 SECTION 08 71 13AUTOMATIC DOOR OPERATORSDisplay hidden notes to specifier. (Don't know how? Click Here) Copyright 2012 - 2016 ARCAT, Inc. - All rights reserved** NOTE TO SPECIFIER ** DITEC Entrematic North America; automatic door operators, door activation and safety devices.This section is based on the products of DITEC Entrematic North America, which is located at:221A Racco Pkwy.Vaughan, ONCanada L4J8X9Toll Free: 877-348-6837Phone: 416-674-8880Fax: 416-674-8882Email: info.ditec.ca@Web Site: ditecentrematic.caAnd240 Vista Park DrivePittsburgh, PA 15205Toll Free: 866-901-4284Phone: 412-200-5750Fax: 412-200-5751Email: info.ditec.us@Web Site: ww.ditecentrematic.usWe supply our customers with reliable door automation systems and components. Quality products are the foundation of our business. We realize that customers need more than just quality products to succeed in business today. Our top priority is satisfying our customers. Our customers can be certain that we strive to guarantee satisfaction. We believe that our success should be measured by your ability to effectively compete in the Automatic Door Industry.

GENERAL

SECTION INCLUDES

** NOTE TO SPECIFIER ** Delete items below not required for project.

Low energy swing door operators. (HA-8)

Fully automatic swing door operators. (FA-8)

Low profile, low energy swing door operators. (LP-HA-8)

Automatic slide door operators. (DS-18C)

Access control slide door operators. (DS-18C)

Intensive care unit manual sliding door systems. (IC-18)

Intensive care unit manual fold-swing door systems. (FS-IC)

RELATED SECTIONS

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.

Section 06 10 00 - Rough Carpentry.

Section 08 41 00 - Entrances and Storefronts.

Section 08 71 53 - Security Door Hardware.

Section 08 83 13 - Mirrored Glass Glazing.

Section 12 67 00 - Pews and Benches.

Section 26 05 00 - Common Work Results for Electrical.

Section 26 05 19 - Low-Voltage Electrical Power Conductors and Cables.

REFERENCES

** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.

Americans with Disabilities Act (ADA).

Underwriters Laboratories, Inc. (UL): UL 325 - Door, Drapery, Gate, Louver, and Window Operators and Systems.

Builders Hardware Manufacturers Association (BHMA):

ANSI-BHMA A 156.10 - Power Operated Pedestrian Doors.

ANSI-BHMA A 156.19 - Power Assist and Low Energy Power Operated Doors.

Canadian Standards Association: CSA C22.2 - Electrical Code.

American Association of Automatic Door Manufacturers (AAADM).

SUBMITTALS

Submit under provisions of Section 01 30 00 - Administrative Requirements.

Product Data: Manufacturer's data sheets on each product to be used, including:

Preparation instructions and recommendations.

Storage and handling requirements and recommendations.

Installation guides; installation and operating manuals and installation recommendations.

Cleaning methods.

Shop Drawings: Submit shop drawings showing layout, profiles, product components, accessories joining methods, location of components, anchorage details, interface with adjacent construction, dimensions and wiring details and electrical requirements.

Verification Samples: For each product and finish specified, two samples, sized to adequately represent material, representing actual products and finishes.

QUALITY ASSURANCE

Single Source Requirements: To the greatest extent practical provide products specified in this section from a single manufacturer or supplier.

Manufacturer: Minimum 5 years experience producing similar products.

Installer Qualifications: Acceptable to manufacturer.

DELIVERY, STORAGE, AND HANDLING

Deliver, store and handle materials and products in strict compliance with manufacturer's instructions and recommendations and industry standards.

Store materials in manufacturer's original sealed, labeled packaging until ready for installation and in accordance with manufacturer's instructions. Protect from damage.

PROJECT CONDITIONS

Maintain environmental conditions (temperature, humidity and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits.

SEQUENCING AND SCHEDULING

Conference: Convene a pre-installation conference to establish procedures to maintain optimum working conditions and to coordinate this work with related and adjacent work.

WARRANTY

Manufacturer's standard 3-year limited warranty against defects in materials and workmanship.

PRODUCTS

MANUFACTURERS

Acceptable Manufacturer: DITEC Entrematic North America; 221A Racco Pkwy.; Vaughan, ON; Canada L4J8X9. Toll Free: 877-348-6837. Phone: 416-674-8880. Fax: 416-674-8882. Email: info.ditec.ca@entrematic.ca Web Site: ditecentrematic.ca.

Acceptable Manufacturer: DITEC Entrematic USA Inc; 240 Vista Park Drive, Pittsburgh, PA 15205. USA. Toll Free: 866-901-4284. Phone: 412-200-5750. Fax: 412-200-5751. Email: info.ditec.us@ Web Site: ditecentrematic.us.

** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.

Substitutions: Not permitted.

Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.

** NOTE TO SPECIFIER ** The HA-8 AutoSwing door operators have been engineered to open doors for people with disabilities and the elderly. The one way clutch allows the door to be opened manually with incredible ease. The HA-8 AutoSwing incorporates a concealed heavy duty adjustable door stop, therefore eliminating the need for external stops. The HA-8 AutoSwing is equipped with an adjustable heavy-duty spring. Because of this feature, the HA-8 AutoSwing can be used to operate larger, heavier doors in windy conditions. The AutoSwing door operators are designed with the safety of the user in mind and complies with the latest ANSI standards A156.19 for low energy door operation. The HA-8 AutoSwing door operators are noise free in both automatic and manual mode for a pleasant, consumer friendly environment. The HA-8 AutoSwing door operator requires only simple procedures for fast, trouble free installation. The HA-8 AutoSwing is also easily retrofitted to existing doors or new construction without major renovation. The HA-8 AutoSwing is North American made and designed specifically for our weather conditions. The combination of superior construction and technology make the HA-8 AutoSwing door operators the most reliable on the market. Delete if not required.

