Vvarc.net



IMPORTANT KPC 3+ TNC COMMANDS A/O 23 MARCH 2018 USING IPSERIAL AFTER THE "CMD:" PROMPT, TYPE "DISPLAY", TAP RETURN/ENTER TO SEE THE CURRENT SETTINGS FOR EACH COMMAND. THE COMMANDS BELOW ARE IMPORTANT. IF THE SETTINGS DO NOT MATCH THE ONES IN RED, CHANGE THOSE SETTINGS TO MATCH THE ONES IN RED:BEACON “0” = NO BEACON – THIS THE DEFAULT SETTINGCD SOFTWARECHECK 0 (disabled)CONNECT: AT “CMD:” PROMPT, TYPE “C (SPACE) K7CCN-2, (RETURN)”. K7CCN-2 SHOULD BE ON 145.07MHz. IF NO CONNECTION W/I 30 SECONDS, PRESS "D" KEY OR RECYCLE TNC POWER BUTTON TO FORCE A DISCONNECT. PRESS "CONTOL & C" AT SAME TIME FOR THE "CMD:" PROMPT.CTEXT "CONNECTED TO [HOSPITAL ALIAS]" (EXAMPLE: CONNECTED TO SIENA, KG7MMU) DAYSTR Used only to set the format for the DAYTIME display (below). DO NOT enter a date/time! The preferred order is month, date, year, minutes, hours & seconds, but the format to be entered looks like this: mm/dd/yy(double space)hh:mm:ss (note the space between yy & hh); "seconds" are optional. NOTE: If a date/time is entered in DAYSTR the TNC clock will "freeze" to the entered time! DAYTIME has 2 uses: to enter/change the current date & time USING THE FORMAT SPECIFIED IN THE DAYSTR command above, AND to display the date/time that the TNC thinks it is, (Example: 04/13/17 11:05:00). To set/update a new date/time, enter the 2-digit numbers for each item: month, date, year, hour, minutes & seconds with NO spaces, dashes or slashes in this order: mmddyyhhmmss. For the example above, you would enter: "041317110500(enter)". At the "CMD" prompt, type "DAYTIME, enter" to check the date & time. W a minute, tap the "enter" key for CMD prompt, type "DAYTIME, enter". If the time didn't change, check the DAYSTR entry to verify the setting used to format the display of date/time matches the mmddyyhhmmss format & that there is a double space between the yy & hh entries. If it matches, check the DAYTIME entry to verify that it is formatted properly.DIGIPEAT OFF (FOR HOSPITALS) FLOW ONFRACK 5 (5 sec)HBAUD 1200HEADERLN ONHTEXT NV.USA.NOAMINTFACE TERMINALK: ENTERS CONVERSE MODE; TO EXIT CONVERSE MODE, PRESS & HOLD CTRL+CKNTIMER 15 minMONITOR ONMAXFRAME 1MAXUSERS 15MBEACON ONMHEARD: (SHOWS A LIST OF STATIONS HEARDMYCALL A CALL SIGN IS MANDATORY! (ENTER YOUR CALL SIGN IF NO CALL HAS BEEN ENTERED. REMEMBER TO DELETE IT BEFORE YOU SHUT DOWN THE STATION (ENTER, "NONE”, ENTER) AFTER THE MYCALL COMMAND, TO DELETE IT)MYALIAS [USE HOSPITAL’S ASSIGNED ALIAS-IF NO ALIAS HAS BEEN ENTERED REFER TO ALIAS LIST OR CONTACT NET CONTROL]MYNODE: DEFAULT IS THE MYCALL entry plus “-7”. (THE "-7" IS AUTOMATIC)MYPBBS: DEFAULT IS "(the MYCALL entry plus “-1" (THE “-1” IS AUTOMATIC) - CHECK CALLSIGN USED!NDWILD ONNEWMODE ONNUMNODES 0 (DEFAULT: MEANS NODE IS NOT BE ACTIVATED; IF NODE IS NEEDED, ENTER "2")PACLEN 80PACTIME AFTER 10 (1000 msec)PBBS 100PERSIST 63PTEXT IF NO TEXT IS PROGRAMMED, ENTER "CONNECTED TO MAILBOX AT (HOSPITAL ALIAS)"RETRY 10TXDELAY 40 (400 msec) USERS 10 ................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download