Acuvue Tech Specs 2020 EN - Johnson & Johnson Vision | ACUVUE
[Pages:2]2020
UPDATE
TECHNICAL SPECIFICATIONS
Recommended Replacement
Wearing Schedule
Pack Size
Proprietary Technology
Lens Material
Dk/t Value1
(edge corrected)
Water Content
Visibility Tint
Approximate UV
Blocking* INDUSTRY LEADING *
I/O Mark
Orientation Mark
Centre Thickness
(mm @ -3.00D)
Parameters BC (mm) / Dia (mm)
Power Range (D)
Customer Service Toll Free 1-800-267-5098
Fax 1-800-267-2259
Email jjvisioncare@its.
Internet Ordering and Website jnjvisionpro.ca
ACUVUE? OASYS 1-Day
Daily Disposable Daily Wear 90 Pack HydraLuxe? senofilcon A 121 x 10-9 38%
ACUVUE? OASYS 1-Day for
ASTIGMATISM
Daily Disposable
Daily Wear 30 Pack
HydraLuxe? senofilcon A
129 x 10-9
38%
1-DAY ACUVUE? TruEye?
Daily Disposable Daily Wear
30 and 90 Packs HYDRACLEAR? 1
narafilcon A 118 x 10-9 46%
1-DAY ACUVUE? MOIST
Daily Disposable Daily Wear
30 and 90 Packs LACREON? etafilcon A 25.5 x 10-9 58%
1-DAY ACUVUE? MOIST for
ASTIGMATISM Daily Disposable
Daily Wear 30 and 90 Packs
LACREON? etafilcon A 23.8 x 10-9
58%
1-DAY ACUVUE? MOIST MULTIFOCAL
Daily Disposable Daily Wear
30 and 90 Packs LACREON? etafilcon A 25.5 x 10-9 58%
Blocks >99.9% of UVB & ~96.1% of UVA
No
0.085
8.5/14.3
-0.50D to -12.00D +0.50D to +8.00D
(in 0.50D steps above ?6.00D)
9.0/14.3
-0.50D to -12.00D +0.50D to +8.00D
(in 0.50D steps above ?6.00D)
Blocks >99.9% of UVB & ~96.1% of UVA
No
Vertical
0.080
8.5/14.3
Plano to -6.00D (in 0.25D steps) Cyl: -0.75, -1.25, -1.75
Axis: 10? to 180? (in 10? increments) Cyl: -2.25
Axis: 10?, 20?, 70?, 80?, 90?, 100?, 110?, 160?, 170?, 180?
-6.50D to -9.00D (in 0.50D steps) Cyl: -0.75, -1.25, -1.75
Axis: 10?, 20?, 70?, 80?, 90?, 100?, 110?, 160?, 170?, 180?
+0.25D to +4.00D (in 0.25D steps) Cyl: -0.75, -1.25, -1.75
Axis: 10?, 20?, 70?, 80?, 90?, 100?, 110?, 160?, 170?, 180?
Blocks >99.9% of UVB & ~96.9% of UVA
No
0.085
8.5/14.2
-0.50D to -12.00D +0.50D to +6.00D
(in 0.50D steps above -6.00D)
9.0/14.2
-0.50D to -12.00D +0.50D to +6.00D
(in 0.50D steps above -6.00D)
Blocks ~97% of UVB & 82% of UVA
No 0.084 8.5/14.2
-0.50D to -12.00D +0.50D to +6.00D
(in 0.50D steps above -6.00D)
9.0/14.2
-0.50D to -12.00D +0.50D to +6.00D
(in 0.50D steps above -6.00D)
1-DAY ACUVUE? DEFINE? Find details at jnjvisionpro.ca
Blocks ~97% of UVB & 82% of UVA
No
Vertical
0.090
8.5/14.5
Plano to -6.00D (in 0.25D steps) Cyl: -0.75, -1.25, -1.75
Axis: 10? to 180? (in 10? increments) Cyl: -2.25
Axis: 10?, 20?, 70?, 80?, 90?, 100?, 110?, 160?, 170?, 180?
-6.50D to -9.00D (in 0.50D steps) Cyl: -0.75, -1.25, -1.75
Axis: 10?, 20?, 70?, 80?, 90?, 100?, 110?, 160?, 170?, 180?