LOW ENERGY SWING DOOR OPERATORS (HA-8)

Low Energy Swing Door Operators: Model HA-8 as manufactured by DITEC Entrematic North America.

Components: Provide door operating equipment, controls and safety devices, accessories and fasteners as required for complete installation and as scheduled and indicated on Drawings.

System Design: Electro-mechanical system installed in header to resist dust, dirt and corrosion; removable from the header as a unit.

Operating Temperature Range: -30 degrees F to +130 degrees F (-34 degrees C to 54 degrees C).

** NOTE TO SPECIFIER ** Insert finish designations in blanks below as applicable or insert ' As scheduled and indicated on Drawings.' Delete options for finishes not required.

Aluminum Extrusion Finish: As scheduled and indicated on Drawings.

Aluminum Extrusion Finish: Standard, clear anodized.

Aluminum Extrusion Finish: Standard, bronze anodized.

Aluminum Extrusion Finish: Standard, light bronze anodized.

Aluminum Extrusion Finish: Special anodized, color ___________.

Aluminum Extrusion Finish: Painted, color ___________.

Aluminum Extrusion Finish: Clad, ___________.

Headers: Full length removable cover for access to operator, electronic control box.

Materials: 6063-T5 aluminum extrusions with structurally integrated end caps.

Dimensions: 4-1/2 inches (114 mm) wide by 6-1/2 inches (165 mm) high.

Structural Sections: Minimum wall thickness of .125 inch (3.2 mm).

Linkage Assemblies: Shall provide positive control of door through entire swing.

Surface applied permit use on butt-hung or offset pivots.

Concealed permit use on center pivot, butt-hung, and offset pivots.

Bearings: Fully lubricated and sealed to minimize wear and friction.

Operation:

Entrapment Protection Compliance: Door forces and speeds generated during power opening and manual opening in both directions of swing and spring closing in both directions of swing shall conform to the requirements of ANSI A 156.19, UL 325, and Code of Federal Regulations, ADA Standards of Accessible Design paragraph 4.13.12.

Mode of Operation: To be "low energy" as defined by ANSI A 156.19.

Electrical Controls: Electronic controllers with quick connect plugs shall incorporate the features listed below.

Responds to push plates, transmitters and receivers.

Immediate reverse-on-obstruction during opening capability.

Open, back check and closing speed adjustment.

Adjustable time delays.

On/Off/Hold-Open switch.

Drive Trains: Positive constant engagement; operator shall stop the door in the open position by electrically reducing the motor voltage and stalling against stop.

Power Opening: Operator shall open door with a motor through reduction gears splined spindle, door arm and linkage assembly.

** NOTE TO SPECIFIER ** Delete options for motors not required.

Motor: As scheduled and indicated on Drawings.

Motor: Standard, 1/5 HP motor.

Motor: Provide optional 1/4 HP motor.

Spring Close: Closing spring shall be pre-loaded for positive closing action.

Operator shall close door by spring energy.

Employing the motor as a dynamic brake shall control closing speed.

"Low energy" operator door closing time shall not be less than 4.5 seconds.

Manual Operation: Operator shall function as a manual door closer in the direction of swing with or without electrical power. To facilitate easy manual operation of door and to prolong gear and motor life, operator must have a one-way clutch in the gear train.

** NOTE TO SPECIFIER ** The FA-8 Automatic Door operator is used for high traffic commercial applications. The operator can be interfaced with all activation devices by supplying a 24 Volt power supply and a trigger for activation signals. The control has a built in lock-out relay for safety sensors. Both overhead and door mounted safety sensors can be interfaced to the FA-8 control through two separate inputs. The FA-8 operator can be surface applied applications can be mounted on either side of a door frame - providing flexibility in any situation. Delete if not required.

FULLY AUTOMATIC SWING OPERATOR (FA-8)

Fully Automatic Swing Door Operators: Model FA-8 as manufactured by DITEC Entrematic North America.

Components: Provide door operating equipment, controls and safety devices, accessories and fasteners as required for complete installation and as scheduled and indicated on Drawings.

System Design: Electro-mechanical system installed in header to resist dust, dirt and corrosion; removable from the header as a unit.

Operating Temperature Range: -30 degrees F to +130 degrees F (-34 degrees C to 54 degrees C).

** NOTE TO SPECIFIER ** Insert finish designations in blanks below as applicable or insert ' As scheduled and indicated on Drawings.' Delete options for finishes not required.

Aluminum Extrusion Finish: As scheduled and indicated on Drawings.

Aluminum Extrusion Finish: Standard, clear anodized.

Aluminum Extrusion Finish: Standard, bronze anodized.

Aluminum Extrusion Finish: Standard, light bronze anodized.

Aluminum Extrusion Finish: Special anodized, color ___________.

Aluminum Extrusion Finish: Painted, color ___________.

Aluminum Extrusion Finish: Clad, ___________.

Headers: Full length removable cover for access to operator, electronic control box.

Materials: 6063-T5 aluminum extrusions with structurally integrated end caps.

Dimensions: 4-1/2 inches (114 mm) wide by 6-1/2 inches (165 mm) high.

Structural Sections: Minimum wall thickness of .125 inch (3.2 mm).

Linkage Assemblies: Shall provide positive control of door through entire swing.

Surface applied permit use on butt-hung or offset pivots.

Concealed permit use on center pivot, butt-hung, and offset pivots.

Bearings: Fully lubricated and sealed to minimize wear and friction.

Operation:

Entrapment Protection Compliance: Door forces and speeds generated during power opening and manual opening in both directions of swing and spring closing in both directions of swing shall conform to the requirements of ANSI A 156.10.

