NABL India



CHEMICAL TESTINGLOCATION 1I.TEXTILE1.Textile Materials/AccessoriesTensile Strength-Strip testBS EN ISO 13934-1:2013EN ISO 13934-1:2013ISO 13934-1:2013ASTM D5035:2015Tensile Strength-Grab testBS EN ISO 13934-2:2014EN ISO 13934-2:2014ISO 13934-2:2014ASTM D5034-2017Tear strength-By Elmendorf ApparatusBS EN ISO 13937-1:2000EN ISO 13937-1:2000ISO 13937-1:2000ASTM D 1424:09 (2013)Tear Strength-Single Rip (Single tear)BS EN ISO 13937-2:2000ISO 13937-2:2000ASTM D2261:2017Seam StrengthBS EN ISO 13935-2:2014ASTM D 1683::2018Resistance to Seam SlippageBS EN ISO 13936-1:2004BS EN ISO 13936-2:2004 ASTM D 434-95BS 3320:1988Determination of Elasticity of the fabricsBS 4952:1992 straight specimens(2.1 to 2.4)BS EN 14704-1:2005Mass per unit area (Weight)ISO 3801:(1977)BS EN 12127:1998EN 12127:(1998)ASTM D3776:09a (2017)Yarn Number(Based on short length the specimens)IHTM PHY01(Issue no-1/27.07.2016)Warp & Filling/Count-Woven fabric-Knitted fabricASTM D3775:(2017)EN 1049-2:(1994)BS EN 1049-2:(1994)ASTM D3887:2008BS 5441 (1988)Fabric WidthASTM D 3774-1996 (Reapproved 2016)Water AbsorbencyAATCC 79:2014Determination of the abrasion resistance of fabrics by the Martindale methodBS EN ISO 12947-2:2016EN ISO 12947-3:2016ISO 12947-4:2016ASTMD496612(REAPPROVED2016)Determination of fabricpropensity to surfacefuzzing and to pillingBS EN ISO 12945-2:(2000)EN ISO 12945-2:(2000)ISO 12945-2:(2000)ASTM D4970-2010BS EN ISO 12945-1:(2001)EN ISO 12945-1:(2000)ISO 12945-1:(2000)Bursting StrengthBS EN ISO 13938-2:1999EN ISO 13938-2:1999ISO 13938-2:1999ASTM D3786:2018Determination of sharp points ( under a force of 4.45N(1 pound)ASTM F 963:2011Section 4.9 16 CFR 1500.48EN 71-1:2011, Amd 3:2014(Sec 8.12)Determination of sharp edges (under a force of 8.90 N(2 pound)ASTM F 963:2011Section 4.7 16 CFR 1500.49EN 71-1:2011, Amd 3:2014(Sec 8.11)Determination of small parts torque test up to 9kg-cm (up to 7.8 inch pounds)ASTM F 963:2011Section 8.8/16 CFR 1500.51-53/EN 71-1:2011, Amd 3:2014 (Sec 8.3)Determination of small parts tension test ASTM F 963:2011Section 8.9 16 CFR 1500.51-53EN 71-1:2011, Amd 3:2014 (Sec 8.4)Small parts-choking hazard test (small part cylinder of 31.7 mm inner diameter)ASTM F 963:2011Section 4.6 16 CFR 1501EN 71-1:2011, Amd 3:2014 (Sec 8.2)Color Fastness to Washing with soap or soap sodaBS EN ISO 105-C10:2007EN ISO 105 C10:2007ISO 105-C10:2006Color Fastness to Laundering:AcceleratedAATCC 61:2013Color Fastness to domestic and commercial laundering using non Phosphate reference actual def. in corpora ting a low Temperature washBS ISO 105-C08:2010EN ISO 105 C08:2010ISO 105 C08:2010Color Fastness to domestic and commercial laundering oxidative bleach response using a non-phosphate reference def. in corpora ting a low temperature bleach activatorBS ISO 105-C09:2003Color fastness to domestic and commercial launderingBS EN ISO 105-C06:2010EN ISO 105-CO6:2010ISO 105-CO6:2010Color Fastness to Dry cleaningBSEN ISO 105-D01:2010EN ISO 105 D01:2010ISO105 D01:2010AATCC 132:2013Color Fastness to WaterBS EN ISO 105-E01:2013EN ISO 105-E01:2013ISO 105-E01:2013AATCC 107:2013/GB/T 5713:1997Color Fastness to Sea waterBS EN ISO 105-E02:2013EN ISO 105-E02:2013ISO 105-E02:2013AATCC 106:2013Color Fastness to Chlorinated water(Swimming-Pool Water)BS EN ISO 105-E03:2010EN ISO 105-E03:2010ISO 105-E03:2010AATCC 162:2013Color Fastness to PerspirationBS EN ISO 105-E04:2013EN ISO 105-E04:2013ISO 105-E04:2013AATCC 15:2013GB/T 3922:1995Color Fastness to Water spottingBS EN ISO 105-E07:2010EN ISO 105 E07:2010ISO 105 E07:2010AATCC 104:2014Color Fastness to Bleaching:Hypo ChloriteISO 105 N01:1993Color Fastness to PowderedNon-Chlorine Bleach in home launderingAATCC 172:2016Color Fastness to Organic solventsBS EN ISO 105-X05:1997EN ISO 105-X05:1997ISO 105 X05:1994Color Fastness to Crocking/RubbingBS EN ISO 105:X12:2002ISO 105:X12:2016AATCC 8:2013GB/T 3920:2008Color Fastness to SalivaDIN 53160-1:2010DIN 53160-2:2010LMBG 82.10-1:1985GB/T 18886:2002Dye transfer in storage; fabric to fabricAATCC 163-2013Color Fastness to Sodium hypochlorite bleach in home launderingAATCC 188-2010Dimensional stability to domestic washed and dryingBS EN 26330:1994EN 26330:1993BS EN ISO 6330:2012EN ISO 6330:2012ISO 6330:2012Determination of dimensional change in washing and dryingBS EN ISO 5077:2008EN 25077:2008ISO 5077:2007Preparation, marking and measuring of fabric specimens and garment in test for determination of dimensional changeBS EN ISO 3759:2011EN ISO 3759:2011ISO 3759:2011Dimensional change of fabric after home launderingAATCC 135:2015Dimensional change of garment after home launderingAATCC 150:2018Determination of spirality after laundering Percentage of wales spirality change in knitted garmentISO 16322-1:2005Determination of spirality after laundering Woven and knitted fabricISO 16322-2:2005Determination of spirality after laundering Woven and knitted fabricISO 16322-3:2005Determination of Skewness change in fabric and garment twist resulting from automatic home laundering AATCC 179:2012Determination of pH Value AATCC 81:2016ISO 3071:2005Determination of free and hydrolyzed Formaldehyde (UV Spectrophotometer)JIS L 1041:2005BS EN ISO 14184-I:2011Determination of released Formaldehyde(UV Spectrophotometer)AATCC 112:2014BS EN ISO 14184-2:201135 LMBG 82.02.1-1985Determination of 4-aminoazobenzene 64 LFGB 82.02.9-2006 GB/T 23344-2009Determination of Fiber Analysis-QualitativeAATCC 20:2013Determination of Fiber Analysis-QuantitativeAATCC 20 A:2014Determination of Binary Fiber Mixture-QuantitativeISO 1833-1:2006 + Cor 1:2009ISO 1833-3, 4, 6 to 16:2006BSEN ISO 1833-1:2011Determination of Ternary Fiber Mixture-QuantitativeISO 1833-2:2006BSEN ISO 1833-2:2011Determination of Azo dye on Textile 1. 4-aminodiphenyl/Biphenyl-4-ylamine2. Benzidine3. 4-chlor-o-toluidine4. 2-naphthylamine5.o-aminoazotoluene/4-o-tolylazo-o-toluidine/4-amino-2',3-di methylazobenzene6. 2-amino-4-nitrotoluol/5-nitro-o-toluidine7. p-chloranilin/4-chloroaniline8.2,4-diaminoanisol/4-methoxy-m-phenylenediamine9.4,4'-diaminodiphenylmethane/4,4-methylenedianiline10. 3,3'-dichlorobenzidine/3,3'dichlorobiphenyl-4,4'-ylenediamine11. 3,3'-dimethoxybenzidine/o-dianisidine12. 3,3'-dimethybenzidine/4,4'-bi-o-Toluidine13. 3,3'-dimethyl-4,4'-diaminodipenylmethane/4,4'-methylenedi-o-toluidine14. p-cresidin/6-methoxy-m-toluidine15. 4,4'-methylen-bis-(2-chloro-aniline)/2,2'-dichloro-4,4'methyl ene-dianiline16. 4,4'-oxydianiline17. 4,4'-thiodianiline18. o-toluidine/2-aminotoluene19. 2,4-toluylendiamine/4-methyl-m-phenylenediamine20. 2,4,5-trimethylaniline21. 4-aminoazobenzene22. o-anisidine/2-methoxyaniline23. 2,4-Xylidine24. 2,6-XylidineBS EN 14362-I:201235 LMBG 82.02-2:199835 LMBG B82.02-4:1:1998EN 14362-I:2012 EN 14362-3:2012 GB/T17592:2011 Migration of Certain Elements EN 71 Part-3:2013+Amd 1:2014Lead(pb),. Aluminum(Al), Manganese, Strontium, ZincCadmium(Cd), Antimony, cobalt, Mercury, Selenium, Tin, CopperArsenic, Barium, Boron, Chromium( Combined)NickelDetermination of PCP LMBG 82.02-08:2001 Determination of OPP/TeCP/TCPIn house 12-LO-S0865Based on LMBG 82.02-08:2001(Issue no-1/ 25.07.16)Determination of nickel content by flame atomic absorption spectrophotometryEN 1810:1998 BSEN 1810:1998 Nickel release from products intended to come into direct and Prolonged contactBSEN 1811:2011 Detection of PVC (Poly Vinyl chloride)IHTM-CHEM-01 (Issue no-1/01.08.2016)Screening test for nickel releasePDCR 12471:2002 Phthalates in Toys and Childcare Articles1.Dibutyl phthalate (DBP)2.Benzyl Butyl phthalate (BBP)3.Bis 2 ethyl hexyl phthalate(DEHP)4.Di n-octyl phthalate (DNOP)5.Diiso nonyl phthalate (DINP)6.Diiso decyl phthalate (DIDP)7.Diiso butyl phthalate (DIBP)8.Dicyclohexyl phthalate(DCHP)9.Dimethyl phthalate(DMP)10.Diethyl phthalate(DEP)11.Di iso heptyl pthalate(DIHP)12.Bis 2methoxyethyl pthalate(DMEP)13.Di n hexyl pthalate(DnHP)14.Di un decyl pthalate(DUP)15.Diheptyl Phthalate16.Diisopentylphthalate(DIPP)17.Di n pentylphthalate(DNPP)18.n-pentyl-isopentyl phthalate(nPIPP)(CPSC-CH-C1001-09.3 April 1, 2010)(CPSIA Title 1 Section108(CPSC-CH-C1001-09.3 April 1, 2010) BSEN 14372:2004:Clause 6.3.2BSEN 15777:2009BSEN ISO 14389:2014 Determination of Chlorinated Organic Carriers1) 2-Chlorotoluene2) 3-Chlorotoluene3) 4-Chlorotoluene4) 2,3-Dichlorotoluene5) 2,4-Dichlorotoluene6) 2,5-Dichlorotoluene7) 2,6-Dichlorotoluene8) 3,4-Dichlorotoluene9) 2,3,6-Trichlorotoluene10) 2,4,5-Trichlorotoluene11) Pentachlorotoluene12) 1,2-Dichlorobenzene13) 1,3-Dichlorobenzene14) 1,4-Dichlorobenzene15) 1,2,3-Trichlorobenzene16) 1,2,4-Trichlorobenzene17) 1,3,5-Trichlorobenzene18) 1,2,3,4-Tetrachlorobenzene19) 1,2,3,5-Tetrachlorobenzene20) 1,2,4,5-Tetrachlorobenzene21) Pentachlorobenzene22) HexachlorobenzeneDIN 54232:2010Total Lead content in Substrate for metal children’s products including children’s metal jewelryASTM E1645-2001ASTM E1613-2012CPSC-CH-E1001-08.3 2012Health Canada Method C-02.4:2011 Total Lead content in Substrate for Non metal children’s products including children’s metal jewelryASTM E1645-2001ASTM E1613-2012CPSC-CH-E1002-08.3 2012Health Canada Method C-02.3:2011Total Lead content in Paint and other Similar Surface coatings including children’s metal jewelerASTM E1645-2001ASTM E1613-2012CPSC-CH-E1003-09.1 2011 Health Canada Method C-02.2:2011Determination of Dimethyl Formamide (DMFo)CEN/ISO/TS/16189:2013Polycyclic Aromatic Hydrocarbons (PAHs)AfPS GS 2014:01 PAKISO/TS 16190:2013ZEK 01.2-2008Organo Tin CompoundsTributyltin (TBT)Dibutyltin (DBT)Monobutyl tin (MBT)Tetrabutyl tin (TeBT)Triphenyl tin (TPhT)Mono n-octyl tin (MOT)Di-n-octyl tin (DOT)Tri-cyclohexyl tin (TCyHT)Tri octyl tin (TOT)Tri-n-propyl tin (TPrT)Mono Phenyl tin (MPhT)Di Phenyl tin (DPhT)Methyl tinDi-n-propyl tin (DPrT)Di Heptyl tinDi Methyl tinTri Methyl tinISO/TS 16179:2012Color Fastness to Artificial Light (Xenon Arc)BS EN ISO 105-B02:2014EN ISO 105-B02:2014ISO 105-B02:2014AATCC 16.3:2014Color Fastness to Phenolic yellowingBS EN ISO 105-X 18:2007II.LEATHERS & LEATHER PRODUCT1.Leathers & Leathers AccessoriesCadmium Extractability from children’s metal Jewelry CPSC-CH-E1004-11 February 03, 2011Determination of Dimethyl Fumarate in TextilesCEN ISO/TS 16186:2012, EEC Directive 2009/251/EC:2009Determination of cadmium wet decomposition methods for PlasticsEN 1122:2001Determination of Dimethyl Formamide (DMFo)CEN/ISO/TS/16189:2013Determination of Heavy metalsPb, Cd, Sb, Ba, Cr, Se, HgEN 71 Part-3:2013+Amd 1:2014ASTME1613:(2012)BS EN ISO 17072-1:2011EN 71 Part-3:2013+Amd 1:2014 With reference to(PDCR 13695-1:2000PDCR 13695-2:2004BS EN ISO 17072-2:2011ASTM F963-2011)CPSC-CH-E1001-08.3 2012/CPSC-CH-E1002-08.3 2012/CPSC-CH-E1003-09.1 2011Determination of pH ValueBSEN ISO 4045:2008ASTM D2810-2013Determination of FormaldehydeISO 17226-2:2008Determination of Azo dye in Leather1. 4-aminodipheny/Biphenyl-4-ylamine2. Benzidine3. 4-chlor-o-toluidine4. 2-naphthylamine5. o-aminoazotoluene/4-o-tolylazo-o-toluidine/4-amino-2',3-di methylazobenzene6. 2-amino-4-nitrotoluol/5-nitro-o-toluidine7. p-chloranilin/4-chloroaniline8. 2,4-diaminoanisol/4-methoxy-m-phenylenediamine9. 4,4'-diaminodiphenylmethane/4,4-methylenedianiline10. 3,3'-dichlorobenzidine/3,3'dichlorobiphenyl-4,4'-ylenediamine11. 3,3'-dimethoxybenzidine/o-dianisidine12. 3,3'-dimethybenzidine/4,4'-bi-o-Toluidine13. 3,3'-dimethyl-4,4'-diaminodipenylmethane/4,4'-methylenedi-o-toluidine14. p-cresidin/6-methoxy-m-toluidine15. 4,4'-methylen-bis-(2-chloro-aniline)/2,2'-dichloro-4,4'methyl ene-dianiline16. 4,4'-oxydianiline17. 4,4'-thiodianiline18. o-toluidine/2-aminotoluene19. 2,4-toluylendiamine/4-methyl-m-phenylenediamine20. 2,4,5-trimethylaniline21. 4-aminoazobenzene22. o-anisidine/2-methoxyaniline23. 2,4-Xylidine24. 2,6-Xylidine35 LMBG 82.02-3:1998ISO 17234-1:2010BSEN ISO 17234-1:2010BSEN ISO 17234-2:2011Determination of PCP/ TeCPDIN 53313:1996Determination of PCP TeCP/TCPISO 17070:2015Determination of PCP LMBG 82.02-08:2001Determination of OPPIn house 12-LO-S0865Based on LMBG 82.02-08:2001 (Issue no-1/ 25.07.2016)Determination of Chrome VIISO 17075:2007Color fastness to crockingAATCC 8:2013Polycyclic Aromatic Hydrocarbons (PAHs)AfPS GS 2014:01 PAKISO/TS 16190:2013/ZEK 01.2-2008Organo Tin CompoundsTributyltin (TBT)Dibutyltin (DBT)Monobutyl tin (MBT)Tetrabutyl tin (TeBT)Triphenyl tin (TPhT)Mono n-octyl tin (MOT)Di-n-octyl tin (DOT)Tri-cyclohexyl tin (TCyHT)Tri octyl tin (TOT)Tri-n-propyl tin (TPrT)ISO/TS 16179:2012Mono Phenyl tin (MPhT)Di Phenyl tin (DPhT)Methyl tinDi-n-propyl tin (DPrT)Di Heptyl tinDi Methyl tinTri Methyl tinELECTRICAL TESTINGLOCATION 1I.SAFETY TEST FACILITY1.Safety requirements for electrical equipment for measurement, control, and laboratory use-particular requirements for control equipmentImpact testIEC 61010-2-201, Editon 2.0 2017/03 Clause 8.2.2Overload testIEC 61010-2-201, Editon 2.0, 2017/03 Clause 4.4.2.101.2Endurance testIEC 61010-2-201, Editon 2.0, 2017/03 Clause 4.4.2.101.1II.DOMESTIC ELECTRICAL APPLIANCES1.Microwave Oven, Blenders, Food mixers, food processors, Mincers appliancesMarking testIEC 60335-1 (Edition 5.2):2016-05, Clause. 7IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 7IS 302-1:2008, Clause. 7IS 302-2-25:2014, Clause. 7Protection against electric shockIEC 60335-1 (Edition 5.2):2016-05, Clause. 8IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 8IS 302-1:2008, Clause. 8IS 302-2-25:2014, Clause. 8Power Input and currentIEC 60335-1 (Edition 5.2):2016-05, Clause. 10IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 10IS 302-1:2008, Clause. 10IS 302-2-25:2014, Clause. 10Heating test/Temperature riseIEC 60335-1 (Edition 5.2):2016-05, Clause. 11IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 11IS 302-1:2008, Clause. 11IS 302-2-25:2014, Clause. 11Leakage Current (At operating Temperature)IEC 60335-1 (Edition 5.2):2016-05, Clause. 13IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 13IS 302-1:2008, Clause. 13IS 302-2-25:2014, Clause. 13Electric Strength (At operating temperature)IEC 60335-1 (Edition 5.2):2016-05, Clause. 13IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 13IS 302-1:2008, Clause. 13IS 302-2-25:2014, Clause. 13Moisture resistanceIEC 60335-1 (Edition 5.2):2016-05, Clause. 15IEC 60335-2-25 (Edition 6.2): 2015-11, Clause. 15IS 302-1:2008, Clause. 15IS 302-2-25:2014,Clause.15Leakage current (After Humidity test)IEC 60335-1 (Edition 5.2):2016-05, Clause. 16IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 16IS 302-1:2008, Clause. 16IS 302-2-25:2014, Clause. 16Electrical strength (After Humidity Test)IEC 60335-1 (Edition 5.2):2016-05, Clause. 16IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 16IS 302-1:2008, Clause. 16IS 302-2-25:2014, Clause. 16Overload protection testIEC 60335-1 (Edition 5.2):2016-05, Clause. 17IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 17IS 302-1:2008, Clause. 17IS 302-2-25:2014, Clause. 17Endurance testIEC 60335-1 (Edition 5.2):2016-05, Clause. 18IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 18IS 302-1:2008, Clause. 18IS 302-2-25:2014, Clause. 18Abnormal operation TestIEC 60335-1 (Edition 5.2):2016-05, Clause. 19IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 19IS 302-1:2008, Clause. 19IS 302-2-25:2014, Clause. 19Stability and Mechanical hazardsIEC 60335-1 (Edition 5.2):2016-05, Clause. 20IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 20IS 302-1:2008, Clause. 20IS 302-2-25:2014, Clause. 20Mechanical StrengthIEC 60335-1 (Edition 5.2):2016-05, Clause. 21.1IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 21.1IS 302-1:2008, Clause. 21.1IS 302-2-25:2014, Clause. 21.1Construction (tests)IEC 60335-1 (Edition 5.2):2016-05, Clause. 22IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 22IS 302-1:2008, Clause. 22IS 302-2-25:2014, Clause. 22Internal Wiring (Flexing Test)IEC 60335-1 (Edition 5.2):2016-05, Clause. 23IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 23IS 302-1:2008, Clause. 23IS 302-2-25:2014, Clause. 23Cord gripIEC 60335-1 (Edition 5.2):2016-05, Clause. 25.15IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 25.15IS 302-1:2008, Clause. 25.15IS 302-2-25:2014, Clause. 25.15Terminal for external conductorsIEC 60335-1 (Edition 5.2):2016-05, Clause. 26IEC 60335-2-25 (Edition 6.0):2010-09IS 302-1:2008, Clause. 26IS 302-2-25:2014, Clause. 26Provision for earthingIEC 60335-1 (Edition 5.2):2016-05, Clause. 27IEC 60335-2-25 (Edition 6.2):2015-11IS 302-1:2008, Clause. 27IS 302-2-25:2014, Clause. 27Screws and ConnectionsIEC 60335-1 (Edition 5.2):2016-05, Clause. 28IEC 60335-2-25 (Edition 6.2):2015-11,IS 302-1:2008, Clause. 28IS 302-2-25:2014, Clause. 28Creepage distances and clearancesIEC 60335-1 (Edition 5.2):2016-05, Clause. 29IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 29IS 302-1:2008, Clause. 29IS 302-2-25:2014, Clause. 29Resistance to Heat, Fire and Tracking (Glow wire Test)IEC 60335-1 (Edition 5.2):2016-05, Clause. 30IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 30IS 302-1:2008, Clause. 30IS 302-2-25:2014, Clause. 30Resistance to Heat, Fire and Tracking (Needle flame Test)IEC 60335-1 (Edition 5.2):2016-05, Clause. 30IEC 60335-2-25 (Edition 6.2):2015-11, Clause. 30IS 302-1:2008, Clause. 30IS 302-2-25:2014, Clause. 