Resusci anne faq - Laerdal Medical

[Pages:22]MicroSim

Frequently Asked Questions

1

SimSeulfla-dtiorenctfoerd elemaernrginegncsysctaerme

Resusci Anne Simulator

Frequently Asked Questions

7871 rev A

resusci_anne_faq.indd 1

23-11-2004 09:50:35

Resusci Anne Simulator

Frequently Asked Questions

7871 rev A

2

resusci_anne_faq.indd 2



23-11-2004 09:50:35

Resusci Anne Simulator

Frequently Asked Questions

Table of Contents

CONTENTS

TECHNICAL............................................................................................... 6

1. I have just received my Resusci Anne Simulator. What contents are supposed to be included?

2. I received educational support material with my Resusci Anne Simulator. How is this to be used?

3. I received a software CD containing two programs to use with the Resusci Anne Simulator. Do I have to connect the PC in order to run the simulator?

4. I received an AC power adapter with the Resusci Anne simulator. Do I have to use AC power to operate the simulator?

5. How long can I run on batteries alone? 6. What selections of heart, lung and vocal sounds are available with the Resusci

Anne Simulator? 7. How do the heart, lung and vocal sounds work? 8. I would like to introduce live voice responses during a training session. Can the

simulator be used with an external microphone? 9. How many different heart rhythm variations are available with the Resusci

Anne Simulator? 10. How does the spontaneous breathing chest rise-and-fall work? 11. How much pressure can the air container in the Resusci Anne Simulator hold? 12. How long will the Resusci Anne Simulator's spontaneous chest rise-and-fall

breathe before the compressed air tank needs to be refilled? 13. How far away can I stand with the remote control and still be able to run the

Resusci Anne Simulator? 14. How many simulators can I control with one remote?

resusci_anne_faq.indd 3



3

23-11-2004 09:50:36

7871 rev A 7871 rev A

Resusci Anne Simulator

Frequently Asked Questions

Table of Contents

15. What happens if more than one simulator is in the room and I am using the remote control?

16. Can the Resusci Anne Simulator be upgraded with wound modules for first aid training?

17 Why did I receive a manual air pump with the simulator? 18. Do I have to use the manual air pump to fill the simulator's spontaneous

breathing compressed air container? 19. Will I damage the compressed air container if I over fill it with a pressure

above 10 Bar / 145 PSI? 20. The Resusci Anne Simulator comes with an airway management head. What

airway techniques can I perform? 21. Are there any special lubrication recommendations when performing airway

techniques on the simulator? 22. Can I intubate the airway? 23. Can I perform mouth-to-mouth or mouth-to-mask ventilations on the Resusci

Anne Simulator? 24. What is the Eye Set for? 25. One of the features of the Resusci Anne Simulator is the ability to introduce

and obstructed airway during training. How does the airway obstruction feature work? 26. Do I have to have a PC connection in order to get CPR performance feedback? 27. If the airway should ever tear, does the entire head need to be replaced or can the airway be replaced as a separate part? 28. How do I clean the simulator?

7871 rev A

4

resusci_anne_faq.indd 4



23-11-2004 09:50:36

Resusci Anne Simulator

Frequently Asked Questions

Table of Contents

LAERDAL PC SKILLREPORTING SYSTEM ....................................... 17

1. What is the intended use of this software program? 2. What are the computer requirements for installing and running the Laerdal PC

SkillReporting System and Scenario Builder software? 3. Are there HELP files included in the software? 4. How many student performance logs can be saved to the manikin at one

time? 5. Will my student logs be erased within a certain period of time if not down-

loaded to the computer? 6. Will my student logs or scenarios be erased if the Resusci Anne Simulator's

batteries die?

SCENARIO BUILDER SOFTWARE ..................................................... 20

1. What is the scenario builder program? 2. How many scenarios can be uploaded to the simulator at one time? 3. How do I build my own scenario?

