Certificate of Accreditation - Airborne Labs

PERRY JOHNSON LABORATORY ACCREDITATION, INC.

Certificate of Accreditation

Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of:

Airborne Labs International Inc.

22C World's Fair Drive, Somerset, NJ 08873

(Hereinafter called the Organization) and hereby declares that Organization is accredited in accordance with the recognized International Standard:

ISO/IEC 17025:2005

This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system

(as outlined by the joint ISO-ILAC-IAF Communiqu? dated April 2017):

Chemical Testing

(As detailed in the supplement)

Accreditation claims for such testing and/or calibration services shall only be made from addresses referenced within this certificate. This Accreditation is granted subject to the system rules governing the Accreditation referred to above, and the Organization hereby covenants with the Accreditation body's duty to observe and comply with the said rules.

For PJLA:

Tracy Szerszen President/Operations Manager Perry Johnson Laboratory Accreditation, Inc. (PJLA) 755 W. Big Beaver, Suite 1325 Troy, Michigan 48084

Initial Accreditation Date: October 7, 2010

Issue Date: November 15, 2018

Expiration Date: February 28, 2021

Accreditation No.: 68099

Certificate No: L18-537

The validity of this certificate is maintained through ongoing assessments based on a continuous accreditation cycle. The validity of this certificate should be confirmed through the PJLA website:

Page 1 of 4

Certificate of Accreditation: Supplement

Airborne Labs International, Inc.

22C World's Fair Drive, Somerset, NJ 08873 Contact Name: Nicole James Phone: 732-302-1950

Accreditation is granted to the facility to perform the following testing:

FIELD OF TEST

ChemicalF

ITEMS, MATERIALS OR

PRODUCTS TESTED

Carbon Dioxide

SPECIFIC TESTS OR PROPERTIES MEASURED

SPECIFICATION, STANDARD METHOD OR

TECHNIQUE USED

Assay Concentration

ISBT 2.0 Caustic absorption Zahm-Nagel ISBT 3.0 Conductimetric Hygrometer ISBT 5.0 Detector Tube (DT) (Colorimetric) ISBT 6.0 Detector Tube (DT) (Colorimetric) ISBT 7.0 Detector Tube (DT) (Colorimetric) ISBT 7.1 Detector Tube (DT) (Colorimetric) ISBT 8.0 Gravimetric

ISBT SM 3.0 Detector Tube (DT) (Colorimetric) ISBT 10.0 THA (FID)

Concentration, Various Compounds

ISBT 4.0

ISBT 10.1 GC/FID

ISBT 9.0 and 11.0 GC/FID

ISBT 12.0 GC/FID

ISBT 14.0 GC/SCD

RANGE (WHERE APPROPRIATE) AND DETECTION LIMIT

99.00 % to 99.99 % Graduation 0.01 %

1 ?L/L to 5 000 ?L/L (ppm by volume) D. L. = 0.5 ?L/L 5 ?L/L to 100 ?L/L (ppm by volume) D. L. = 1 ?L/L 0.2 ?L/L to 4 ?L/L (ppm by volume) D. L. = 0.1 ?L/L 0.2 ?L/L to 5 ?L/L (ppm by volume) D. L. = 0.1 ?L/L 0.5 ?L/L to 30 ?L/L (ppm by volume) D. L. = 0.1 ?L/L 2 mg/kg to 20 mg/kg (ppm by weight) D. L. = 2 mg/kg 0.1 ?L/L to 1.5 ?L/L (ppm by volume) D. L. = 0.1 ?L/L 1 ?L/L to 10 000 ?L/L (ppm by volume) D. L. = 0.1 ?L/L Concentration, Various Compounds 0.1 ?L/L to 1 000 ?L/L (ppm by volume) D. L. = 0.1 ?L/L 0.1 ?L/L to 100 ?L/L (ppm by volume) D. L. = 0.1 ?L/L 5 nL/L to 100 nL/L (ppb by volume) D. L. = 1 nL/L 0.01 ?L/L to 50 ?L/L (ppm by volume) D. L. = 0.01 ?L/L

Issue: 11/2018

This supplement is in conjunction with certificate #L18-537

Page 2 of 4

Certificate of Accreditation: Supplement

Airborne Labs International, Inc.

