INTEGRATED - York

[Pages:16]INTEGRATED COOLING

SOLUTIONS

YORK? Air-Conditioning Systems

YORK? AIR-CONDITIONING SYSTEMS

Commercial Air Conditioners Summary Table

Type/Cooling Capacity (Btu/Hr)

4 Way Cassette

Single Split Inverter (R410A)

Floor / Ceiling Suspended

Ducted

18K YEKE18BXE

24K YKJE24BXE

YEKE24BXE

36K YKJE36BXB

YEKE36BXE

40K YFJE40BXE

48K

55K

YKJE48BXB YFJE55BXO

YEKE48BXE

YEKE55BXE

Type/Cooling Capacity

8HP

10HP

12HP

15HP

18HP

20HP

24HP

25HP

30HP

35HP

40HP

Indoor

AirCooled Package

NonInverter (R410A)

Standard (Side Throw)

Outdoor

MAK75 YHK75

MAK100 MAK125 MAK150 YHK100 YHK125 YHK150

Optional (Top

Throw)

MAK200

YHK100 (x2)

MAK250 MAK300 MAK350 MAK400

YHK125 (x2)

YHK150 (x2)

YHK125 (x2) +

YHK100

YHK100 (x4)

AirCooled Package

NonInverter (R407C)

Indoor Outdoor

EU090

EU120

CE090

CE120

EU180 CE180

EU240 CE240

EU300

EU360

EU480

CE300

CE350

CE400

Type/Cooling Capacity

WaterCooled Package (R407C)

Duct Type

45HP YEW45

50HP YEW50

55HP YEW55

60HP YEW60

65HP YEW65

2

Pictures shown are for illustration purposes only. Actual product may vary due to product enhancement.

70HP YEW70

80HP YEW80

90HP

100HP

YEW90

YEW100

YORK? AIR-CONDITIONING SYSTEMS

Single Split Inverter 4 Way Cassette (R410A)

Model

Power supply

System Piping Connections

Indoor

Outdoor

Cooling Capacity

Running Current Refrigerant Liquid

Gas Drain Max Pipe Length Max Pipe Height Airflow Rate (L/M/H) Sound Level (L/M/H) Body Dimensions Panel Dimensions Body Weight Panel Weight Rated Current Input Power Sound Level Dimensions Weight

Indoor Outdoor V / Hz / ? Rated (Min-Max) kW Rated (Min-Max) Btu/Hr

Rated (Min-Max) A Type

mm (inch)

m CMH dB(A)

W x H x D (mm)

Kg Kg A W dB(A) W x H x D (mm) Kg

YKJE24BXE YUJE24BYE

7.03 (1.20-8.21) 24,000

(4,100-28,000)

YKJE36BXB YUJE36BYB 220 - 240V / 50Hz / 1? 10.55 (2.93-12.02)

36,000 (10,000-41,000)

YKJE48BXB YUJE48BYB

14.00 (3.99-16.12) 47,700

(13,600-55,000)

9.9 (1.8-14.4)

13.8 (4.2-23.1)

20.5 (5.8-28.0)

R410A

9.52 (3/8")

15.9 (5/8")

19.1 (3/4")

32 (1-1/4")

50

65

25

30

1100 / 1250 / 1450

1470 / 1660 / 1820

1560 / 1740 / 1860

39 / 42 / 46

45 / 49 / 51

47 / 50 / 53

840 x 245 x 840

840 x 287 x 840

950 x 55 x 950

24

29

5

6.5

6.95

5.10

6.85

1970

2600

3420

60

63

64

845 x 702 x 363

946 x 810 x 410

952 x 1,333 x 410

49

69

101

Standard

Optional

Note:

1. Unit comes with standard wireless controller. Optional wired controller to be sold seperately.

2. Unit comes with built-in drain pump.

3. Cooling capacity is based on indoor temp. of 24?C DB / 19?C WB, and outdoor temp. of 35?C DB.

4. This specification is subjected to change without prior notice.

5. Pictures shown are for illustration purposes only. Actual product may vary due to product enhancement.

3

YORK? AIR-CONDITIONING SYSTEMS

Single Split Inverter Floor / Ceiling Suspended (R410A)

Model

System

Piping Connections

Indoor

Outdoor

Power supply

Cooling Capacity

Running Current Refrigerant

Liquid

Gas

Drain Max Pipe Length

Max Pipe Height Airflow Rate (L/M/H) Sound Level (L/M/H) Body Dimensions Body Weight Rated Current Input Power Sound Level