30Resistance to Heat, Fire and Tracking (Ball pressure test)IEC 60335-1 (Edition 5.2):2016-05, Clause. 30IEC 60335-2-25 (Edition 6.2):2015-11IS 302-1:2008, Clause. 30IS 302-2-25:2014, Clause. 30Resistance to RustingIEC 60335-2-25 (Edition 6.2):2015-11IS 302-1:2008, Clause. 31IS 302-2-25:2014, Clause. 31Radiation hazardsIEC 60335-1 (Edition 5.2):2016-05, Clause. 32IEC 60335-2-25 (Edition 6.0):2010-09IS 302-1:2008, Clause. 32IS 302-2-25:2014, Clause. 32III.TRANSMISSION LINE EQUIPMENT AND ACCESSORIES1.LV Switchgear and Control Gear AssemblyDielectric PropertiesIEC 61439-1 (Edition 2.0)2011-08 EN 61439-1:2011Clause. 10.9,10.9.2,10.9.3Temperature Rise limit Clause. 10.10Short circuit withstand strength of protective devices Clause. 10.5.3Short circuit withstand strengthClause 10.11Resistance to corrosion (Damp Heat and Salt mist for enclosures and metallic parts)Clause. 10.2.2Thermal Stability Clause. 10.2.3.1Resistance to abnormal heat and fire due to internal electric effectClause 10.2.3.2Mechanical impact Clause 10.2.6Marking Clause 10.2.7Degree of protection of enclosureClause 10.3Clearances and Creepage distance Clause 10.4Protection against electric shock and integrity of protective circuitClause 10.5Effective continuity between the exposed conductive parts of the assembly and the protective circuit Clause 10.5.2Mechanical Operations Clause. 10.132.Low-Voltage Switchgear and Control Gear Assemblies-Power Switchgear and Control Gear AssembliesDielectric PropertiesIEC 61439-2 (Edition 2.0):2011-08IEC 61439-1 (Edition 2.02011-08 EN 61439-2:2011EN 61439-1:2011Clause. 10.9,10.9.2,10.9.3Temperature Rise limitClause. 10.10Short circuit withstand strength of protective devicesClause. 10.5.3Short circuit withstand strength Clause 10.11Resistance to corrosion (Damp Heat and Salt mist for enclosures and metallic parts)Clause. 10.2.2Thermal Stability Clause. 10.2.3.1 Resistance to abnormal heat and fire due to internal electric effectClause. 10.2.3.2Mechanical impact Clause. 10.2.6Degree of protection of enclosuresClause. 10.3Marking Clause. 10.2.7Clearances and Creepage Distances Clause. 10.4Protection against electric shock and integrity of protective circuit Clause 10.5Effective continuity between the exposed conductive parts of the assembly and the protective circuitClause 10.5.2Mechanical OperationsClause. 10.133.Low-Voltage Switchgear and Control Gear Assemblies-Busbar Trunking Systems (Busways)Dielectric Properties IEC 61439-1 (Edition 2.0)2011-08 IEC 61439-6 (Edition 1.0): 2012-05 EN 61439-1:2011EN 61439-6:2012Clause. 10.9Temperature Rise limit Clause. 10.10Short circuit withstand strength of protective device Clause. 10.5.3Short circuit withstand strength Clause 10.11Resistance to corrosion (Damp Heat and Salt mist for enclosures & metallic part)Clause. 10.2.2 Thermal Stability Clause. 10.2.3.1 Resistance to abnormal heat and fire due to internal electric effectClause. 10.2.3.2Mechanical impact Clause. 10.2.6Marking Clause 10.2.7Degree of protection of enclosures Clause. 10.3Ability to withstand mechanical loads Clause. 10.2.101Resistance of the enclosure to crushing Clause. 10.2.101.3Thermal cycling test Clause. 10.2.102Clearances and Creepage Distances Clause. 10.4Protection against electric shock and integrity of protective circuitClause 10.5Effective continuity between the exposed conductive parts of the assembly and the protective circuitClause 10.5.2Mechanical Operations Clause. 10.pression and Mechanical ConnectorsHeat Cycle test IEC 61238-1, (Edition 2):2003-05 Clause. 6.3Electrical Resistance Measurement Clause. 6.2.1Short Circuit test Clause. 6.3.4Tensile Force-Mechanical Tests Clause. 75.Rewirable Type Electric Fuses Visual examination IS 2086:1993(RA 2009) Clause. 9.1Test for dimensionsClause. 9.2Test for mechanical enduranceClause. 9.3Test for Mechanical StrengthClause. 9.4Test for withdrawal forceClause. 9.5Test for temperature-rise Clause. 9.6Insulation resistanceClause. 9.7High Voltage TestClause. 9.8Test for breaking capacityClause. 9.9Test for water absorptionClause. 9.10Temperature cycle test (for ceramic material)Clause. 9.11.1IV.SWITCHGEAR EQUIPMENT1.Circuit BreakersInput testIEC 60947-1 (5.2 Edition):2014-09EN 60947-1-2007/A2:2011/A2:014Temperature testIEC 60947-1 (5.2Edition):2014-09Clause 4.2.2Overload testIEC 60947-1(5.2 Edition):2014-09Endurance testIEC 60947-1(5.2 Edition):2014-09Dielectric voltage withstand testIEC 60947-1(5.2 Edition):2014-09 Clause. 7.2.3Crossover potential test IIEC 60947-1(5.2 Edition):2014-09Under/over voltage testIEC 60947-1(5.2 Edition):2014-09Crossover potential test IIIEC 60947-1(5th Edition):2007-06Tripping limits and characteristics IEC 60947-2 (Edition 5): 2016-06/IEC 60947-1:2007/ AMD1:2010EN 60947-2:2017IS/IEC 60947-2:2003Clause. 8.3.3.2Dielectric propertiesClause. 8.3.3.3Marking Clause 5.2Constructional requirement Clause 7.1Mechanical operation and operational performance capability Clause. 8.3.3.4Overload performance (where applicable) Clause. 8.3.3.5 Verification of dielectric withstand Clause. 8.3.3.6 Verification of temperature-rise Clause. 8.3.3.7Verification of overload releasesClause. 8.3.3.8Verification of under voltage and shunt releases (if applicable)Clause. 8.3.3.9Verification of main contact position (for circuit breakerssuitable for isolation)Clause. 8.3.3.10Rated service short-circuit breaking capacity Clause. 8.3.4.2 and 8.3.8.4 Verification of Operational performance capability Clause. 8.3.4.3 and 8.3.8.5Rated ultimate short circuit breaking capacityClause. 8.3.5.3Rated short-time withstand currentClause. 8.3.8.32.Switches, Disconnectors, Switch-Disconnectors and Fuse-Combination UnitsTemperature-rise IEC 60947-3:2008+AMD1:2012+AMD2:2015 (Edition 3.2) 2015-07IEC 60947-1:2007+ AMD1:2010+AMD2:2014 EN 60947-3:2009/ A1:2012/A2:2015IS/IEC 60947-3:1999IS/IEC 60947-1, Clause. 8.3.3.1Temperature-rise Verification Clause. 8.3.3.6, 8.3.4.4, 8.3.5.5Dielectric properties Clause. 8.3.3.2, 8.3.4.2Leakage current Clause. 8.3.3.5, 8.3.4.3, 8.3.5.4Rated making and breaking capacities (overload)Clause. 8.3.3.3Dielectric verification Clause 8.3.3.4, 8.3.5.3Operational performance Clause. 8.3.4.1Rated short-time withstand current Clause. 8.3.5.1Rated short-circuit making capacity Clause. 8.3.5.2Rated conditional short-circuit current Clause. 4.3.6.4Strength of actuator MechanismClause. 8.3.3.7Fuse protectedshort-circuitwithstandClause 8.3.6.2.1a)Fuse protectedshort-circuit makingClause 8.3.6.2.1 b)Overload test Clause. 8.3.7.1Mechanical operation test Clause. 8.1.3.23.Contactors and Auxiliary Contacts Verification of temperature riseIEC 60947-4-1:2009+AMD1:2012 (Edition:3.1) 2012-07IEC 60947-1EN 60947-4-1:2010/A1:2012IS 60947 (Part 4/Sec I):2000 Clause. 9.3.3.3Temperature Test Verification of operation and operating limitsIEC 60947-4-1:2009+AMD1:2012 (Edition:3.1) 2012-07EN 60947-4-1:2010/A1:2012IS/IEC 60947-4-1:2000Clause. 9.3.3.1 and 9.3.3.2Overvoltage and under voltage test Normal load and overload performance requirementsIEC 60947-4-1:2009+AMD1:2012 (Edition:3.1) 2012-07EN 60947-4-1:2010/A1:2012IS/IEC 60947-4-1:2000Clause. 8.2.4 Verification of degrees of protection of enclosed contactors and startersIS 60947 (Part 4/Sec I):2000 IEC 60947-1 Annexure C Verification of dielectric propertiesIS 60947 (Part 4/Sec I):2000IEC 60947-4-1:2009+AMD1:2012 (Edition:3.1) 2012-07EN 60947-4-1:2010/A1:2012Clause. 9.3.3.4Dielectric Voltage-Withstand TestOverload withstand capability of contactors.IS 60947 (Part 4/Sec I):2000IEC 60947-4-1:2009+AMD1:2012 (Edition:3.1) 2012-07EN 60947-4-1:2010/A1:2012Clause. 9.3.5Crossover lead di-electric test ICrossover lead di-electric test IICalibration test(Overload relays)Breakdown of component testSecondary circuit testLeakage current testVerification of rated making and breaking capacities, IS 60947 (Part 4/Sec I): 2000IEC 60947-4-1:2009+AMD1:2012 (Edition:3.1) 2012-07EN 60947-4-1:2010/A1:2012Clause. 9.3.3.5Change-over ability and reversibility where applicableOverload test Verification of operational performance capabilityIEC 60947-4-1:2009+AMD1:2012 (Edition:3.1) 2012-07EN 60947-4-1:2010/A1:2012 IS 60947 (Part 4/Sec I):2000 Clause. 9.3.3.6Endurance test Performance under short-circuit conditionsIEC 60947-4-1:2009+AMD1:2012 (Edition:3.1) 2012-07EN 60947-4-1:2010/A1:2012IS 60947 (Part 4/Sec I):2000 Clause. 9.3.44.Auxiliary Contacts, Add on Blocks, Frontle Blocks, Manual Push Buttons Verification of operation and operating limitsIEC 60947-5-1:2016/COR1:2016 (Edition 4.0) /IEC 60947-5-1 2016-05IEC 60947-1EN 60947-5-1:2004/A1:2009 IS/IEC 60947 (Part 5/Sec I):2003Clause. 8.3.3.1 and 8.3.3.2Overvoltage and Under voltage Test Verification of temperature riseIEC 60947-5-1:2016/COR1:2016 (Edition 4.0) IEC 60947-5-1 2016-05EN 60947-5-1:2004/ A1:2009IS/IEC 60947 (Part 5/Sec I): 2003Temperature TestClause 8.3.3.3Verification of dielectric propertiesEC 60947-5-1:2016/COR1:2016 (Edition 4.0) IEC 60947-5-12016-05EN 60947-5-1:2004/A1:2009IS/IEC 60947 (Part 5/Sec I):2003Clause. 8.3.3.4Dielectric Voltage-Withstand Test Verification of rated making and breaking capacities under normal conditionsIEC 60947-5-1:2016/COR1:2016 (Edition 4.0) IEC 60947-5-12016-05EN 60947-5-1:2004/A1:2009IS/IEC 60947 (Part 5/Sec I):2003Clause. 8.3.3.5.3 Verification of mechanical properties of terminalsIEC 60947-5-1:2016/COR1:2016 (Edition 4.0) IEC 60947-5-12016-05EN 60947-5-1:2004/A1:2009IS/IEC 60947 (Part 5/Sec I):2003IEC 60947-1 Clause. 8.2.4Secureness and Pullout Test (Mechanical sequence ) Verification of the performance of terminal assemblies IEC 60947-1 Clause. 8.2.4Measurement of clearances and creepage distancesIEC 60947-5-1:2016/COR1:2016 (Edition 4.0) IEC 60947-5-1 2016-05EN 60947-5-1:2004/A1:2009IS/IEC 60947 (Part 5/Sec I):2003Clause. 7.1.4Spacings Verification of limitation of rotation of a rotary switchIEC 60947-5-1:2016/COR1:2016 (Edition 4.0) IEC 60947-5-12016-05EN 60947-5-1:2004/A1:2009IS/IEC 60947 (Part 5/Sec I):2003 Clause. 8.2.6 Verification of degrees of protection of enclosed contactors and startersIEC 60947-5-1:2016/COR1:2016 (Edition 4.0) IEC 60947-5-1 2016-05EN 60947-5-1:2004/ A1:2009IS/IEC 60947 (Part 5/Sec I): 2003Annex C of IEC 60947-1 Clause 4.1.12 Verification of actuation force or momentIEC 60947-5-1:2016/COR1:2016 (Edition 4.0) IEC 60947-5-12016-05EN 60947-5-1:2004/A1:2009IS/IEC 60947 (Part 5/Sec I):2003 Clause. 8.2.5Overload and Endurance, Pilot duty Verification of rated making and breaking capacities under abnormal conditions:Overload and endurance tests (Auxiliary devices)IEC 60947-5-1:2016/COR1:2016 (Edition 4.0) IEC 60947-5-12016-05EN 60947-5-1:2004/A1:2009IS/IEC 60947 (Part 5/Sec I):2003Clause. 8.3.3.5.4Breakdown of component testPerformance under conditional short-circuit currentIEC 60947-5-1:2016/COR1:2016 (Edition 4.0) IEC 60947-5-1 2016-05EN 60947-5-1:2004/ A1: 2009IS/IEC 60947 (Part 5/Sec I): 2003 Clause. 8.3.45.Electrical Connector, Terminal Blocks for Copper Conductors, Fuse Terminal BlocksDielectric TestsIEC 60947-7-1:2009 (Edition 3.0) 2009-04IEC 60947-1EN 60947-7-1:2009Clause. 8.4.3Dielectric Voltage-Withstand Test Verification of Voltage dropIEC 60947-7-1:2009 (Edition 3.0) 2009-04EN 60947-7-1:2009Clause. 7.2.4, 8.4.4 Voltage drop testTemperature riseIEC 60947-7-1:2009 (Edition 3.0) 2009-04EN 60947-7-1:2009Clause. 7.2.1, 8.4.5Temperature test(It is same as temperature rise test) Verification of mechanical CharacteristicsIEC 60947-7-1:2009 (Edition 3.0) 2009-04EN 60947-7-1:2009Clause. 8.3.3Secureness and Pullout Test (Mechanical sequence ) Verification of the performance of terminal assemblies Verification of creepage and clearancesClause. 8.4.2SpacingsSolid wire tightening testTab pull testMold stress relief test Verification of thermal CharacteristicsIEC 60947-7-1:2009 (Edition 3.0) 2009-04EN 60947-7-1:2009 Clause. 8.5Short time current sequence test Aging test (for screwless-type terminal blocks only)IEC 60947-7-1:2009 (Edition 3.0) 2009-04EN 60947-7-1:2009Clause 8.4.7Heat cycling test (Spring force type terminal block) Verification of thermal CharacteristicsIEC 60947-7-1:2009 (Edition 3.0) 2009-04EN 60947-7-1:2009Clause. 8.5Conditioning test (Spring force type terminal block)6.Low-Voltage Switchgear and Control gear-Part 7-2:Ancillary Equipment-Protective Conductor Terminal Blocks for Copper ConductorsDielectric Tests IEC 60947-7-2 (Edition 3.0):2009EN 60947-7-2:2009Clause. 7.2.2, 8.4.3Temperature rise Clause. 7.2.1, 8.4.5 Verification of Voltage Drop Clause. 7.2.4, 8.4.4Short-time withstand current Clause. 4.3.2, 8.4.6Verification of mechanical characteristicsClause. 8.3.1Verification of mechanical characteristics IEC 60947-7-3 (Edition 2.0):2009 EN 60947-7-3:2009Clause. 8.3.3 Attachment of the fuse terminal block on its supportClause. 8.3.3Mechanical properties of clamping units of a fuse terminal block Clause. 8.3.3Testing for damage to and accidental loosening of conductors of a fuse terminal block (flexion test)Clause. 8.3.3Pull-out test IEC 60947-1 Clause. 8.3.4.4Verification of rated cross-section and rated connecting capacity Clause. 8.3.3.47.MCBMarking Clause 6 General Clause 8.1.1MechanismIS/IEC 60898-1:2002IEC 60898-1:2015/COR1:2015, (Edition 2.0) 2015-11IS/IEC 60898-1 2015EN 60898-1:2003/A1:2004/A11:2005/A13:2012Clause. 8.1.2Clearances and creepage distancesIS/IEC 60898-1:2002IEC 60898-1:2015/COR1:2015, (Edition 2.0) 2015-11IS/IEC60898-1 2015EN 60898-1:2003/A1:2004/A11:2005/A13:2012 Clause. 8.1.3 Non-interchangeabilityIS/IEC 60898-1:2002IEC 60898-1:2015/COR1:2015, (Edition 2.0) 2015-11IS/IEC 60898-1 2015EN 60898-1: 2003/ A1:2004/ A11: 2005/A13:2012 Clause. 8.1.6Test of dielectric propertiesIS/IEC 60898-1:2002IEC 60898-1:2015/COR1:2015, (Edition 2.0) 2015-11IS/IECEN 60898-1:2003/A1:2004/ A11: 2005/A13:2012Clause. 9.7Dielectric voltage-WithstandIndelibility of markingIS/IEC 60898-1:2002IEC 60898-1:2015/COR1:2015, (Edition 2.0) 2015-11IS/IEC 60898-1 2015EN 60898-1:2003/ A1:2004/A11:2005/ A13:2012Clause. 9.3Test of reliability of screws, current-carrying parts and connectionsIS/IEC 60898-1:2002IEC 60898-1:2015/ COR1:2015, (Edition 2.0) 2015-11IS/IEC 60898-1 2015EN 60898-1:2003/ A1:2004/A11:2005/A13: 2012 Clause. 9.4Test of reliability of terminals for external conductorsIS/IEC 60898-1:2002IEC 60898-1:2015/COR1:2015, (Edition 2.0) 2015-11IS/IEC 60898-1 2015EN 60898-1:2003/A1:2004/A11: 2005/A13:2012Clause. 9.5Test of protection against electric shockIS/IEC 60898-1:2002IEC 60898-1:2015/COR1:2015, (Edition 2.0) 2015-11IS/IEC 60898-1 2015EN 60898-1:2003/A1:2004/A11:2005/ A13:2012Clause 9.6Resistance to mechanical stresses and impactIS/IEC 60898-1:2002IEC 60898-1:2015/COR1:2015, (Edition 2.0) 2015-11IS/IEC 60898-1 2015EN 60898-1:2003/A1:2004/A11:2005/ A13:2012 Clause. 9.13.2Test of resistance to heatIS/IEC 60898-1:2002IEC 60898-1:2015/COR1:2015, (Edition 2.0) 2015-11EN 60898-1:2003/A1:2004/A11:2005/ A13:2012 Clause. 9.14Test of temperature-rise IS/IEC 60898-1:2002IEC 60898-1:2015/COR1:2015, (Edition 2.0) 2015-11EN 60898-1:2003/A1:2004/A11:2005/ A13:2012 Clause 9.8Temperature TestResistance to abnormal heat and to fireIS/IEC 60898-1:2002IEC 60898-1:2015/COR1:2015, (Edition 2.0) 2015-11IS/IEC 60898-1 2015EN 60898-1:2003/A1:2004/A11:2005/ A13:2012 Clause 9.15Resistance to rustingIS/IEC 60898-1:2002IEC 60898-1:2015/COR1:2015, (Edition 2.0) 2015-11IS/IEC 60898-1 2015EN 60898-1:2003/A1:2004/A11:2005/A13:2012 Clause. 9.16 Resistance to mechanical shockIS/IEC 60898-1:2002IEC 60898-1:2015/COR1:2015, (Edition 2.0) 2015-11EN 60898-1:2003/A1:2004/A11:2005/ A13:2012 Clause. 9.1328 day test ACClause. 9.9Test of tripping characteristicClause. 9.10Test of mechanical and electrical enduranceIS/IEC 60898-1:2002IEC 60898-1:2015/COR1:2015, (Edition 2.0) 2015-11IS/IEC 60898-1:2015EN 60898-1:2003/A1:2004/A11:2005/ A13:2012 Clause. 9.11Performance at reduced short-circuit currentsIS/IEC 60898-1:2002IEC 60898-1:2015/COR1:2015, (Edition 2.0) 2015-11IS/IEC 60898-1 2015EN 60898-1:2003/A1:2004/A11:2005/ A13:2012 Clause. 9.12.11.2.1Short circuit performance at 1500 AIS/IEC 60898-1:2002IEC 60898-1:2015/COR1:2015, (Edition 2.0) 2015-11IS/IEC 60898-1 2015EN 60898-1:2003/A1:2004/A11:2005/ A13:2012 Clause. 9.12.11.3Short-circuit test on circuit-breakers rated 230 V, or 240 V or 230/400 V for verifying their suitability for use in IT systemsClause 9.12.11.2.2Service short-circuit capacity (ics)IS/IEC 60898-1:2002IEC 60898-1:2015/COR1:2015, (Edition 2.0) 2015-11IS/IEC 60898-1 2015EN 60898-1:2003/A1:2004/A11:2005/ A13:2012 Clause. 9.12.11.4.2Performance at rated short-circuit capacity (icn)IS/IEC 60898-1:2002IEC 60898-1:2015/COR1:2015, (Edition 2.0) 2015-11IS/IEC 60898-1 2015EN 60898-1:2003/A1:2004/A11:2005/ A13:2012 Clause 9.12.11.4.3Test at the making and breaking capacity on an individual pole (Icn1) of multipole circuit-breakersClause 9.12.11.4.48.RCCBMarkingClause. 6IEC 61008-1:2010+A1:2012+A2:2013, (Edition 3.2) 2013-09IS 12640 (Part 1):2016IS 12640:1 2008EN 61008-1:2012/A1:2014/A11:2015General Clause 8.1.1MechanismClause. 8.1.2Clearance and creepage distancesClause. 8.1.3Indelibility of markingClause. 9.3Test of reliability of screws, current-carrying parts and connectionsClause. 