Minutes of the Ohio Corrosion Committee



OHIO CORROSION COMMITTEE CASES

Updated 12-1-2016

New Cases – 2016

OCC Case 2016-01

Name: Gabe Hyndman

Email: Gabe.Hyndman@

Company: Markwest

Phone: 330-365-0522

Rectifier Address: TR 269 CADIZ OH

Rectifier City: Cadiz

Rectifier County: Harrison

GPS Coordinates North: 40.2460355

GPS Coordinates West: 081.0836013

Ground Bed Type: Deep Well

Rated Volts: 40 Present Volts: 4

Rated Amps: 30 Present Amps: 2

Companies Involved: DEOG-D*, DEOG-T, TCO

Comments: still making adjustments

OCC Case 2016-02

Name: Gabe Hyndman

Email: Gabe.Hyndman@

Company: Markwest

Phone: 330-365-0522

Rectifier Address: 1400 TOWNSHIP RD 189

Rectifier City: Bloomingdale

Rectifier County: Jefferson

GPS Coordinates North: N40.30673

GPS Coordinates West: W080.70343

Ground Bed Type: Deep Well

Rated Volts: 75 Present Volts: 16

Rated Amps: 60 Present Amps: 15

Companies Involved: DEOG-T

Comments: still making adjustments

OCC Case 2016-03

Name: Ken Marshall

Email: krmarshall@

Company: Sunoco

Phone: (330) 807-0705

Rectifier Address: 1309 Conwell Rd. (US 224)

Rectifier City: Willard

Rectifier County: Huron

GPS Coordinates North: 41.038392

GPS Coordinates West: -082.714467

Ground Bed Type: Distributed

Rated Volts: 60 Present Volts: 9.80

Rated Amps: 30 Present Amps: 5.5

Proposed Test Date: Can call

Companies Involved: DEOG-T

Comments: This is an upgrade to an existing system that was operational just east of this location. (East side of the pump station outside the fence) *NOTE* = As of 3-22-16, I had to tie in the old 8" line in the rectifier.

OCC Case 2016-04

Name: Ken Marshall

Email: krmarshall@

Company: Sunoco Logistics

Phone: (330) 807-0705

Rectifier Address: 342 CR 500

Rectifier City: Sullivan

Rectifier County: Ashland

GPS Coordinates North: 40.992317

GPS Coordinates West: -082.193583

Ground Bed Type: Deep Well

Rated Volts: 60

Rated Amps: 30

Present Volts: 16.65

Present Amps: 8.0

Proposed Test Date: Can call

Companies Involved: TCO, COH

Comments: This is an upgrade to an existing service that is east of this location. Old service has not been on in years. *NOTE* = As of 3-22-16 the old 8" line was tied in at the rectifier. Rectifier is up and running.

OCC Case 2016-05

Name: Ken Marshall

Email: krmarshall@

Company: Sunoco Logistics

Phone: (330) 807-0705

Rectifier Address: 13367 Friendsville Road

Rectifier City: Burbank

Rectifier County: Wayne

GPS Coordinates North: 40.960783

GPS Coordinates West: -81.957258

Ground Bed Type: Deep Well

Rated Volts: 60

Rated Amps: 30

Present Volts: 20

Present Amps: 8

Proposed Test Date: Can call

Companies Involved: TCO, COH

Comments: This is a new service to replace an existing service that was operational at this location previously. Had to tie in the old 8" line.

OCC Case 2016-06

Name: Bob Sperling

Email: bob_sperling@

Company: Ohio Gas Company

Phone: 419-630-2241

Rectifier Address: 117 E. Lynn St.

Rectifier City: Stryker

Rectifier County: Williams

GPS Coordinates North: 41.503970

GPS Coordinates West: -84.411790

Ground Bed Type: Local

Rated Volts: 30

Rated Amps: 16

Proposed Test Date: As needed

Companies Involved: Buckeye

Comments: In service 11/18/2016, set at 5.5V, 5.4A will evaluate and adjust in early 2017. Replacing a rectifier located 5/8 mile east at 41.507300, -84.400000.

