ELECTRICAL SYMBOLS LEGEND ABBREVIATIONS LEGEND - BidNet

ELECTRICAL SYMBOLS LEGEND

OUTLETS

SINGLE RECEPTACLE (120 VOLT) DUPLEX RECEPTACLE EMERGENCY RECEPTACLE DOUBLE DUPLEX RECEPTACLE F FLUSH FLOOR BOX S SURFACE FLOOR BOX SPECIAL EQUIPMENT RECEPTACLE TELEPHONE OUTLET DATA OUTLET TELEPHONE / DATA OUTLET PP POWER POLE J JUNCTION BOX J WALL JUNCTION BOX J PULL (JUNCTION) BOX J UNDERFLOOR JUNCTION BOX CEILING MOUNTED WIFI

SWITCHES

SINGLE-POLE SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH SWITCH WITH PILOT LIGHT THERMAL OVERLOAD SWITCH MANUAL MOTOR SWITCH KEY SWITCH TIME SWITCH D DIMMER SWITCH

MECHANICAL

SINGLE PHASE MOTOR THREE PHASE MOTOR RESISTANCE HEATER, KW SHOWN PIPE TRACE HEATER ELECTRIC UNIT HEATER WH ELECTRIC WATER HEATER

NURSE CALL

NCC M P

E CB A L B1 B2

SRS S DS

NURSE CALL CONTROLLER MASTER STATION EMERGENCY PULL STATION

EMERGENCY PUSH STATION CODE BLUE STATION PENDENT INTERFACE BED / LIGHT INTERFACE SINGLE BED STATION DUAL BED STATION DOME LIGHT STAFF REGISTER STATION STAFF STATION DUTY STATION

DESIGNATIONS

X DEMOLITION NOTE

X PLAN NOTE

X

ADDENDUM NOTE

FIXTURES

LIGHT FIXTURE

TVSS

STRIP FIXTURE

VFD

EMERGENCY LIGHT FIXTURE

T

IN-GRADE LIGHT FIXTURE

SPOTLIGHT (number of heads shown)

EXIT SIGN (face & direction as shown)

WALL MOUNT LIGHT FIXTURE

CEILING LIGHT FIXTURE

TRACK & FIXTURE

STREET TYPE POLE FIXTURE

POLE MOUNTED LIGHT FIXTURE

EXTERIOR WALL MOUNT LIGHT FIXTURE CT

WALLPACK LIGHT FIXTURE

G

TT

SPECIAL PURPOSE LIGHT FIXTURE

HIGH BAY LIGHT FIXTURE

EMERGENCY EGRESS LIGHT FIXTURE

WW

(number of heads shown)

TS

DOCK LIGHT FIXTURE

CIRCUITRY and RACEWAYS

CONDUIT INSTALLED (by E.C.)

CONDUIT INSTALLED (by others)

T

CONDUIT STUB UP CONDUIT STUB DOWN 1,3 HOME RUN (with circuit numbers)

H PC

TC

END OF CONDUIT RUN

3

END OF CONDUIT RUN, CAP AND STAKE

"CONDUIT RUN CONTINUES" INDICATION

OR

FLEXIBLE PIGTAILS/CONNECTIONS

IC

WM WIREMOLD AS SPECIFIED

PM PLUGMOLD AS SPECIFIED

BD BUS DUCT

OS1

UFD UNDERFLOOR DUCT

SOUND and SIGNAL

OS2

S SPEAKER

WALL MOUNTED SPEAKER

OS3

WALL MOUNTED SPEAKER / CLOCK COMBO

SINGLE FACE CLOCK OS4

DUAL FACE CLOCK

VI AV

B V B C

M I C

DC M B KP

SSCP

VIDEO INPUT AUDIO / VIDEO INPUT BELL VOLUME CONTROL BUZZER CHIME TELEVISION OUTLET MICROPHONE OUTLET INTERCOM OUTLET CAMERA DOOR CONTACT MOTION DETECTOR BEAM DETECTOR KEY PAD SECURITY SYSTEM CONTROL PANEL CCTV CONTROL PANEL

CR CARD READER

SS STUDENT STATION

AS ADMINISTRATION STATION

TS TEACHER STATION G GLASS BREAK

OS5 OC

T

H

F/S

F

FACP ANN EOL

GENERAL ELECTRICAL NOTES

DH FC

F

V FCPS

M C

SERVICE and EQUIPMENT

TRANSIENT VOLTAGE SURGE SUPPRESSION VARIABLE FREQUENCY DRIVE TRANSFORMER DISCONNECT SWITCH (fuse size shown) MAGNETIC STARTER (BY x/C U.O.N.) COMB. STARTER (BY x/C U.O.N.) PANELBOARD, SURFACE MOUNTED PANELBOARD, FLUSH MOUNTED WEATHERHEAD UTILITY METER, AS REQUIRED CURRENT TRANSFORMERS GENERATOR, KW SHOWN TELEPHONE TERMINAL BOARD GROUND CONNECTION PER N.E.C. WIREWAY TRANSFER SWITCH ENCLOSED CIRCUIT BREAKER CAPACITOR