22C World's Fair Drive, Somerset, NJ 08873 Contact Name: Nicole James Phone: 732-302-1950

Accreditation is granted to the facility to perform the following testing:

FIELD OF TEST

ChemicalF

ITEMS, MATERIALS OR

PRODUCTS TESTED

Carbon Dioxide

SPECIFIC TESTS OR PROPERTIES MEASURED

SPECIFICATION, STANDARD METHOD OR

TECHNIQUE USED

Concentration Various Compounds

Soft Ionization Spectrometer (SIS)

Gas Chromatography

Gases

Appearance, Odor, and Taste Identification Concentration of Impurities

ISBT 15.0 to 16.0 Sensory FTIR

GC

Conductimetric Hygrometry

Oxygen Analyzer

Detector Tube (DT) (Colorimetric)

Sulfur Hexafluoride Hydrogen Fuel SAE J2719

ASTM

Water

FTIR

Total Hydrocarbon FTIR or GC/FID

(as CH4)

Oxygen

GC/PDID

Helium

GC/TCD (Helium)

Nitrogen/Argon

GC/PDID

Carbon Dioxide

FTIR

Carbon Monoxide FTIR

RANGE (WHERE APPROPRIATE) AND DETECTION LIMIT

Varies with compound 0.005 ?L/L to 50 ?L/L (ppm by volume) D.L.= 0.005 ?L/L Varies with compound 0.005 ?L/L to 100 ?L/L (ppm by volume) D.L.= 0.002 ?L/L N/A

Varies with compound 0.1 ?L/L to 100 ?L/L (ppm by volume) D. L. = 0.1 ?L/L Varies with compound 0.000 1 % to 100 % D. L. = 0.000 1 % Varies with compound 0.1 ?L/L to 100 ?L/L (ppm by volume) D. L. = 0.1 ?L/L Varies with gas 0.000 1 % to 100 % D. L. = 0.000 1 % Varies with compound 0.2 ?L/L to 2 000 ?L/L (ppm by volume) D. L. = 0.02 ?L/L As per ASTM D2472

1 ?L/L to 50 ?L/L D.L. = 0.5 ?L/L 0.1 ?L/L to 1 000 ?L/L D.L. = 0.1 ?L/L 1 ?L/L to 40 ?L/L D.L. = 1 ?L/L 20 ?L/L to 1 000 ?L/L D.L. = 10 ?L/L 2 ?L/L to 40 ?L/L D.L. = 1 ?L/L 0.1 ?L/L to 10 ?L/L D.L. = 0.05 ?L/L 0.01 ?L/L to 10 ?L/L D.L. = 0.01 ?L/L

Issue: 11/2018

This supplement is in conjunction with certificate #L18-537

Page 3 of 4

Certificate of Accreditation: Supplement

Airborne Labs International, Inc.

22C World's Fair Drive, Somerset, NJ 08873 Contact Name: Nicole James Phone: 732-302-1950

Accreditation is granted to the facility to perform the following testing:

FIELD OF TEST

ChemicalF

ITEMS, MATERIALS OR

PRODUCTS TESTED

Hydrogen Fuel SAE J2719

SPECIFIC TESTS OR PROPERTIES MEASURED

SPECIFICATION, STANDARD METHOD OR

TECHNIQUE USED

Sulfur Compounds (TSC) Formaldehyde

GC/SCD FTIR

Formic Acid

FTIR

Ammonia

FTIR

Total Halogenated Compounds (Organic and Inorganic)

FTIR or GC/MS

RANGE (WHERE APPROPRIATE) AND DETECTION LIMIT

0.002 ?L/L to 20 ?L/L D.L. = 0.001 ?L/L 0.01 ?L/L to 10 ?L/L D.L. = 0.01 ?L/L 0.02 ?L/L to 10 ?L/L D.L. = 0.02 ?L/L 0.02 ?L/L to 10 ?L/L D.L. = 0.01 ?L/L 0.02 ?L/L to 10 ?L/L D.L. = 0.01 ?L/L (Analyte Dependent)

1 The presence of a superscript F means that the laboratory performs testing of the indicated parameter at its fixed location. Example: Outside MicrometerF would mean that the laboratory performs this testing at its fixed

location.

Issue: 11/2018

This supplement is in conjunction with certificate #L18-537

Page 4 of 4

................
................

In order to avoid copyright disputes, this page is only a partial summary.