Downloads.rxlps.com



Do not plug-in the USB plug for the Ingenico sig pad to the PC. Only plug in the power plug.At the system info screen, make sure that the communication type is set to USB-CDC. It must be set to this type BEFORE installing the USB drivers/OPOS! Otherwise the device will not work properly.Configure iSC480 Device for USB-CDC ? On the device, press and hold the ‘Minus’ and ‘Clear’ keys to reboot the device. ? If this fails to reboot the device, power it off and back on again. ? Once on the UPOS Interface Application screen, press [2], [6], [3], [4], and then press enter. ? Wait for a second screen to display and press the ‘Plus’ key. ? This will take you to the Functions menu ? Tap TDA on the menu ? Press Enter 3 times (Configuration > Communication > Select Comm. Type) ? Press the Minus key until USB<>SerialConv is selected and hit Enter ? Press Cancel 3 times and hit the Minus key to ‘Yes’ and hit Enter to save the config and reboot. ? Once back to the UPOS Interface Application screen, verify that the last line reads ‘USB-CDC’ The correct UIA version should be loaded: 9.0.4.3025.Run the file IngenicoUSBDrivers_2.60_setup.exe. Note the screenshots pertain to the older 1.5 driver version but the steps are the same.Click NEXT.Click NEXT.On this screen, you will need to check in the “Force COM Port Feature enabled” option as well as type in the number 8 in the bottom left-most input box. Then click NEXT.Click NEXTClick Install to begin the final installation of the driver. This may take up to 2 minutes to finish. Please note that during the installation, Windows will prompt at the bottom right-hand corner “Device driver software was not successfully installed”. Please disregard this message as further configurations must take place. Click Finish. An Ingenico splash screen will then appear for the “OPOS for the Ingenico Telium2” software installation. Run the file OPOS for the Ingenico Telium2 v1.4.21.2.exe. Click NEXT. Accept the ULA and then click NextChoose the Complete setup type and click NextChoose Allow everyone to configure Telium 2 terminals and click NextClick INSTALL.Click FINISH.Once the drivers and OPOS are installed successfully, plug in the USB into the PC.Next, configuring the device communication settings is required in order to allow PayLINK to communicate with it via the Ingenico OPOS drivers. Open the Start Menu and choose Control Panel. In Windows 7, if your screen looks like the following, click the Category dropdown box towards the upper right-hand corner of the Control Panel dialog and select Small icons.By changing to Small icons, your Control Panel will now look like the followingNext, the Control Panel should list several more options. Within those options is Ingenico iSeries Telium2. Click on that option and a dialogue box should appear. Once in the dialogue within the General tab, there should be a List dropdown box that by default will say Telium2. You will need to select the Ingenico device in which you’re using. Screenshots below indicate ISC250. SELECT iSC480 from the drop down menu. Click the Apply button to allow the setting changes to take place. Navigate to the Connection tab of the dialogue. There you will notice an option called Device Connection Type which by default may be set to USB. This option will need to be switched to Serial instead. Once the option for Serial is selected, a series of fields will then appear. For Comm Port dropdown box, the COM1 option will need to be changed to COM8 as specified in the Ingenico USB Drivers Package installation from earlier. After the change, click the Apply button and then click OK. You may get the following popup dialogChoose “This control panel works correctly”. For verification purposes, you may view the Device Manager and navigate under the ports hierarchy and check for “Ingenico iSCxxx Comm Port.”Run the file SETUP_OPOSTestApp_1.4.21.2.exe. Follow all prompts to complete install.Install the latest approved PayLINK version.Open the PayLink Settings Editor and navigate to the Hardware tab. Configure Pin Pad, Card Reader, and Sig Cap for iSC480. Click APPLY. PayLINK will warn that the service needs to be restarted. Click YES.Click DOWNLOAD FORMS after the service is restarted. Click OK. NOTE: If it fails to download the forms to the pad, make sure the PayLINK service is started and that the FORMS.tgz file exists in the C:\Program Files (x86)\Paylink\Bin\Forms\iSC480\ directory.Click DONE if you are done configuring PayLINK. ................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download