Mode of Operation: To be "Full energy" as defined by ANSI A 156.10.

Electrical Controls: Electronic controllers with quick connect plugs shall incorporate the features listed below.

Responds to push plates, transmitters, motion and presence detectors and receivers.

Immediate reverse-on-obstruction during opening capability.

Open, back check and closing speed adjustment.

Adjustable time delays.

On/Off/Hold-Open switch.

Power Opening: Operator shall open door with a 1/5 HP motor through reduction gears splined spindle, door arm and linkage assembly. Drive train shall have positive constant engagement. Operator shall stop the door in the open position by electrically reducing the motor voltage and stalling against stop.

Spring Close: Operator shall close door by spring energy.

Employing the motor as a dynamic brake shall control closing speed.

Closing spring shall be pre-loaded for positive closing action.

"Full energy" operator door closing time shall not be less than 4.5 seconds.

Manual Operation: Operator shall function as a manual door closer in the direction of swing with or without electrical power. To facilitate easy manual operation of door and to prolong gear and motor life, operator must have a one-way clutch in the gear train.

** NOTE TO SPECIFIER ** The automatic door operator allows Barrier-Free access, providing customer convenience and meeting the requirements of persons with disabilities. It's the perfect choice for new and existing buildings, permitting easy access to commercial, industrial, and institutional locations. This door is the same as the regular HA-8 swinger but comes in a smaller size for those hard accessible places to install or for the "less package" look. Delete if not required.

LOW PROFILE LOW ENERGY SWING OPERATOR (LP-HA-8)

Low Profile, Low Energy Swing Door Operators: Model LP-HA-8 as manufactured by DITEC Entrematic North America.

Components: Provide door operating equipment, controls and safety devices, accessories and fasteners as required for complete installation and as scheduled and indicated on Drawings.

System Design: Electro-mechanical system installed in a header to resist dust, dirt and corrosion.

Operating Temperature Range: -30 degrees F to +130 degrees F (-34 degrees C to 54 degrees C).

** NOTE TO SPECIFIER ** Insert finish designations in blanks below as applicable or insert ' As scheduled and indicated on Drawings.' Delete options for finishes not required.

Aluminum Extrusion Finish: As scheduled and indicated on Drawings.

Aluminum Extrusion Finish: Standard, clear anodized.

Aluminum Extrusion Finish: Standard, bronze anodized.

Aluminum Extrusion Finish: Standard, light bronze anodized.

Aluminum Extrusion Finish: Special anodized, color ___________.

Aluminum Extrusion Finish: Painted, color ___________.

Aluminum Extrusion Finish: Clad, ___________.

Headers: Full length removable cover for access to operator, electronic control box.

Materials: 6063-T5 aluminum extrusions with structurally integrated end caps.

Dimensions: LOW PROFILE, 5 inches (127 mm) deep x 4 inches (102 mm) high x width of door opening plus 3 inches (76 mm).

Removable Covers: Minimum wall thickness of .10 inches (2.5 mm); no visible fasteners.

Structural Back Plate Sections: Minimum wall thickness of .20 inch (5.1 mm).

Linkage Assemblies: Shall provide positive control of door through entire swing.

Surface applied permit use on butt-hung or offset pivots.

Linkage shall be capable of pushing or pulling the door to the open position.

Bearings: Fully lubricated and sealed to minimize wear and friction.

Operation:

Entrapment Protection Compliance: Door forces and speeds generated during power opening and manual opening in both directions of swing and spring closing in both directions of swing shall conform to the requirements of ANSI A 156.19.

Mode of Operation: To be "low energy" as defined by ANSI A 156.19.

Electrical Controls: Electronic controllers with quick connect plugs shall incorporate the features listed below.

Responds to push plates, transmitters, and receivers.

Reverse-on-obstruction during opening capability.

Open, back check, and closing speed adjustment.

Adjustable time delays.

On/Off/Hold Open Switch.

Push and Go feature is optional.

Drive Trains: Positive constant engagement. Operator shall stop the door in the open position by electrically reducing the motor voltage and stalling against internal stop. Power Opening: Electro-mechanical operator shall open door with a 1/8 HP motor through reduction gears splined spindle, door arm and linkage assembly.

Hydraulically or pneumatically opening door operators will not be acceptable.

Spring Close: Operator shall close door by spring energy.

Employing the motor as a dynamic brake shall control closing speed.

Closing spring shall be pre-loaded for positive closing action at low material stress level.

"Low energy" operator door closing time shall not be less than 4.5 seconds.

Hydraulically or pneumatically closing operators will not be acceptable.

Manual Operation: Operator shall function as a manual door closer in the direction of swing with or without electrical power. To facilitate easy manual operation of door and to prolong gear and motor life, operator must have a one-way clutch in the gear train.

** NOTE TO SPECIFIER ** The Automatic Slide Door slim header design allows the doors to be mounted closer to the center of gravity and this creates a better balanced operation as well as allowing smoother acceleration, smoother braking and longer roller life. Error Info: LED display will show error codes in which it is possible to establish historic performance and error data, such as the amount of times power failure has occurred as well as how many programming changes have been made since the initial installation. Numerous other error code devices can also be established from this useful feature. Memory Function: A unique new Ferrite Chip based upon the FRAM concept (Flash Random Access Memory), controls input data into the control box. Using the FRAM systems, is it possible to write and re-write operational control settings up to 10 Billion times. If the power is turned off, the FRAM system allows memory retention of control box settings for up to 10 years. Delete if not required.

AUTOMATIC SLIDE DOOR OPERATORS (DS-18C)

Automatic Slide Door Operators: Model DS-18C as manufactured by DITEC Entrematic North America.