9.4Test of reliability of terminals for external conductorsClause 9.5Test of protection against electric shockClause. 9.6Verification of resistance to Mechanical shocks and impactClause. 9.12Test of resistance to heatClause. 9.13Test of Dielectric propertiesClause. 9.7Test of temperature-riseClause. 9.8Residual Operating CharacteristicsClause. 9.9 Mechanical and Electrical enduranceClause. 9.10Performance at IδmClause. 9.11.2.3a bVerification of the suitability of RCCBs for use in IT-systemsClause. 9.11.2.3c)Coordination at IncClause. 9.11.2.4aPerformance at ImClause. 9.11.2.4cCoordination at ImClause. 9.11.2.4bCoordination at IδcClause. 9.11.2.2Resistance to abnormal heat and to fireClause. 9.14Verification of trip-free mechanismClause. 9.15Verification of the operation of the test device at the limits of rated voltageClause. 9.16Verification of the behavior of RCCBs functionally dependent on line voltageClause. 9.17Non-Operating current under over current conditionsClause 9.18Verification of behavior of RCCBs in case of current surges caused by impulse voltagesClause. 9.19Resistance to Rusting Clause 9.25 Verification of the correct operation at residual currents with d.c. componentsClause. 9.21 Verification of reliabilityClause. 9.22Climatic testClause. 9.22.1Test for Reliability at 40 °CClause. 9.22.2 Verification of ageing of electronic componentsClause. 9.23 9.RCBOMarkingIEC 61009-1:2010+A1:2012+A2:2013 (Edition 3.2) 2013-09IS 12640 (Part 2) 2016IS 12640-2 2008EN 61009-1:2012/ A1:2014/A11:2015/A2:2016Clause. 6MechanismClause. 8.1.2Clearance and creepage distancesClause. 8.1.3Non-interchangeabilityClause. 8.1.6Indelibility of markingClause. 9.3Test of reliability of screws, current-carrying parts and connectionsClause. 9.4Test of reliability of terminals for external conductorsClause. 9.5Test of protection against electric shockClause. 9.6Resistance to Mechanical Shock and impactClause. 9.13Test of resistance to heatClause. 9.14Dielectric propertiesClause. 9.7Test of temperature-riseClause. 9.8Operating characteristics under residual current conditionsClause. 9.9 Verification of mechanical and electrical enduranceClause. 9.10Resistance to abnormal heat and to fireClause. 9.15 Verification of trip-free mechanismClause. 9.11 Verification of the operation of the test device at the limits of rated voltageClause. 9.16 Verification of the behavior of RCBOs functionally dependent on line voltageClause. 9.17Verification of behaviour of RCBOs in case of current surges caused by impulse voltagesClause. 9.19 Verification of reliabilityClause. 9.22Resistance to Rusting Clause 9.25Climatic testClause. 9.22.1Test for reliability at 40 °CClause. 9.22.2ageing of electronic componentsClause. 9.23Performance at reduced short-circuit currentsClause.9.12.11.2.1Short-circuit test for verifying the suitability of RCBOs for use in IT systemsClause.9.12.11.2.2Test at 1500 AClause 9.12.11.3Performance at service short-circuit capacity (ICS)Clause. 9.12.11.4 bVerification of the Coordination at the rated Conditional short-circuit current (Inc)Clause. 9.12.11.4 cVerification of the rated Residual making and breaking capacity (IM)Clause. 9.12.1310.Electronic Air Break SwitchesElectric strength testAS/ NZS 3133:2013+Amd. 1 Clause. 13.4+A2 Clause. 13.4Insulation resistance testAS/ NZS 3133:2013+ Amd. 1+A2Clause. 13.3Endurance testAS/ NZS 3133:2013+ Amd. 1+A2Clause. 13.5Heating test/Temperature riseAS/ NZS 3133:2013+ Amd. 1+A2Clause. 13.2Humidity testAS/ NZS 3133:2013+ Amd. 1+A2Clause. 13.1.10Leakage currentAS/ NZS 3133:2013+ Amd. 1+A2Clause. A4.2Impulse testAS/ NZS 3133:2013+ Amd. 1+A2Clause. A4.3Degree of protection of assembliesAS/ NZS 3133:2013+ Amd. 1+A2Clause. 13.12Mechanical strength of actuating memberAS/ NZS 3133:2013+ Amd. 1+A2Clause. A4.411.Residual Current deviceInsulation resistance testAS/ NZS 3190:2016Clause. 8.2Electric strength testAS/ NZS 3190:2016Clause. 8.3Impulse testAS/ NZS 3190:2016/Clause. 8.5Current surge testAS/ NZS 3190:2016Clause. 8.6Earthing connectionAS/ NZS 3190:2016 AS/ NZS 3100:2017, Clause. 8.5Cord anchorageAS/ NZS 3190:2016AS/ NZS 3100:2017, Clause. 8.6Screw thread and fixingsAS/ NZS 3190:2016AS/ NZS 3100:2017, Clause. 8.7Heating testAS/ NZS 3190:2016Clause. 8.7Tripping test AS/ NZS 3190:2016Clause. 8.8Endurance testAS/ NZS 3190:2016Clause. 8.14Short-time through-current withstand testAS/ NZS 3190:2016Clause. 8.15Climatic testAS/ NZS 3190:2016Clause. A2Verification of ageing of electronic componentsAS/ NZS 3190:2016Clause. 8.19ReliabilityAS/ NZS 3190:2016Clause. 8.1812.Residual Current DeviceInsulation resistance testIEC 60669-1 I NT 1:2012(Edition 3.2)IEC 60669-1:2007(Edition 3.2)IEC 60669-2-1:2002+ AMD1:2008+AMD2:2015 CSV (Edition 4.2)IEC 60669-2-3:2006(Edition.0)IEC 60669-2-4:2004(Edition 1.0)IEC 60669-2-5:2013(Edition 1.0)IEC 60669-2-6:2012(Edition 1.0) Clause. 16Electric strength testClause. 16Impulse testClause. 26.1.2Current surge testClause. 26.1.2Earthing connectionClause. 11Cord anchorageClause. 11screw thread and fixingsClause. 22Heating testClause. 17Endurance testClause. 18Short-time through-current withstand testClause. 101Touch current testClause. 10.202Marking testClause. 8Protection against access live partsClause. 10V.ELECTRICAL MEASURING INSTRUMENTS?1.ELECTRICAL MEASURING INSTRUMENTS (Energy Meters)Electrical and Electronic (Static) Energy Meters/Prepayment Meters(Energy Meter)Test of Insulation PropertiesImpulse Voltage Test As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Clause. 12.7.6.2IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.7.6.2 CBIP 325:2015, Clause. 5.4.6.2IEC 62052-11:2003+A1:2016 Cl.7.3IS 15884:2010; Cl. 5.4.6.2IEC 62055-31 (1st Edition):2005-09 Clause. 7.7 IS16444:2015 Cl.6.10.6AC High Voltage test As per Standard:IS 13779:1999 (RA 2014), with amd. 1,2,3 4, 5, Clause. 12.7.6.3IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.7.6.3 CBIP 325:2015, Clause. 5.4.6.2IEC 62052-11:2003+A1:2016Clause. 7.3.3IEC 62053-21:2003+A1:2016 Clause. 7.4IEC 62053-22:2003+A1:2016Clause. 7.4 IS 15884:2010Cl. 5.4.6.3IEC 62055-31 (1st Edition):2005-09 Clause. 7.7 IS16444:2015 Cl.6.10.6Insulation Resistance test As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Clause. 12.7.6.4IS 14697:1999 (RA 2014), Amd:1, 2, 3 & 4 Clause. 12.7.6.4CBIP 325:2015, Clause. 5.4.6.2IS 15884:2010Cl. 5.4.6.4IS16444:2015 Cl.6.10.6Test of Accuracy Requirement?Test on Limits of error As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Clause. 11.1IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 11.1CBIP 325:2015, Clause. 5.4.6.2IEC 62053-21, (1st Edition):2016, Clause. 8.1IEC 62053-22 (1st Edition):2016, Clause. 8.1,8.5IEC 62053-23 (1st Edition) 2016, Clause. 8.1, 8.5 IS 15884:2010 ; Cl. 4.6.1IEC 62055-31 (1st Edition): 2005-09 Clause. 8 IS16444:2015 Cl.6.12Test of Meter Constant As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Clause. 12.15,11.6IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.14CBIP 325:2015, Clause. 5.6.6IEC 62053-22 (1st Edition):2016, Clause. 8.4IEC 62053-23 (1st Edition):2016, Clause. 8.4IS 15884:2010 ; Cl. 5.6.5IEC 62055-31 (1st Edition):2005-09 Clause. 8 IS16444:2015 Cl.6.12Interpretation of test results As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Clause. 12.16IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.15IEC 62053-21 (1st Edition):2016, Clause. 8.6IEC 62053-22 (1st Edition):2016, Clause. 8.6IEC 62053-23 (1st Edition):2016, Clause. 8.6?IS16444:2015 Cl.6.12Test of Starting Condition As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Clause. 12.14,11.5IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.13CBIP 325:2015, Clause. 5.6.5IEC 62053-21 (1st Edition):2016, Clause. 8.3IEC 62053-22 (1st Edition):2016, Clause. 8.3IEC 62053-23 (1st Edition):2016, Clause. 8.3 IS 15884:2010Cl. 5.6.4IEC 62055-31 (1st Edition):2005-09 Clause. 8 IS16444:2015 Cl.6.12Test of No Load Condition As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Clause. 12.13,11.4IS 14697:1999 (RA 2004), Clause. 12.12CBIP 325:2015, Clause. 5.6.4IEC 62053-21 (1st Edition):2016, Clause. 8.3IEC 62053-22 (1st Edition):2016, Clause. 8.3IEC 62053-23 (1st Edition):2016, Clause. 8.3 IS 15884:2010 Cl. 5.6.3IEC 62055-31 (1st Edition): 2005-09 Clause. 8 IS16444:2015 Cl.6.12Test of Ambient temperature influence As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Clause. 12.12,11.3IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.11CBIP 325:2015, Clause. 5.6.3IEC 62053-21 (1st Edition):2016, Clause. 8.2IEC 62053-22 (1st Edition):2016, Clause. 8.2IEC 62053-23 (1st Edition):2016, Clause. 8.2 IS 15884:2010 ; Cl. 4.6.3IEC 62055-31 (1st Edition):2005-09 Clause. 8 IS16444:2015 Cl.6.12Test of Repeatability of error As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5, Clause. 12.17IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.16CBIP 325:2015, Clause. 5.6.9IS 15884:2010 ; Cl. 5.6.7IEC 62055-31 (1st Edition): 2005-09 Clause. 8 Influence Quantities As per Standard: Voltage VariationIS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Clause. 12.11, (Table 17)Frequency VariationIS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.10Waveform 10 % of third harmonicCBIP 325:2015, Clause. 5.6.2Reverse Phase SequenceIEC 62053-21 (1st Edition):2016, Clause. 8.2Voltage unbalanceDC component in ac current circuitIEC 62053-22 (1st Edition):2016, Clause. 8.2Continuous magnetic induction of external origin Magnetic induction of external orign-0.5 mT IEC 62053-23 (1st Edition): 2016, Clause. 8.2 Influence Quantities As per Standard:IS 14697:1999, Clause. 12.10 (Table 13) Auxiliary Voltage IS 15884:2010 ; Cl. 4.6.2(Table 12)IS16444:2015 Cl.6.12Phase of Auxiliary Supply voltage by 120 °Test of Electrical Requirement ?Test of Power Consumption As per Standard:IS 13779:1999, with Amd. 1,2,3 4, 5 Clause. 12.7.1IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.7.1CBIP 325:2015,Clause.5.4.1IEC 62053-21 (1st Edition): 2016Clause. 7.1IEC 62053-22 (1st Edition): 2016, Clause. 7.1IEC 62053-23 (1st Edition): 2016Clause. 7.1 IS 15884:2010 ; Cl. 5.4.1IS16444:2015 Cl.6.10.1IEC 62055-31 (1st Edition): 2005-09 Clause. 7.3 Test of Influence of Supply voltage As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Clause. 12.7.2IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.7.2CBIP 325:2015, Clause. 5.4.2IEC 62052-11:2003+A1: 2016, Clause. 7.1.2IEC 62053-21, (1st Edition):2016,Clause. 8.2IEC 62053-22 (1st Edition):2016, Clause. 8.2IEC 62053-23 (1st Edition):2016Clause. 8.2IS 15884:2010Cl. 4.4.2 & 5.4.2IS16444:2015 Cl.6.10.2IEC 62055-31 (1st Edition): 2005-09 Clause. 7.2.2 Test of Influence Short time Over currents As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Clause. 12.7.3IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.7.3CBIP 325:2015, Clause. 5.4.3IEC 62053-21 (1st Edition): 2016, Clause. 7.2IEC 62053-22 (1st Edition): 2016, Clause. 7.2IEC 62053-23 (1st Edition): 2016, Clause. 7.2IS 15884:2010Cl. 5.4.3 and 4.4.3IS16444:2015 Cl.6.10.3IEC 62055-31 (1st Edition):2005-09 Clause. 7.4 Test of Influence of Self Heating As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Clause. 12.7.4IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.7.4CBIP 325:2015, Clause. 5.4.4IEC 62053-21 (1st Edition):2016, Clause. 7.3IEC 62053-22 (1st Edition):2016, Clause. 7.3IEC 62053-23 (1st Edition):2016, Clause. 7.3IS 15884:2010 Cl. 5.4.4IS16444:2015 Cl.6.10.4IEC 62055-31 (1st Edition):2005-09 Clause. 7.6 Test of Influence of Heating As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Clause. 12.7.5IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.7.5CBIP 325:2015, Clause. 5.4.5IEC 62052-11:2003+ A1:2016 2, Clause. 7.2IS 15884:2010Cl. 5.4.5IS16444:2015 Cl.6.10.5IEC 62055-31 (1st Edition): 2005-09 Clause. 7.5 Test of Immunity to earth fault As per Standard:IS 13779:1999 (RA 2002) with Amd. 1, 2, 3 & 4, Clause. 12.8IEC 62052-11:2003+ A1:2016, Clause. 7.4IS 15884:2010 ; Cl. 4.4.2.6IS16444:2015 Cl.6.10.7IEC 62055-31 (1st Edition):2005-09 Clause. 7.2.3 Test for Climatic Influence ?Dry Heat test As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5/Clause. 12.6.1IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.6.1CBIP 325:2015, Clause. 5.3.1IEC 62052-11:2003+ A1:2016, Clause. 6.3.1IS 15884:2010/Cl. 5.3.1IS16444:2015 Cl.6.9Cold test As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Clause. 12.6.2IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.6.2 CBIP 325:2015 Clause. 5.3.2IEC 62052-11:2003+ A1:2016, Clause. 6.3.2IS 15884:2010Cl. 5.3.2IS16444:2015 Cl.6.9Damp Heat Cyclic test As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Clause. 12.6.3IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.6.3CBIP 325:2015, Clause. 5.3.3IEC 62052-11:2003+ A1:2016, Clause. 6.3.3IS 15884:2010Cl. 5.3.3IS16444:2015 Cl.6.9IEC 62055-31 (1st Edition): 2005-09 Clause. 7.2.2 Test for Mechanical Requirement?Spring Hammer test As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Clause. 12.3.3IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.3.3CBIP 325:2015, Clause. 5.2.1IEC 62052-11:2003+ A1:2016, Clause. 5.2.2.1IS 15884:2010Cl. 5.2.1IS16444:2015 Cl.6.5Vibration TestIS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Cl. 12.3.2IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Cl. 12.3.2 IEC 62052-11:2003+A1:2016, Cl. 5.2.2.3IS 15884:2010Cl. 5.2.3IS 16444:2017 Cl. 6.5Shock TestIS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Cl. 12.3.1IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Cl. 12.3.1CBIP Report 304Cl. 5.2.2IEC 62052-11:2003+A1:2016, Cl. 5.2.2.2IS 15884:2010 Cl. 5.2.2IS 16444:2017 CI.6.5Protection against penetration of dust and water As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5/Clause. 12.5IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.5 CBIP 325:2015, Clause. 5.2.5IEC 62052-11:2003+A1:2016, Clause. 5.9.IS 15884:2010Cl. 5.2.5IS16444:2015 Cl.6.5IEC 62055-31 (1st Edition):2005-09 Clause. 5.10 Test of Resistance of Heat and fire As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5, Clause. 12.4, 6.8IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 12.4 CBIP 325:2015, Clause. 5.2.4IEC 62052-11:2003+A1:2016, Clause. 5.8IS 15884:2010Cl. 5.2.4IS16444:2015 Cl.6.5IEC 62055-31 (1st Edition):2005-09 Clause. 5.9Heat Deflection Test As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5/Clause. 6.4IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 6.4 CBIP 325:2015, Clause. 4.2.2.3IEC 62052-11:2003+ A1:2016, Clause. 5.4 IS 15884:2010 Cl. 4.2.4Clearances and Creepage distances As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5 Clause. No.:6.6 IS 14697:1999 (RA 2014), With amd 1.2.3 & 4Clause. 6.6 CBIP 325:2015, Clause. 4.2.2.5IEC 62052-11:2003+ A1:2016, Clause. 5.6IS 15884:2010Cl. 4.2.6IS16444:2015 Cl.6.3IEC 62055-31 (1st Edition): 2005-09 Clause. 5.7 General and Construction requirements As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5/Clause. 6.0IS 14697:1999 (RA 2014), With amd 1.2.3 & 4/Clause. 6.0CBIP 325:2015, Clause. 4.2IEC 62052-11:2003+A1:2016, Clause. 5.0Marking of Meters As per Standard:IS 13779:1999 (RA 2014), with Amd. 1,2,3 4, 5/Clause. 7.0IS 14697:1999 (RA 2014), With amd 1.2.3 & 4/Clause. 7.0CBIP 325:2015, Clause. 4.2.2.11IEC 62052-11:2003+A1:2016, Clause. 5.12 IS 15884:2010/Cl. 4.2.11IS16444:2015 Cl.6.8IEC 62055-31 (1st Edition): 2005-09 Clause. 5.13ELECTRICAL TESTINGLOCATION 2I.CELLS & BATTERIES1.Secondary Nickel System Cells & Batteries Insulation and wiringIS 16046 (Part 1) : 2018 / IEC 62133-1 : 2017, Clause 5.2Charging procedure - DischargingIS 16046 (Part 1) : 2018 / IEC 62133-1 : 2017, Clause 7.1Continuous Low-rate chargingIS 16046 (Part 1) : 2018 / IEC 62133-1 : 2017, Clause 7.2, 7.2.1VibrationIS 16046 (Part 1) : 2018 / IEC 62133-1 : 2017, Clause 7.2, 7.2.2Case stress at high ambient temperature (Batteries)IS 16046 (Part 1) : 2018 / IEC 62133-1 : 2017 (Clause 7.2, 7.2.3)Temperature cyclingIS 16046 (Part 1) : 2018 / IEC 62133-1 : 2017 (Clause 7.2, 7.2.4) External short circuitIS 16046 (Part 1) : 2018 / IEC 62133-1 : 2017 (Clause 7.3, 7.3.2)Free fallIS 16046 (Part 1) : 2018 / IEC 62133-1 : 2017 (Clause 7.3, 7.3.3)Mechanical shock (Crash hazard) IS 16046 (Part 1) : 2018 / IEC 62133-1 : 2017 (Clause 7.3, 7.3.4)OverchargeIS 16046 (Part 1) : 2018 / IEC 62133-1 : 2017 (Clause 7.3, 7.3.8)Crushing of cellsIS 16046 (Part 1) : 2018 / IEC 62133-1 : 2017 (Clause 7.3, 7.3.6)Incorrect installationIS 16046 (Part 1) : 2018 / IEC 62133-1 : 2017 (Clause 7.3, 7.3.1)Thermal abuse (Cells)IS 16046 (Part 1) : 2018 / IEC 62133-1 : 2017 (Clause 7.3, 7.3.5)Low pressure(cells)IS 16046 (Part 1) : 2018 / IEC 62133-1 : 2017 (Clause 7.3, 7.3.7)Forced discharge(Cell)IS 16046 (Part 1) : 2018 / IEC 62133-1 : 2017 (Clause 7.3, 7.3.9)2.Secondary Lithium System Cells & BatteriesInsulation and wiringIS 16046 (Part 2) : 2018 / IEC 62133-2 : 2017 (Clause 5.2)Charging procedure - DischargingIS 16046 (Part 2) : 2018 / IEC 62133-2 : 2017 (Clause 7.1)Charging Procedures for test purposes- Second ProcedureIS 16046 (Part2) : 2018 / IEC 62133-2 : 2017 (Clause 7.1.2)Continuous chargeIS 16046 (Part2) : 2018 / IEC 62133-2 : 2017 (Clause 7.2.1)VibrationIS 16046 (Part2) : 2018 / IEC 62133-2 : 2017 (Clause 7.3, 7.3.8, 7.3.8.1)Case stress at high ambient temperature (Batteries)IS 16046 (Part 2) : 2018 / IEC 62133-2 : 2017 (Clause 7.2.2)External short circuitIS 16046 (Part 2) : 2018 / IEC 62133-2 :2017 (Clause 7.3, 7.3.1)External short circuitIS 16046 (Part 2) : 2018 / IEC 62133-2 :2017 (Clause 7.3, 7.3.2)Free fallIS 16046 (Part 2) : 2018 / IEC 62133-2 :2017 (Clause 7.3, 7.3.3)Mechanical shock (Crash hazard)IS 16046 (Part 2) : 2018 / IEC 62133-2 : 2017 (Clause 7.3, 7.3.8, 7.3.8.2)OverchargeIS 16046 (Part 2) : 2018 / IEC 62133-2 :2017 (Clause 7.3, 7.3.6)Crushing of cellsIS 16046 (Part 2) : 2018 / IEC 62133-2 :2017 (Clause 7.3, 7.3.5)Thermal abuse (Cells)IS 16046 (Part 2) : 2018 / IEC 62133-2 :2017 (Clause 7.3, 7.3.4)Forced discharge (Cell)IS 16046 (Part 2) : 2018 / IEC 62133-2 :2017 (Clause 7.3, 7.3.7)Measurement of Internal AC Resistance of Coin CellsIS 16046 (Part 2) : 2018 / IEC 62133-2 :2017, (Annexure D,D2)3.Lithium Ion Cells & Batteries, Ni-MH Cells & Batteries Crush TestIS 16046 : 2015, Rev 1, (Clause 7.3.6, 8.3.5)ELECTRONICS TESTINGLOCATION 1I.ENVIRONMENTAL TEST FACILITY1.Environmental Testing of Electronics & Electrical Items Drop TestQM333 Issue. 