CONTROL

THERMOSTAT HUMIDISTAT PHOTOCELL (voltage as required) TIME CLOCK (24 hour U.O.N.) PUSHBUTTON STATION (number of buttons indicated) CONTROL TRANSFORMER LIGHTING CONTACTOR IRRIGATION CONTROLLER (120 volt xxVA connection by x/C)

WALL MOUNT DUAL TECHNOLOGY SENSOR SENSOR SWITCH WV-PDT-16 SERIES

OCCUPANCY SENSOR / PHOTOCELL SENSOR SWITCH CMR-PC-ADC SERIES

8/75$621,&6(1625&,5&8,7 SENSOR SWITCH CMR-PDT-10-2P

8/75$621,&6(162564)7 SENSOR SWITCH CMR-PDT-10

8/75$621,&6(162564)7 SENSOR SWITCH CMR-PDT SERIES

SWITCH STYLE OCCUPANCY SENSOR SENSOR SWITCH WSD-PDT SERIES

POWER PACK SENSOR SWITCH MP20 SERIES

DIGITAL TIME SWITCH WATT STOPPER TS-400

FIRE ALARM

SMOKE DETECTOR HEAT DETECTOR DUCT SMOKE DETECTOR DUCT SMOKE DETECTOR HORN HORN & LIGHT SPEAKER SPEAKER & LIGHT PULL STATION FIRE ALARM CONTROL PANEL ANNUNCIATOR PANEL END OF LINE DEVICE REMOTE INDICATING LIGHT, WALL MTD. REMOTE INDICATING LIGHT, CLG. MTD. MAGNETIC DOOR HOLDER FIREFIGHTER COMMUNICATION JACK FLOW SWITCH (furnished by FP/C) TAMPER SWITCH (furnished by FP/C) VISUAL ONLY UNIT FIRE CONTROL POWER SUPPLY MONITOR MODULE CONTROL MODULE CARBON MONOXIDE DETECTOR

ABBREVIATIONS LEGEND

A AC ACUAFF AHJ AHUAIC AS ATS

BBC BLDG

CHLRCND (C) CKT CKT BKR CTCUCUH-

DFUDISC DWG DWH-

EBBEC EFEM EMT EWC EXIST (E)

FLA FLEX FLR FLUOR FSES F/S FU-

AMPS ABOVE COUNTER AIR CONDITIONING UNIT ABOVE FINISHED FLOOR AUTHORITY HAVING JURISDICTION AIR HANDLING UNIT AMPS INTERUPTING CAPACITY ABOVE SHELF AUTOMATIC TRANSFER SWITCH

BOILER BELOW COUNTER BUILDING

CHILLER CONDUIT CIRCUIT CIRCUIT BREAKER COOLING TOWER CONDENSING UNIT CABINET UNIT HEATER

DUCT FURNACE DISCONNECT DRAWING DOMESTIC WATER HEATER

ELECTRIC BASEBOARD ELECTRICAL CONTRACTOR EXHAUST FAN EMERGENCY ELECTRICAL METALLIC TUBING ELECTRIC WATER COOLER EXISTING

FULL LOAD AMPS FLEXIBLE CONDUIT FLOOR FLUORESCENT FOOD SERVICE EQUIP. SUPPLIER FIRE/SMOKE FURNACE

GC GFI GND

HHID HOA HP HR HVAC

IG IMC

JB

LC LT LTG LT FLEX

MAX MC MCC MIN MLO MT MTD MTG MUAU-

NC NIC NL NO NTS

GENERAL CONTRACTOR GROUND FAULT INTERUPTER GROUND

HUMIDIFIER HIGH INTENSITY DISCHARGE HAND-OFF-AUTO SELECTOR SWITCH HORSEPOWER HOUR HEATING/VENTILATING/AIR CONDITIONING

ISOLATED GROUND INTERMEDIATE METAL CONDUIT

JUNCTION BOX

LIGHT CONTROL LIGHT LIGHTING LIQUID TIGHT FLEXIBLE METAL CONDUIT

MAXIMUM MECHANICAL CONTRACTOR MOTOR CONTROL CENTER MINIMUM MAIN LUG ONLY MOUNT MOUNTED MOUNTING MAKE-UP AIR UNIT

NORMALLY CLOSED NOT IN CONTRACT NIGHT LIGHT NORMALLY OPEN NOT TO SCALE

P PPB PNL PRVPVC PWR

RECEPT RGC RTU-

SFSPEC SW SWBD

TCC TR TS TYP

UF UHUL UNO

V VL

W W/ W/O WP

XFMR

POLE PUMP PULL BOX PANEL POWER ROOF VENTILATOR POLY VINYL CLORIDE POWER

RECEPTACLE RIGID GALVANIZED STEEL CONDUIT ROOF TOP UNIT

SUPPLY FAN SPECIFICATIONS SWITCH SWITCHBOARD

TEMPERATURE CONTROL CONTRACTOR TAMPER PROOF RECEPTACLE TAMPER PROOF SWITCH TYPICAL

UNDER FLOOR UNIT HEATER UNDERWRITERS' LABORATORIES, INC. UNLESS NOTED OTHERWISE

VOLTS VERIFY LOCATION WITH OWNER

WATTS WITH WITHOUT WEATHER PROOF

TRANSFORMER

TYPE MANUFACTURER

CATALOG NO.

