Www.cmdgroup.com



BRK Brands, Inc.3901 Liberty StreetAurora, IL?60504Phone:?(630) 851-7330;Email:?HYPERLINK "mailto:info%%20?subject=M%3Canu-Spec%20inquiryt"info@Website:?HYPERLINK " " This Manu-Spec? utilizes the Construction Specifications Institute (CSI) Project Resource Manual (PRM), including MasterFormat?, SectionFormat? and PageFormat?. A Manu-Spec is a manufacturer-specific proprietary product specification using the proprietary method of specifying applicable to project specifications and master guide specifications. Optional text is indicated by brackets [ ]; delete optional text in final copy of specification. Specifier Notes precede specification text; delete notes in final copy of specification. Trade/brand names with appropriate product model numbers, styles and types are used in Specifier Notes and in the specification text Article titled “Acceptable Material.” Metric conversion, where used, is soft metric conversion.This Manu-Spec specifies photoelectric and ionization combination smoke and CO sensors for residential and institutional applications, and based upon the BRK Brands, Inc. combination smoke and CO alarm product line.28 46 11.23COMBINATION SENSORSPART 1 GENERAL1.1?SUMMARYA.Section Includes:?Photoelectric and ionization combination smoke and CO sensors for residential: single and multifamily; and institutional applications.Specifier Note:?Revise the Paragraph below to suit the Project requirements. Add section numbers and titles as recommended by CSI MasterFormat and specifiers practice.B.Related Requirements:Specifier Note:?Include in this Paragraph only those sections and documents that directly affect the work of this section. If a reader of this section could reasonably expect to find a product or component specified in this section, but it is actually specified elsewhere, then the related section number(s) should be listed in the Subparagraph below. Do not include Division 00 documents or Division 01 sections since it is assumed that all technical sections are related to all project Division 00 documents and Division 01 sections to some degree. Refer to other documents with caution since referencing them may cause them to be considered part of the Contract.1.Section [___].1.2?REFERENCESSpecifier Note:?Define terms that are unique to this Section and are not provided elsewhere in the contract documents. Include in this Article terms that are unique to the work result specified that may not be commonly known in the construction industry. Delete the following Paragraph if no Definitions are required.A.Definitions:1.[____].Specifier Note:?Paragraph below may be omitted when specifying manufacturer’s proprietary products and recommended installation. Retain References Paragraph when specifying products and installation by an industry reference standard. List retained standard(s) referenced in this section alphabetically. Indicate issuing authority name, acronym, standard designation and title. Establish policy for indicating edition date of standard referenced and update as applicable. Contract Conditions Section 01 42 00 - References may be used to establish the edition date of standards. This Paragraph does not require compliance with standard(s). It is a listing of all references used in this section. Only include here standards that are referenced in the body of the specification in PARTS 1, 2 and/or 3. Do not include references to building codes at any level.B.Reference Standards:1.National Fire Protection Association (NFPA).a.NFPA (Fire) 101 - [2018], Fire Safety Code.b.NFPA (Fire) 70 - [2017], National Electrical Code. c.NFPA (Fire) 72 - [2019], National Fire Alarm and Signaling Code.d.NFPA (Fire) 720 - [2015], Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment.2.Underwriter’s Laboratories (UL).a.UL 217- [2015], Smoke Alarms.b.UL 2034 - [2017], Single and Multiple Station Carbon Monoxide Detectors.3.US Green Building Council (USGBC).a.LEED NC V4-[2019], LEED (Leadership in Energy and Environmental Design):?Green Building Rating System Reference Package For New Construction and Major Renovations. Specifier Note:?Article below includes submittal of relevant data to be furnished by Contractor before, during or after construction. Coordinate this article with [Architect] [Engineer]’s and Contractor’s duties and responsibilities in Contract Conditions and Section 01 33 00 - Submittal Procedures.1.3?ADMINISTRATIVE REQUIREMENTSSpecifier Note:?Retain and edit the following Paragraph to suit Project requirements.A.Coordination:?Coordinate work of this Section with work of other subtrades.B.Pre-installation Meeting:?Convene pre-installation meeting after Award of Contract and one week prior to commencing work of this Section to verify Project