Components: Provide door operating equipment, guide threshold, actuating and safety controls, accessories and fasteners as required for complete installation and as scheduled and indicated on Drawings.

System Design: Components in the header factory engineered, assembled, adjusted and tested.

Field wiring consists of connection to job-site power and actuators.

The bi-part sliding door system shall include a two-point MS deadlock securing the lead edges of the door stiles together and to the active door carrier assembly or for single slide a one point MS deadlock securing the latch stile to the vertical lock jamb.

Each door panel shall include interlocking that securely latches the swing out panels to the sliding panels in the fully closed position.

The active sliding door shall be provided with a key cylinder on the exterior and a thumbturn on the interior.

Operating Temperature Range: System components shall operate between -70 degrees F and 130 degrees F (-56 degrees C and 54 degrees C).

** NOTE TO SPECIFIER ** Insert finish designations in blanks below as applicable or insert ' As scheduled and indicated on Drawings.' Delete options for finishes not required.

Aluminum Extrusion Finish: As scheduled and indicated on Drawings.

Aluminum Extrusion Finish: Standard, clear anodized.

Aluminum Extrusion Finish: Standard, bronze anodized.

Aluminum Extrusion Finish: Standard, light bronze anodized.

Aluminum Extrusion Finish: Special anodized, color ___________.

Aluminum Extrusion Finish: Painted, color ___________.

Aluminum Extrusion Finish: Clad, ___________.

Door Panels and Sidelights: Sized to prevent pinch points at meeting stiles.

Compliance: Allow "breakout" to full open position to provide instant egress at any point in door's movement.

Sliding Aluminum Doors: Narrow stile through bolted units, to dimensions and with glazing as scheduled and indicated on Drawings and order confirmation; with intermediate rails.

Door Panels: Include interlocking that securely latches the fully closed position.

** NOTE TO SPECIFIER ** Delete options for glass thickness not required.

Door Glass Thickness: As scheduled and indicated on Drawings.

Door Glass Thickness: Stops for 1/4 inch (6 mm) glazing.

Door Glass Thickness: Stops for 5/8 inch (16 mm) glazing.

Aluminum Sidelights: Narrow stile through bolted units, to dimensions and with glazing as scheduled and indicated on Drawings and order confirmation.

** NOTE TO SPECIFIER ** Delete options for glass thickness not required.

Sidelight Glass Thickness: As scheduled and indicated on Drawings.

Sidelight Glass Thickness: Stops for 1/4 inch (6 mm) glazing.

Sidelight Glass Thickness: Stops for 5/8 inch (16 mm) glazing.

Aluminum Frames and Extrusions:

Integral Structural Sections: Minimum .125 inch (3 mm) thickness.

Dimensions: 4-1/2 inches (114 mm) deep x 1-3/4 inches wide (44 mm) section.

** NOTE TO SPECIFIER ** Delete option for transoms not required.

Transom Package: None.

Transom Package: As scheduled and indicated on Drawings.

Transom Package: One vertical transom tube, designed for 1/4 inch (6 mm) glazing.

Transom Package: One vertical transom tube, designed for 1 inch (24 mm) glazing.

Header Cases:

Materials: Extruded aluminum.

Size: 4-1/2 inches wide x 7-1/2 inches high (108 mm x 180 mm).

Capacity: Header shall be capable of supporting a single door leaf of 250 pounds or bi-parting door leaf of 250 pounds each over a span of 18 ft (5.5 m) with deflection within limits established by manufacturer for product application.

Slide System: Digital slide system and door mounting components.

Header Cover: With a continuous hinge, opens flush with top of header.

Door Hanger Wheels:

Materials: Urethane.

Diameter: 2-1/2 inch (64 mm).

Bearings: Precision lifetime lubricated ball bearings.

Anti Riser Blocks: 4 Delrin anti riser block per door, to secure sliding doors to roller tracks, field replaceable.

Adjustability: Doors can be adjusted down up to 1/2 inch (13 mm).

Guide Threshold Track: Guides slide panels from close to open and open to close.

Materials: Aluminum.

** NOTE TO SPECIFIER ** Surface applied track can either be full length or only below sidelights, leaving a clear floor in entrance. Delete options for profiles not required.

Profiles: As scheduled and indicated on Drawings .

Profiles: Recess mounted.

Profiles: Surface mounted double bevel.

Profiles: Surface mounted combination bevel/square; options are field adjustable by snap-off beveled edge.

Drive Systems: Digital Slide System.

Components: Electromechanical 1/5 hp, 100V, brushless DC motor and enclosed hypoid gear system with maximum opening speed of 750 mm/sec.

Power Requirements: Provide 120 VAC, 5 amps single-phase power supply minimum to operator transformer junction box within header.

Control Units: DS-18C Ferrite Chip Control Unit.

Torque shall be factory set as prescribed by ANSI A156.10.

In the event of power failure active doors maybe opened manually.

Microprocessor Controls: Monitors doorway holding beams, door position, electric lock position, activators, motor temperature, and condition of power.

Self-Diagnostics: Checks performed on continuous basis, faults displayed by flashing LED's and buzzer noise on control panels.

Doorway Holding Beams:

Factory installed at 24 inches (610 mm) and 48 inches (1219 mm) from finished floor.

When the beam is interrupted, an open door shall be inhibited from closing.

** NOTE TO SPECIFIER ** Delete options for switches not required.

Switches: As scheduled and indicated on Drawings

Switches: 10 position switch. (10PS)

Switches: 10 position switch with key. (10PK)

Switches: 3 position switch. (3PS)

Switches: 3 position switch with key. (3PK)

Switches: 4 position switch. (4PS)

Switches: 4 position switch with key. (4PK)

Operation:

Motion Detection: Actuated by motion detector mounted on each side of door detection of traffic in each direction.