7871 rev A 7871 rev A

resusci_anne_faq.indd 5



5

23-11-2004 09:50:36

Technical

Resusci Anne Simulator

Frequently Asked Questions

INTERNAL

6

resusci_anne_faq.indd 6

1. I have just received my Resusci Anne Simulator. What contents are supposed to be included?

Items included

Please check that all listed contents below are included. ? Torso including: ? Airway Management Head ? Pelvis ? Blood Pressure arm with cuff ? IV arm ? Extrication / Rescue Legs ? Remote Control including batteries ? Remote Control cable (for use when RF communication is not allowed) ? Power cord for AC wall adapter ? 1 bottle simulated blood ? 1 can Lubricant ? Manual defibrillation plates ? Full body soft pack ? Resusci Anne Simulator Eye Set ? Air pump ? Directions for Use ? Track suit including jacket and pants ? Educational Support Manual with predefined training scenarios ? Software CD and USB interface cable

2. I received educational support material with my Resusci Anne Simulator. How is this to be used?

The educational learning material package consists of many tools designed to help you optimize your training sessions. The material that is included is as follows:

? 10 predefined pre-hospital patient cases designed for emergency medical service personnel.

? 10 predefined in-hospital patient cases designed for hospital personnel such as nurses and residents in the emergency and intensive care departments.

? A curriculum mapping poster for assistance in matching these patient cases with curriculum learning objectives and requirements

7871 rev A



23-11-2004 09:50:36

Resusci Anne Simulator

Frequently Asked Questions

Technical

? Product directions for use ? Software to optimize the learning experience.

3. I received a software CD containing two programs to use with the Resusci Anne Simulator. Do I have to connect the PC in order to run the simulator?

No. One of the great features of the Resusci Anne Simulator is that you do not need to have a PC connected in order to realize its full potential in most training situations. It is designed to optimize true simulation by offering complete remote control functionality. As an added feature, the Laerdal PC SkillReporting System software is available for the user for a number of training benefits as follows:

1. Extensive Database Management ? Instructor and student details ? Training performance data can be logged, saved and retrieved for later review ? Data can be imported and exported

2. Hub system ? Control up to 8 Resusci Anne Simulators simultaneously from one PC ? Run common scenarios as part of the classroom training ? Monitor "real-time" scenario development and performance ? Control individual or multiple simulators from one PC

3. Debriefing features ? Student performance can be evaluated against to individual guideline preferences

A second program is provided called the Scenario Editor. The scenario editor allows the user to build their own training scenarios that can be customized to individual training protocols. These scenarios can then be uploaded to the simulator for customized training situations.

Note: see later section for more details about these software applications

resusci_anne_faq.indd 7



7

23-11-2004 09:50:36

7871 rev A 7871 rev A

Technical

Resusci Anne Simulator

Frequently Asked Questions

8

resusci_anne_faq.indd 8

4. I received an AC power adapter with the Resusci Anne simulator. Do I have to use AC power to operate the simulator? No. The power adapter is provided to allow the user this option if he or she does not need to run the simulator via battery operation.

5. How long can I run on batteries alone? The battery life of the 8 D-Cell batteries in the simulator's torso is completely dependent upon the use of the simulator. If all of the sounds, pulses, spontaneous breathing and voice features are used extensively the life of the batteries will vary. Internal testing has shown the battery life to vary between 30 and 40 hours of operation under normal use of the simulator's features.

6. What selections of heart, lung and vocal sounds are available with the Resusci Anne Simulator?

The following sounds are available with the Resusci Anne Simulator and can be controlled/introduced via the remote control unit:

HEART SOUNDS (Synchronized with programmable ECG) - Aortic Stenosis - Friction Rub - Austin Flint Murmur - Diastolic Murmur - Systolic Murmur - Mitral Valve Prolapse - Opening Snap - Normal

LUNG SOUNDS (Synchronized with breathing rate, 0 ? 60 breaths per minute with individual lung or bilateral sound selection)

- Normal - Crackles - Pneumonia - Stridor - Wheezes - Rhonchi - No sound



23-11-2004 09:50:36

7871 rev A

................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download