+0.25D to +4.00D (in 0.25D steps) Only available in 30 Packs
Cyl: -0.75, -1.25, -1.75 Axis: 10?, 20?, 70?, 80?, 90?, 100?, 110?, 160?, 170?, 180?
Blocks ~97% of UVB & 82% of UVA
No
0.084
8.4/14.3
+6.00D to -9.00D
(in 0.25D steps)
ADDS: LOW: +0.75D to +1.25D MID: +1.50D to +1.75D HIGH: +2.00D to +2.50D
1. Oxygen transmissibility measured via polarographic method at centre -3.00D lens using boundary corrected, edge corrected Dk value. Units (cm/sec) (ml O2/ml x mm Hg) at 35? C.
Important Safety Information: ACUVUE? Contact Lenses are indicated for vision correction. ACUVUE? OASYS Contact Lenses are indicated for vision correction and for use as a therapeutic lens. ACUVUE? VITA Contact Lenses are indicated for vision correction as a daily wear lens with one-month recommended replacement. As with any contact lens, eye problems, including corneal ulcers, can develop. Some wearers may experience mild irritation, itching or discomfort. Lenses should not be prescribed if patients have any eye infection, or experience eye discomfort, excessive tearing, vision changes, redness or other eye problems. For refractive ametropia use, lenses should not be prescribed if patients have an eye infection or experience eye discomfort, excessive tearing, vision changes, redness or other eye problems. Consult the package insert for complete information. Complete information is also available from Johnson & Johnson Vision Care division of Johnson & Johnson Inc., by calling 1-800-267-5098 or by visiting jnjvisionpro.ca.
2020
UPDATE
NEW SIZE!
TECHNICAL SPECIFICATIONS
Recommended Replacement
Wearing Schedule
Pack Size Proprietary Technology
Lens Material
Dk/t Value1
(edge corrected)
Water Content
Visibility Tint
Approximate UV
Blocking* INDUSTRY LEADING
*
I/O Mark
Orientation Mark
Centre Thickness
(mm @ -3.00D)
Parameters BC (mm) / Dia (mm)
Power Range (D)
ACUVUE? VITA
1 Month DW
Daily Wear 6 and 12 Packs
HydraMax?
senofilcon C 147 x 10-9
41%
Blocks 99.8% of UVB & 93.4% of UVA
No 0.070 8.4/14.0
-0.50D to -12.00D +0.50D to +8.00D
(in 0.50D steps above ?6.00D)
8.8/14.0
-0.50D to -12.00D +0.50D to +8.00D
(in 0.50D steps above ?6.00D)
ACUVUE? VITA for ASTIGMATISM
ACUVUE? OASYS with TransitionsTM
ACUVUE? OASYS
1 Month DW Daily Wear
6 Pack HydraMax? senofilcon C 129 x 10-9
2 Weeks DW Daily Wear
1 Week EW or 2 Weeks DW
Extended Wear Daily Wear
6 and 25 Packs
TransitionsTM Light Intelligent TechnologyTM
12 and 24 Packs HYDRACLEAR? PLUS
senofilcon A
senofilcon A
121 x 10-9
147 x 10-9
41%
38%
38%
ACUVUE? OASYS for ASTIGMATISM
1 Week EW or 2 Weeks DW Extended Wear Daily Wear
6 Pack
HYDRACLEAR? PLUS
senofilcon A
129 x 10-9
38%
ACUVUE? OASYS for PRESBYOPIA
1 Week EW or 2 Weeks DW Extended Wear Daily Wear
6 Pack
HYDRACLEAR? PLUS
senofilcon A
147 x 10-9
38%
Blocks 99.8% of UVB & 93.4% of UVA
No
Vertical
0.080
8.6/14.5
Plano to -6.00D (in 0.25D steps) Cyl: -0.75, -1.25, -1.75, -2.25** Axis: 10? to 180? (in 10? increments) **Axis: 10?, 20?, 70?, 80?, 90?, 100?, 110?, 160?, 170?, 180?
-6.50D to -9.00D (in 0.50D steps) Cyl: -0.75, -1.25, -1.75
Axis: 10?, 20?, 70?, 80?, 90?, 100?, 110?, 160?, 170?, 180?
+0.25D to +4.00D (in 0.25D steps) Cyl: -0.75, -1.25, -1.75
Axis: 10?, 20?, 70?, 80?, 90?, 100?, 110?, 160?, 170?, 180?