Reverse Function:

Upon obstruction with Safety Search Circuitry.

Doors shall recycle open if an object is encountered during closing cycle.

Circuitry shall time-out for 5 seconds then search for that object at 50 percent speed on next closing cycle.

If an obstruction is encountered again, doors will recycle open.

Doors shall keep timing-out and recycling at 50 percent speed until obstruction is cleared.

If an object is encountered while opening, the doors will stop, reverse direction one inch, time-out for 5 seconds and close at 50 percent speed.

The next opening the circuitry shall search for that object at 50 percent speed.

If an obstruction is encountered again the doors shall stop reverse direction one inch, time out and close.

The doors shall continue recycling at 50 percent until the object is cleared.

Door Motion Adjustments: Control digital interface provides means to make the following door adjustments; open high speed, open low speed, open braking force, close high speed, close low speed, close braking force, opening time.

Nylon Sweeps:

On bottom of sliding doors.

Double pile weatherstripping for sliding door lead edges.

Single pile weatherstripping between carrier and header on lead stiles of sidelights and pivot stiles of sliding doors.

** NOTE TO SPECIFIER ** The Automatic Slide Door slim header design allows the doors to be mounted closer to the center of gravity and this creates a better balanced operation as well as allowing smoother acceleration, smoother braking and longer roller life. Error Info: LED display will show error codes in which it is possible to establish historic performance and error data, such as the amount of times power failure has occurred as well as how many programming changes have been made since the initial installation. Numerous other error code devices can also be established from this useful feature. Memory Function: A unique new Ferrite Chip based upon the FRAM concept (Flash Random Access Memory), controls input data into the control box. Using the FRAM systems, is it possible to write and re-write operational control settings up to 10 Billion times. If the power is turned off, the FRAM system allows memory retention of control box settings for up to 10 years. Delete if not required.

ACCESS CONTROL SLIDE DOOR OPERATORS (DS-18C)

Access Control Slide Door Operators: Model DS-18C with access control devices as manufactured by DITEC Entrematic North America.

Components: Provide door operating equipment, access control system components, guide threshold, actuating and safety controls, accessories and fasteners as required for complete installation and as scheduled and indicated on Drawings.

Acceptable alternative under code standard is 8600 surface mounted panic device.

Emergency Breakout System: With an 86F recessed panic device in muntin bar.

System Design: Components in the header factory engineered, assembled, adjusted and tested.

Field wiring consists of connection to job-site power and actuators.

The bi-part sliding door system shall include an electric solenoid deadlock securing the active door carrier assemblies together (in the closed position) or for a single slide an electric solenoid deadlock securing the active door carrier assembly to the vertical closing jamb.

The electric solenoid lock shall be classified Fail Safe or Fail Secure.

Each door panel shall include interlocking that securely latches the swing out panel(s) to the sliding panel(s) in the fully closed position.

Operating Temperature Range: System components shall operate between -70 degrees F and 130 degrees F (-56 degrees C and 54 degrees C).

** NOTE TO SPECIFIER ** Insert finish designations in blanks below as applicable or insert ' As scheduled and indicated on Drawings.' Delete options for finishes not required.

Aluminum Extrusion Finish: As scheduled and indicated on Drawings.

Aluminum Extrusion Finish: Standard, clear anodized.

Aluminum Extrusion Finish: Standard, bronze anodized.

Aluminum Extrusion Finish: Standard, light bronze anodized.

Aluminum Extrusion Finish: Special anodized, color ___________.

Aluminum Extrusion Finish: Painted, color ___________.

Aluminum Extrusion Finish: Clad, ___________.

Door Panels and Sidelights: Sized to prevent pinch points at meeting stiles.

Compliance: Allow "breakout" to full open position to provide instant egress at any point in door's movement.

Sliding Aluminum Doors: Narrow stile through bolted units, to dimensions and with glazing as scheduled and indicated on Drawings and order confirmation; with intermediate rails.

Door Panels: Include interlocking that securely latches the fully closed position.

** NOTE TO SPECIFIER ** Delete options for glass thickness not required.

Door Glass Thickness: As scheduled and indicated on Drawings.

Door Glass Thickness: Stops for 1/4 inch (6 mm) glazing.

Door Glass Thickness: Stops for 5/8 inch (16 mm) glazing.

Aluminum Sidelights: Narrow stile through bolted units, to dimensions and with glazing as scheduled and indicated on Drawings and order confirmation.

** NOTE TO SPECIFIER ** Delete options for glass thickness not required.

Sidelight Glass Thickness: As scheduled and indicated on Drawings.

Sidelight Glass Thickness: Stops for 1/4 inch (6 mm) glazing.

Sidelight Glass Thickness: Stops for 5/8 inch (16 mm) glazing.

Aluminum Frames and Extrusions:

Integral Structural Sections: Minimum .125 inch (3 mm) thickness.

Dimensions: 4-1/2 inches (114 mm) deep x 1-3/4 inches wide (44 mm) section.

** NOTE TO SPECIFIER ** Delete option for transoms not required.

Transom Package: None.

Transom Package: As scheduled and indicated on Drawings.

Transom Package: One vertical transom tube, designed for 1/4 inch (6 mm) glazing.

Transom Package: One vertical transom tube, designed for 1 inch (24 mm) glazing.

Header Cases:

Materials: Extruded aluminum.

Size: 4-1/2 inches wide x 7-1/2 inches high (108 mm x 180 mm).

Capacity: Header shall be capable of supporting a single door leaf of 250 pounds or bi-parting door leaf of 250 pounds each over a span of 18 ft (5.5 m) with deflection within limits established by manufacturer for product application.