OCC Case 2016-07

Name: Ken Marshall

Email: krmarshall@

Company: Sunoco Logistics

Phone: (330) 807-0705

Rectifier Address: 3531 Section Line Road

Rectifier City: Willard

Rectifier County: Huron

GPS Coordinates North: 41.047140

GPS Coordinates West: -82.782235

Ground Bed Type: Local

Rated Volts: 60

Rated Amps: 30

Present Volts: 6.74

Present Amps: 11

Proposed Test Date: Can call

Companies Involved: COH, TCO

Comments: Rectifier is now running. This is an upgrade to a system that was operational here before. Still working on getting other rectifiers powered up on this line segment.

OCC Case 2016-08

Name: Ken Marshall

Email: krmarshall@

Company: Sunoco Logistics

Phone: (330) 807-0705

Rectifier Address: 12651 Eby Road (Township Road 73)

Rectifier City: Creston

Rectifier County: Wayne

GPS Coordinates North: 40.953373

GPS Coordinates West: -081.864403

Ground Bed Type: Deep Well

Rated Volts: 60

Rated Amps: 20

Present Volts: 12.43

Present Amps: 8.30

Proposed Test Date: Can call

Companies Involved: COH, TOC

Comments: This is an upgrade to an existing service that was at this location previously. Old system was off. Protecting both lines (8"/12")

2015 Cases

OCC Case 2015-03

Name: j dado

Email: jdado@

Company: Columbia Gas of Ohio

Phone: 614-402-8397

Rectifier Address: 611 walnut

Rectifier City: Columbus

Rectifier County: Franklin

GPS Coordinates North: 39.959892

GPS Coordinates West: -82.983331

Ground Bed Type: Deep Well

Rated Volts: 50

Rated Amps: 25

Present Volts: 4.5

Present Amps: 1.6

Proposed Test Date: when ever

Companies Involved: AEP, Marathon

Comments: no other gas co. in Columbus

OCC Case 2015-04

Name: Kevin Berard

Email: kevin.berard@

Company: BP Pipeline

Phone: 773-562-8230

Rectifier Address: 3601 W Springboro rd

Rectifier City: Springboro

Rectifier County: Warren

GPS Coordinates North: 39.5469031

GPS Coordinates West: -84.2693682

Ground Bed Type: Deep Well

Rated Volts: 50

Rated Amps: 20

Present Volts: 10.44

Present Amps: 5.85

Companies Involved: DTI, Sunoco, Marathon*

Comments: Relocated an existing rectifier site to a new location approx. 2,000' south of the existing site. Retired the existing rectifier and conventional bed and installed a deep well bed at the new rectifier site.

OCC Case 2015-05

Name: Kevin Berard

Email: kevin.berard@

Company: BP Pipeline

Phone: 773-562-8230

Rectifier Address: 3601 W Springboro rd

Rectifier City: Dayton

Rectifier County: Montgomery

GPS Coordinates North: 39.78688431

GPS Coordinates West: -84.16233063

Ground Bed Type: Deep Well

Rated Volts: 60

Rated Amps: 40

Present Volts: 54

Present Amps: 21.9

Companies Involved: DTI, Sunoco, Marathon*

Comments: Replaced the existing rectifier inside BP's Dayton station facility with a new rectifier in the same location. The existing conventional anode bed was replaced with a new deepwell anode bed

OCC Case 2015-06

Name: Levi Wells

Email: mlwells@

Company: Enterprise Products (TETLP)

Phone: 513-420-6531

Rectifier Address: 399 Schenley Ave

Rectifier City: Steubenville

Rectifier County: Jefferson

GPS Coordinates North: 40.39910

GPS Coordinates West: -80.63082

Ground Bed Type: Deep Well

Rated Volts: 80

Rated Amps: 40

Present Volts: 8

Present Amps: 9

Companies Involved: COH, DTI, Marathon, DEOG-T*

Comments: New Rectifier and Groundbed installed in fall of 2014 by Enterprise products for the new 20" ATEX line. Planned CIS starting middle of March 2015.