Blocks 100% of UVB & >99% of UVA
No
0.085
8.4/14.0
Plano -0.25D to -12.00D +0.25D to +8.00D
(in 0.50D steps above ?6.00D)
8.8/14.0
8.8 BC Revenue Only Plano
-0.25D to -12.00D +0.25D to +8.00D
(in 0.50D steps above ?6.00D)
Blocks >99.9% of UVB & ~96.1% of UVA
Blocks >99.9% of UVB & ~96.1% of UVA
No
No
Vertical
0.070
8.4/14.0
Plano (6 pack only) -0.50D to -12.00D +0.50D to +8.00D
(in 0.50D steps above ?6.00D)
8.8/14.0
Plano (6 pack only) -0.50D to -12.00D +0.50D to +8.00D
(in 0.50D steps above ?6.00D)
0.080
8.6/14.5
Plano to -6.00D (in 0.25D steps) Cyl: -0.75, -1.25, -1.75, -2.25, -2.75 Axis: 10? to 180? (in 10? increments)
-6.50D to -9.00D (in 0.50D steps) Cyl: -0.75, -1.25, -1.75, -2.25, -2.75 Axis: 10? to 180? (in 10? increments)
+0.25D to +6.00D (in 0.25D steps) Cyl: -0.75, -1.25, -1.75, -2.25, -2.75
Axis: 10? to 180? (in 10? increments)
Blocks >99.9% of UVB & ~96.1% of UVA
No
No
0.070
8.4/14.3
+6.00D to -9.00D
(in 0.25D steps)
ADDS: LOW: +0.75D to +1.25D MID: +1.50D to +1.75D HIGH: +2.00D to +2.50D
Important Safety Information: ACUVUETM RevitaLens Multi-Purpose Disinfecting Solution (MPDS) is indicated for the care of soft (hydrophilic) contact lenses, including silicone hydrogel lenses. Use this product, as recommended by your eye care professional, to disinfect, clean, rinse, store, remove protein and condition your lenses. If you are allergic to any ingredient in ACUVUETM RevitaLens MPDS do not use this product. Problems with contact lenses and lens care products could result in corneal infection and/or ulcers and lead to loss of vision. It is essential that you follow your eye care professional's directions and all labeling instructions for proper use of lenses and lens care products, including the lens case.
*Helps protect against transmission of harmful UV radiation to the cornea and into the eye. WARNING: UV-absorbing contact lenses are NOT substitutes for protective UV-absorbing eyewear such as UV-absorbing goggles or sunglasses because they do not completely cover the eye and surrounding area. You should continue to use UV-absorbing eyewear as directed. NOTE: Long-term exposure to UV radiation is one of the risk factors associated with cataracts. Exposure is based on a number of factors such as environmental conditions (altitude, geography, cloud cover) and personal factors (extent and nature of outdoor activities). UV-blocking contact lenses help provide protection against harmful UV radiation. However, clinical studies have not been done to demonstrate that wearing UV-blocking contact lenses reduces the risk of developing cataracts or other eye disorders.
Transitions, the Transitions logo and Transitions Light Intelligent Technology are trademarks of Transitions Optical, Inc. used under license by Transitions Optical Limited and Johnson & Johnson Vision Care, Inc. ? 2020 Johnson & Johnson Vision Care division of Johnson & Johnson Inc. PP2020MLT6700 June 2020
Great Match with Leading Soft
Contact Lenses
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- acuvue brand contact lenses
- acuvue oasys with transitions light intelligent
- subjective and objective measures of the use of acuvue
- instructions for use en daily wear frequent replacement
- acu solace product catalog nyuko ol 0913
- johnson johnson vision care inc clinical study protocol
- patient instruction guide acuvue contact lenses
- patients frequently asked questions about acuvue oasys
- up to satisfaction guaranteed or your money back
- the contact lens that knows light
Related searches
- johnson controls tech support number
- johnson and johnson hr department
- acuvue oasys 1 day
- acuvue oasys transitions
- acuvue oasys for astigmatism
- johnson johnson human resources department
- icd 705 tech specs 1 5
- johnson controls hvac tech support
- johnson and johnson email address
- johnson and johnson hr
- microsoft flight simulator 2020 tech support
- vision 2020 conference registration