2:1998Toppling TestQM333 Issue. 2:1998Fall TestQM333 Issue. 2:1998Cold TestEN/IEC 60068-2-1:2007IEC 61850-3, Edition 2, 2013-12QM333 Issue. 2:1998Dry HeatEN/IEC 60068-2-2:2007IEC 61850-3, Edition 2, 2013-12QM333 Issue. 2:1998Salt Mist TestIEC 60068-2-11, (3rd Edition):1981QM333 Issue. 2:1998Change of Temperature(Test Na) (2 chamber method)IEC 60068-2-14 (6th Edition):2009IEC 61850-3, Edition 2, 2013-12QM333 Issue. 2:1998Damp heat, cyclic(Test Db)IEC 60068-2-30,(3rd Edition):2005-08IEC 61850-3, Edition 2, 2013-12Test Kb (sodium chloride solution)Dust-IP 1 x to IP 6 xIEC 60529:2013-08,(Edition 2.2) 1+Corr. 3IEC 61850-3, Edition 2, 2013-12Degrees of Protection):provided by enclosuresIEC 60068-2-78 (2nd Edition):2012-10Damp Heat, steady state IEC 61850-3, Edition 2, 2013-122.PV Solar ModuleVibration TestQM 3.3: 2010, Issue –Mar 2010, Test No. 6 (Cl. 3.6.1 to 3.6.7)RMATION TECHNOLOGY EQUIPMENT1.Power adaptors, Mobile Phone, Cash Register, Point of Sale Terminal, Copying Machine, Franking Machine, Passport reader, Computer Systems, Printers Scanners, iris scanner, Optical finger print scanner,USB driven Barcode readers, barcode scanners,Smart watches CCTV Cameras/Equipment for CCTV Cameras. Keyboards, & Automatic Data Processing Machine, Set top Box.Input TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 1.6.2)Thermal requirementIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 4.5.1)Overload of operator accessible PartsIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 5.3.7)Humidity conditioningIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 2.9.1)Electric strength TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 5.2.2)Touch current TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 5.1)Abnormal operation TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 5.3.1)Capacitance discharge TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 2.1.1.7)Limited power source measurement TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 2.5)Working voltage determinationIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 2.10.2)Protective bonding Test IIIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 2.6.3.4)Limited current circuit measurementsIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 2.4.1)Limitation of touch current to a telecommunication and cable distribution systemIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 5.1.8.1)Requirement of separation between telecommunication network from earthIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 6.1.2)Steady force TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 4.2.1)Impact TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 4.2.5)Strain relief TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 3.2.6)Cord guard TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 3.2.8)Hazardous moving Parts TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 4.4.2)Stability TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 4.1)Durability of marking TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 1.7.11)Stress relief TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 4.2.7)Drop TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 4.2.6)2.Mobile PhonesLanguage Input test & VerificationIS 16333 (Part 3):2017, Cl 53.Automatic Data Processing Machine, Laptop/Notebook/Tablet, Printers, Plotters, Scanners, Set Top Box, Telephone Answering Machines, Visual Display Units, Videos Monitors, Wireless Keyboards, Cash Registers, Copying Machines/Duplicators, Passport Reader, Point Of Sale Terminals, Mail Processing Machines/Postage Machines/Franking Machines, Power Banks For Use In Portable Applications, Smart Card Reader, Mobile Phones, Power Adaptors, CCTV Cameras/ CCTV Recorders, USB Driven Barcode Reader, Barcode Scanners/Iris Scanners/ Optical Fingerprint Scanners, Smart Watches, Computer SystemsDirect plug in equipmentIS 13252 (Part 1): 2010 +Amd. 1: 2013 +Amd. 2: 2015, (Clause 4.3.6)III.AUDIO/ VIDEO COMPONENTS AND PRODUCTS1. Power adaptor, Televisions, Optical Disc Players, Amplifier, Electronic Musical SystemHumidity treatmentEN/IEC 60065:2014, Clause. 10.2 IS 616:2017-Rev 5, Clause. 10.2IV.MEASURING INSTRUMENTS 1.Electronic Equipment-Digital millimeter, digitalpower meter, clamp meter, digital ammeter,Digital voltmeter, Digital panel power meter.Protective impedance TestUL 61010-1 (2nd Edition)2005-07-22.CAN/CSA C22.2 No. 61010-1,(2nd Edition):004-07,IEC 61010-1:2010, (3rd Edition)(Clause. 4.4.2.2)IEC 61010-2-030:2010, (1st Edition).(Clause. 101.3.3)Input TestUL 61010-1 (2nd Edition):2005-07-22.CAN/CSA C22.2 No. 61010-1,(2nd Edition):004-07,IEC 61010-1:2010, (3rd Edition)(Clause. 5.1.3)Temperature TestUL 61010-1 (2nd Edition):2005-07-22.CAN/CSA-C22.2 No. 61010-1,(2nd Edition):004-07,IEC 61010-1:2010 (3rd Edition)(Clause. 10.1-10.4)Humidity conditioningUL 61010-1 (2nd Edition):2005-07-22.CAN/CSA-C22.2 No. 61010-1,(2nd Edition):004-07,IEC 61010-1:2010, (3rd Edition)(Clause. 6.8.2)Dielectric voltage withstand TestUL 61010-1 (2nd Edition):2005-07-22.CAN/CSA-C22.2 No. 61010-1,(2nd Edition):004-07,IEC 61010-1:2010, (3rd Edition)(Clause. 6.8)Permissible limits TestUL 61010-1 (2nd Edition):2005-07-22.CAN/CSA-C22.2 No. 61010-1,(2nd Edition):004-07,IEC 61010-1:2010, (3rd Edition)(Clause. 6.3)Transformer overload TestUL 61010-1 (2nd Edition):2005-07-22.CAN/CSA-C22.2 No. 61010-1,(2nd Edition):004-07,IEC 61010-1:2010, (3rd Edition)(Clause. 4.4.2.7.3)Transformer short circuit TestUL 61010-1 (2nd Edition):2005-07-22.CAN/CSA-C22.2 No. 61010-1,(2nd Edition):004-07,IEC 61010-1:2010, (3rd Edition)(Clause. 4.4.2.7.2)Insulation between circuitsUL 61010-1 (2nd Edition):2005-07-22.CAN/CSA-C22.2 No. 61010-1,(2nd Edition):004-07,IEC 61010-1:2010, (3rd Edition)(Clause. 4.4.2.12)Output abnormal TestUL 61010-1 (2nd Edition):2005-07-22.CAN/CSA-C22.2 No. 61010-1,(2nd Edition):004-07,IEC 61010-1:2010, (3rd Edition)(Clause. 4.4.2.8)Applied force TestUL 61010-1 (2nd Edition):005-07-22.CAN/CSA-C22.2 No. 61010-1,(2nd Edition):004-07IEC 61010-1:2010, (3rd Edition)(Clause. 6.2.2)Ball pressure TestUL 61010-1 (2nd Edition):005-07-22.CAN/CSA-C22.2 No. 61010-1,(2nd Edition):004-07IEC 61010-1:2010, (3rd Edition)(Clause. 10.5.3)Static rigidity TestUL 61010-1 (2nd Edition):005-07-22.CAN/CSA-C22.2 No. 61010-1,(2nd Edition):004-07IEC 61010-1:2010, (3rd Edition)(Clause. 8.2.1)Strength of Handle TestUL 61010-1 (2nd Edition):2005-07-22.CAN/CSA-C22.2 No. 61010-1(2nd Edition):004-07IEC 61010-1:2010(3rd Edition)(Clause. 7.5)Mechanical abuse TestUL 61010-1 (2nd Edition):2005-07-22.CAN/CSA-C22.2 No. 61010-1,(2nd Edition):004-07,IEC 61010-1:2010, (3rd Edition)(Clause. 10.5.2)Current measuring circuit TestIEC 61010-2-030:2010, (Edition 1.0) (Clause. 14.101)Durability of Marking IEC61010-1,2010, 3rd Edition(Clause 5.3)Stability TestIEC61010-1,2010, 3rd Edition(Clause 7.4)Wall Mounting TestIEC61010-1,2010, 3rd Edition(Clause 7.6)Impact TestIEC61010-1,2010, 3rd Edition(Clause 8.2.2)Drop TestIEC61010-1,2010, 3rd Edition (Clause 8.3.1,8.3.2)Limited Energy Circuit Determination TestIEC61010-1,2010, 3rd Edition (Clause 9.4)Resistance To Heat Of Non-metallic Enclosure TestResistance to Heat of Nonmetallic Enclosure Test (Clause 10.5.2)2.Electrical & Electronics Products (IFM modules, Storages, servers), Cabinets, Racks, Sub racks, Chassis. Printed Circuit Boards. Aerospace Products (Signal Trackers,Navigation Sensors,Voice Receivers, Timers) Consumer Products (Amplifier, Mosfet Transistors, Luminaires) Railway Mounted and Railway Transporting Products (AC and Exhaust Fan) Sine and random vibration Test, QualitativeIEC 60068-2-6:2007IEC 60068-2-64:2008IEC 60065:2014IEC 62133:2002MIL-STD-810G:2008(Method 514.6C-I)MIL STD 883E:1997 Method 2007.2, 2002 & 2026 MIL STD 202G:2002 Method 201A (2.4.1-Part 1)IEC 61373:20103.Batteries and CellsSine vibrationUN38.3 (Edition 6):2015 (38.3.4.3) 4.Phones, Laptops, Power BanksPower adaptors, inverters, Energy meters.Signal control receivers Motors, TV’s, laptops, Mobile phones. Aerospace products (signal trackers,Navigation sensors, voice receivers, Timers) Railway mounted and railway transportingProducts (AC and exhaust fan)Shock Electro dynamic shaker-Half sineIEC 60068-2-27:2008MIL-STD-810G:2008, Method 514.6MIL STD 202G:2002 Method 201AIEC 61373:2010Trapezoidal Final peak saw tooth, Initial saw tooth. 5.PCB mounted Electrical & electronics Products(Energy meters,Control receivers Mobile phones, Battery chargers)Batteries and Cells Spares & Assemblies mounted in Defense/ Military/ Aerospace (signal trackers, Navigation sensors, voice receivers, Timers) Railway mounted and railway transportingProductsMechanical Shock Machine-Half sine Trapezoidal, saw toothIEC 60068-2-27:2008UN38.3(Edition 6):2015MIL-STD-810G:2008, Method 516.6MIL STD 883E:1997 Method 2002.3MIL STD 202G:2002 Method 213 BIEC 61373:20106.Batteries & Cells,Spares and assemblies in aircraft (signal trackers, Navigation sensors, voice receivers, Timers). Helicopters and manned aerospace vehicles (Amplifier Mosfet Transistors, Luminaires)Altitude TestIEC 60068-2-13-1994IEC 60721-1:2002 (1.3)IEC 62133:2002Combined cold/low air pressure Tests-IEC 60068-2-40-1983MIL-STD-810G:2008 Method 500.5-1MIL-STD-810G:2008 Method 520.3V.MISCELLANEOUS PRODUCTS: PHOTOVOLTAIC EQUIPMENT1.Thin-film terrestrial photovoltaic (PV) modules-Design qualification and type approvalVisual inspectionIEC 61646 (2nd Edition):2008-05, Clause. 10.1IS 16077:2013 Clause 10.1Maximum power determinationIEC 61646 (2nd Edition):2008-05. Clause. 10.2IEC 60904-9, IEC 60904-6, IEC 60904-1, IEC 60891IS 16077:2013, Clause 10.2Insulation TestIEC 61646 (2nd Edition):2008-05. Clause. 10.3IS 16077:2013, Clause 10.2Wet leakage current TestIEC 61646 (2nd Edition):2008-05. Clause. 10.15IS 16077:2013, Clause 10.15Measurement of temperature coefficientsIEC 61646 (2nd Edition):2008-05. Clause. 10.4IEC 60904-10, IEC 60904-9, IEC 60904-1.IS 16077:2013, Clause 10.4Measurement of nominal operating cell temperature (NOCT)IEC 61646 (2nd Edition):2008-05. Clause. 10.5IS 16077:2013, Clause 10.5Performance at STC and NOCTIEC 61646 (2ndEdition):2008-05. Clause. 10.6IEC 60904-9, IEC 60904-1.IS 16077:2013, Clause 10.6Performance at low irradianceIEC 61646 (2nd Edition):2008-05. Clause. 10.7IEC 60904-9, IEC 60904-1IS 16077:2013, Clause 10.7Outdoor exposure TestIEC 61646 (2nd Edition):2008-05. Clause. 10.8IEC 60721-2-1.IS 16077:2013, Clause 10.8Hot-spot endurance TestIEC 61646 (2nd Edition):2008-05. Clause. 10.9IEC 60904-9, IEC 60904-1.IS 16077:2013, Clause 10.9UV preconditioning TestIEC 61646 (2nd Edition):2008-05. Clause. 10.10IS 16077:2013, Clause 10.10Thermal cycling TestIEC 61646 (2nd Edition):2008-05. Clause. 10.11IS 16077:2013, Clause 10.11Humidity-freeze TestIEC 61646 (2nd Edition):2008-05. Clause. 10.12IS 16077:2013, Clause 10.12Damp heat TestIEC 61646 (2nd Edition):2008-05. Clause. 10.13IS 16077:2013, Clause 10.13Robustness of terminations TestIEC 61646 (2nd Edition):2008-05. Clause. 10.14IS 16077:2013,Clause 10.14Mechanical load TestIEC 61646 (2nd Edition):2008-05. Clause. 10.16IS 16077:2013, Clause 10.16Hail TestIEC 61646 (2nd Edition):2008-05. Clause. 10.17IS 16077:2013, Clause 10.17Bypass diode thermal TestIEC 61646 (2nd Edition):2008-05. Clause. 10.18IS 16077:2013, Clause 10.18Light Soaking IEC 61646 (2nd Edition):2008-05. Clause. 10.19IS 16077:2013, Clause 10.192.Crystalline silicon terrestrial photovoltaic (PV) modules-Design qualification and type approvalPreconditioningIEC 61215 (2nd Edition):2005-04 IS 14286:2010Visual inspectionIEC 61215 (2nd Edition):2005-04 (Clause. 10.1)IS 14286:2010 (Clause. 10.1)IEC-2 (1st Edition) 2004-10, MST01IS/IEC 61730-2:2004 (MST01)(Clause. 10.1)/EN 61730-2Maximum power determination / Voltage, current and power measurements TestIEC 61215 (2nd Edition):2005-04 (Clause. 10.2) (Clause. 10.2)UL 1703 (3rd Edition):2002-15 (Clause. 20)IS 14286:2010, (Clause. 10.2) (Clause. 10.2)Insulation TestIEC 61215 (2nd Edition):2005-04 (Clause. 10.3)IS 14286:2010 (Clause. 10.3)Dielectric withstand testIEC 61730-2 (1st edition):2004-10, MST 16IS/IEC 61730-2:2004, MST 16 EN 61730-2Wet leakage current TestIEC 61215 (2nd Edition): 2005-04 (Clause. 10.15)IEC 61730-2 (1st Edition):2004-10, (MST 17)IS 14286:2010, Clause 10.15IS/IEC 61730-2:2004, MST 17 EN 61730-2Measurement of temperature coefficientsIEC 61215 (2nd Edition):2005-04 (Clause. 10.4)IS 14286:2010(Clause. 10.4)Measurement of nominal operating cell temperature (NOCT)IEC 61215 (2nd Edition):2005-04 (Clause. 10.5)IS 14286:2010, Clause 10.5Performance at STC and NOCTIEC 61215 (2nd Edition):2005-04 (Clause. 10.6)IS 14286:2010,(Clause. 10.6)Performance at low irradianceIEC 61215 (2nd Edition):2005-04 (Clause. 10.7)IS 14286:2010(Clause. 10.7)Outdoor exposure TestIEC 61215 (2nd Edition):2005-04, (Clause. 10.8)IS 14286:2010,(Clause. 10.8)Hot-spot endurance TestIEC 61215 (2nd Edition):2005-04, (Clause. 10.9)IS 14286:2010, (Clause. 10.9)IEC 61730-2 (1st Edition) + (Amendment 1:2011-11, MST 22IS/IEC 61730-2:2004, MST 22 EN 61730-2Thermal cycling TestIEC 61215 (2nd Edition):2005-04, (Clause. 10.11) IEC 61730-2 (1st Edition):2004-10, MST 51a, MST 51bIS 14286:2010, (Clause. 10.11)UL 1703 (3rd Edition):2002-03 (Clause. 35)IS/IEC 61730-2:2004, MST 51a, MST 51bEN 61730-2Humidity-freeze TestIEC 61215 (2nd Edition):2005-04, (Clause. 10.12)IS 14286:2010, (Clause. 10.12)IEC 61730-2 (1st Edition):2004-10, MST 52IS/IEC 61730-2:2004, MST 52/UL 1703 (3rd Edition): 2002-03 (Clause. 36) EN 61730-2Damp heat TestIEC 61215 (2nd Edition):2005-04 (Clause. 10.13) IEC 61730-2 (1st Edition):2004-10 MST 53IS 14286:2010, (Clause. 10.13)IS/IEC 61730-2:2004, MST 53 EN 61730-2UV preconditioning TestIEC 61215 (2nd Edition):2005-04 (Clause. 10.10) IEC 61730-2 (1st Edition):2004-10, MST 54IS 14286:2010, (Clause. 10.10)IS/IEC 61730-2:2004, MST 54 EN 61730-2Bypass diode thermal TestIEC 61215 (2nd Edition): 2005-04, (Clause. 10.18)IS 14286:2010, (Clause. 10.18) IEC 61730-2 (1st Edition):2004-10, MST 25IS/IEC 61730-2:2004, MST 25 EN 61730-2Partial discharge TestIEC 61730-2 (1st Edition):2004-10, Clause. 11.1 MST 15IS/IEC 61730-2:2014, MST 15 EN 61730-2Impulse voltage TestIEC 61730-2 (1st Edition):2004-10, (MST 14)IS/IEC 61730-2:2004, MST 14 EN 61730-2Accessibility TestIEC 61730-2 (1st Edition):2004-10, (Clause. 10.2 MST 11)IS/IEC 61730-2:2004, MST 11 EN 61730-2Cut susceptibility TestIEC 61730-2 (1st Edition):2004-10, (Clause. 10.3 MST 12), Amendment 1:2011-11IS/IEC 61730-2:2004 MST 12 EN 61730-2Temperature TestIEC 61730 (1st Edition):2004-10, (Clause. 10.7 MST 21)IS/IEC 61730-2:2004 MST 21UL 1703 (3rd Edition):2002-03 (Clause. 19)EN 61730-2Leakage Current TestUL 1703 (3rd Edition):2002-03 (Clause. 21)Cut TestUL 1703 (3rd Edition):2002-03 (Clause. 24)Bonding Path resistance Test / Ground continuity TestIEC 61730-2 (1st Edition):2011-11, (Clause. 10.4) MST 13IS/IEC 61730-2:2004 MST13UL 1703 (3rd Edition):2002-03 (Clause. 25)EN 61730-2Dielectric Withstand TestUL 1703 (3rd Edition):2002-03 (Clause. 26)IEC 61730-2 (1st Edition):2011-11, (Clause. 10.6) MST 16IS/IEC 61730-2:2004EN 61730-2Wet Insulation-Resistance TestUL 1703 (3rd Edition):2002-03 (Clause. 27)Reverse Current Overload TestUL 1703 (3rd Edition):2002-03 (Clause. 28)IEC 61730 (Edition 1.1):2011-11, (Clause. 10.9) MST 26IS/IEC 61730-2:2004, MST 26 EN 61730-2Hot-Spot Endurance TestUL 1703 (3rd Edition):2002-03 (Clause. 39)Mechanical load TestIEC 61215 (2nd Edition):2005-04, (Clause. 10.16) IEC 61730-2 (1st Edition):2004-10, (Clause. 10.16) MST 34IS 14286:2010, (Clause. 10.16)IS/IEC 61730-2:2004, MST 34 EN 61730-2Hail TestIEC 61215 (2nd Edition):2005-04, (Clause. 10.17)IS 14286:2010, (Clause. 10.17) (Clause. 21)Module breakage TestIEC 61730-2 (1st Edition):2004-10, MST 32IS/IEC 61730-2:2004 MST 32 (Clause. MST 32)EN 61730-2Strain Relief TestUL 1703 (3rd Edition):2002-03 (Clause. 22)Push TestUL 1703 (3rd Edition):2002-03 (Clause. 23)Terminal Torque TestUL 1703 (3rd Edition):2002-03 (Clause. 29)Impact TestUL 1703 (3rd Edition):2002-03 (Clause. 30)Water Spray TestUL 1703 (3rd Edition):2002-03 (Clause. 