OCC Case 2015-07

Name: Levi Wells

Email: mlwells@

Company: Enterprise Products (TETLP)

Phone: 513-420-6531

Rectifier Address: 83750 Wallace Rd

Rectifier City: Cadiz

Rectifier County: Harrison

GPS Coordinates North: 40.30801

GPS Coordinates West: -81.09677

Ground Bed Type: Local

Rated Volts: 80

Rated Amps: 40

Present Volts: 8

Present Amps: 6

Companies Involved: COH*, TCO*, Markwest, DTI, DEOG-T

Comments: New Rectifier and Groundbed installed in fall of 2014 by Enterprise products for the new 20" ATEX line. Planned CIS starting middle of March 2015.

OCC Case 2015-08

Name: Levi Wells

Email: mlwells@

Company: Enterprise Products (TETLP)

Phone: 513-420-6531

Rectifier Address: 15610 CR8

Rectifier City: Newcomerstown

Rectifier County: Tuscarawas

GPS Coordinates North: 40.25404

GPS Coordinates West: -81.46786

Ground Bed Type: Deep Well

Rated Volts: 80

Rated Amps: 40

Present Volts: 8

Present Amps: 8

Companies Involved: COH*, DTI, DEOG-T

Comments: New Rectifier and Groundbed installed in fall of 2014 by Enterprise products for the new 20" ATEX line. Planned CIS starting middle of March 2015.

OCC Case 2015-10

Name: Levi Wells

Email: mlwells@

Company: Enterprise Products (TETLP)

Phone: 513-420-6531

Rectifier Address: 6200 Fairmont Rd

Rectifier City: Heath

Rectifier County: Licking

GPS Coordinates North: 39.9979

GPS Coordinates West: -82.3865

Ground Bed Type: Deep Well

Rated Volts: 80

Rated Amps: 40

Present Volts: 7

Present Amps: 6

Companies Involved: DTI, NGO*

Comments: New Rectifier and Groundbed installed in fall of 2014 by Enterprise products for the new 20" ATEX line. Planned CIS starting in the middle of March 2015.

OCC Case 2015-11

Name: Levi Wells

Email: mlwells@

Company: Enterprise Products (TETLP)

Phone: 513-420-6531

Rectifier Address: 120 Cedar Hill Rd

Rectifier City: Amanda

Rectifier County: Fairfield

GPS Coordinates North: 39.7334

GPS Coordinates West: -82.8013

Ground Bed Type: Deep Well

Rated Volts: 80

Rated Amps: 40

Present Volts: 9

Present Amps: 8

Companies Involved: Marathon, COH*

Comments: New Rectifier and Groundbed installed in fall of 2014 by Enterprise products for the new 20" ATEX line. Planned CIS starting in the middle of March 2015.

OCC Case 2015-12

Name: Levi Wells

Email: mlwells@

Company: Enterprise Products

Phone: 513-420-6531

Rectifier Address: 4800 HWY 207

Rectifier City: Washington Court House

Rectifier County: Fayette

GPS Coordinates North: 39.6321

GPS Coordinates West: -83.2698

Ground Bed Type: Deep Well

Rated Volts: 80

Rated Amps: 40

Present Volts: 8

Present Amps: 8

Companies Involved: DTI*, Vectren, Marathon*

Comments: New Rectifier and Groundbed installed in fall of 2014 by Enterprise products for the new 20" ATEX line. Planned CIS starting in the middle of March 2015.

OCC Case 2015-14

Name: Levi Wells

Email: mlwells@

Company: Enterprise Products (TETLP)

Phone: 513-420-6531

Rectifier Address: 6450 Grassy Branch Rd

Rectifier City: Sabina

Rectifier County: Fayette

GPS Coordinates North: 39.5751

GPS Coordinates West: -83.6187

Ground Bed Type: Deep Well

Rated Volts: 80

Rated Amps: 40

Present Volts: 10

Present Amps: 8

Companies Involved: DTI*, Vectren

Comments: New Rectifier and Groundbed installed in fall of 2014 by Enterprise products for the new 20" ATEX line. Planned CIS starting middle of March 2015.