Slide System: Digital slide system and door mounting components.

Header Cover: With a continuous hinge, opens flush with top of header.

Door Hanger Wheels:

Materials: Urethane.

Diameter: 2-1/2 inch (64 mm).

Bearings: Precision lifetime lubricated ball bearings.

Anti Riser Blocks: 4 Delrin anti riser block per door, to secure sliding doors to roller tracks, field replaceable.

Adjustability: Doors can be adjusted down up to 1/2 inch (13 mm).

Guide Threshold Track: Guides slide panels from close to open and open to close.

Materials: Aluminum.

** NOTE TO SPECIFIER ** Surface applied track can either be full length or only below sidelights, leaving a clear floor in entrance. Delete options for profiles not required.

Profiles: As scheduled and indicated on Drawings .

Profiles: Recess mounted.

Profiles: Surface mounted double bevel.

Profiles: Surface mounted combination bevel/square; options are field adjustable by snap-off beveled edge.

Drive Systems: Digital Slide System.

Components: Electromechanical 1/5 hp, 100V, brushless DC motor and enclosed hypoid gear system with maximum opening speed of 750 mm/sec.

Power Requirements: Provide 120 VAC, 5 amps single-phase power supply minimum to operator transformer junction box within header.

Control Units: DS-18C Ferrite Chip Control Unit.

Torque shall be factory set as prescribed by ANSI A156.10.

In the event of power failure active doors maybe opened manually.

Microprocessor Controls: Monitors doorway holding beams, door position, electric lock position, activators, motor temperature, and condition of power.

Self-Diagnostics: Checks performed on continuous basis, faults displayed by flashing LED's and buzzer noise on control panels.

Doorway Holding Beams:

Factory installed at 24 inches (610 mm) and 48 inches (1219 mm) from finished floor.

When the beam is interrupted, an open door shall be inhibited from closing.

** NOTE TO SPECIFIER ** Delete options for switches not required.

Switches: As scheduled and indicated on Drawings

Switches: 10 position switch. (10PS)

Switches: 10 position switch with key. (10PK)

Switches: 3 position switch. (3PS)

Switches: 3 position switch with key. (3PK)

Switches: 4 position switch. (4PS)

Switches: 4 position switch with key. (4PK)

Operation:

Motion Detection: Actuated by motion detector mounted on each side of door detection of traffic in each direction.

Reverse Function:

Upon obstruction with Safety Search Circuitry.

Doors shall recycle open if an object is encountered during closing cycle.

Circuitry shall time-out for 5 seconds then search for that object at 50 percent speed on next closing cycle.

If an obstruction is encountered again, doors will recycle open.

Doors shall keep timing-out and recycling at 50 percent speed until obstruction is cleared.

If an object is encountered while opening, the doors will stop, reverse direction one inch, time-out for 5 seconds and close at 50 percent speed.

The next opening the circuitry shall search for that object at 50 percent speed.

If an obstruction is encountered again the doors shall stop reverse direction one inch, time out and close.

The doors shall continue recycling at 50 percent until the object is cleared.

Door Motion Adjustments: Control digital interface provides means to make the following door adjustments; open high speed, open low speed, open braking force, close high speed, close low speed, close braking force, opening time.

Nylon Sweeps:

On bottom of sliding doors.

Double pile weatherstripping for sliding door lead edges.

Single pile weatherstripping between carrier and header on lead stiles of sidelights and pivot stiles of sliding doors.

** NOTE TO SPECIFIER ** Hospitals and medical facilities have specialized needs for their interior manual sliding doors. We continue to address these needs by developing our systems as they are needed. These doors come in design details such as Mini-Blind and Opaque glass for privacy, light control and hygiene. Larger openings for moving beds and equipment are also now possible with telescoping door system. Delete if not required.

INTENSIVE CARE UNIT MANUAL SLIDING DOOR SYSTEM (IC-18)

Intensive Care Unit Manual Sliding Door System: Model IC-18 ICU Manual Slide as manufactured by DITEC Entrematic North America.

Components: Provide door operating system, safety devices, accessories and fasteners as required for complete installation and as scheduled and indicated on Drawings.

System Design: Header components are factory engineered, assembled, adjusted and tested.

Operating Temperature Range: Between -30 degrees F and 130 degrees F (-34 degrees C to 54 degrees C).

** NOTE TO SPECIFIER ** Insert finish designations in blanks below as applicable or insert ' As scheduled and indicated on Drawings.' Delete options for finishes not required.

Aluminum Extrusion Finish: As scheduled and indicated on Drawings.

Aluminum Extrusion Finish: Standard, clear anodized.

Aluminum Extrusion Finish: Standard, bronze anodized.

Aluminum Extrusion Finish: Standard, light bronze anodized.

Aluminum Extrusion Finish: Special anodized, color ___________.

Aluminum Extrusion Finish: Painted, color ___________.

Aluminum Extrusion Finish: Clad, ___________.

Door Panels and Sidelights: Sized to prevent pinch points at meeting stiles.

Compliance: Allow "breakout" to full open position to provide instant egress at any point in door's movement.

Sliding Aluminum Doors: Narrow or medium stile through bolted units, to dimensions and with glazing as scheduled and indicated on Drawings and order confirmation.

** NOTE TO SPECIFIER ** Delete options for door panels not required.

Door Panels: As scheduled and indicated on Drawings.

Door Panels: Basic package, 2 panels.

Door Panels: Basic package, 3 panels.

Door Panels: Basic package, 4 panels.

Door Panels: Telescoping package, 3 panels.

Door Panels: Telescoping package, 6 panels.

Door Panels: Custom engineered door packages as indicated on Drawings.

** NOTE TO SPECIFIER ** Delete options for glass thickness not required.

Door Glass Thickness: As scheduled and indicated on Drawings.