requirements, substrate conditions and coordination with other building subtrades, and to review manufacturer’s written recommendations.ply with Section 01 31 19 Project Meetings and coordinate with other similar pre-installation meetings.2.Notify attendees 2 weeks prior to meeting and ensure meeting attendees include as minimum:a.Owner.b.Architect.bination sensor manufacturer’s technical representative.3.Record meeting proceedings including corrective measures and other actions required to ensure successful completion of work and distribute to each attendee within one week of meeting.1.4?SUBMITTALSA.Product Data:?Manufacturer’s standard specifications and descriptive literature, including:1.Physical characteristics.2.Performance criteria.3.Safety Data Sheets.B.Samples:?1.Submit one sample of each type of combination smoke and CO sensors used on Project.a.Samples will be returned to Contractor for incorporation into Work.Specifier Note:?Specify submittals intended to document manufacturer storage, installation and other instructions.C.Manufacturer’s written instructions, including:1.Delivery, storage and handling recommendations.2.Preparation and installation recommendations.D.Test Reports:?Certified test reports showing compliance with specified performance characteristics and physical properties.E.Certificates:?Product certificates signed by manufacturer certifying materials comply with specified performance characteristics and criteria, and physical requirements.F.Manufacturer’s Field Reports:?Submit manufacturer’s field reports within 3 days of each manufacturer representative’s site visit and inspection.G.Electrician’s Qualifications:?Submit copy of certification as journeyman or master electrician.Specifier Note:?Coordinate Article below with Contract Conditions and with Section 01 78 36 - WarrantiesH.Warranty:?Fully executed, issued in [Owner’s] name, and registered with manufacturer.1.Manufacturer’s [1-year] warranty, from date of substantial completion, covering defects in materials.Specifier Note:?Retain and edit the following only if specifying for a LEED project. Specify only the technical submittal requirements necessary to achieve the credits desired for this Project.I.Sustainable Design (LEED) Submittals:1.LEED Submittals:?In accordance with Section [01 35 21 – LEED Requirements].2.Submit verification for items when appropriate as follows:a.Material and Resources:1)MR 5.1 and MR 5.2 - Regional materials.2)[___].b.[___].1.5?CLOSEOUT SUBMITTALSSpecifier Note:?Retain and edit the following Paragraph to meet project requirements. Verify section number and title of Division 01 section which deals with Closeout Submittals on Project before editing the Paragraph.A.A. Make submittals in accordance with Section [01 77 00 - Closeout Procedures] [01 78 00 - Closeout Submittals].B.Operation and Maintenance Data:?Supply maintenance data for combination smoke and CO sensors for incorporation into manual specified in Section [01 77 00 - Closeout Procedures] [01 78 00 - Closeout Submittals] [01 78 23 - Operation and Maintenance Manuals].1.6?QUALITY ASSURANCEA.Electrician’s Qualifications:?Certification as journeyman or master electrician.1.7?DELIVERY, STORAGE AND HANDLINGA.Deliver materials in accordance with manufacturer’s written instructions.1.Deliver materials with identification labels intact and product name and manufacturer clearly visible.2.Replace materials damaged during delivery immediately.B.Store materials protected from exposure to harmful environmental conditions, clean, dry, frost-free and at recommended temperature and humidity levels.1.8?AMBIENT CONDITIONSA.Temperature Range:?40 to 100 degrees F.B.Humidity Range:?10 percent to 95 percent RH.1.9?WARRANTYA.Project Warranty:?Refer to Contract Conditions for Project warranty provisions.Specifier Note:?Retain and edit the following Paragraph to suit project requirements.B.Manufacturer’s warranty:?Submit, for Owner’s acceptance, manufacturer’s standard warranty document executed by authorized company official.1.Manufacturer’s warranty is in addition to and not intended to limit other rights Owner may have under Contract Conditions.PART 2 PRODUCTSSpecifier Note:?Retain Article below for proprietary method specification. Add product attributes performance characteristics, material standards and descriptions in other Articles as applicable. Use of such phrases as “or equal”, “approved equal”, or similar phrases may cause ambiguity in specifications. Such phrases require verification (procedural, legal and regulatory) and assignment of responsibility for determining or equal products.2.1?MANUFACTURERA.BRK Brands, Inc.B.Contact Information:?3901 Liberty Street, Aurora, IL?60504; Phone:?