OCC Case 2015-15

Name: Levi Wells

Email: mlwells@

Company: Enterprise Products (TETLP)

Phone: 513-420-6531

Rectifier Address: 8930 State Route 380

Rectifier City: Wilmington

Rectifier County: Clinton

GPS Coordinates North: 39.5556

GPS Coordinates West: -83.9639

Ground Bed Type: Deep Well

Rated Volts: 80

Rated Amps: 40

Present Volts: 12

Present Amps: 10

Companies Involved: DTI, Vectren

Comments: New Rectifier and Groundbed installed in fall of 2014 by Enterprise products for the new 20" ATEX line. Planned CIS starting middle of March 2015.

OCC Case 2015-16

Name: Levi Wells

Email: mlwells@

Company: Enterprise Products

Phone: 513-420-6531

Rectifier Address: Union Rd

Rectifier City: Lebanon

Rectifier County: Warren

GPS Coordinates North: 39.46182

GPS Coordinates West: -84.32093

Ground Bed Type: Deep Well

Rated Volts: 80

Rated Amps: 40

Present Volts: 6

Present Amps: 6

Companies Involved: DTI, Duke, Vectren

Comments: New Rectifier and Groundbed installed in fall of 2014 by Enterprise products for the new 20" ATEX line. Planned CIS

starting middle of March 2015.

OCC Case 2015-17

Name: Ken Marshall

Email: krmarshall@

Company: Sunoco Logistics

Phone: (330) 807-0705

Rectifier Address: 11630 CR 56

Rectifier City: Attica

Rectifier County: Seneca

GPS Coordinates North: 41.066433

GPS Coordinates West: -82.94675

Ground Bed Type: Distributed

Rated Volts: 60

Rated Amps: 30

Present Volts: 29.00

Present Amps: 7.0

Companies Involved: TCO, COH

Proposed Test Date: Can call

Comments: This is an upgrade to an existing system that was operational at this location previously. 3/28/2016 – The old 8” line has been connected to the rectifier and the output has been increased.

OCC Case 2015-18

Name: Gabe Hyndman

Email: Gabe.Hyndman@

Company: Markwest

Phone: 330-365-0522

Rectifier Address: Miltonsberg Calais Rd

Rectifier City: Summerfield Ohio

Rectifier County: Noble

GPS Coordinates North: 39.86024

GPS Coordinates West: 081.30609

Ground Bed Type: Deep Well

Rated Volts: 40

Rated Amps: 30

Present Volts: 6.1

Present Amps: 6.7

Proposed Test Date: To be determined

Companies Involved: Tall Grass, Blue Racer, DTC, TCO, DTI, DEOG-T*, ANTERO*

Comments: Been in contact with Tall Grass:

If there are any other companies please provide the contact info. Still making some final adjustments

OCC Case 2015-19

Name: Gabe Hyndman

Email: Gabe.Hyndman@

Company: Markwest

Phone: 330-365-0522

Rectifier Address: RT 250

Rectifier City: Cadiz

Rectifier County: Harrison

GPS Coordinates North: 40 17'39.08"

GPS Coordinates West: 081 01'59.84"

Ground Bed Type: Deep Well

Rated Volts: 40

Rated Amps: 20

Present Volts: 1.5

Present Amps: 0.25

Proposed Test Date: To be determined

Companies Involved: Columbia Transmission*, Blue Racer, DEOG-T*, DTI*

Comments: These are known companies. I have already met with Columbia, and I need a contact for Blue Racer.

Still making some final adjustments.

OCC Case 2015-20

Name: Ken Marshall

Email: krmarshall@

Company: Sunoco Logistics

Phone: (330) 379-2839/(330) 807-0705

Rectifier Address: 2648 S. County Road 17 (Swander Road)

Rectifier City: Tiffin

Rectifier County: Ohio

GPS Coordinates North: 41.08375168

GPS Coordinates West: -083.0931015

Ground Bed Type: Distributed

Rated Volts: 60

Rated Amps: 30

Present Volts: 26.00

Present Amps: 14.5

Proposed Test Date: As needed

Companies Involved: TCO, COH

Comments: This is an upgrade to an existing system that was previously operating at this location. 3/28/2016 – The old 8” line has been connected to the rectifier and the output has been increased.