33)Robustness of terminations TestIEC 61215 (2nd Edition):2005-04. Clause. 10.14IS 14286:2010, Clause 10.14 IEC 61730-2, (1st edition), MST 42 IS/IEC 61730-2, (1st edition), MST 42/EN 61730-23.Solar Photovoltaic modules, power conversion units and equipment which are intended for Corrosive environmentSalt Mist TestIEC 61701 (1st Edition): 1995-03 (Clause. 4)IEC 61701 (2nd Edition):2011-12IEC 60068-2-52 (2nd Edition):1996IEC 60068-2-11 (3rd Edition):1981 (Clause. 4)4.Photovoltaic Systems-Power Conditioners-Procedure for measuring Efficiency (Stand Alone Inverter & Grid Tie Inverter)EfficiencyIEC 61683 (1st edition):1999-11IS/IEC 61683:19995.Utility-Interconnected Photovoltaic Inverters-Test Procedure of Islanding Prevention Measures (Grid Tie Inverter)Test procedure to evaluate the Performance of Islanding Prevention Measures used with Utility-Interconnected PV systems / Un-intentional Islanding TestIEC 62116 (Edition 2.0): 2014IEEE 1547.1:2005, Clause. 5.7IS 16169:20146.Test Procedure for Equipment Interconnecting Distributed Resources with Electric Power SystemsTemperature stabilityIEEE 1547.1:2005, Sec 5.1Over/Under Voltage Test for Response to Abnormal Voltage Conditions IEC 61727 (2ndEdition): 2004, Clause:-5.2 IEEE 1547.1:2005, Sec 5.2Over/Under frequency Response to abnormal frequency conditionsIEC 61727 (2nd Edition):2004, Clause. 5.2IEEE 1547:2005 Sec 5.3SynchronizationIEEE 1547.1:2005 Sec 5.4Limitation of dc Injection for Inverters without Interconnection transformers/dc InjectionIEEE 1547.1:2005, Sec 5.6, IEC 61727 (2nd Edition): 2004Clause. 4.4Reconnect following abnormal condition disconnect or Response to Utility RecoveryIEEE 1547.1:2005, Clause. 5.10 IEC 61727 (2nd Edition):2004, Clause. 5.4Harmonics &Waveform DistortionIEC 61727 (2nd Edition):2004-12, Clause:4.6IEEE 1547.1-2005, Sec 5.11?FlickerIEC 61727 (2nd Edition):2004, Clause:4.3?IEEE 1547.1:2005, Sec 5.12Dielectric Test for Paralleling device IEEE 1547.1:2005, Sec 5.5.37.Balance-of-Systems Components for Photovoltaic Systems-Design Qualification Natural Environments (Solar Photovoltaic Charge Controller)Visual InspectionAs per MNRE Guidelines for Solar Charge Controller Testing with reference to clauses from IEC 62093:2005, (Clause. 11)IS 16229:2015Functioning TestsVoltage Drop TestInsulation TestProtection Against Mechanical Impact(IK-code)Determination of End of Charge VoltagesDetermination of Low Charge disconnect and Reconnect VoltagesTemperature Compensation for Thresholds8.Photovoltaic (PV) module safety qualification-Part-1:Requirements for constructionPolymeric materialsIEC 61730-1 Edition 1.2 2013-03 (Clause 5)IS/IEC 61730-1: 2004 (Clause 5) EN 61730-1UV Resistance testIEC 61730-1 Edition 1.2 2013-03 (Clause 5)IS/IEC 61730-1:2004 (Clause 5) EN 61730-1Temperature testIEC 61730-1 Edition 1.2 2013-03 (Clause 5)IS/IEC 61730-1:2004 (Clause 5) EN 61730-1Partial Discharge testIEC 61730-1 Edition 1.2 2013-03 (Clause 5)IS/IEC 61730-1:2004 (Clause 5) EN 61730-1Internal Wiring and current carrying partsIEC 61730-1 Edition 1.2 2013-03 (Clause 6)IS/IEC 61730-1:2004 (Clause 6) EN 61730-1Connections Accessibility testIEC 61730-1 Edition 1.2 2013-03 (Clause 7)IS/IEC 61730-1:2004 (Clause 7)Bonding and groundingIEC 61730-1 Edition 1.2 2013-03 (Clause 8)IS/IEC 61730-1:2004 (Clause 8) EN 61730-1Creepage and clearance distancesIEC 61730-1 Edition 1.2 2013-03 (Clause 9)IS/IEC 61730-1:2004 (Clause 9) EN 61730-1Field wiring compartments with coversIEC 61730-1 Edition 1.2 2013-03 (Clause 10)IS/IEC 61730-1:2004 (Clause 10) EN 61730-19.Power Converters for Use in Photovoltaic Power SystemsThermal TestingIEC 62109-1 1st Edition, 2010-04, Clause 4.3.2.1IS 16221 (Part 1):2016, Clause 4.3.2.1Touch temperaturesTemperature limits for mounting surfacesIEC 62109-1 1st Edition, 2010-04, Clause 4.3.2.2IS 16221 (Part 1): 2016, Clause 4.3.2.2Testing in single fault conditionIEC 62109-1 1st Edition, 2010-04, Clause 4.4IS 16221 (Part 1): 2016, Clause 4.4Humidity preconditioningIEC 62109-1 1st Edition, 2010-04, Clause 4.5IS 16221 (Part 1): 2016, Clause 4.5Back-feed voltage protectionIEC 62109-1 1st Edition, 2010-04, Clause 4.6IS 16221 (Part 1): 2016, Clause 4.6Electrical ratings testsIEC 62109-1 1st Edition, 2010-04, Clause 4.7IS 16221 (Part 1): 2016, Clause 4.7Durability of markingsIEC 62109-1 1st Edition, 2010-04, Clause 5.1.2IS 16221 (Part 1): 2016, Clause 5.1.2Ingress protectionIEC 62109-1 1st Edition, 2010-04, Clause 6.3IS 16221 (Part 1):2016, Clause 6.3Working voltage and DVCIEC 62109-1 1st Edition, 2010-04, Clause 7.3.2.6IS 16221 (Part 1): 2016, Clause 7.3.2.6Limitation of discharging energy through protective impedanceIEC 62109-1 1st Edition, 2010-04, Clause 7.3.5.3.2IS 16221 (Part 1):2016, Clause 7.3.5.3.2Protection by means of limited voltagesIEC 62109-1 1st Edition, 2010-04, Clause 7.3.5.4IS 16221 (Part 1):2016, Clause 7.3.5.4Protection against indirect contactIEC 62109-1 1st Edition, 2010-04, Clause 7.3.6IS 16221 (Part 1):2016, Clause 7.3.6Insulation including clearance and creepage distancesIEC 62109-1 1st Edition, 2010-04, Clause 7.3.7IS 16221 (Part 1):2016, Clause 7.3.7Residual Current Detection (RCD) or Monitoring (RCM) device compatibilityIEC 62109-1 1st Edition, 2010-04, Clause 7.3.8IS 16221 (Part 1):2016, Clause 7.3.8Protection against shock hazard due to stored energyIEC 62109-1 1st Edition, 2010-04, Clause 7.3.9IS 16221 (Part 1):2016, Clause 7.3.9Protection against energy hazardsIEC 62109-1 1st Edition, 2010-04, Clause 7.4IS 16221 (Part 1):2016, Clause 7.4Electrical tests related to shock hazardIEC 62109-1 1st Edition, 2010-04, Clause 7.5IS 16221 (Part 1):2016, Clause 7.5Protection against mechanical hazards(Stability, Provisions for lifting and carrying, Wall mounting)IEC 62109-1 1st Edition, 2010-04, Clause 8IS 16221 (Part 1):2016, Clause 8Cl.8.3Cl.8.4Cl.8.5Limited power sourcesIEC 62109-1 1st Edition, 2010-04, Clause 9.2 and 9.3IS 16221 (Part 1):2016, Clause 9.2 and 9.3Protection against sonic pressure hazardsIEC 62109-1 1st Edition, 2010-04, Clause 10IS 16221 (Part 1):2016, Clause 10Physical requirements- Handles and manual controls, Cord anchorages and strain relief, Stress Relief test, Mechanical resistance to deflection, impact or dropIEC 62109-1 1st Edition, 2010-04, Clause 13IS 16221 (Part 1):2016, Clause 13Cl.13.1Cl.13.3.2.5Cl.13.6.2.1/Cl.13.7ComponentsIEC 62109-1 1st Edition, 2010-04, Clause 14IS 16221 (Part 1):2016, Clause 1410.Safety of power converters for use in photovoltaic power systems-Part 2:Particular requirements for InvertersArray insulation resistance detection for inverters for ungrounded arraysIEC 62109-2 1st Edition, 2011-06, Clause 4.8.2.1IS 16221 (Part 2):2015, Clause 4.8.2.1Array insulation resistance detection for inverters for functionally groundedArraysIEC 62109-2 1st Edition, 2011-06, Clause 4.8.2.1IS 16221 (Part 2):2015, Clause 4.8.2.130 mA touch current type test for isolated invertersIEC 62109-2 1st Edition, 2011-06, Clause 4.8.3.2IS 16221 (Part 2):2015, Clause 4.8.3.2Fire hazard residual current type test for isolated invertersIEC 62109-2 1st Edition, 2011-06, Clause 4.8.3.3IS 16221 (Part 2):2015, Clause 4.8.3.3Protection By application of RCD’sIEC 62109-2 1st Edition, 2011-06, Clause 4.8.3.4IS 16221 (Part 2):2015, Clause 4.8.3.411.Photovoltaic (PV) module performance testing and energy rating-Part-1:Irradiance and temperature performance measurements and powerratingPower and rating conditions Clause 7 (Sub clause. No. 7.2, 7.3, 7.4, 7.5, 7.6)IEC 61853-1, Edition 1.0, 2011-01IS 16170 (Part 1):2014Procedure for irradiance and temperature performance measurements Clause 8 (Sub clause. No. 8.2, 8.3, 8.4, 8.5)IEC 61853-1, Edition 1.0, 2011-01IS 16170 (Part 1):2014Rating of power/Power rating Clause 9 (Sub clause No. 9.1 and 9.2)12.Photovoltaic (PV) module safety qualification-Part2: requirement for testing a) Thin-film terrestrial photovoltaic (PV) modules & b) Crystalline silicon terrestrial photovoltaic (PV) modulesFire Test MST 23 (Annex A)A.3 Spread of flame testA.4 Burning brand testIEC 61730-2 (Edition 1.1) : 2012-11, MST 23IEC 61730-2 (Edition 1) 2004-10, Clause 10.8, MST 23IS/IEC 61730-2, 2004, MST 23ELECTRONICS TESTINGLOCATION 2I.EMC TEST FACILITY1.EMI/EMC and ESD TestingEMI-EMC Testing: Electrical and Electronic InstrumentConducted Emission Test (CE)IEC 60601-1-2 (Edition 3.0):(2007-03)IEC 60601-1-2 (Edition 4.0) (2014-04)IEC 61000-6-3 (Edition 2.1) Consol. with Amd. 1 (2011-02)IEC 61000-6-4 (Edition 2.1 Consol. with Amd. 1 (2011-02)IEC 61000-6-4 (Ed 3.0)2018-02IEC 61326-1 (2nd Edition)-0 (2012-07)IEC 62040-2 (Edition 3.0) (2016-11)IEC 62052-11:2003+AMD1:2016 (Edition 1.1)IEC 60034-1 (Edition 12.0):(2010-02) IEC 60034-1 (Edition 13.0):(2017-05)IEC 60974-10:2014/AMD1:2015CISPR 11 (Edition 6.1) 2015+AMD1:2016-06CISPR 14-1 (Edition 6.0) (2016-08)CISPR 15:2013/AMD1 (2015-03) (Edition 8.1)CISPR 15:(2018-05) (Edition 9.0)CISPR 22 (Edition 6.0):(2008-09)CISPR 32:2015/COR1:2016 (Edition 2.0)EN 55011:2010EN 55011:2016+A1:2017EN 50121-3-2:2015EN 50121-3-2:2017EN 55014-1:2006+Amd. 2:2011EN 55014-1:2017EN 55015:2006+Amd. 2:2009EN 55015:2013EN 55022:2010/AC 2011EN 55032:2015EN 60601-1-2:2007/AC:2010EN 60601-1-2:2007/AC:2015EN 61000-6-3:2007/A1:2011EN 61000-6-4:2007/A1:2011EN 61326-1:2013EN 62040-2:2006EN 62052-11:2003EN 50121-4:2006EN 50121-4:2016EN 50121-3-2:2017CFR 2010 Title 47 Vol.1 (Part 15)CFR 2010 Title 47 Vol.1 (Part 18)IS 16102-2, Clause. 16.1IS 6873-5IS 13779:1999 (RA 2009)IS 6842:1997IS 14697:1999, (RA 2009)TEC/EMI/TEL-001/01/FEB-09/TEC/SD/DD/EMC-221/05/OCT-16Radiated Electromagnetic DisturbancesCISPR 15?(Edition 7.2):(2009-01)Clause. 4.4.1EN 55015:2006+ Amd. 2:2009Clause. 4.4.1IS 16102-2, Clause. 16.1IS 6873-5Harmonic Current Emission TestIEC 61000-3-2 (Edition 4):(2014-05)IEC 60601-1-2 (Edition 3.0):(2007-03)IEC 60601-1-2 (Edition 4.0):(2014-02)IEC 61000-6-3 (Edition 2.1):(2011-02)IEC 61326-1 (Edition 2.0):(2012-07)EN 60601-1-2:2007/AC:2010 EN 60601-1-2:2007/AC:2015EN 61000-3-2:2014IEC 61000-3-2 (Edition 4.0) (2014-05)EN 61000-6-3:2007 Amd. 1:2011EN 61326-1:2013IEC 60974-10:2014/AMD1:2015IS 14700 (Part 3/ Sec 2): 2008Voltage Fluctuation & Flicker TestIEC 61000-3-3 (Edition 3.0):(2013-05)IEC 60601-1-2 (Edition 3.0):(2007-03)IEC 60601-1-2 (Edition 4.0):(2014-02)IEC 61000-6-3 (Edition 2.1):(2011-02)IEC 61326-1 (Edition 2.0):(2012-07)IEC 60974-10:2014/AMD1:2015EN 60601-1-2:2007/AC:2010EN 60601-1-2:2007/AC:2015EN 61000-3-3:2008EN 61000-3-3:2013EN 61000-6-3:2007, Amd. 1:2011EN 61326-1:2013Electrostatic Discharge Immunity TestIEC 61000-4-2 (Edition 2.0):(2008-12)IEC 60601-1-2?(Edition 3.0):(2007-03)IEC 60601-1-2 (Edition 4.0):(2014-02)IEC 61000-6-1 (2nd Edition)-0 (2005-03)IEC 61000-6-1 (3nd Edition) (2016-08)IEC 61000-6-2?(Edition 2.0) (2005-01)IEC 61000-6-2 (3nd Edition)(2016-08)IEC 61326-1 (2nd Edition)-0 (2012-07)IEC 62040-2 (2nd Edition)-0 (2005-10)IEC 62052-11?(Edition 1.0):(2003-02)IEC 61547 (Edition 2.0):2009-06IEC 61850-3 (Edition 2.0) 2013-12IEC 60974-10:2014/AMD1:2015IEEE Std 1613.1 2013CISPR 14-2(Edition 2.0):2015 RLVCISPR 24?(Edition 2.0):(2010-08)CISPR 24?(Edition 2.1):(2015-04)CISPR 35 (Edition 1.0) (2016-08)EN 61000-4-2:2009EN 50121-3-2:2015EN 50121-3-2:2017EN 50121-4:2006 EN 50121-4:2016EN 55014-2:1997/Amd. 2:2008EN 55014-2:2015EN 55024:2010EN 60601-1-2:2007/AC:2010EN 60601-1-2:2007/AC:2015EN 61000-6-1:2007EN 61000-6-2:2005EN 61326-1:2013EN 62040-2:2006EN 62052-11:2003EN 61547:2009IS 13779:1999 (RA 2009)IS 14697:1999 (RA 2014)TEC/EMI/TEL-001/01/FEB-09TEC/SD/DD/EMC-221/05/OCT-16Electrical Fast Transient (EFT) / Burst Immunity TestIEC 61000-4-4 (Edition 3.0):(2012-04)IEC 60601-1-2?(Edition 3.0):(2007-03)IEC 60601-1-2 (Edition 4.0):(2014-02)IEC 61000-6-1?(2nd Edition):(2005-03)IEC 61000-6-1 (3nd Edition) (2016-08)IEC 61000-6-2 (2nd Edition):(2005-01)IEC 61000-6-2 (3nd Edition)(2016-08)IEC 61326-1?(2nd Edition):(2012-07)IEC 62040-2?(2nd Edition):(2005-10)IEC 62052-11?(Edition 1.0):(2003-02)IEC 61547:2009IEC 61850-3 (Edition 2.0) 2013-12IEC 60974-10:2014/AMD1:2015CISPR 14-2(Edition 2.0):2015 RLVCISPR 24?(2nd Edition):(2010-08) CISPR 24?(Edition 2.1):(2015-04)CISPR 35 (Edition 1.0) (2016-08)EN 61000-4-4:2012EN 55014-2:1997/Amd. 2:2008EN 55014-2:2015EN 55024:2010EN 60601-1-2:2007/AC 2010 EN 60601-1-2:2007/AC:2015EN 61000-6-1:2007EN 61000-6-2:2005EN 50121-3-2:2015EN 50121-3-2:2017EN 50121-4:2006EN 50121-4:2016EN 61326-1:2013EN 62040-2:2006EN 62052-11:2003EN 61547:2009IS 13779:1999 (RA 2009)IS 14697:1999 (RA 2014)TEC/EMI/TEL-001/01/FEB-09TEC/SD/DD/EMC-221/05/OCT-16Surge Immunity TestIEC 61000-4-5 (Edition 3.0):(2014-05)IEC 61000-4-5:2014/AMD1:2017 (Ed 3.1)IEC 60601-1-2? (Edition 3.0):(2007-03)IEC 60601-1-2 (Edition 4.0):(2014-02)IEC 61000-6-1 (2nd Edition):(2005-03)IEC 61000-6-1 (3nd Edition) (2016-08)IEC 61000-6-2?(2nd Edition):(2005-01)IEC 61000-6-2 (3nd Edition)(2016-08)IEC 61326-1?(2nd Edition):(2012-07)IEC 62040-2?(2nd Edition):(2005-10)IEC 62052-11?(Edition 1.0):(2003-02)IEC 61547:2009IEC 61850-3 (Edition 2.0) 2013-12IEC 60974-10:2014/AMD1:2015CISPR 14-2(Edition 2.0): 2015 RLVCISPR 24? (2nd Edition):(2010-08) CISPR 24?(Edition 2.1):(2015-04)CISPR 35 (Edition 1.0) (2016-08)IEEE Std 1613.1 2013EN 61000-4-5:2006EN 61000-4-5:2014EN 55014-2:1997/Amd. 2:2008EN 55014-2:2015EN 55024:2010EN 60601-1-2:2007/AC 2010EN 60601-1-2:2007/AC:2015EN 61000-6-1:2007EN 61000-6-2:2005EN 50121-3-2:2015EN 50121-4:2006EN 50121-4:2016EN 61326-1:2013EN 62040-2:2006EN 62052-11:2003EN 61547:2009TEC/EMI/TEL-001/01/FEB-09TEC/SD/DD/EMC-221/05/OCT-16Conducted RF Immunity TestIEC 61000-4-6 (Edition 4.0):(2013-10)IEC 60601-1-2? (Edition 3.0):(2007-03)IEC 60601-1-2 (Edition 4.0):(2014-02)IEC 61000-6-1?(2nd Edition):(2005-03)IEC 61000-6-1 (3nd Edition) (2016-08)IEC 61000-6-2 (2nd Edition):(2005-01)IEC 61000-6-2 (3nd Edition)(2016-08)IEC 61326-1 (2nd Edition):(2012-07)IEC 62040-2 (2nd Edition):(2005-10)IEC 62052-11?(Edition 1.0):(2003-02)IEC 61547:2009IEC 61850-3 (Edition 2.0) 2013-12IEC 60974-10:2014/AMD1:2015IEEE Std 1613.1 2013CISPR 14-2(Edition 2.0): 2015 RLVCISPR 24?(2nd Edition):(2010-08)CISPR 24?(Edition 2.1):(2015-04)CISPR 35 (Edition 1.0) (2016-08)EN 61000-4-6:2009EN 61000-4-6:2014EN 50121-3-2:2015EN 50121-3-2:2017EN 50121-4:2006EN 50121-4:2016EN 55014-2:1997/Amd. 2:2008EN 55014-2:2015EN 55024:2010EN 60601-1-2:2007/AC 2010EN 60601-1-2:2007/AC:2015EN 61000-6-1:2007EN 61000-6-2:2005EN 61326-1:2013EN 62040-2:2006EN 62052-11:2003EN 61547:2009TEC/EMI/TEL-001/01/FEB-09TEC/SD/DD/EMC-221/05/OCT-16Power Frequency Magnetic Field Immunity TestIEC 61000-4-8 (2nd Edition):(2009-09)IEC 60601-1-2 (Edition 3.0):(2007-03)IEC 60601-1-2 (Edition 4.0):(2014-02)IEC 61000-6-1?(2nd Edition):(2005-03)IEC 61000-6-1 (3nd Edition) (2016-08)IEC 61000-6-2?(2nd Edition):(2005-01)IEC 61000-6-2 (3nd Edition)(2016-08)IEC 61326-1?(2nd Edition):(2012-07)IEC 62040-2?(2nd Edition):(2005-10)IEC 61547 2009IEC 61850-3 (Edition 2.0) 2013-12CISPR 24?(2nd Edition):(2010-08)CISPR 24?(Edition 2.1):(2015-04)IEEE Std 1613.1 2013CISPR 35 (Edition 1.0) (2016-08)EN 61000-4-8:2010EN 55024:2010EN 60601-1-2:2007/AC 2010EN 60601-1-2:2007/AC:2015EN 61000-6-1:2007EN 61000-6-2:2005EN 61326-1:2013EN 62040-2:2006EN 61547:2009Voltage Dips, Short Interruption & Voltage variations Immunity TestIEC 61000-4-11 (2nd Edition):(2004-03)IEC 61000-4-11 (2.1 Edition):(2017-05)IEC 60601-1-2? (Edition 3.0):(2007-03)IEC 60601-1-2 (Edition 4.0) (2014-02)IEC 61000-6-1?(2nd Edition):(2005-03)IEC 61000-6-1 (3nd Edition) (2016-08)IEC 61000-6-2?(2nd Edition):(2005-01)IEC 61000-6-2 (3nd Edition)(2016-08)IEC 61326-1?(2nd Edition):(2012-07)IEC 62052-11?(Edition 1.0):(2003-02)IEC 61547:2009IEC 61850-3 (Edition 2.0) 2013-12IEC 60974-10:2014/AMD1:2015CISPR 14-2(Edition 2.0): 2015 RlvCISPR 24 (2nd Edition):(2010-08) CISPR 24?(Edition 2.1):(2015-04)CISPR 35 (Edition 1.0) (2016-08)EN 61000-4-11:2004EN 55014-2:1997 Amd. 2:2008EN 55014-2:2015EN 55024:2010EN 60601-1-2:2007/AC. 2010EN 60601-1-2:2007/AC:2015EN 61000-6-1:2007EN 61000-6-2:2005EN 61326-1:2013EN 62040-2:2006TEC/EMI/TEL-001/01/FEB-09TEC/SD/DD/EMC-221/05/OCT-16EN 62052-11:2003/EN 61547:2009?Ring wave Immunity TestIEC 61000-4-12:2006IEC 61000-4-12:( Ed 3.0) 2017-07EN 61000-4-12:RMATION TECHNOLOGY EQUIPMENT1.Power adaptors, Mobile Phone, Cash Register, Point of Sale Terminal, Copying Machine, Franking Machine, Passport reader, Computer Systems, Printers Scanners, iris scanner, Optical finger print scanner, USB driven Barcode readers, barcode scanners,Smart watches CCTV Cameras/Equipment for CCTV Cameras . Keyboards, Automatic Data Processing Machine, Set top Box.Input TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 1.6.2)Thermal requirementIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 4.5.1)Overload of operator accessible PartsIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 5.3.7)Humidity conditioningIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 2.9.1)Electric strength TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 5.2.2)Touch current TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 5.1)Abnormal operation TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 5.3.1)Capacitance discharge TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 2.1.1.7)Limited power source measurement TestIS 13252 (Part 1):2010 + Amd. 1: 2013 +Amd. 2:2015 (Clause. 