LIGHTING FIXTURE SCHEDULE

DESCRIPTION AND COMMENTS

BALLAST INFO

FIXTURE MOUNTING

HEIGHT

LAMPS

date

checked by drawn by consultant

group

6240 W Mt Hope Lansing, MI 48917 t. 517-323-0577 f. 517-323-0570

file no.

084/17314.CDP

index no.

67025

contract order no. architect job no.

2017-066

sheet no.

DIVISION 26 ELECTRICAL SPECIFICATIONS

DESCRIPTION OF WORK WORK SHALL INCLUDE BUT NOT NECESSARILY BE LIMITED TO THE FOLLOWING:

1. WIRING METHODS. 2. DEVICES. 3. LIGHTING. 4. TEMPORARY POWER AND LIGHTING.

STANDARDS MATERIALS AND EQUIPMENT SHALL CONFORM TO THE REQUIREMENTS OF MBC, NEC, MIOSHA, NFPA, U.L., NEMA, A.D.A., AND RESPECTIVE PUBLICATIONS AND OTHER REQUIREMENTS SPECIFIED BELOW. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH RECOMMENDATIONS OF THE MANUFACTURER.

CODES AND ORDINANCES COMPLY WITH ALL CODES AND ORDINANCES. BIDDERS SHALL INFORM THEMSELVES OF CODE REQUIREMENTS.

PERMITS, INSPECTION FEES, AND CODES THE CONTRACTOR SHALL OBTAIN AND PAY ALL PERMIT AND INSPECTION FEES. FINAL INSPECTION CERTIFICATES BY THE LOCAL ELECTRICAL INSPECTOR AND FIRE MARSHAL SHALL BE OBTAINED BY THE CONTRACTOR AND TURNED OVER IN DUPLICATE TO THE OWNER.

SUBMISSIONS SUBMIT PRODUCT DATA, SHOP DRAWINGS, WIRING DIAGRAMS, AND DESCRIPTIVE LITERATURE ON ALL MATERIALS AND EQUIPMENT. MAKE SUBMITTALS WITHIN THIRTY (30) DAYS AFTER THE SIGNING OF THE CONTRACT. SHIPMENT SHALL NOT BE RELEASED UNTIL DRAWINGS AND LITERATURE HAVE BEEN FINALLY APPROVED.

AS-BUILTS - OPERATION & MAINTENANCE MANUALS PROVIDE FOR EACH SYSTEM AND EQUIPMENT AS SPECIFIED FOR USE BY OPERATION AND MAINTENANCE PERSONNEL. THE OPERATING INSTRUCTIONS SHALL INCLUDE:

x WIRING DIAGRAMS, CONTROL DIAGRAMS, AND CONTROL SEQUENCE FOR EACH SYSTEM AND ITEM OF EQUIPMENT. x START-UP, PROPER ADJUSTMENT, OPERATING, LUBRICATION, AND SHUTDOWN PROCEDURES. x SAFETY PRECAUTIONS x THE PROCEDURE IN THE EVENT OF EQUIPMENT FAILURE x OTHER ITEMS OF INSTRUCTION AS RECOMMENDED BY THE MANUFACTURER OF EACH SYSTEM OR ITEM OF EQUIPMENT.

IDENTIFICATION OF SYSTEMS OPERATING INSTRUCTIONS: PRINT OR ENGRAVE INSTRUCTIONS AND FRAME UNDER GLASS OR APPROVED LAMINATED PLASTIC. POST INSTRUCTIONS IN VIEW OF EQUIPMENT. PROVIDE WEATHER RESISTANT MATERIALS FOR EXTERIOR APPLICATIONS.

EQUIPMENT: PROVIDE NAMEPLATE FOR ALL EQUIPMENT IT SHALL BE A SELF-ADHESIVE, ENGRAVED, LAMINATED ACRYLIC OR MELAMINE LABEL. PROVIDE ADHESIVE BACK, WITH WHITE LETTERS ON A DARK GRAY BACKGROUND. MINIMUM LETTER HEIGHT SHALL BE 3/8-INCH.

WARNING SIGNS: PROVIDE A SELF-ADHESIVE WARNING LABEL THAT IS FACTORY PRINTED, MULTI-COLOR, PRESSURE SENSITIVE,

$'+(6,9(/$%(/&203/ ................
................