OCC Case 2015-21

Name: Ken Marshall

Email: krmarshall@

Company: Sunoco Logistics

Phone: (330) 379-2839/(330) 807-0705

Rectifier Address: 466 County Road 681

Rectifier City: Sullivan

Rectifier County: Ohio

GPS Coordinates North: 40.997744

GPS Coordinates West: -082.261902

Ground Bed Type: Deep Well

Rated Volts: 60

Rated Amps: 30

Present Volts: 16.0

Present Amps: 15.0

Proposed Test Date: As needed

Companies Involved: TCO, COH

Comments: This is an upgrade to an existing system that was operational at this location, but across the road now. Reactivated 8-8-15.

3/28/2016 – The old 8” line has been connected to the rectifier and the output has been increased.

OCC Case 2015-22

Name: Duane A Huffman

Email: dahuffman@

Company: Columbia Pipeline Group

Phone: 330-309-1920

Rectifier Address: Dutch Ridge Rd

Rectifier City: New Rumley

Rectifier County: Harrison

GPS Coordinates North: N40.39294

GPS Coordinates West: -W81.05464

Ground Bed Type: Local

Rated Volts: 60

Rated Amps: 60

Present Volts: 13

Present Amps: 2

Companies Involved: DEOG-T, AEP

Comments: Remote ground bed

OCC Case 2015-23

Name: Duane A Huffman

Email: dahuffman@

Company: Columbia Pipeline Group

Phone: 330- 309-1920

Rectifier Address: Sally Buffalo Park

Rectifier City: Cadiz

Rectifier County: Harrison

GPS Coordinates North: N40.26372

GPS Coordinates West: -W81.00869

Ground Bed Type: Local

Rated Volts: 60

Rated Amps: 60

Present Volts: 7

Present Amps: 4.5

Companies Involved: Markwest, Energy Transfer, DEOG-T

Comments: Remote ground bed - Rectifier in Sally Buffalo Park near the last Y to Softball fields.

OCC Case 2015-24

Name: Ken Marshall

Email: krmarshall@

Company: Sunoco Logistics

Phone: 330-379-2839

Rectifier Address: 1920 Schneider Road

Rectifier City: Canton

Rectifier County: Stark

GPS Coordinates North: 40.866329

GPS Coordinates West: -081.347181

Ground Bed Type: Deep Well

Rated Volts: 60

Rated Amps: 20

Present Volts: 4.26

Present Amps: 2.10

Proposed Test Date: Can call

Companies Involved: DEOG-D, DEOG-T

Comments: This is at the High Mill Church on the south side of Schneider Road, near the flag poles by building. Across from GlenOak High School/Mercy Medical Center.

OCC Case 2015-25

Name: Ken Marshall

Email: krmarshall@

Company: Sunoco Logistics

Phone: 330-379-2839

Rectifier Address: Kent Ave.

Rectifier City: Hartville

Rectifier County: Stark

GPS Coordinates North: 40.969018

GPS Coordinates West: -081.339438

Ground Bed Type: Deep Well

Rated Volts: 60 Present Volts: 30

Rated Amps: 20 Present Amps: 4

Proposed Test Date: Can call

Companies Involved: DEOG-D

Comments: Activated 5-4-2016. This is north of SR 619 (Edison Street), at the plaza facing the end of the building, near "Irene's Restaurant". (North of the Ford dealership).

2014 Cases

OCC Case 2014-01

Name: Daniel R Achauer

Email: daniel_achauer@

Company: Tennessee Gas Pipeline

Phone: 740-638-2101 ext 2029

Rectifier Address: Collier Road

Rectifier City: South Webster

Rectifier County: Scioto

GPS Coordinates North: 38.812156

GPS Coordinates West: -82.707164

Ground Bed Type: Local

Rated Volts: 40 Present Volts: 23.6

Rated Amps: 20 Present Amps: 5.16

Proposed Test Date: TBD

Companies Involved: Texas Eastern (TETLP), COH*

Comments: This is one of two rectifiers I have installed at this location. The first one is for a remote bed and the second is for linear anode strings at the crossings. I have already shared information with both Texas Eastern and Col Gas.