Dimensions Weight

Indoor Outdoor V / Hz / ? Rated (Min-Max) kW Rated (Min-Max) Btu/Hr Rated (Min-Max) A

Type

mm (inch)

m

CMH

dB(A)

W x H x D (mm) Kg A W

dB(A) W x H x D (mm)

Kg

YFJE40BXE YUJE40BYE 220 - 240V / 50Hz / 1? 11.05 (4.10-16.41) 37,600 (14,000-56,000)

YFJE55BXO YUJE55BYO 380 - 415V / 50Hz / 3? 15.82 (4.98-18.11) 54,000 (17,000-61,800)

14.5 (6.0-27.4)

10.5 (2.9-12.0)

R410A 9.52 (3/8") 15.9 (5/8")

25 (1") 65 30

1400 / 1800 / 2100

1280 / 1660 / 2250

41 / 46 / 52

45 / 50 / 55

1,650 x 235 x 675

38.2

40.5

6.85

3420

65

62.5

952 x 1,333 x 410

95.1

112.8

Standard

Optional

Note:

1. Unit comes with standard wireless controller. Optional wired controller to be sold seperately.

2. Drain pump is not supplied.

3. Cooling capacity is based on indoor temp. of 24?C DB / 19?C WB, and outdoor temp. of 35?C DB.

4. This specification is subjected to change without prior notice.

4

5. Pictures shown are for illustration purposes only. Actual product may vary due to product enhancement.

YORK? AIR-CONDITIONING SYSTEMS

Single Split Inverter Ceiling Ducted (R410A)

Model

Indoor Outdoor

YEKE18BXE YUKE18BYE

YEKE24BXE YUKE24BYE

YEKE36BXE YUKE36BYE

YEKE48BXE YUKE48BYO

YEKE55BXE YUKE55BYO

System

Power supply V / Hz / ?

Cooling Capacity

Rated (Min-Max) kW

Rated (Min-Max) Btu/Hr

Running Current

Rated (Min-Max) A

220 - 240V / 50Hz / 1?

5.28 (0.79-6.15)

7.03 (1.20-8.21)

10.55 (2.93-12.02)

18,000 (2,700-21,000)

24,000 (4,100-28,000)

36,000 (10,000-41,000)

7.0 (1.2-10.80)

9.9 (1.8-14.4)

18.5 (4.2-20.1)

380-415V / 50Hz / 3?

14.07 (4.10-16.41)

16.12 (4.98-18.11)

48,000

55,000

(14,000-56000) (17,000-61,800)

8.46 (2.4-10.9) 11.12 (2.9-12.0)

Refrigerant

Type

R410A

Liquid

6.35 (1/4")

9.52 (3/8")

Gas

mm (inch)

12.7 (1/2")

15.9 (5/8")

Piping Connections

Drain

Max Pipe Length

Max Pipe Height

Airflow Rate (L/M/H)

Indoor

External Static Pressure

Sound Level

m

CMH Pa

dB(A)

25 (1")

30

50

20

25

691 / 862 / 939 487 / 782 / 1099 572 / 1108 / 1424

0-70 58

0-100 62

0-120 62

65

30

1132 / 1739 / 2097

1802 / 2165 / 2506

0-160

71

75

Body Dimensions

W x H x D (mm)

880 x 210 x 674

1100 x 249 x 774 1360 x 249 x 774

1200 x 300 x 874

Body Weight

Kg

25.4

31.7

40.2

46

Rated Current

A

7.32

6.95

5.10

6.85

Outdoor

Input Power Sound Level

W dB(A)

1,035 64

1,970 65

2,600 66

3,420

72

75

Dimensions W x H x D (mm)

Weight

Kg

800 x 554 x 333 35.5

845 x 702 x 363 49

946 x 810 x 410 67.2

952 x 1333 x 410

98.1

98.8

Standard

Optional

Note:

1. Unit comes with standard wired controller. Optional wireless controller and receiver extension wire to be sold seperately.

2. Unit comes with washable fliter. Drain pump is not supplied.

3. Cooling capacity is based on indoor temp. of 24?C DB / 19?C WB, and outdoor temp. of 35?C DB.

4. This specification is subjected to change without prior notice.

5. Pictures shown are for illustration purposes only. Actual product may vary due to product enhancement.

5

YORK? AIR-CONDITIONING SYSTEMS

Air-Cooled Package Non-Inverter (R410A)

Model

System

Piping Connections

Cooling Capacity

Running Current

Liquid

Gas

Drain

Max Pipe Length

Max Pipe Height

Indoor Outdoor

kW Btu/Hr

A

mm (inch)

m

Power supply

V / Hz / ?