2.5)Working voltage determinationIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 2.10.2)Protective bonding Test IIIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 2.6.3.4)Limited current circuit measurementIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 2.4.1)Limitation of touch current to a telecommunication and cable distribution systemIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 5.1.8.1)Requirement of separation between telecommunication network from earthIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 6.1.2)Steady force TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 4.2.1)Impact TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 4.2.5)Strain relief TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 3.2.6)Cord guard TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 3.2.8)Hazardous moving Parts TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 4.4.2)Stability TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 4.1)Durability of marking TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 1.7.11)Stress relief TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 4.2.7)Drop TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 4.2.6)2.Power adaptors, Mobile Phone, Cash Register, Point of Sale Terminal, Copying Machine, Franking Machine, Passport reader,Computer Systems, Printers Scanners, Keyboards, & Automatic Data Processing Machine, Set top BoxInput TestUL 60950-1 (2nd Edition):2007 CSA C22.2 No. 60950-1 (2nd Edition):Date. 2007/03/27 IEC 60950-1 ( (2nd Edition):2005+ Amd. 1 Date. 2009-12-01 (Clause. 1.6.2) UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/ IEC 60950-1:2001 (1st Edition) (Clause. 1.6.2)Thermal requirementUL 60950-1 (2nd Edition):2007 CSA C22.2 No.60950-12nd Edition):Date. 2007/03/27IEC 60950-1 (2nd Edition):2005-12-01 + Amd.1 Date. 2009-12-01(Clause. 4.5.1) UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/IEC 60950-1(1st Edition): 2001 (Clause. 4.5.1)Output overload TestUL 60950-1 (2nd Edition):2007/03/27 CSA C22.2 No.60950-1(2nd Edition):Date. 2007/03/27IEC 60950-1 (2nd Edition):2005/12/01+ Amd. 1 Date. 2009-12-01 (Clause. 5.3.7) UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/ IEC 60950-1 (1st Edition):2001Dielectric strength TestUL 60950-1 (2nd Edition):2007/03/27CSA C22.2 No.60950-1(2nd Edition) Date. 2007/03/27IEC 60950-1 (2nd Edition):2005/12/01 + Amd.1 Date. 2009-12-01 (Clause. 5.2.2)UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/IEC 60950-1(1st Edition):2001(Clause. 5.2)Touch current TestUL 60950-1 (2nd Edition): 2007CSA C22.2 No.60950-1(2nd Edition):Date. 2007/03/27IEC 60950-1 (2nd Edition):2005 + Amd. 1 Date. 2009-12-01 (Clause. 5.1)UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/IEC 60950-1 (1st Edition):2001(Clause. 5.1)Output short circuit TestUL 60950-1 (2nd Edition):2007/03/27CSA C22.2 No.60950-1(2nd Edition):Date. 2007/03/27IEC 60950-1 (2nd Edition):2005/12/01 + Amd. 1 Date. 2009-12-01 (Clause. 5.3.7)UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/ IEC 60950-1 (1st Edition):2001(Clause. 5.3.7) Abnormal operation TestUL 60950-1 (2nd Edition):2007/03/27CSA C22.2 No.60950-1 (2nd Edition):Date. 2007/03/27 IEC 60950-1 (2nd Edition):2005 + Amd. 1 Date. 2009-12-01 (Clause. 5.3.3) UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/ IEC 60950-1(1st Edition):2001 (Clause. 5.3.1) Component failure TestUL 60950-1 (2nd Edition):2007/03/27CSA C22.2 No.60950-1(2nd Edition):Date. 2007/03/27IEC 60950-1 (2nd Edition):2005/12/01 + Amd. 1 Date. 2009-12-01 (Clause. 5.3.1)UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/ IEC 60950-1 (1st Edition):2001(Clause. 5.3.1)SELV reliability TestUL 60950-1 (2nd Edition):2007/03/27 CSA C22.2 No.60950-1(2nd Edition):Date. 2007/03/27IEC 60950-1 (2nd Edition):2005/12/01 + Amd. 1 Date. 2009-12-01 (Clause. 2.2.2)UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/IEC 60950-1 (1st Edition):2001(Clause. 2.2.2)Max. V, VA, A measurement TestUL 60950-1 (2nd Edition):2007/03/27 CSA C22.2 No.60950-1(2nd Edition):Date. 2007/03/27IEC 60950-1:(2nd Edition):2005-12-01+ Amd.1 Date. 2009-12-01 (Clause. 1.2.2.1)UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/ IEC 60950-1:2001 (1st Edition)(Clause. 1.2.2.1)Capacitance discharge TestUL 60950-1 (2nd Edition):2007 CSA C22.2 No.60950-1(2nd Edition):Date. 2007/03/27IEC 60950-1 (2nd Edition):2005 + Amd.1 Date. 2009-12-01 (Clause. 2.1.1.7)UL 60950-1 (1st Edition):2006/ CSA C22.2 No.60950-1-03/ IEC 60950-1 (1st Edition):2001 (Clause. 2.1.1.7)Energy hazard measurement TestUL 60950-1 (2nd Edition):2007/03/27 CSA C22.2 No.60950-1(2nd Edition):Date. 2007/03/27IEC 60950-1 (2nd Edition):2005/12/01 + Amd.1 Date. 2009-12-01 (Clause. 2.1.1.8)UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/ IEC 60950-1:2001 (1st Edition):(Clause. 2.1.1.8)Limited power source measurement TestUL 60950-1 (2nd Edition):2007/03/27CSA C22.2 No.60950-1 (2nd Edition):Date. 2007/03/27IEC 60950-1 (2nd Edition):2005/12/01 + Amd.1 Date. 2009-12-01 (Clause. 2.5)UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/ IEC 60950-1 (1st Edition):2001 (Clause. 2.5)Working voltage measurement TestUL 60950-1 (2nd Edition):2007/03/27CSA C22.2 No.60950-1(2nd Edition):Date. 2007/03/27IEC 60950-1 (2nd Edition):2005-12-01+ Amd.1 Date. 2009-12-01 (Clause. 2.10.2)UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/ IEC 60950-1:2001 (1st Edition):(Clause. 2.10.2)Transformer and wire insulation electric strength TestUL 60950-1 (2nd Edition):2007CSA C22.2 No.60950-1 (2nd Edition): Date. 2007/03/27 IEC 60950-1 (2nd Edition):2005/12/01 + Amd.1 Date. 2009-12-01 (Clause. 2.10.5.13) UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/ IEC 60950-1:2001 (1st Edition):(Clause. 2.10.5.13)Steady force TestUL 60950-1 (2nd Edition):2007CSA C22.2 No.60950-1(2nd Edition):Date. 2007/03/27 IEC 60950-1 (2nd Edition):2005/12/01+ Amd.1 Date. 2009-12-01 (Clause. 4.2.1)UL 60950-1 (1st Edition): 2006/07/07 CSA C22.2 No.60950-1-03/ IEC 60950-1 (1st Edition):2001 (Clause. 4.2.1) Impact TestUL 60950-1 (2nd Edition):2007CSA C22.2 No.60950-1 (2nd Edition):Date. 2007/03/27 IEC 60950-1 (2nd Edition):2005/12/01 + Amd.1 Date. 2009-12-01 (Clause. 4.2.5)UL 60950-1 (1st Edition):2006/07/07 CSA C 22.2 No.60950-1-03/ IEC 60950-1 (1st Edition):2001(Clause. 4.2.5)Stress relief TestUL 60950-1 (2nd Edition):2007CSA C22.2 No.60950-1(2nd Edition)Date. 2007/03/27IEC 60950-1 (2nd Edition):2005/12/01 + Amd.1 Date. 2009-12-01 (Clause. 4.2.7)UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/ IEC 60950-1(1st Edition):2001 (Clause. 4.2.7)3.Power adaptors, Mobile Phone, Cash Register, Point of Sale Terminal, Copying Machine, Franking Machine, Passport reader,Computer Systems, Printers Scanners, Keyboards, Automatic Data Processing Machine, Set top Box (Thermoplastic, Thermoset,Composite Material)Ball pressure TestUL 60950-1 (2nd Edition):2007 CSA C22.2 No.60950-1 (2nd Edition):Date. 2007/03/27IEC 60950-1 (2nd Edition):2005/12/01+ Amd.1 Date. 2009-12-01(Clause. 4.5.5) UL 60950-1 (1st Edition):2006 /CSA C22.2 No.60950-1-03/IEC 60950-1(1st Edition):2001 (Clause. 4.5.5)Accessible connector overload TestUL 60950-1 (2nd Edition):2007 CSA C22.2 No.60950-1(2nd Edition):Date. 2007/03/27 IEC 60950-1 (2nd Edition): 2005/12/01 + Amd.1 Date. 2009-12-01(Clause. 5.3.7)UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/ IEC 60950-1 (1st Edition):2001 (Clause. 5.3.7)Earthing TestUL 60950-1 (2nd Edition):2007CSA C22.2 No.60950-1(2nd Edition):Date. 2007/03/27IEC 60950-1 (2nd Edition):2005/12/01 + Amd.1 Date. 2009-12-01(Clause. 2.6.3.4)UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/ IEC 60950-1 (1st Edition):2001 (Clause. 2.6.3.4)Limited power source measurement TestUL 60950-1 (2nd Edition):2007 CSA C22.2 No.60950-1(2nd Edition):Date. 2007/03/27 IEC 60950-1 (2nd Edition): 2005/12/01+ Amd.1 Date. 2009-12-01 (Clause. 2.5)UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/ IEC 60950-1 (1st Edition):2001 (Clause. 2.5)Stability TestUL 60950-1 (2nd Edition):2007 CSA C22.2 No.60950-1(2nd Edition): Date. 2007/03/27 IEC 60950-1 (2nd Edition):2005/12/01 + Amd.1 Date. 2009-12-01 (Clause. 4.1)UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/IEC 60950-1 (1st Edition):2001(Clause. 4.1) Component failure TestUL 60950-1 (2nd Edition):2007 CSA C22.2 No.60950-1(2nd Edition):Date. 2007/03/27 IEC 60950-1 (2nd Edition):2005/12/01 + Amd.1 Date. 2009-12-01 (Clause. 5.3.1)UL 60950-1 (1st Edition):2006/07/07 CSA C22.2 No.60950-1-03/ IEC 60950-1 (1st Edition):2001 (Clause. 5.3.1)4.Desktop Computer, Notebook computers, Tablets, Small-scale servers, Thin Client, Workstations and MonitorsOff modeENERGY STAR Computer Test Method, Version 6.1 UUT preparation shall be performed according to IEC 62623 (Edition 1.0):2012-10, Section 5.2:Test SetupSleep ModeENERGY STAR Computer Test Method, Sleep Mode power shall be measured according to IEC 62623 (Edition 1.0):201210, Section 5.3.3:Measuring Sleep ModeIdle StateENERGY STAR Computer Test Method, Long Idle Mode power shall be measured according to IEC 62623 (Edition 1.0):2012-10, (Section 5.3.4):Measuring Long Idle ModeActive StateENERGY STAR Computer Test Method, Short Idle Mode power shall be measured according to IEC 62623 (Edition 1.0):2012-10, (Section 5.3.5):Measuring Short Idle ModeIdle StateENERGY STAR Test Method for Computer Servers,Off Mode power shall be measured according to IEC 62623 (Edition 1.0):2012-10, (Section 5.3.2):Measuring Off ModeFull LoadENERGY STAR Test Method for Computer Servers, ENERGY STAR Program Requirements Product Specification for Computer Servers, Version 1.1, Appendix A5.Energy efficiency of Internal/External AC-DC and DC-DC Power suppliesActive Mode power consumption):for single Output power supplyGeneralized Test Protocol for calculating the Energy Efficiency of Internal AC-DC and DC-DC Power supplies:Revision 6.4.2, 22nd October 2008 & Revision 6.5, July 07, 2010. according to IEC 62623 (Edition 1.0):2012-10Test Method for Calculating the Energy Efficiency of Single-Voltage External Ac-Dc and AC-AC Power Supplies August 11, 2004.Active Mode power consumption for multiple Output power supplyGeneralized Test Protocol for calculating the Energy Efficiency of Internal AC-DC and DC-DC Power supplies:Revision 6.4.2, 22nd October 2008 & Revision 6.5, July 07, 2010.According to IEC 62623 (Edition 1.0): 2012-10Test Method for Calculating the Energy Efficiency of Single-Voltage External AC-DC and AC-AC Power Supplies August 11, 2004Standby Mode Power consumptionGeneralized Test Protocol for calculating the Energy Efficiency of Internal AC-DC and DC-DC Power supplies:Revision 6.4.2, 22nd October 2008 & Revision 6.5, July 07, 2010.according to IEC 62623 (Edition 1.0):2012-10Test Method for Calculating the Energy Efficiency of Single-Voltage External AC-DC and AC-AC Power Supplies August 11, 2004.6.Cash Register, Point of Sale Terminal, Copying Machine, Franking Machine, Passport reader, Computer Systems, Printers Scanners, Telephones & Automatic Data Processing MachineTNV Circuits, LimitsIS 13252 (Part 1):2010 +Amd. 1:2013 +Amd. 2:2015Cl. 2.3, 2.3.1Separation of TNV Ckts from other ckts & from accessible parts Protection by basic Insulation, Protection by Earthing, protection by other constructionsIS 13252 (Part 1):2010 +Amd. 1:2013 +Amd. 2:2015Cl 2.3.2, 2.3.2.1, 2.3.2.2, 2.3.2.3 2.3.2.4Separation from hazardous voltagesIS 13252 (Part 1):2010 +Amd. 1:2013 +Amd. 2:2015Cl 2.3.3Connection of TNV circuits to other circuitsIS 13252 (Part 1):2010 +Amd. 1:2013 +Amd. 2:2015Cl 2.3.4Test for operating Voltages generated externallyIS 13252 (Part 1):2010 +Amd. 1:2013 +Amd. 2:2015Cl 2.3.57.Power adaptors, Mobile Phone, Cash Register, Point of Sale Terminal, Copying Machine, Franking Machine, Passport reader, Computer Systems, Printers Scanners, iris scanners, Keyboards, Automatic Data Processing Machine, Set top BoxComponents- Thermal controlsIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015, CL 1.5.3Components- TransformersIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 1.5.4Components- Interconnecting cablesIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 1.5.5Components- Capacitors bridging insulationIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 1.5.6Components - Resistors bridging double insulation or reinforced insulation between the a.c.mains supply and other circuitsIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,1.5.7.2Access to energized partsIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.1.1.1Access to ELV wiringAmd. 1:2013 +Amd.,CL 2.1.1.3Access to hazardous voltage wiringIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.1.1.4Energy hazardIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.1.1.5Energy hazards-d.c. main suppliesIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.1.1.8Audio amplifiers in IT EquipmentIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.1.1.9SELV CircuitsIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.2, 2.2.1-2.2.4TNV CircuitsIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.2, 2.3, 2.3.1-2.3.5Short Circuit backup protectionIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.2, 2.7.3Number and location of protective deviceIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.2, 2.7.4Safety Interlocks, Protection requirements, Inadvertent reactivationIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.8.2-2.8.8Creepage/clearance/distance through insulation, peak working voltageIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.10, 2.10.2.3Clearances, Measurement of transient voltages, Clearances in secondary circuitsIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.10.3, 2.10.3.9.2, 2.10.3.4Creepage distancesIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.10.4Solid Insulation, non-separable thin sheet material IS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.10.5-2.10.5.14Construction of Printed BoardsIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.10.6.2-2.10.6.4Semiconductor DevicesIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.10.5.4Thermal cycling & thermal ageingIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.10.9Electric Strength TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.10.8.3Abrasion Resistance testIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.10.8.4Test for pollution Degree 1 environment and for insulating compoundIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.10.10Enclosed and sealed partsIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 2.10.12Insulation of conductor, Termination of conductorIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 3.1.4, 3.1.9Permanently connected equipment, Appliance inletsIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd.,CL 3.2.3, 3.2.4Steady Force TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 4.2.3,4.2.4)Wall or ceiling mounted equipmentIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 CL4.2.10handles & manual controlsIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015,CL4.3.2,4.3.3BatteriesIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015, Cl. 4.3.8Resistance to abnormal heatIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015,CL4.5.5Top and Side openings.Bottoms of fire enclosures.IS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015,CL4.6.1,4.6.2Evaluation measure of larger openingsIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015,CL4.6.4.2Adhesives for constructionalIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015,CL4.6.5Resistance to fire purposesIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015Cl.4.7, 4.7.1, 4.7.2, 4.7.2.1, 4.7.2.2Materials for fire enclosuresIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 (Clause. 