OCC Case 2014-02

Name: Daniel R Achauer

Email: daniel_achauer@

Company: Tennessee Gas Pipeline

Phone: 740-638-2101 ext 2029

Rectifier Address: Collier Road

Rectifier City: South Webster

Rectifier County: Scioto

GPS Coordinates North: 38.812156

GPS Coordinates West: -82.707164

Ground Bed Type: Distributed

Rated Volts: 2 Present Volts: 1.926

Rated Amps: 10 Present Amps: 0.94

Proposed Test Date: TBD

Companies Involved: Texas Eastern (TETLP), COH*

Comments: This is one of two rectifiers I have installed at this location. This unit is for the Linear Anode Strings at the crossings. I have already shared information with both Texas Eastern and Col Gas.

OCC Case 2014-03

Name: Daniel R Achauer

Email: daniel_achauer@

Company: Tennessee Gas Pipeline

Phone: 740-638-2101 ext 2029

Rectifier Address: Pyle Lane

Rectifier City: Kimbolton

Rectifier County: Guernsey

GPS Coordinates North: 40.137448

GPS Coordinates West: -81.546754

Ground Bed Type: Local

Rated Volts: 50 Present Volts: 11.96

Rated Amps: 30 Present Amps: 5.88

Proposed Test Date: TBD

Companies Involved: DEOG-D*, DEOG-T*, OOG

Comments: This is one of two rectifiers I installed at this location. The first is for a remote bed along the lane and the second is for a Linear Anode String along our line south.

OCC Case 2014-04

Name: Daniel R Achauer

Email: daniel_achauer@

Company: Tennessee Gas Pipeline

Phone: 740-638-2101 ext 2029

Rectifier Address: Pyle Lane

Rectifier City: Kimbolton

Rectifier County: Guernsey

GPS Coordinates North: 40.137448

GPS Coordinates West: -81.546754

Ground Bed Type: Distributed

Rated Volts: 20

Rated Amps: 10

Present Volts: 2.48

Present Amps: 0.3

Proposed Test Date: TBD

Companies Involved: DEOG-D*, DEOG-T*, OOG

Comments: This is one of two rectifiers I have installed at this location. This second unit is for a Linear Anode String I installed along the pipeline south.

OCC Case 2014-06

Name: Jeff Brown

Email: jbrown@

Company: Buckeye Partners

Phone: 419-234-6095

Rectifier Address: W/S Dixie Highway S/O Marathon

Rectifier City: Lima

Rectifier County: Allen

GPS Coordinates North: 40.701812322

GPS Coordinates West: -84.12172889

Ground Bed Type: Local

Rated Volts: 50

Rated Amps: 50

Proposed Test Date: will call

Companies Involved: Marathon, Mid Valley, DEOG-T, DTI*

Comments: 100 Ft X 12" Anode-well protecting 3 pipelines leaving our Lima Pump Station going East across I-75.

Projected output is 15A.

OCC Case 2014-08

Name: Gabe Hyndman

Email: Gabe.Hyndman@

Company: Markwest Energy Partners

Phone: 330-365-0522

Rectifier Address: Dump rd

Rectifier City: Cadiz

Rectifier County: Harrison County

GPS Coordinates North: 40 17'30.33” (?)

GPS Coordinates West: 081 55'29.45" (?)

Ground Bed Type: Deep Well

Rated Volts: 40V

Rated Amps: 30A

Present Volts: 29v

Present Amps: 18.8a

Proposed Test Date: To be determined

Companies Involved: DEOG-D*, COH, TCO*

Comments: No known Foreign Line Crossings

OCC Case 2014-09

Name: Gabe Hyndan

Email: Gabe.Hyndman@

Company: Markwest Energy Partners

Phone: 330-365-0522

Rectifier Address: Cadiz Piedmont Rd (Rt 22)

Rectifier City: Cadiz

Rectifier County: Harrison County

GPS Coordinates North: 40 14.341'

GPS Coordinates West: 081 04.768'

Ground Bed Type: Deep Well

Rated Volts: 100

Rated Amps: 30

Present Volts: 22.2

Present Amps: 23.6

Proposed Test Date: To be determined

Companies Involved: DEOG-D*, Enterprise Production, Enerest, COH, TCO*, DEOG-T*

Comments: These are the Companies crossing our pipelines. If there are any other companies please provide the contact info.