Door Glass Thickness: Stops for 1/4 inch (6 mm) glazing.

Door Glass Thickness: Stops for 5/8 inch (16 mm) glazing.

Aluminum Sidelights: Narrow or medium stile through bolted units, to dimensions and with glazing as scheduled and indicated on Drawings and order confirmation; with intermediate rails.

** NOTE TO SPECIFIER ** Delete options for glass thickness not required.

Sidelight Glass Thickness: As scheduled and indicated on Drawings.

Sidelight Glass Thickness: Stops for 1/4 inch (6 mm) glazing.

Sidelight Glass Thickness: Stops for 5/8 inch (16 mm) glazing.

Aluminum Frames and Extrusions:

** NOTE TO SPECIFIER ** Delete option for dimensions not required.

Dimensions: As scheduled and indicated on Drawings.

Dimensions: Basic package, 4-1/2 inches (114 mm) deep x 1-3/4 inches wide (44 mm) section. with basic package.

Dimensions: Telescoping package, 6 inches (152 mm) deep x 1-3/4 inches wide (44 mm) section.

** NOTE TO SPECIFIER ** Delete option for transoms not required.

Transom Package: None.

Transom Package: As scheduled and indicated on Drawings.

Transom Package: One vertical transom tube, designed for 1/4 inch (6 mm) glazing.

Transom Package: One vertical transom tube, designed for 1 inch (24 mm) glazing.

Header Cases: Encompass the door track and anti-riser guide.

Materials: Extruded aluminum.

Size: 4-1/2 inches wide x 3-5/8 inches high (114 mm x 92 mm).

Header Cover: With a continuous self-locking hinge, opens flush with top of header.

Door Hanger Wheels:

Wheel Materials: Nylon.

Diameter: 2-1/2 inch (64 mm).

Bearings: Stainless steel lifetime lubricated ball bearings.

Anti Riser Wheels: 2 inch (51 mm) anti-riser wheels and supported by a factory adjusted cantilever support and pivot assembly.

Adjustability: Door height and anti-rise adjustments shall be fully accessible with hinge cover in "open" position, field adjustable.

Static Electric Grounding: Provide doors with static electric grounding.

Architectural Hardware and Accessories: Provide stops in header to limit door slide travel.

** NOTE TO SPECIFIER ** Delete option for handles not required.

Handles: As scheduled and indicated on Drawings.

Handles: Standard, recessed door pulls.

Handles: Provide optional surface mounted "D" shaped pull handles.

Handles: Positive latching handles are also optional.

** NOTE TO SPECIFIER ** Delete option for handles not required.

Handle Finish: As scheduled and indicated on Drawings.

Handle Finish: Silver painted finish.

Handle Finish: Flat painted finish.

Weatherstripping: Double vinyl weather stripping on lead stile of the sliding doors and pivot stile of sidelights.

** NOTE TO SPECIFIER ** Delete floor track type not required.

Floor Track Type: As scheduled and indicated on Drawings .

Floor Track Type: None, trackless (SX), pivot assemblies for trackless panel applications shall allow the sliding panels to swing outward for emergency egress without the need of a lower pivot support.

Floor Track Type: Provide floor track to guide sliding door.

Materials: Aluminum.

** NOTE TO SPECIFIER ** Surface applied track can either be full length or only below sidelights, leaving a clear floor in entrance. Delete options for profiles not required.

Profiles: As scheduled and indicated on Drawings .

Profiles: Recess mounted.

Profiles: Surface mounted double bevel.

Profiles: Surface mounted combination bevel/square; options are field adjustable by snap-off beveled edge.

** NOTE TO SPECIFIER ** Delete if not required.** NOTE TO SPECIFIER ** These doors are actually a two door system in one door. They fold or swing open just as it says. The bi-folding-swing door systems are great for small spaces as it reduces rough opening width without sacrificing clear opening space. Delete if not required.

ICU MANUAL FOLD-SWING DOOR SYSTEM (FS-IC)

Intensive Care Unit Manual Fold-Swing Door Systems: Model FS-IC as manufactured by DITEC Entrematic North America.

Components: Provide door operating system, safety devices, accessories and fasteners as required for complete installation and as scheduled and indicated on Drawings.

System Design: Components in the header factory engineered, assembled, adjusted and tested.

Operating Temperature Range: Between -30 degrees F and 130 degrees F (-34 degrees C to 54 degrees C).

** NOTE TO SPECIFIER ** Insert finish designations in blanks below as applicable or insert ' As scheduled and indicated on Drawings.' Delete options for finishes not required.

Aluminum Extrusion Finish: As scheduled and indicated on Drawings.

Aluminum Extrusion Finish: Standard, clear anodized.

Aluminum Extrusion Finish: Standard, bronze anodized.

Aluminum Extrusion Finish: Standard, light bronze anodized.

Aluminum Extrusion Finish: Special anodized, color ___________.

Aluminum Extrusion Finish: Painted, color ___________.

Aluminum Extrusion Finish: Clad, ___________.

Fold-Swing Aluminum Doors: Through bolted door units, narrow or medium stile, to dimensions and with intermediate rails as scheduled and indicated on Drawings.

** NOTE TO SPECIFIER ** Delete options for glass thickness not required.

Door Glass Thickness: As scheduled and indicated on Drawings.

Door Glass Thickness: Stops for 1/4 inch (6 mm) glazing, with transoms.

Door Glass Thickness: Stops for 5/8 inch (16 mm) glazing.

** NOTE TO SPECIFIER ** Delete options for glass thickness not required.

Size: As scheduled and indicated on Drawings.

Size: 36 inches (914 mm).

Size: 42 inches (1067 mm).

