GLEON-SA1C-735-U-T4W
Signify Classified - Internal #
Cooper Lighting Solutions Photometric Lab 1121 Highway 74 South Peachtree City, GA 30269
Scaled data based on original data using LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-
State Lighting Products
Test Report Prepared for Cooper Lighting Solutions
(formerly Eaton) Brand: McGRAW-EDISON Report Number: P382793 Luminaire Tested: GLEON-SA1C-735-U-T4W
Issue Date: 3/3/2020
Report Generated By E0585644
1 of 8
Signify Classified - Internal #
Cooper Lighting Solutions Photometric Lab 1121 Highway 74 South Peachtree City, GA 30269
Scaled Data Report
Test Information Test Method: LM-79-08
Report Number: P382793 TEST IS SCALED FROM IESNA LM-79-08 TEST DATA (G2-1903-205-18)
Test Lab: INNOVATION CENTER Issue Date: 3/3/2020 Manufacturer: COOPER LIGHTING SOLUTIONS (FORMERLY EATON) Product Line: McGRAW-EDISON Catalog Number: GLEON-SA1C-735-U-T4W Description: GALLEON AREA AND ROADWAY LUMINAIRE
(1) 70 CRI, 3500K, 1050mA LIGHTSQUARE WITH 16 LEDS AND TYPE IV WIDE OPTICS Light Source: Ballast/Driver: ELECTRONIC DRIVER
Summary Lumens per Lamp: N/A Luminaire Lumens: 6850.6 lumens
Efficiency: N/A Efficacy: 116.1 lumens/watt
Luminous Opening: Rectangular (W 0.5' x L: 0.5' x H: 0') IES Classification: Type IV - Short BUG Rating: B1 - U0 - G2
Input Watts (W): 59 Input Voltage (V): NR Input Current (Ain): NR
Voltage Rise (V): NR Power Factor: NR
Total Harmonic Distortion (THDi): NR Frequency (hertz): 60 Stabilization Time: NR Operation Time: NR
Ambient Temperature (?C): NR Test Distance: 24 FT
FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE
2 of 8
Signify Classified - Internal #
Cooper Lighting Solutions Photometric Lab 1121 Highway 74 South Peachtree City, GA 30269
Scaled Data Report
REPORT NUMBER: P382793 CATALOG NUMBER: GLEON-SA1C-735-U-T4W
Transverse Distance in Units of Mounting Height
Iso-Footcandle Lines of Horizontal Illumination
-2
Max cd 1/2 Max cd
-1
0 1
1
1.75 2
2.75 3
4 0
0.5 0.2 0.1
Short
Medium
Long
1
2 2.25
3
3.75 4
5
Longitudinal Distance in Units of Mounting Height
Based on 25 foot mounting height. Maximum calculated value = 1.4 fc Type IV - Short - N/A
House Side Street Side
Type I Type II
Type III
Type IV
6
7
FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE
3 of 8
Signify Classified - Internal #
Cooper Lighting Solutions Photometric Lab 1121 Highway 74 South Peachtree City, GA 30269
Scaled Data Report
REPORT NUMBER: P382793 CATALOG NUMBER: GLEON-SA1C-735-U-T4W
Luminous Intensity Polar Plot
180? 4,597 cd
170? 160? 150?
3,448 cd
140? 130?
2,299 cd
120?
1,149 cd
110? 100?
0 cd
90?
80?
70?
60?
50? 40? 30? 20? 10? 0?
Vertical Plane Through 46-Deg Lateral
Horizontal Cone Through 70-Deg Vertical
FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE
4 of 8
Signify Classified - Internal #
Cooper Lighting Solutions Photometric Lab 1121 Highway 74 South Peachtree City, GA 30269
Scaled Data Report
REPORT NUMBER: P382793 CATALOG NUMBER: GLEON-SA1C-735-U-T4W
FLUX DISTRIBUTION:
House Side Street Side Total
Lumens % Fixture Lumens % Fixture Lumens % Fixture
Downward 1570.1 22.9 5280.5 77.1 6850.6 100.0
Upward 0.0 0.0 0.0 0.0 0.0 0.0
Total 1570.1
22.9 5280.5
77.1 6850.6
100.0
ZONAL LUMENS:
Zone
Lumens
0?-10?
71.1
10?-20?
237.0
20?-30?
395.3
30?-40?
560.9
40?-50?
825.0
50?-60?
1397.2
60?-70?
1983.3
70?-80?
1204.9
80?-90?
175.8
90?-100?
0.0
100?-110?
0.0
110?-120?
0.0
120?-130?
0.0
130?-140?
0.0
140?-150?
0.0
150?-160?
0.0
160?-170?
0.0
170?-180?
0.0
0?-90?
6850.6
0?-180?
6850.6
% Fixture 1.0 3.5 5.8 8.2
12.0 20.4 29.0 17.6
2.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 100.0 100.0
Coefficient of Utilization
0.9
0.8
76.7%
0.7
0.6
0.5
0.4
0.3
0.2
22.2%
0.1
0
0
1
2
3
4
5
Street Width in Units of Mounting Height
HS
SS
FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE
5 of 8
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- chem 1c midterm 2
- jlv 3 1 0 0 0 user guide veterans affairs
- high pressure stainless steel parker hannifin
- 6 8 5 7 6 1 1 2 0 0 66 2 1 8 1 7 67 7 6
- 2 pcb terminal blocks 1 5 mm awg 16 pin spacings 5 mm 0 197 in and 3 81
- 735 nautilus
- operating instructions tico 735 dc process
- 0 1 23 4 5 6 735 899 university of minnesota
- game summary rus fin 6 2 2 1 2 0 2 1
- disinfectant liquid rm 735