OCC Case 2014-10

Name: Gabe Hyndman

Email: Gabe.Hyndman@

Company: Markwest Energy Partners

Phone: 330-365-0522

Rectifier Address: Reservoir RD

Rectifier City: Flushing

Rectifier County: Belmont county

GPS Coordinates North: 40.160575

GPS Coordinates West: 081.093356

Ground Bed Type: Deep Well

Rated Volts: 40

Rated Amps: 30

Present Volts: 19.4

Present Amps: 24.6

Proposed Test Date: To be determine

Companies Involved: DEOG-D*, TCO, Tall Grass, DEOG-T*, COH

Comments: These are the companies crossing our pipelines. If there are any other Companies please provide me with the contact info.

OCC Case 2014-11

Name: Gabe Hyndman

Email: Gabe.Hyndman@

Company: Markwest Energy Partners

Phone: 330-365-0522

Rectifier Address: Egypt North rd

Rectifier City: Flushing

Rectifier County: Belmont county

GPS Coordinates North: 40.070453

GPS Coordinates West: 081.124813

Ground Bed Type: Deep Well

Rated Volts: 40

Rated Amps: 30

Present Volts: 15.8

Present Amps: 20

Proposed Test Date: To be determine

Companies Involved: DEOG-D*, TCO, Tall Grass, DEOG-T*

Comments: These are the companies crossing our pipeline. If there are any other companies please provide the contact info.

OCC Case 2014-12

Name: Bob Sperling

Email: bob_sperling@

Company: Ohio Gas Company

Phone: 419-630-2241

Rectifier Address: F-995 Road 10

Rectifier City: Hamler

Rectifier County: Henry

GPS Coordinates North: 41.253667

GPS Coordinates West: 084.05575

Ground Bed Type: Local

Rated Volts: 60

Rated Amps: 40

Present Volts: 2.9

Present Amps: 3.2

Proposed Test Date: As needed

Companies Involved: Crossroads, KNG, Buckeye

Comments: The output will be increased in early 2016. This is a new installation to protect a segment of rural pipeline.

OCC Case 2014-14

Name: Bob Sperling

Email: bob_sperling@

Company: Ohio Gas Company

Phone: 419-630-2241

Rectifier Address: 4-234 State Route 18

Rectifier City: Deshler

Rectifier County: Henry

GPS Coordinates North: 41.225583

GPS Coordinates West: 083.944333

Ground Bed Type: Local

Rated Volts: 60

Rated Amps: 40

Present Volts: 2.9

Present Amps: 3.0

Proposed Test Date: As needed

Companies Involved: Crossroads, KNG, Buckeye

Comments: The output will be increased in early 2016. This is a new installation to protect a segment of rural pipeline.

OCC Case 2014-15

Name: Bob Sperling

Email: bob_sperling@

Company: Ohio Gas Company

Phone: 419-630-2241

Rectifier Address: 5-592 State Route 18

Rectifier City: Deshler

Rectifier County: Henry

GPS Coordinates North: 41.225333

GPS Coordinates West: 083.970333

Ground Bed Type: Local

Rated Volts: 60

Rated Amps: 40

Present Volts: 2.9

Present Amps: 2.6

Proposed Test Date: As needed

Companies Involved: Crossroads, KNG, Buckeye

Comments: The output will be increased in early 2016. This is a new installation to protect a segment of rural pipeline.

OCC Case 2014-16

Name: Bob Sperling

Email: bob_sperling@

Company: Ohio Gas Company

Phone: 419-630-2241

Rectifier Address: 3226 Lathrop Road

Rectifier City: Berkey

Rectifier County: Lucas

GPS Coordinates North: 41.674033

GPS Coordinates West: 083.857117

Ground Bed Type: Local

Rated Volts: 30

Rated Amps: 16

Proposed Test Date: As needed

Companies Involved: PEPL, ANR, Dome (Plains)

Comments: This unit will be energized in early 2016. This is a new installation to protect a segment of rural pipeline.

