth of joists, rafters, or trusses.

7.

Minimum header sizes shall be according to the header size table unless otherwise noted.

8.

Basis of design roof live/snow load of 37 psf, and roof dead load of 15 psf.

9.

Plywood roof decking to be Min ?" thick, 24/0, CDX or 5/8 wafer.

MAIN FLOOR FRAMING

SCALE 1/16"=1'

9 1/2" I-Joists 16" o.c Floor Joists.

SEE GENERAL SPECS AND NOTES FOR FRAMING DETAILS

PRE-ENGINEERED ENERGY TRUSSES AS SUPPLIED BY TRUSS MANUFACTURER 1. Trusses to be 24" O.C. 2. Attic access min 22 1/2" x 30" were most convenient. For all areas greater than 30" 3.Place vaults where possible as indicated on the floor plan 4. Install all trusses as per truss manufacturer installation guidelines. 5. 8/12 and 6/12 Pitch

Sample House Plan

ROOF FRAMING

SCALE 1/16"=1'

8/12 Pitch

CLIENT DATE

DRWN BY CHK'D BY DATE

REVISIONS

Note: Paper size 11 x 17 B - size, scale is as stated if printed on 22 x 34 - D size scale is 2X @COPYRIGHT SDSCAD Specialized Design Systems

JOB NO.

SHEET NO.

5

OF

8

SDS-CAD Specialized Design Systems

P O Box 374 Mendon, Utah email: sdscad@

Residential Design

................
................

In order to avoid copyright disputes, this page is only a partial summary.