Ppmoe.dot.ca.gov



XE "49-3.02B(6)(c)_A10-19-18__2018" Page 1 of 4Section 49-3.02B(6)(c). Use for CIDH piling at least 24 inches in diameter and 5 feet in length.Add to section 49-3.02B(6)(c):The synthetic slurry must be one of the materials shown in the following table:MaterialManufacturerSlurryPro CDPKB INTERNATIONAL LLC735 BOARD ST STE 209CHATTANOOGA TN 37402(423) 266-6964Super MudPDS CO INC105 W SHARP STEL DORADO AR 71731(870) 863-5707Shore Pac GCVCETCO CONSTRUCTION DRILLING PRODUCTS2870 FORBS AVEHOFFMAN ESTATES IL 60192(800) 527-9948Terragel or Novagel PolymerGEO-TECH SERVICES LLC220 N. ZAPATA HWY STE 11A-449ALAREDO TX 78043(210) 259-6386BIG FOOTMATRIX CONSTRUCTION PRODUCTS50 S MAIN ST STE 200NAPERVILLE IL 60540(877) 591-3137POLY-BOREBAROID INDUSTRIAL DRILLING PRODUCTS3000 N SAM HOUSTON PKWY EASTHOUSTON TX 77032(877) 379-7412Use synthetic slurries in compliance with the manufacturer's instructions. Synthetic slurries shown in the above table may not be appropriate for a given job site.Synthetic slurries must comply with the Department's requirements for synthetic slurries to be included in the above table. The requirements are available from the Offices of Structure Design, P.O. Box 168041, MS# 9-4/11G, Sacramento, CA 95816-8041.SlurryPro CDP synthetic slurry must comply with the requirements shown in the following table:SlurryPro CDPQuality characteristicTest methodRequirementDensityMud weight (density),API RP 13B-1,section 4During drilling (pcf)≤ 67.0aBefore final cleaning and immediately before placing concrete (pcf)≤ 64.0aViscosityMarsh funnel and cup.API RP 13B-1, section 6.2During drilling (sec/qt)50–120Before final cleaning and immediately before placing concrete (sec/qt)≤ 70pHGlass electrode pH meter or pH paper6.0–11.5Sand content, percent by volumeSand,API RP 13B-1, section 9Before final cleaning and immediately before placing concrete (%)≤ 1.0NOTE: Slurry temperature must be at least 40 °F when tested.aIf authorized, you may use slurry in a salt water environment. The allowable density of slurry in a salt water environment may be increased by 2 pcf.Super Mud synthetic slurry must comply with the requirements shown in the following table:Super MudQuality characteristicTest methodRequirementDensityMud weight (density),API RP 13B-1,section 4During drilling (pcf)≤ 64.0aBefore final cleaning and immediately before placing concrete (pcf)≤ 64.0aViscosityMarsh funnel and cup.API RP 13B-1, section 6.2During drilling (sec/qt)32–60Before final cleaning and immediately before placing concrete (sec/qt)≤ 60pHGlass electrode pH meter or pH paper8.0–10.0Sand content, percent by volumeSand,API RP 13B-1, section 9Before final cleaning and immediately before placing concrete (%)≤ 1.0NOTE: Slurry temperature must be at least 40 °F when tested.aIf authorized, you may use slurry in a salt water environment. The allowable density of slurry in a salt water environment may be increased by 2 pcf.Shore Pac GCV synthetic slurry must comply with the requirements shown in the following table:Shore Pac GCVQuality characteristicTest methodRequirementDensityMud weight (density),API RP 13B-1,section 4During drilling (pcf)≤ 64.0aBefore final cleaning and immediately before placing concrete (pcf)≤ 64.0aViscosityMarsh funnel and cup.API RP 13B-1, section 6.2During drilling (sec/qt)33–74Before final cleaning and immediately before placing concrete (sec/qt)≤ 57pHGlass electrode pH meter or pH paper8.0–11.0Sand content, percent by volumeSand,API RP 13B-1, section 9Before final cleaning and immediately before placing concrete (%)≤ 1.0NOTE: Slurry temperature must be at least 40 °F when tested.aIf authorized, you may use slurry in a salt water environment. The allowable density of slurry in a salt water environment may be increased by 2 pcf.Terragel or Novagel Polymer synthetic slurry must comply with the requirements shown in the following table:Terragel or Novagel PolymerQuality characteristicTest methodRequirementDensityMud weight (density),API RP 13B-1,section 4During drilling (pcf)≤ 67.0aBefore final cleaning and immediately before placing concrete (pcf)≤ 64.0aViscosityMarsh funnel and cup.API RP 13B-1, section 6.2During drilling (sec/qt)45–104Before final cleaning and immediately before placing concrete (sec/qt)≤ 104pHGlass electrode pH meter or pH paper6.0–11.5Sand content, percent by volumeSand,API RP 13B-1, section 9Before final cleaning and immediately before placing concrete (%)≤ 1.0NOTE: Slurry temperature must be at least 40 °F when tested.aIf authorized, you may use slurry in a salt water environment. The allowable density of slurry in a salt water environment may be increased by 2 pcf.BIG-FOOT synthetic slurry must comply with the requirements shown in the following table:BIG-FOOTQuality characteristicTest methodRequirementDensityMud weight (density),API RP 13B-1,section 4During drilling (pcf)≤ 64.0aBefore final cleaning and immediately before placing concrete (pcf)≤ 64.0aViscosityMarsh funnel and cup.API RP 13B-1, section 6.2During drilling (sec/qt)30–125Before final cleaning and immediately before placing concrete (sec/qt)55-114pHGlass electrode pH meter or pH paper8.5–10.5Sand content, percent by volumeSand,API RP 13B-1, section 9Before final cleaning and immediately before placing concrete (%)≤ 1.0NOTE: Slurry temperature must be at least 40 °F when tested.aIf authorized, you may use slurry in a salt water environment. The allowable density of slurry in a salt water environment may be increased by 2 pcf.POLY-BORE synthetic slurry must comply with the requirements shown in the following table:POLY-BOREQuality characteristicTest methodRequirementDensityMud weight (density),API RP 13B-1,section 4During drilling (pcf)62.8-65.8aBefore final cleaning and immediately before placing concrete (pcf)62.8-64.0aViscosityMarsh funnel and cup.API RP 13B-1, section 6.2During drilling (sec/qt)50–80Before final cleaning and immediately before placing concrete (sec/qt)50-80pHGlass electrode pH meter or pH paper7.0–10.0Sand content, percent by volumeSand,API RP 13B-1, section 9Before final cleaning and immediately before placing concrete (%)≤ 1.0NOTE: Slurry temperature must be at least 40 °F when tested.aIf authorized, you may use slurry in a salt water environment. The allowable density of slurry in a salt water environment may be increased by 2 pcf. ................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download