4.7.3,4.7.3.2)Materials used in high voltage componentsIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015 CL4.7.3.6Abnormal operating and fault conditionsIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015,CL5.3.2, 5.3.3, 5.3.4, 5.3.5, 5.3.6, 5.3.7, 5.3.8, 5.3.9.1, 5.3.9.2Protection of equipment users from over voltages on telecommunication networkIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015,CL6.2.1, 6.2.2,6.2.2.1,6.2.2.2Protection of the telecommunication wiring system from overheatingIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015, Cl. 6.3Connection to cable distribution SystemsIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015,CL7.2,7.3Surge TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015,CL7.4.2Impulse TestIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015,CL6.2,7.4.3Motor tests under abnormal conditionsTransformersIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015,Annex CComponent flammabilityIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015,Annex Q8.Mobile PhonesLanguage Input test & VerificationIS 16333 (Part 3):2017, Cl 59.Radio Transmitting EquipmentFault conditions TestsIEC 60215 (Edition 4):2016-04IS 10437:1986, (RA 2015)Resistance To HumidityIEC 60215 (Edition 4):2016-04IS 10437:1986, (RA 2015)Resistance to Ingress of WaterIEC 60215 (Edition 4):2016-04IS 10437:1986, (RA 2015)Protection against electric shockIEC 60215 (Edition 4):2016-04IS 10437:1986, (RA 2015)Protection against electric shock-Opening in enclosureIEC 60215 (Edition 4):2016-04IS 10437:1986, (RA 2015)High TemperaturesIEC 60215 (Edition 4):2016-04IS 10437:1986, (RA 2015)Creepage and Clearance distancesIEC 60215 (Edition 4):2016-04IS 10437:1986, (RA 2015)Ionizing radiationIEC 60215 (Edition 4):2016-04IS 10437:1986, (RA 2015)10.Automatic Data Processing Machine, Laptop/Notebook/ Tablet, Printers, Plotters, Scanners, Set Top Box, Telephone Answering Machines, Visual Display Units, Videos Monitors, Wireless Keyboards, Cash Registers, Copying Machines/ Duplicators, Passport Reader, Point Of Sale Terminals, Mail Processing Machines/ Postage Machines/ Franking Machines, Power Banks For Use In Portable Applications, Smart Card Reader, Mobile Phones, Power Adaptors, CCTV Cameras/ CCTV Recorders, USB Driven Barcode Reader, Barcode Scanners/Iris Scanners/ Optical Fingerprint Scanners, Smart Watches, Computer SystemsDirect plug in equipmentIS 13252 (Part 1): 2010 +Amd. 1: 2013 +Amd. 2: 2015, (Clause 4.3.6)III.AUDIO/ VIDEO COMPONENTS AND PRODUCTS1.House Hold Electronic Appliances-CRT TV; LCD; Plasma displaysStandby power measurementIEC 62301 (Edition 2):2011-01/IS 13384 (Part 1):1992 IS 13384 (Part 2):1997On mode Power measurementIEC 62087 (Edition 3):2011-04IS 13384 (Part 1):1992IS 13384 (Part 2):19972. Power adaptor, Televisions, Optical Disc Players, Amplifier, Electronic Musical SystemNormal operating conditions-Input TestEN/IEC 60065:2014, Clause. 4.2 IS 616:2017-Rev 5, Clause. 4.1 to 4.3Marking LegibilityEN/IEC 60065:2014, Clause. 5 IS 616:2017-Rev 5, Clause. 5Heating under normal operating conditionsEN/IEC 60065:2014, Clause. 7 IS 616:2017-Rev 5, Clause. 7Hygroscopic materialsEN/IEC 60065:2014, Clause. 8.3 IS 616:2017-Rev 5, Clause. 8.3Winding insulation TestEN/IEC 60065:2014, Clause. 8.8IS 616:2017-Rev 5, Clause. 8.8External forces-windows & coversEN/IEC 60065:2014, Clause. 8.13, 8.14 IS 616:2017-Rev 5, Clause. 8.13, 8.14Internal forcesEN/IEC 60065:2014, Clause. 8.15IS 616:2017-Rev 5, Clause. 8.15Determination of hazardous live PartsEN/IEC 60065:2014, Clause. 9.1.1.1 IS 616:2017-Rev 5, Clause. 9.1.1.1Protection):against electric shock-AccessibilityEN/IEC 60065:2014, Clause. 9, 9.1.1.2, 9.2 IS 616:2017-Rev 5, Clause. 9, 9.1.1.2, 9.2Protection against electric shock-Opening in enclosureEN/IEC 60065:2014, Clause. 9.1.3 IS 616:2017-Rev 5, Clause. 9.1.3Protection against electric shock-TerminalsEN/IEC 60065:2014, Clause. 9.1.4 IS 616:2017-Rev 5, Clause. 9.1.4Preset controlsEN/IEC 60065:2014, Clause. 9.1.5IS 616:2017-Rev 5, Clause. 9.1.5Withdrawal of main plugEN/IEC 60065:2014, Clause. 9.1.6IS 616:2017-Rev 5, Clause. 9.1.6Resistance to external forcesEN/IEC 60065:2014, Clause. 9.1.7IS 616:2017-Rev 5, Clause. 9.1.7Surge TestEN/IEC 60065:2014, Clause. 10.1IS 616:2017-Rev 5, Clause. 10.1Humidity treatmentEN/IEC 60065:2014, Clause. 10.2 IS 616:2017-Rev 5, Clause. 10.2Insulation resistanceEN/IEC 60065:2014, Clause. 10.3IS 616:2017-Rev 5, Clause. 10.3Dielectric strengthEN/IEC 60065:2014, Clause. 10.3IS 616:2017-Rev 5, Clause. 10.3Fault conditions TestsEN/IEC 60065:2014, Clause. 11IS 616:2017-Rev 5, Clause. 11Mechanical strength-BumpEN/IEC 60065:2014, Clause. 12.1.1IS 616:2017-Rev 5, Clause. 12.1.1Mechanical strength-ImpactEN/IEC 60065:2014, Clause. 12.1.3Impact Hammer:Impact steel ball: IS 616:2017-Rev 5, Clause. 12.1.3Drop TestEN/IEC 60065:2014, Clause. 12.1.4IS 616:2017-Rev 5, Clause. 12.1.4Mechanical strength-Stress reliefEN/IEC 60065:2014, Clause. 12.1.5IS 616:2017-Rev 5, Clause. 12.1.5Torque Test-Rod antennaEN/IEC 60065:2014,Clause. 12.6IS 616:2017-Rev 5, Clause. 12.6Creepage and Clearance distancesEN/IEC 60065:2014, Clause. 13IS 616:2017-Rev 5, Clause. 13Determination of operating voltageEN/IEC 60065:2014, Clause. 13.2IS 616:2017-Rev 5, Clause. 13.2Component-ResistorsEN/IEC 60065:2014, Clause. 14.1IS 616:2017-Rev 5, Clause. 14.1Provisions for protective resistanceEN/IEC 60065:2014, Clause. 15.2IS 616:2017-Rev 5, Clause. 15.2Strain relief TestEN/IEC 60065:2014, Clause. 16.5IS 616:2017-Rev 5, Clause. 16.5Torque Test on screw terminalsEN/IEC 60065:2014, Clause. 17.1IS 616:2017-Rev 5, Clause. 17.1Torque Test on coversEN/IEC 60065:2014, Clause. 17.7IS 616:2017-Rev 5, Clause. 17.7Stability TestEN/IEC 60065:2014, Clause. 19.1IS 616:2017-Rev 5, Clause. 19.1Vertical force stabilityEN/IEC 60065:2014, Clause. 19.2IS 616:2017-Rev 5, Clause. 19.2Horizontal force stabilityEN/IEC 60065:2014, Clause. 19.3IS 616:2017-Rev 5, Clause. 19.3Wall or Ceiling or Equipment Rack Mounting TestEN/IEC 60065:2014, Clause. 19.6IS 616:2017-Rev 5, Clause. 19.6Resistance to Heat, Fire and Tracking (Glow wire Test)EN/IEC 60065:2014, Clause. 20, Annexure. GIS 616:2017-Rev 5, Clause. 20, Annexure. GResistance to Heat, Fire and Tracking (Needle flame)EN/IEC 60065:2014, Clause. 20, Annexure. GIS 616:2017-Rev 5, Clause. 20, Annexure. GResistance to Heat, Fire and Tracking (Flame Test)EN/IEC 60065:2014, Clause. 20, Annexure. G3.Audio Video and Similar Electronic Apparatus-Safety Requirements-Plasma/LCD/LED TVs, Optical disc players, Amplifier, Musical Systems, Electronic Video Games, Power Adaptors for audio, Video and Similar Electronic ApparatusRequirements for the mounting means of rack-mounted equipmentIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015,Annex DDHousehold and home/office document/media shreddersIS 13252 (Part 1):2010 + Amd. 1:2013 +Amd. 2:2015,Annex EEProtection against electric shockEN/IEC 60065:2014, Clause 8.17-8.21,IS 616:2017-Rev 5, Clause 8.17-8.21Vibration TestEN/IEC 60065:2014, Clause 12.1.3,IS 616:2017-Rev 5, Clause 12.1.3DrawersEN/IEC 60065:2014, Clause 12.4,IS 616:2017-Rev 5, Clause 12.4Antenna coaxial sockets mounted on the apparatusEN/IEC 60065:2014, Clause 12.5,IS 616:2017-Rev 5, Clause 12.5Creepage Distances(Tracking Index test)EN/IEC 60065:2014, Clause 13.4,IS 616:2017-Rev 5, Clause 13.4Devices forming a part of the MAINS plugEN/IEC 60065:2014, Clause 15.4,IS 616:2017-Rev 5, Clause 15.44.Audio/Video, Information and Communication Technology EquipmentFixing ConductorEN 62368-1 (Clause 4.6)IEC 62368-1(ed 2:2014) (Clause 4.6)Equipment for direct insertion into mains socket-outletsEN 62368-1 (Clause 4.7)IEC 62368-1 (ed 2:2014) (Clause 4.7)Stress relief test EN 62368-1 (Annex T.8)IEC 62368-1 (ed 2:2014) (Annex T.8)Drop test EN 62368-1 (Annex T.7)IEC 62368-1 (ed 2:2014) (Annex T.7) Crush test EN 62368-1 (Clause 4.8.4.6) IEC 62368-1(ed 2:2014) (Clause 4.8.4.6) Compliance criteria(Force test)EN 62368-1 (Clause 4.8.5)IEC 62368-1(ed 2:2014) (Clause 4.8.5) Accessibility to electrical energy sources and safeguardsEN 62368-1 (Clause 5.3.2)IEC 62368-1(ed 2:2014) (Clause 5.3.2)Maximum operating temperature (Temperature measurement)EN 62368-1 (Clause 5.4.1.4)IEC 62368-1 (ed 2:2014)(Clause 5.4.1.4) RMS working voltage / Peak working voltage (working voltage)EN 62368-1 (Clause 5.4.1.8.2 / 5.4.1.8.3)IEC 62368-1(ed 2:2014) (Clause 5.4.1.8.2 / 5.4.1.8.3) Vicat softening testEN 62368-1 (Clause 5.4.1.10.2)IEC 62368-1 (ed 2:2014)(Clause 5.4.1.10.2)Ball pressure test EN 62368-1 (Clause 5.4.1.10.3)IEC 62368-1(ed 2:2014)(Clause 5.4.1.10.3)Clearance, creepage EN 62368-1 (Clause 5.4.2, 5.4.3)IEC 62368-1 (ed 2:2014)(Clause 5.4.2, 5.4.3)Antenna Terminal InsulationEN 62368-1 (Clause 5.4.5)IEC 62368-1(ed 2:2014) (Clause 5.4.5) Humidity conditioningEN 62368-1 (Clause 5.4.8)IEC 62368-1(ed 2:2014) (Clause 5.4.8) Electric strength testEN 62368-1 (Clause 5.4.9)IEC 62368-1 (ed 2:2014) (Clause 5.4.9) Impulse test EN 62368-1 (Clause 5.4.10.2.2)IEC 62368-1 (ed 2:2014)(Clause 5.4.10.2.2) Steady-state test (electric strength test)EN 62368-1 (Clause 5.4.10.2.3)IEC 62368-1 (ed 2:2014)(Clause 5.4.10.2.3) Capacitor dischargeEN 62368-1 (Clause 5.5.2.2)IEC 62368-1 (ed 2:2014)(Clause 5.5.2.2) Resistance of the Protective Bonding System (Earth bond test)EN 62368-1 (Clause 5.6.6)IEC 62368-1(ed 2:2014) (Clause 5.6.6) Prospective touch voltage, touch current and protective conductor currentEN 62368-1 (Clause 5.7)IEC 62368-1(ed 2:2014) (Clause 5.7) Power source circuit classification EN 62368-1 (Clause 6.2.2)IEC 62368-1 (ed 2:2014) (Clause 6.2.2)Static stability EN 62368-1 (Clause 8.6.2)IEC 62368-1(ed 2:2014) (Clause 8.6.2)Horizontal force testEN 62368-1 (Clause 8.6.5)IEC 62368-1 (ed 2:2014) (Clause 8.6.5)Equipment mounted to a wall or ceilingEN 62368-1 (Clause 8.7)IEC 62368-1(ed 2:2014) (Clause 8.7)Handle strengthEN 62368-1 (Clause 8.8)IEC 62368-1(ed 2:2014) (Clause 8.8)Cart, stand or carrier loading test EN 62368-1 (Clause 8.10.3)IEC 62368-1 (ed 2:2014)Input test (Clause 8.10.3)EN 62368-1 (Annex B.2.5)IEC 62368-1 (Annex B.2.5)Simulated abnormal operating conditions / Simulated single fault conditionsEN 62368-1 (Annex B.2.5)IEC 62368-1(ed 2:2014) (Annex B.2.5)Test for the permanence of marking EN 62368-1 (Annex F.3.9)IEC 62368-1 (ed 2:2014) (Annex F.3.9)Mains supply connection (Cord anchorage)EN 62368-1 (Annex G.7)IEC 62368-1 (ed 2:2014) (Annex G.7)Criteria for telephone ringing signals (TNV circuit test)EN 62368-1 (Annex H)IEC 62368-1 (ed 2:2014) (Annex H)Leakage CurrentEN 62368-1 (Annex M.6.2)IEC 62368-1(ed 2:2014) (Annex M.6.2)Limited power sourceEN 62368-1 (Annex Q.1)IEC 62368-1(ed 2:2014) (Annex Q.1)Steady force test EN 62368-1 (Annex T.2)IEC 62368-1(ed 2:2014) (Annex T.2)Steady force test EN 62368-1 (Annex T.3)IEC 62368-1(ed 2:2014) (Annex T.3)Steady force test EN 62368-1 (Annex T.4)IEC 62368-1(ed 2:2014) (Annex T.4)Steady force test EN 62368-1 (Annex T.5)IEC 62368-1(ed 2:2014) (Annex T.5)Enclosure impact test EN 62368-1 (Annex T.6)IEC 62368-1 (ed 2:2014) (Annex T.6)Impact testEN 62368-1 (Annex T.9)IEC 62368-1 (ed 2:2014) (Annex T.9)5.Audio video and similar electronic apparatus-safety requirements-Plasma/LCD/LED TVs, Optical disc players, Amplifier, Musical Systems, Electronic video games, Power adapter for audio, video and similar electronic apparatusNon-Separable Thin Sheet Insulation TestEN/IEC 60065:2014, (Clause 8.21)IS 616: 2017-Rev 5, (Clause 8.21)Fixing Of Actuating ElementsEN/IEC 60065:2014, (Clause 12.2)IS 616: 2017-Rev 5, (Clause 12.2)Apparatus containing coin/button cell batteries-Crush testEN/IEC 60065:2014, (Clause 12.7.3.6)IS 616: 2017-Rev 5, (Clause 12.7.3.6)Test of Edges and cornersEN/IEC 60065:2014, (Clause 19.5)IS 616: 2017-Rev 5, (Clause 19.5)Apparatus to be connected to the telecommunication networksEN/IEC 60065:2014,Annexure BIS 616: 2017-Rev 5, Annexure BInsulated winding wires for use without interleaved insulationEN/IEC 60065:2014, Annexure HIS 616: 2017-Rev 5, Annexure HAlternative method for determining minimum clearancesEN/IEC 60065:2014, Annexure J, IS 616: 2017-Rev 5, Annexure JImpulse test generators EN/IEC 60065:2014, Annexure KIS 616: 2017-Rev 5, Annexure KV.MEDICAL ELECTRICAL EQUIPMENT 1.Applied Electromagnetic radiation equipment; Applied Current/Energy Equipment;Ultrasound Equipment; Cardio, Vascular and Pulmonary Equipment; General Medical Equipment; Patient-monitoring Equipment Document ReviewIEC 60601-1-6 (3rd Edition):2010 ENVIRONMENTAL Test conditions of transport and storageIEC 60601-1-11 (1st Edition):2010 Sub-Clause. 4.2.1ENVIRONMENTAL Test operation conditionIEC 60601-1-11 (1st Edition): 2010 Sub-Clause. 4.2.2Harmful Ingress of Liquids Test?IEC 60601-1-11 (1st Edition):2010/Sub-Clause. 8.3FREE FALL Test??IEC 60601-1-11 (1st Edition):2010 Sub Clause:10.1.3d?2.Ambulatory Electrocardiographic SystemDrop Impact Test IEC 60601-2-47 (2nd Edition):2012 Sub Clause. 201.15.3.4.2Linearity and dynamic rangeIEC 60601-2-47 (2nd Edition):2012 Sub Clause. 201.12.4.4.101??Input Impedance?IEC 60601-2-47 (2nd Edition):2012Sub Clause. 201.12.4.4.102Common Mode Rejection?IEC 60601-2-47 (2nd Edition):2012Sub Clause. 201.12.4.4.103Gain AccuracyIEC 60601-2-47 (2nd Edition):2012Sub Clause. 201.12.4.4.104Multichannel CrosstalkIEC 60601-2-47 (2nd Edition):2012 Sub Clause. 201.12.4.4.107Frequency ResponseIEC 60601-2-47 (2nd Edition):2012Sub Clause. 201.12.4.4.108Function In the Presence of Pacemaker PulsesIEC 60601-2-47 (2nd Edition):2012Sub Clause. 201.12.4.4.109Timing AccuracyIEC 60601-2-47 (2nd Edition):2012 Sub Clause. 201.12.4.4.110GAIN Settings and Switching?IEC 60601-2-47 (2nd Edition):2012Sub Clause. 201.12.4.4.111.3Applied Electromagnetic radiation equipment; Applied Current/Energy Equipment;Ultrasound Equipment; Cardio, Vascular and Pulmonary Equipment; General Medical Equipment; Patient-monitoring Equipment Power input TestUL 60601-1 (1st Edition):2003 Revision 2006IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995(Clause. 7.1)Voltage limitation Test??UL 60601-1 (1st Edition):2003 Revision 2006IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995(Clause. 15)Earthing and potential equalization Test??UL 60601-1 (1st Edition):2003 Revision 2006IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995(Clause. 18 f)Dielectric voltage withstand Test?UL 60601-1 (1st Edition): 2003 Revision 2006IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995 (Clause. 20.4)Leakage current Test?UL 60601-1 (1st Edition): 2003 Revision 2006IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995(Clause. 19)Temperature Test?UL 60601-1 (1st Edition):2003 Revision 2006IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995(Clause. 42)Humidity conditioning Test?UL 60601-1 (1st Edition):2003 Revision 2006IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995(Clause. 44.5)Abnormal operations and fault conditions Test?UL 60601-1 (1st Edition):2003 Revision 2006IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995(Clause. 52)Marking durability Test?UL 60601-1 (1st Edition):2003 Revision 2006IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995(Clause. 6.1)Enclosure mechanical strength?UL 60601-1 (1st Edition):2003 Revision 2006IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995(Clause. 21a,b)Stability and transportability Test?UL 60601-1 (1st Edition):2003 Revision 2006IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995(Clause. 24)Ball pressure Test?UL 60601-1 (1st Edition):2003 Revision 2006IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995 (Clause. 59.2)Legibility of Markings?IEC 60601-1 (3rd Edition):2005 Amd 1:2012, Clause. 7.1.2IS 13450 (Part 1):2008, Clause. 7.1.2Voltage mismatch?IEC 60601-1 (3rd Edition): 2005, Amd. 1:2012, Clause. 7.2.6IS 13450 (Part 1):2008, Clause. 7.2.6Shorting one MOP?IEC 60601-1 (3rd Edition): 2005, Amd. 1:2012, Clause. 8.1bIS 13450 (Part 1):2008, Clause. 8.1bIncorrect Polarity?IEC 60601-1 (3rd Edition):2005Amd. 1:2012, IS 13450 (Part 1):2008, Clause. 8.2.2Patient Lead Connection?IEC 60601-1 (3rd Edition):2005 Amd. 1:2012, Clause. 8.5.2.3IS 13450 (Part 1):2008, Clause. 8.5.2.3Working Voltage Measurement?IEC 60601-1 (3rd Edition): 2005, Amd. 1:2012, Clause. 8.5.4IS 13450 (Part 1):2008, Clause. 8.5.4Thermal Cycling for spaces filled with insulating material,?IEC 60601-1 (3rd Edition): 2005, Amd. 1:2012, Clause. 8.9.5IS 13450 (Part 1):2008, Clause. 8.9.5Temperature and Overload Control Device?IEC 60601-1 (3rd Edition):2005Amd. 1:2012,Clause. 15.4.2.1IS 13450 (Part 1):2008, Clause. 15.4.2.1Reverse Battery Connection/Overcharging by inspectionIEC 60601-1 (3rd Edition):2005 Amd. 1:2012, Clause. 15.4.3 IS 13450 (Part 1):2008, Clause. 15.4.3Transformer Short Circuit?IEC 60601-1 (3rd Edition):2005 Amd. 1:2012, Clause. 15. 5.1.2IS 13450 (Part 1):2008, Clause. 15. 5.1.2?Amd. 1:2012, Clause. 15.5.1.3IS 13450 (Part 1):2008, Clause. 15.5.1.3Transformer Dielectric Voltage Withstand?IEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 15.5.2IS 13450 (Part 1):2008, Clause. 15.5.2ME System Leakage Current?IEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 16.6.1IS 13450 (Part 1):2008, Clause. 16.6.1Limitation of Voltage, Current or Power?IEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 8.4.2IS 13450 (Part 1):2008, Clause. 8.4.2Defib-Proof Applied Parts- Common mode test?IEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 8.5.5 IS 13450 (Part 1): 2008Defib-Proof Applied Parts- Differential mode testIEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 8.5.5 IS 13450 (Part 1):2008Defib-Proof Applied Parts- Energy Reduction?IEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 8.5.5.2IS 13450 (Part 1):2008, Clause. 8.5.5.2Stability and transportability TestIEC 60601-1 (3rd Edition):2005 Amd. 1:2012, Clause. 9.4.2 IS 13450 (Part 1):2008Cord AnchorageIEC 60601-1 (3rd Edition):2005 Amd. 1:2012, Cl. 8.11.3.5IS 13450 (Part 1):2008, Clause. 8.11.3.5Cord Bending?IEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 8.11.3.6IS 13450 (Part 1):2008, Clause. 8.11.3.6Measurement of Gaps(Trapping Zones)?IEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 9.2.2.2IS 13450 (Part 1):2008, Clause. 9.2.2.2Mobile Equipment Force for Propulsion?IEC 60601-1 (3rd Edition): 2005/Amd. 1:2012, Clause. 9.4.2.4.2IS 13450 (Part 1):2008?Mobile Equipment Over a Threshold?IEC 60601-1 (3rd Edition):2005 Amd. 1:2012, Clause. 9.4.2.4.3IS 13450 (Part 1):2008, Cl. 9.4.2.4.3Instability from Unwanted Lateral Movement(Including Sliding),?IEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 9.4.3.1IS 13450 (Part 1):2008, Clause. 