Indoor Outdoor

Airflow Rate (High) External Static

Pressure Sound Level

(L/M/H) Dimensions

Weight Power supply

Compressor

Sound Level Dimensions

Weight

CMH

Pa

dB(A)

W x H x D (mm) Kg

V / Hz / ? Rated / Max Current (A) Input Power (kW)

Type dB(A) W x H x D (mm)

Kg

MAK75 YHK75 21.98 75,000

20.3

28.6 (1-1/8")

25

MAK100 YHK100

29.31 100,000

MAK125 YHK125

36.64 125,000

26.1

27.5

15.9 (5/8") 35 (1-3/8")

19.05 (3/4")

30

MAK150 YHK150

43.96 150,000

33.0

15

220 - 240V / 50Hz / 1?

4,250

4,760

20

380 - 415V / 50Hz / 3?

6,970

8,500

100

100

150

150

54 / 58 / 62 1580 x 485 x 765

109

16.4 / 95 6.88

67

152

57 / 62 / 65

67

69

1580 x 550 x 765

1615 x 870 x 985

130

185

197

380 - 415V / 50Hz / 3?

19.2 / 125

22.1 / 125

24.2 / 175

9.13 Scroll

70 965 x 795 x 975

156

10.20 72 163

13.62

74 1227 x 945 x 1105

189

Standard

Note:

1. Unit comes with standard wired controller only.

2. Drain pump and air filter are not supplied.

3. Cooling capacity is based on indoor temp. of 24?C DB / 19?C WB, and outdoor temp. of 35?C DB.

4. This specification is subjected to change without prior notice.

6

5. Pictures shown are for illustration purposes only. Actual product may vary due to product enhancement.

YORK? AIR-CONDITIONING SYSTEMS

Air-Cooled Package Non-Inverter (R410A)

Model

Indoor Outdoor

System

Cooling Capacity

Running Current

kW Btu/Hr

A

Liquid

Piping Connections

Indoor

Gas

Drain

Max Pipe Length

Max Pipe Height

Power supply

Airflow Rate

External Static

Pressure

Sound Level (Lo/Mi/Hi)

mm (inch)

m V / Hz / ?

CMH Pa

dB(A)

Dimensions W x H x D (mm)

Outdoor (Individual

Unit)

Weight

Kg

Power supply

V / Hz / ?

Compressor

Rated / Max Current (A)

Input Power (kW)

Type

Sound Level

dB(A)

Dimensions W x H x D (mm)

Weight

Kg

MAK200 YHK100 (x2)

58.62 200,000

44.92

MAK250

YHK125 (x2)

73.27 250,000

51.88

15.9 (5/8") x 2 sets

35 (1-3/8") x 2 sets

MAK300 YHK150 (x2)

87.92 300,000

65.70

25 (1") 30

MAK350

YHK125 (x2)

YHK100

102.58

350,000

73.60

15.9 (5/8") x 3 sets

35 (1-3/8") x 3 sets

10,880

13,600

20

380 - 415V / 50Hz / 3?

15,300

19,550

150

200

200

200

68.5

69

71

68

1965 x 875 x 935

200

1935 x 1260 x 1160

2210 x 1155 x 1465

313

323

443

380 - 415V / 50Hz / 3?

19.2 / 125

22.1 / 125

24.2 / 175

22.1 / 125 19.2 / 125

9.13

10.20

72

70

965 x 795 x 975

156

163

13.62 Scroll

74 1227 x 945

x 1105 189

10.20

9.13

72

70

965 x 795 x 975

163

156

MAK400 YHK100 (x4)

117.23 400,000

86.68 15.9 (5/8")

x 4 sets 35 (1-3/8")

x 4 sets

22,950 200

68.5 2365 x 1515

x 1450 496

19.2 / 125 9.13

70 965 x 795

x 975 156

Standard

Note:

1. Unit comes with standard wired controller only.

2. Drain pump and air filter are not supplied.

3. Cooling capacity is based on indoor temp. of 24?C DB / 19?C WB, and outdoor temp. of 35?C DB.

4. This specification is subjected to change without prior notice.

5. Pictures shown are for illustration purposes only. Actual product may vary due to product enhancement.

7

YORK? AIR-CONDITIONING SYSTEMS

Dimensions - Indoor (R410A)

MAK75

MAK100

MAK125, MAK150

8

Dimensions shown are accurate at the time of print and subject to change without prior notice.

................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download