(630) 851-7330; Email:?info@; Website:.2.2?DESCRIPTIONA.Photoelectric and ionization combination smoke and CO sensors for residential and institutional applications.2.3?PERFORMANCE REQUIREMENTSA.Meet basic requirements of NFPA 101.ply with NFPA 72.ply with UL217.ply with requirements of UL 2034 for CO sensors.ply with requirements of U.S. Department of Housing and Urban Development (HUD).ply with requirements of California State Fire Marshall (CSFM).2.4?MATERIALSSpecifier Note:?Retain and edit the following Paragraph to suit Project requirements. Choose the 5 inches diameter and 2 inches options when specifying BRK combination smoke and CO alarms Cat # SC7010B, # SC7010BV, or # SCO500B. Choose the 5.4 x 5.4 x 1.4 inches high option when specifying BRK combination smoke and CO alarms Cat # 1042734, Model # SC7010LBLV. Choose the 5.6 inches diameter and 2 inches options when specifying BRK combination smoke and CO alarms Cat # SC9120B or # SC9120LBLA.Dimensions:?[ [5] [5.6] inches diameter x 2 inches high] [5.4 x 5.4 x 1.4 inches high].Specifier Note:?Retain and edit the following Paragraph to suit Project requirements. Choose the 8.4 ounces option when specifying BRK combination smoke and CO alarms Cat # SCO500B. Choose the 8.5 ounces option when specifying BRK combination smoke and CO alarms Cat # SC9120B or # SC09120LBL. Choose the 9.3 ounces option when specifying BRK combination smoke and CO alarms Cat # SC7010B or # SC7010BV. Choose the 10.6 ounces option when specifying BRK combination smoke and CO alarms Cat # 1042734, Model # SC7010LBLV.B.Weight:?[8.4] [8.5] [9.3] [10.6] ounces.Specifier Note:?Retain and edit the following Paragraph when specifying wire-in interconnected photoelectric combination smoke and CO alarms. Delete the following Paragraph in its entirety if Project requires wireless photoelectric combination smoke and CO alarms or ionization combination smoke and CO alarms. Include the option for voice warning when specifying BRK combination smoke and CO alarms Cat # # SC7010BV or SC7010LBLV.bination [voice warning] smoke and CO alarm with photoelectric smoke sensing chamber, electrochemical CO sensor, latching indicator alarm, and wire-in with battery backup.1.Ensure unit is capable of self-restoring.a.Alarm to reset when smoke or CO clears.2.Include insect screen on sensing chamber.Specifier Note:?Retain and edit the following Paragraph to meet Project requirements. Choose the option for two 1.5 V backup batteries when specifying BRK combination smoke and CO alarm Cat # SC7010B or # SC7010BV. Choose the option for a sealed lithium backup battery when specifying BRK combination smoke and CO alarm Cat # Model SC7010LBLV. 3.Operating voltage:?120 V, 60 Hz with [two 1.5 V] [3 V sealed lithium] battery backup.Specifier Note:?Retain and edit the following Paragraph to meet Project requirements.4.Operating current:?Choose the option of 0.05 operating current for both Standby and Alarm when specifying BRK combination smoke and CO alarm Cat # SC7010B or # SC7010BV. Choose the option of 0.012 Amps operating current for standby and 0.065 Amps operating current for alarm when specifying BRK combination smoke and CO alarm Cat # 1042734 -Model # 7010LBL.a.Standby:?[0.05] [0.012] Amps.b.Alarm:?[0.05] [0.065] Amps.5.Audio Alarm:?85 dB at 10 feet.Specifier Note:?Choose the option of 13 pre-programmed locations when specifying BRK combination smoke and CO alarm Cat # 1042734 -Model # SC7010LBLV only.6.Voice output:?Choice of [11] [13] pre-programmed locations.7.Indicator lights and sounds:Specifier Note:?Choose the clear option when specifying BRK combination smoke and CO alarm Cat # 1042734 -Model # SC7010LBLV only. a.AC power:?Constant [clear] [green] LED.Specifier Note:?Choose the clear option when specifying BRK combination smoke and CO alarm Cat # 1042734 -Model # SC7010LBLV only.b.DC power:?Intermittent [clear] [green] LED.Specifier Note:?Do not include the option for voice when specifying BRK combination smoke and CO alarm Cat # SC7010B.c.Local alarm:?Flashing red LED [with voice for “Smoke” or “CO” and location].Specifier Note:?Do not include the option for voice when specifying BRK combination smoke and CO alarm Cat # SC7010B.d.Remote alarm:?Red LED [off with voice for “Smoke” or “CO” and location].e.Latching alarm Indicators:Specifier Note:?Choose the following two Paragraphs only when specifying BRK combination smoke and CO alarm Cat # SC7010B or # SC7010BV. Delete the following Paragraph if specifying BRK combination smoke and CO alarm Cat # 1042734 -Model # SC7010LBLV.1)Red LED flashes every 5 second after local alarm.2)Low Battery chirp is Onece per minute on all replacable battery alarms.3)Smoke alarm:?Red LED 2 seconds on 2 seconds off continuously.4)CO alarm:?Blue LED 2 seconds