Door Configuration: Shall be either the 2 leaf fold-1 leaf swing basic door package or the 4 leaf bifolding (no swing) door package.

Aluminum Frames and Extrusions:

Integral Structural Sections: Minimum .125 inch (3 mm) thickness.

Dimensions: 4-1/2 inches (114 mm) deep x 1-3/4 inches wide (44 mm) section.

Header Cases: Encompass folding door track and swing door concealed closer device, with removable plate which provides access to pivot components.

Materials: Extruded aluminum.

Size: 4-1/2 inches wide x 2 inches high (114 mm x 51 mm).

Pivot Assemblies: Adjustable pivot assemblies shall allow the door panels to fold-swing open for emergency ingress/egress without the need of breakaway devices.

** NOTE TO SPECIFIER ** Delete if not required.

Static Electric Grounding, Provide doors with optional static electric grounding.

Hardware and Accessories:

** NOTE TO SPECIFIER ** Delete option for handles not required.

Handles: Standard, surface mounted "D" shaped pull handles; pull bars span lead fold panels.

** NOTE TO SPECIFIER ** Delete option for handles not required.

Handle Finish: As scheduled and indicated on Drawings.

Handle Finish: Silver painted finish.

Handle Finish: Flat painted finish.

Fold Door Guide: 1 inch (25 mm) delrin; free floating through travel of door.

Weatherstripping: Lead and pivot stile of the fold-swing doors shall be provided with double brushpile or vinyl weather stripping.

Floor Track Type: None, trackless.

Operation:

Folding leaves shall remain at full open position until manually closed.

Swing door shall return to closed position automatically by concealed double acting door closer unless opened to (90 degree) full open maintained position.

Swing door manually moved from full open position towards closure shall continue to closed position automatically.

** NOTE TO SPECIFIER ** Delete if not required.

HARDWARE AND ACCESSORlES

Activation and Safety Devices:

** NOTE TO SPECIFIER ** For added convenience and accessibility, Hunter push button controls are available with large, easy to-activate push plates. Hard wired or radio controlled push plates are available in a wide variety of finishes, sizes, profiles and logo choices. Switches may also be mounted to posts and rails for maximum convenience and accessibility. Delete if not required.

Push Plates: Standard.

** NOTE TO SPECIFIER ** The new Low Profile 36 inch (914 mm) Push Plate for automatic doors maximizes mobility and independence for people with disabilities. The entire surface is activation ready with four separate, and redundant, switches that allow activation from virtually any angle. Designed with a 36 inch (914 mm) x 6 inch (152 mm) activation zone and low profile depth of 1 inch (25 mm). Can be mounted to any flat surface in a few easy steps. Easily adapts to either a wireless or hard wired installation. Built-in wireless transmitter comes pre-installed in the top end cap. Delete if not required.

Push Plates: BEA Push Plates.

** NOTE TO SPECIFIER ** For areas requiring longer-range signaling, Hunter digital radio equipment provides reliable activation from up to 80 feet away. Matching wavelength receivers permit distinction between multiple doors, and security settings can be changed in minutes. Optional two- and four-button transmitters offer even greater versatility. Hunter's new manual semi automatic door is unique, simple innovation for sliding door operation. Delete if not required

Semi Automatic Sliding Door Systems: HSC Remote Control System.

Semi Automatic Sliding Door Systems: HCA Remote Control System.

** NOTE TO SPECIFIER ** These sensors are for fully automatic door opening control. They can be used for swinging, sliding and folding doors.

Microwave Sensors: BEA.

Microwave Sensors: Optex.

** NOTE TO SPECIFIER ** In order to find the right door type which is the best possible fit with the requirements of both users and operators, it is advisable not only to consider aesthetic requirements but also some other important aspects at an early stage. Much attention should be paid to personal safety.

Safety Sensors: BEA.

Safety Sensors: Optex.

** NOTE TO SPECIFIER ** Delete if not required.

Locking Systems: As scheduled and indicated on Drawings.

** NOTE TO SPECIFIER ** Delete if not required.

Locking Systems: Trident 4 point lock, 4-point deadbolt exit lock (3 moving, fixed hinge-side bolt); depressing paddle retracts deadbolts for one-motion exiting.

** NOTE TO SPECIFIER ** Delete if not required.

Locking Systems: TEL-100, locked by pulling paddle when door is in closed position.

** NOTE TO SPECIFIER ** Delete if not required.

Locking Systems: TEL-200 models provide identical deadbolt protection, with self re-locking each time door is closed; pull handle is not furnished, door closer is required for self-locking.

EXECUTION

EXAMINATION AND PREPARATION

Prepare substrates using the methods recommended by the manufacturer for achieving best result for the substrates under project conditions.

Field verify as-built conditions and verify the manufacturer's details for accuracy to fit the wall assembly prior to fabrication.

Do not proceed with installation until substrates have been prepared using the methods recommended by the manufacturer and deviations from manufacturer's recommended tolerances are corrected. Commencement of installation constitutes acceptance of conditions.

If preparation is the responsibility of another installer, notify Architect in writing of deviations from manufacturer's recommended installation tolerances and conditions.

INSTALLATION

Install in accordance with manufacturer's instructions. Set units in proper relationship with adjacent work. Test for proper operation and adjust until satisfactory results are obtained

** NOTE TO SPECIFIER ** Delete options for compliance not required.

Installation shall be approved by an AAADM certified inspector.

Conform to UL Standard 325 and ANSI-BHMA Standard A156.10

Conform to UL Standard 325 and ANSI-BHMA Standard A156.19.

Explain and review the Daily Safety Check Procedure.

PROTECTION

Protect installed products until completion of project.

Touch-up, repair or replace damaged products before Substantial Completion.

END OF SECTION ................
................