2013 Cases

OCC Case 2013-06

Name: Ned Gisel

Email: ned_gisel@

Company: Transcanada US Pipelines

Phone: 419-439-0594

Rectifier Address: 3-245 Co Rd "V"

Rectifier City: Liberty Center

Rectifier County: Henry

GPS Coordinates North: 41.47245

GPS Coordinates West: -83.93050

Ground Bed Type: Local

Rated Volts: 60

Rated Amps: 40

Present Volts: 14.4

Present Amps: 6.0

Companies involved: OGC*, Crossroads

Test Date: During CIS in summer of 2014

RECENTLY CLOSED CASES

OCC Case 2011-07 Article VI (h) 2 year status review – terminate if inactive

Name: Greg Schwenke

Email: gschwenke@

Company: MidValley Pipeline

Phone: 859-630-1823

Rectifier Address: 595 Buckeye Rd

Rectifier City: Lima

Rectifier County: Allen

GPS Coordinates North: 40,  42.3660

GPS Coordinates West: 84.  7.3849

Ground Bed Type: Other - Explain in Remarks

Rated Volts: 40

Rated Amps: 30

Present Volts: 4

Present Amps: 2.7

Proposed Test Date: to be determined

Companies Involved: Marathon*, DEOG-D*, BP*, TCO*, Buckeye*

Comments: under tank cp system in tank farm

OCC Case 2011-08 Article VI (h) 2 year status review – terminate if inactive

Name: Greg Schwenke

Email: gschwenke@

Company: MidValley Pipeline

Phone: 859-630-1823

Rectifier Address: 595 Buckeye Rd

Rectifier City: Lima

Rectifier County: Allen

GPS Coordinates North: 40.  42.3466

GPS Coordinates West: 84.  7,1613

Ground Bed Type: Other - Explain in Remarks

Rated Volts: 40

Rated Amps: 30

Present Volts: 9

Present Amps: 13.2

Proposed Test Date: to be determined

Companies Involved: Marathon*, DEOG-D*, BP*, TCO*, Buckeye*

Comments: under tank cp system Tank 91

OCC Case 2011-09 Article VI (h) 2 year status review – terminate if inactive

Name: Greg Schwenke

Email: gschwenke@

Company: MidValley Pipeline

Phone: 859-630-1823

Rectifier Address: 595 Buckeye Rd

Rectifier City: Lima

Rectifier County: Allen

GPS Coordinates North: 40.  42.4410

GPS Coordinates West: 84.  6.9511

Ground Bed Type: Other - Explain in Remarks

Rated Volts: 40

Rated Amps: 30

Present Volts: 9

Present Amps: 6.75

Companies Involved: Marathon*, DEOG-D*, Buckeye*, TCO*, BP*

Comments: under tank cp system Tank 97

COMPANY INDEX

AEP American Electric Power

ANR Trans Canada

ANTERO Antero Midstream

BP British Petroleum

BUC Buckeye Partners

BRM Blue Racer Midstream

CEI Cleveland Electric and Illuminating Company

COH Columbia Gas of Ohio

CPP Cleveland Public Power

DEOG-T Dominion East Ohio Gas – Transmission

DEOG-D Dominion East Ohio Gas – Distribution

DTI Dominion Transmission Interstate

DOME Dome Pipeline

DUKE Duke Energy

EPP Enterprise Products Partners

MID Mid-Valley

MPL Marathon Pipeline Company

MWE Mark West Energy

NCGT North Coast Gas Transmission

NGO National Gas & Oil (The Energy Cooperative)

NORCO Some portions were formally known as ARCO and/or TransMontaigne

OGC Ohio Gas Company

OOG Ohio Oil Gathering

REX Rockies Express Pipeline (Kinder Morgan)

SPECTRA Spectra Energy (Texas Eastern?)

SUN Sunoco Logistics

TCO Columbia Gas Transmission

TEP Tallgrass Energy Partners

TETLP Texas Eastern Product Pipeline Company - Enterprise

TGP Tennessee Eastern Transmission LP

UTI Utility Technologies International Corp

VEDO Vectren Energy Delivery Company

................
................

In order to avoid copyright disputes, this page is only a partial summary.