on 2 seconds off continuously.5)Low backup battery:?Green LED 2 seconds on 2 seconds off continuously.Specifier Note:?Include the following Paragraph when specifying BRK smoke alarm # 1042736 -Model # SC7010LBLV only.6)Ten-year, sealed, backup battery end of life audio signal :?Five chirps at the end of their useful lives.8.Include test button:a.Capable of testing alarm functions by electronically simulating smoke and CO conditions.b.Test button to act as silence button for audio alarm:?Press and hold.9.Interconnections:?Ensure unit has plug in connector capable of connecting 18 alarms maximum.a.Maximum number of smoke alarms:?12.10.CO sensor settings:?Signal when CO levels are constant at 70 PPM between 60 and 240 minutes, and 150 PPM between 10 and 50 minutes and 400 PPM between 14 and 15 minutes.a.Ensure alarm remains dormant at 30 PPM or less for 30 days.11.Include gasketless base capable of keeping unit aligned and secure over wide rotation range.12.Include locking pins for battery drawer and alarm to base.13.Include construction dust cover.Specifier Note:?Retain and edit the following Paragraph to suit Project requirements. Choose BRK Cat # SC7010B when no voice warning is required. Choose BRK Cat # SC7010BV when voice warning is required but lithium backup battery is not essential. Choose BRK Cat # 1042734 -Model # SC7010LBLV when more pre-programmed voice warning locations and lithium backup battery are required.14.Acceptable Material:?BRK Brands, Inc. Smoke & CO Combo Alarm, Cat # [SC7010B] [SC7010BV] [1042734 -Model # SC7010LBLV].Specifier Note:?Retain and edit the following Paragraph when specifying wireless interconnected photoelectric combination smoke and CO alarms. Delete the following Paragraph in its entirety if Project requires combination smoke and CO alarms.bination talking smoke and CO alarm with photoelectric smoke sensing chamber, electrochemical CO sensor, mesh network communication with wireless interconnect, and battery operation.1.Ensure unit is capable of self-restoring.a.Alarm to reset when smoke clears and CO clears.2.Include insect screen on sensing chamber.3.Operating voltage:?Two 1.5 V AA batteries.4.Audio Alarm:?85 dB at 10 feet.5.Voice output:?Choice of 11 pre-programmed locations.6.Wireless frequency:?915 MHz, FCC approved.7.RF Linking:?Automatic with 65,000 security codes and 3 channel frequency hopping.8.Interconnections:?Capable of connecting by RF or hardwired with18 alarms maximum.a.Maximum number of smoke alarms:?12.9.CO sensor settings:?Signal when CO levels are constant at 70 PPM between 60 and 240 minutes, and 150 PPM between 10 and 50 minutes and 400 PPM between 14 and 15 minutes.a.Alarm will not sound at 30 PPM or less for 30 days.10.Include locking pins for battery drawer and alarm to base.11.Include construction dust cover.12.Acceptable Material:?BRK Brands, Inc. Smoke Alarm, Cat # SCO500B.Specifier Note:?Retain and edit the following Paragraph when specifying wire-in interconnected dual ionization combination smoke and CO alarms. Delete the following Paragraph in its entirety if Project requires photoelectric combination smoke and CO alarms.bination smoke and CO alarm with dual ionization smoke sensing chamber, electrochemical CO sensor, latching indicator alarm, and wire-in with battery backup.1.Ensure unit is capable of self-restoring.a.Alarm to reset when smoke or CO clears.2.Include insect screen on sensing chamber.Specifier Note:?Choose the option for an alkaline backup battery when specifying BRK combination smoke and CO alarm Cat # SC9120B.Choose the option for a sealed lithium backup battery when specifying BRK combination smoke and CO alarm Cat # L SC9120LBL.3.Operating voltage:?120 V, 60 Hz with 9 V [alkaline] [lithium] backup battery.4.Operating current:?0.09 Amps for both standby and alarm.5.Audio Alarm:?85 dB at 10 feet.6.Indicator lights and sounds:a.AC power:?Constant green LED.b.DC power:?Intermittent green LED.c.Local alarm:?Rapidly flashing red LED.d.Latching alarm:?Continuous red LED flash 2 second on and 2 second off after local alarm.e.Low battery latch:?Continuous green LED flash 2 second on and 2 second off after local alarm.f.Remote alarm:?Red LED out.g.Include test button:h.Capable of testing alarm functions by electronically simulating smoke and CO conditions.i.Test button to act as silence button for audio alarm:?Press and hold.j.Ten-year, sealed, backup battery end of life audio signal :?Five chirps at the end of their useful lives.7.Interconnections:?Ensure unit has plug in connector capable of connecting 18 alarms maximum.a.Maximum number of smoke alarms:?12.8.Include gasketless base capable of keeping unit aligned and secure over wide rotation range.Specifier Note:?Include the option for the battery drawer locking pin for BRK smoke alarm # SC9120B.9.Include locking pins for alarm to base [and battery drawer].10.Include construction dust cover.Specifier Note:?Retain and edit the following Paragraph to suit Project requirements. Choose BRK Cat # SC9120B when no voice audio warning is required. Choose BRK Cat # SC9120LBL when a sealed backup battery drawer is required.11.Acceptable Material:?BRK Brands, Inc. Smoke Alarm, Cat # [SC9120B] [SC9120LBL].2.5?ACCESSORIESA.Bridge for Hardwired Connections:1.Acceptable materials:?BRK Brands, Inc., Bridge, Cat # SA520B. PART 3 EXECUTION3.1?INSTALLER QUALIFICATIONSSpecifier Note:?In the following Paragraph edit the option for number of years experience to suit Project requirements.A.A. Use only licensed electricians for work of this Section.3.2?EXAMINATIONA.Verification of Conditions:?Verify that existing conditions or conditions previously installed under other Sections or Contracts are acceptable for Work of this Section.rm Architect of unacceptable conditions immediately upon discovery.2.Proceed with application only after unacceptable conditions have been remedied and after receipt of written approval to proceed from Architect.3.Starting installation of combination sensors implies conditions are acceptable for Work of this Section.3.3?INSTALLATIONA.Install in accordance with NFPA 70.B.Install in accordance with manufacturer’s written recommendations.C.Install combination smoke and CO alarms on [ceiling] [wall] [as indicated] [where directed].3.4?FIELD QUALITY CONTROLSpecifier Note:?Specify requirements if manufacturers are to provide field quality control with onsite personnel for instruction or supervision of product application. Manufacturer field reports are included under PART 1, Submittals.A.Manufacturer’s Services:Specifier Note:?Use the following Paragraphs only when manufacturer’s field services are provided and are required to verify the quality of the installation. Establish the number and duration of periodic site visits required by manufacturer and specify below. Contact BRK Brands, Inc. to determine any costs associated with Technical Representatives providing manufacturer’s field services. Delete the following Paragraph if field services are not required.1.Coordinate manufacturer’s services with Section [01 45 00 - Quality Control].Specifier Note:?Delete the following paragraph if no costs are associated with manufacturer’s services.2.Arrange for payment for manufacturer’s services.3.Have manufacturer review work involved in handling, placement, protection, touch-up and cleaning of combination sensors and submit written reports in acceptable format to verify compliance of Work with Contract Conditions.4.Manufacturer’s Field Services:?Provide manufacturer’s field services consisting of product use recommendations and periodic site visits for product installation review in accordance with manufacturer’s instructions.Specifier Note:?Retain and edit the following Paragraph to suit Contract Conditions.a.Report any inconsistencies from manufacturer’s recommendations immediately to Architect.Specifier Note:?Edit the following Paragraph to meet Project requirements. Coordinate site visits with manufacturer or delete the Paragraph and all of its subparagraphs if site visits are not required.5.Schedule site visits to review work at stages listed:a.After delivery and storage of combination sensors, and when preparatory work on which Work of this Section depends is complete, but before installation begins.b.During progress of work.c.Upon completion of Work.Specifier Note:?Retain and edit the following Paragraph to suit Contract Conditions.d.Obtain reports within three days of review and submit immediately to Architect.3.5?CLEANINGA.Perform daily progress cleaning.1.Leave work area clean at end of each day.B.Upon completion, remove surplus materials, rubbish, tools and equipment.C.Collect recyclable waste and dispose of in accordance with manufacturer’s written recommendations and at appropriate recycling facilities.Specifier Note:?Specify protection methods completed after installation, but prior to acceptance by the owner. Include only statements unique to this Section. Coordinate the following Article with Section 01 76 00 - Protecting Installed Construction.3.6?PROTECTIONA.Protect installed combination smoke and CO alarms from damage during construction.1.Protect combination smoke and CO alarms from dust with dust covers during construction.2.Remove dust covers from combination smoke and CO alarms only after construction is completed.B.Repair or replace adjacent materials damaged by installation of combination sensors.END OF SECTIOn ................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download