9.4.3.1Handle Loading,?IEC 60601-1 (3rd Edition):2005 Amd 1:2012, Cl. 9.4.4IS 13450 (Part 1):2008, Clause. 9.4.4Mechanical Strength-Patient Support System ?IEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 9.8.3.1IS 13450 (Part 1):2008, Clause. 9.8.3.1Mechanical Strength-Foot Rest ?IEC 60601-1 (3rd Edition):2005 Amd. 1:2012, Clause. 9.8.3.2IS 13450 (Part 1):2008, Clause. 9.8.3.2Mechanical Strength-Dynamic Forces?IEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 9.8.3.3IS 13450 (Part 1):2008, Clause. 9.8.3.3Suspension system w/Safety Devices Loading?IEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 9.8.4IS 13450 (Part 1):2008, Clause. 9.8.4Harmful IngressIEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 11.6.5IS 13450 (Part 1):2008, Clause. 11.6.5?Cleaning and Disinfection of ME Equipment’s and ME Systems?IEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 11.6.6IS 13450 (Part 1):2008, Clause. 11.6.6Actuating Parts of Control of ME Equipment?IEC 60601-1 (3rd Edition): 2005/Amd. 1:2012, Clause. 15.4.6IS 13450 (Part 1):2008, Clause. 15.4.6Cord-Connected Foot Operated Control Devices?IEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 15.4.7.1IS 13450 (Part 1):2008, Clause. 15.4.7.1Short Circuiting in Lieu of Spacing?IEC 60601-1 (3rd Edition):2005 Amd. 1:2012, Clause. 8.9.2IS 13450 (Part 1):2008, 8.9.2Overflow?IEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 11.6.2IS 13450 (Part 1):2008, Clause. 11.6.2?Spillage?IEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 11.6.3IS 13450 (Part 1):2008, Clause. 11.6.3Leakage?IEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 11.6.4IS 13450 (Part 1):2008, Clause. 11.6.4Acoustic Energy Measurement?IEC 60601-1 (3rd Edition):2005Amd. 1:2012, Clause. 9.6.2.1IS 13450 (Part 1):2008, Clause. 9.6.2.1Power input Test?IEC 60601-1 (3rd Edition):2005IS 13450 (Part 1):1994IS 13450 (Part 1):2008 (Clause. 4.11)Voltage or Charge Limitation?IEC 60601-1 (3rd Edition):2005IS13450 (Part 1):2008(Clause. 8.4.3)Impedance and Current Carrying Capability?IEC 60601-1 (3rd Edition):2005IS13450 (Part 1):2008(Clause. 8.6.4a)Dielectric voltage withstand Test?IEC 60601-1 (3rd Edition):2005IS13450 (Part 1):2008(Clause. 8.8)Leakage current Test?IEC 60601-1 (3rd Edition):2005IS13450 (Part 1):2008(Clause. 8.7)Temperature Test?IEC 60601-1 (3rd Edition): 2005/IS13450 (Part 1):2008(Clause. 11)Marking durability Test?IEC 60601-1 (3rd Edition):2005IS13450 (Part 1):2008(Clause. 7.1.3)Humidity conditioning Test?IEC 60601-1 (3rd Edition):2005IS13450 (Part 1):2008(Clause. 5.7)Interruption power supply Test?IEC 60601-1 (3rd Edition):2005IS13450 (Part 1):2008(Clause. 11.8)Abnormal operations and fault conditions TestIEC 60601-1 (3rd Edition): 2005/IS13450 (Part 1):2008(Clause. 13)Enclosure mechanical strength?IEC 60601-1 (3rd Edition):2005IS 13450 (Part 1):2008 (Clause. 15.3)Instability Hazards?IEC 60601-1 (3rd Edition):2005IS 13450 (Part 1):2008 (Clause. 9.4.3)Ball pressure Test?IEC 60601-1 (3rd Edition):2005IS 13450 (Part 1):2008 (Clause. 8.8.4.1)Defibrillation-Proof Applied Parts?IS 13450 (Part 1):1994, Clause. 17IEC 60601-1 (2nd Edition): 1988 AM 1:1991, AM 2:1995, Clause. 17UL 60601-1 (1st Edition): 2003 Revision 2006, Clause. 17Handle Loading Test?IS 13450 (Part 1):1994, Clause. 21IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995, Clause. 21UL 60601-1 (1st Edition):2003Revision 2006,Clause. 21Mechanical Strength-Patient Support System?IS13450 (Part 1):1994, Clause. 21.3IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995, Clause. 21.3UL 60601-1(1st Edition):2003 Revision 2006, Clause. 21.3Mechanical Strength-Foot Rests/Chairs?IS 13450 (Part 1):1994, Clause. 21.3IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995, Clause. 21.3UL 60601-1 (1st Edition):2003 Revision 2006,Clause. 21.3Drop Impact Test?IS 13450 (Part 1):1994, Clause. 21.5IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995, Clause. 21.5UL 60601-1 (1st Edition):2003Revision 2006,Clause. 21.5Rough Handling-Drop Test?IS13450 (Part 1):1994, Clause. 21.6IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995, Clause. 21.6UL 60601-1 (1st Edition):2003Revision 2006,Clause. 21.6Rough Handling-Roll Off Step Test?IS 13450 (Part 1):1994, Clause. 21.6IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995, Clause. 21.6UL 60601-1 (1st Edition):2003Revision 2006,Clause. 21.6Suspension System With Safety Devices Loading TestIS 13450 (Part 1):1994, Clause. 28.3IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995, Clause. 28.3UL 60601-1 (1st Edition):2003Revision 2006,Clause. 28.3Suspension Systems without Safety Device Loading Test?IS 13450 (Part 1):1994, Clause. 28.4IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995, Clause. 28.4UL 60601-1 (1st Edition):2003Revision 2006,Clause. 28.4Harmful Ingress of Liquids Test?IS13450 (Part 1):1994, Clause. 44.6IEC 60601-1 (2nd Ed.) 1988 AM 1:1991, AM 2:1995, Clause. 44.6UL 60601-1 (1st Ed ):2003 Revision 2006,Clause. 44.6Overflow, Spillage, Leakage, Cleaning, Disinfection, Harmful Ingress Of Liquids,?IS13450 (Part 1):1994, Clause. 44IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995, Clause. 44UL 60601-1 (1st Edition):2003 Revision 2006,Cl. 44Actuating Parts of Controls?UL 60601-1 (1st Edition):2003Revision 2006, Clause. 56.10IS 13450 (Part 1):1994, Clause. 56.10IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995, Clause. 56.10Cord Connected Foot Switch Test?UL 60601-1 (1st Edition):2003 Revision 2006, Clause. 56.11IS13450 (Part 1):1994, Cl. 56.11IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995, Clause. 56.11Cord Anchorages,?UL 60601-1 (1st Edition):2003 Revision 2006,Clause. 57.4IS 13450 (Part 1):1994, Clause. 57.4IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995, Clause. 57.4Cord Bending?UL 60601-1 (1st Edition):2003 Revision 2006,Clause. 57.4IS 13450 (Part 1):1994, Clause. 57.4IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995, Clause. 57.4Transformer Overload and Short-Circuit Tests,?UL 60601-1 (1st Edition):2003 Revision 2006,Clause. 57.9.1IS 13450 (Part 1) Clause. 57.9.1IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995, Clause. 57.9.1Transformer Dielectric Voltage Withstand?UL 60601-1 (1st Edition):2003 Revision 2006, Clause. 57.9.4IS 13450 (Part 1):1994, Clause. 57.9.4IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995, Clause. 57.9.4Interruption of Power Supply?UL 60601-1 (1st Edition):2003 Revision 2006, Clause. 56.7IS 13450 (Part 1):1994, Clause. 49IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995, Clause. 49Reversed Battery Connection by inspection?UL 60601-1 (1st Edition):2003 Revision 2006, Clause. 56.7IS13450 (Part 1):1994, Clause. 56.7IEC 60601-1 (2nd Edition):1988 AM 1:1991, AM 2:1995, Clause. 56.75.Pulse oximeter EquipmentAdditional requirements for ingress of water or (Particulate matter into ME equipment or ME system)DS/EN ISO 80601-2-61(1st Edition):2011 Clause. 201.11.6.5.101Settings and data storage following short interruptions or automatic switchoverDS/EN ISO 80601-2-61(1st Edition):2011 Clause. 201.11.8.101.2Detection of pulse oximeter probe faults and probe cable extender faultsDS/EN ISO 80601-2-61 (1st Edition):2011 Clause. 201.13.1016.Electrocardiographic Monitoring EquipmentDefibrillation protection-common mode TestIEC 60601-2-27 (3rd Edition): 2011Clause. 201.8.5.5.1Differential mode TestIEC 60601-2-27 (3rd Edition):2011, Clause. 201.8.5.5.1Ingress of water or (Particulate matter into ME Equipment and ME System)IEC 60601-2-27 (3rd Edition):2011 Clause. 201.11.6.5Interruption):of the power supply / supply mains to ME EquipmentIEC 60601-2-27 (3rd Edition):2011, Clause. 201.11.8Accuracy of signal reproductionIEC 60601-2-27 (3rd Edition): 2011, Clause. 201.12.1.101.1Input dynamic range and differential offset voltageIEC 60601-2-27 (3rd Edition): 2011,Clause. 201.12.1.101.2Input impedance?IEC 60601-2-27 (3rd Edition):2011,Clause. 201.12.1.101.3Input Noise?IEC 60601-2-27 (3rd Edition):2011,Clause. 201.12.1.101.4Multichannel crosstalk?IEC 60601-2-27 (3rd Edition):2011,Clause. 201.12.1.101.5GAIN control and stability?IEC 60601-2-27 (3rd Edition):2011,Clause. 201.12.1.101.6Sweep speed?IEC 60601-2-27 (3rd Edition):2011,Clause. 201.12.1.101.7Frequency and impulse responseIEC 60601-2-27 (3rd Edition):2011, Clause. 2 01.12.1.101.8Gain IndicatorIEC 60601-2-27 (3rd Edition):2011, Clause2 01.12.1.101.9Common mode rejectionIEC 60601-2-27 (3rd Edition):2011, Clause. 201.12.1.101.10Baseline resetIEC 60601-2-27 (3rd Edition):2011, Clause. 201.12.1.101.11Rejection of pacemaker pulsesIEC 60601-2-27 (3rd Edition):2011, Clause. 201.12.1.101.137.Electrocardiographic monitoring EquipmentSynchronizing pulse for cardio versionIEC 60601-2-27 (3rd Edition):2011, Clause. 201.12.1.101.14Heart rate range, accuracy, and QRS detection rangeIEC 60601-2-27 (3rd Edition):2011, Clause. 201.12.1.101.15Channel height and aspect ratio?IEC 60601-2-27 (3rd Edition):2011,Cl. 201.12.1.101.16?Tall T-wave rejection capability?IEC 60601-2-27 (3rd Edition):2011,Clause. 201.12.1.101.17Electrodes and Patient Cables?IEC 60601-2-27 (3rd Edition):2011,Clause. 201.15.3.4.101Time to alarm for heart rate alarm conditionsIEC 60601-2-27 (3rd Edition):2011, Clause. 208.6.6.2.103Technical alarm condition indicating inoperable ME equipmentIEC 60601-2-27 (3rd Edition):2011, Clause. 208.6.6.2.1048.Multifunction patient monitor Equipment Part Leakage CurrentIEC 60601-2-49 (2nd Edition):2011-02 Clause. 201.8.7.1.101Ingress of water or (Particulate matter into Medical Equipment and Medical SystemsIEC 60601-2-49 (2nd Edition):2011-02 Clause. 201.11.6.59.Electro-cardiograph Equipment Interruption):of the power supply / Supply Mains to Medical EquipmentIEC 60601-2-49 (2nd Edition):2011-02 Clause. 201.11.8Defibrillation protection?IEC 60601-2-25 (2nd Edition):2011Clause. 201.8.5.5.1Requirements for amplitude measurementsIEC 60601-2-25 (2nd Edition):2011 Clause. 201.12.1.101.2Requirements for absolute interval and wave duration measurementsIEC 60601-2-25 (2nd Edition):2011 Clause. 201.12.1.101.3.1Requirements for interval measurements on biological ECGIEC 60601-2-25 (2nd Edition):2011Clause. 201.12.1.101.3.2Indication of inoperable ElectrocardiographIEC 60601-2-25 (2nd Edition):2011 Clause. 201.12.4.101Goldberger and Wilson Leads?IEC 60601-2-25 (2nd Edition):2011Cl. 201.12.4.102.3.2Recovery time?IEC 60601-2-25 (2nd Edition):2011Clause. 201.12.4.102.4Input impedance?IEC 60601-2-25 (2nd Edition):2011Clause. 201.12.4.103Common Mode Rejection?IEC 60601-2-25 (2nd Edition):2011Clause. 201.12.4.105.1Overload toleranceIEC 60601-2-25 (2nd Edition):2011Clause. 201.12.4.105.2Noise Level?IEC 60601-2-25 (2nd Edition):2011Clause. 201.12.4.106.1Channel crosstalk?IEC 60601-2-25 (2nd Edition):2011Clause. 201.12.4.106.2Low frequency (impulse) responseIEC 60601-2-25 (2nd Edition):2011Cl. 201.12.4.107.1.1.2Test with calibration ECGS?IEC 60601-2-25 (2nd Edition):2011Cl. 201.12.4.107.1.2Linearity and dynamic rangeIEC 60601-2-25 (2nd Edition):2011Cl. 201.12.4.107.2?Recording speed?IEC 60601-2-25 (2nd Edition):2011Cl. 201.12.4.108.3.2Use with cardiac pacemakers?IEC 60601-2-25 (2nd Edition):2011Clause. 201.12.4.109VI.MISCELLANEOUS PRODUCTS: PHOTOVOLTAIC EQUIPMENT1.Thin-Film Terrestrial Photovoltaic (PV) Modules- Design Qualification and Type ApprovalMeasurement of nominal operating cell temperature (NOCT)IEC 61646 (2nd Edition): 2008-05. (Clause. 10.5)IS 16077 : 2013, (Clause 10.5) (Primary Method)Outdoor exposure TestIEC 61646 (2nd Edition): 2008-05. Clause. 10.8IS 16077:2013, Clause 10.82.Crystalline Silicon Terrestrial Photovoltaic (PV) Modules- Design Qualification and Type ApprovalMeasurement of nominal operating cell temperature (NOCT)IEC 61215 (2nd Edition): 2005-04 (Clause. 10.5)IS 14286:2010, (Clause 10.5) (Primary Method)Outdoor exposure TestIEC 61215 (2nd Edition): 2005-04 (Clause 10.8)IS 14286 : 2010, (Clause 10.8)VII.SAFETY TESTING FACILITY1.Automatic Data Processing Machine, Laptop/Notebook/Tablet, Printers, Plotters, Scanners, Set Top Box, Telephone Answering Machines, Visual Display Units, Videos Monitors, Wireless Keyboards, Cash Registers, Copying Machines/Duplicators, Passport Reader, Point Of Sale Terminals, Mail Processing Machines/Postage Machines/Franking Machines, Power Banks For Use In Portable Applications, Smart Card Reader, Mobile Phones, Power Adaptors, CCTV Cameras/ CCTV Recorders, USB Driven Barcode Reader, Barcode Scanners/Iris Scanners/ Optical Fingerprint Scanners, Smart Watches, Computer Systems. Plasma/LCD/LED TVs, Optical disc players, Amplifier, Musical Systems, Electronic video games, Power adapter for audio, video and similar electronic apparatusImpactEN 62368-1 Clause 4.8.4.5IEC 62368-1 (ed2:2014)Clause 4.8.4.5 Thermal cyclingEN 62368-1 Clause 5.4.1.5.3IEC 62368-1 (ed2:2014)Clause 5.4.1.5.3Determining the adequacy of a clearance using an electric strength testEN 62368-1 Clause 5.4.2.4IEC 62368-1 (ed2:2014)Clause 5.4.2.4Standard test procedure for non-separable thin sheet materialEN 62368-1 Clause 5.4.4.6.4IEC 62368-1 (ed2:2014)Clause 5.4.4.6.4Mandrel testEN 62368-1 Clause 5.4.4.6.5IEC 62368-1 (ed2:2014)Clause 5.4.4.6.5Tests for semiconductor components and for cemented jointsEN 62368-1 Clause 5.4.7IEC 62368-1 (ed2:2014)Clause 5.4.7Test method and compliance criteriaEN 62368-1 Clause 5.4.11.3IEC 62368-1 (ed2:2014)Clause 5.4.11.3Top openings and top opening propertiesEN 62368-1 Clause 6.4.8.3.3IEC 62368-1 (ed2:2014)Clause 6.4.8.3.3Test methodEN 62368-1 Clause 8.5.4.2.4IEC 62368-1 (ed2:2014)Clause 8.5.4.2.4High pressure lampsEN 62368-1 Clause 8.5..5IEC 62368-1 (ed2:2014)Clause 8.5..5Static stability testEN 62368-1 Clause 8.6.2.2IEC 62368-1 (ed2:2014)Clause 8.6.2.2Downward force testEN 62368-1 Clause 8.6.2.3IEC 62368-1 (ed2:2014)Clause 8.6.2.3Relocation stability testEN 62368-1 Clause 8.6.3IEC 62368-1 (ed2:2014)Clause 8.6.3Glass slide testEN 62368-1 Clause 8.6.4IEC 62368-1 (ed2:2014)Clause 8.6.4Wheels or casters attachment requirementEN 62368-1 Clause 8.9 (8.9.1 & 8.9.2)IEC 62368-1 (ed2:2014)Clause 8.9 (8.9.1 & 8.9.2)Mounting means for rack mounted equipmentEN 62368-1 Clause 8.11 ( 8.11.1 to 8.11.5)IEC 62368-1 (ed2:2014)Clause 8.11 ( 8.11.1 to 8.11.5)ELECTRONICS TESTINGLOCATION 3I.SAFETY TESTING FACILITY1.SAR Testing : Electrical Equipment, Electronic Instrument, Electronic Component,Electronic SubassembliesSAR – Wireless Devices used in close proximity to Head IEC 62209-1: Edition 2.0 2016-07EN 62209-1: Edition 2.0 2016-11IEC 62479?: Edition 1.0, 2010-06EN 62479?: 2010-09/EN 50360: 2017TEC/GR/SAR/001/01.MAR-09 SAR – Wireless Devices used in close proximity to Human BodyIEC 62209-2?: Edition 1.1 /AMD 1: 2019 -05IEC 62209-2: Edition 1.0 2010-03EN 62209-2: 2010-06EN 62479?: 2010-09EN 50360: 2017EN 50566: 2017-10TEC/GR/RS/SAR-002/01/JUL 17 SAR – Wireless Devices used in close proximity to HeadIEEE 1528 – 2013-06MPE (Maximum Permissible Emission)IEC 62311: Edition 1.0 2007-08 IEC 62311: Edition 2.0 2019-04 KDB-447498 DO 01:2015ELECTRONICS ESTINGMOBILE TESTING FACILITYI.MISCELLANEOUS PRODUCTS: PHOTOVOLTAIC EQUIPMENT1.Crystalline Terrestrial PV ModuleVisual ExaminationIEC 61215, 2005-04 (Cl ause 10.1 )IS 14286: 2010 (Cl ause 10.1)IEC 61215-2:2016 (Cl ause 4.1) (MQT01)Maximum Power DeterminationIEC 61215:2005-04 (Cl ause 10.2)IEC 61215-2:2016 (Cl ause 4.2) (MQT 02)IS 14286: 2010 (Cl ause 10.2)Performance Measurement at Low IrradiationIEC 61215:2005 (Cl ause 10.7)IEC 61215-2:2016 (Cl ause 4.7) (MQT 07)IS 14286: 2010 (Cl ause 10.7)Insulation TestIEC 61215 (2nd Edition):2005-04 (Clause 10.3)IS 14286: 2010 (Clasue 10.3)2.Thin Film PV Module (Cd Te, CIS, a-Si)Visual ExaminationIEC 61646:2008-05 (Clause 10.1)IS 16077: 2013 (Clause 10.1)Maximum Power DeterminationIEC 61646:2008-05 (Clause 10.2)IS 16077: 2013 (Clause 10.2)Performance Measurement at Low IrradiationIEC 61646:2008-05 (Clause 10.7)IS 16077: 2013 (Clause 10.7)Insulation TestIEC 61646:2008-05 (Clause 10.3)IS 16077: 2013 (Clause 10.3)3.PV ModuleElectroluminescence imagingLaboratory Test Method-12-LO-S0884MECHANICAL TESTINGLOCATION 1I.PLASTICS & POLYMER (PAPER & PAPER PRODUCTS)1.Plastics & PolymerFiber Reinforced Plastic ProductsTensile StrengthISO 527-4 (Type 2 and Type 3 specimens), ISO 527-5 / ASTM D 3039 Tensile E Modulus ISO 527-4, ISO 527-5 / ASTM D 3039 Compressive Strength ASTM D 3410, ASTM D 6641 Compressive Modulus ASTM D 3410, ASTM D 6641 Flexural Strength ASTM D 7264 Apparent interlaminar shear strength by short-beam method ASTM D 2344 Shear Properties of composite material by V Notch rail shear ASTM 7078 Shear Modulus of Elasticity ASTM D 7078 Density/Specific Gravity ASTM D 792/ ISO 1183-1(Method A)Performance TestingISO 11607-1, 2006 + Amd 1:2014, ISTA 2A:20112.Plastics & Polymer Packaging and Containers.Plastic films.Plastic sheets.Paper and Paper ProductsPaper.Paper BoardAtmospheric Preconditioning-Temperature and HumiditySequence 1Atmospheric Conditioning-Controlled Temperature and HumiditySequence 2 (ASTM D 4332:2014)Compression Test-Machine Apply and Hold methodSequence 3 (ASTM D 642:2015)Vibration Test-Random methodSequence 4 and 6(ASTM D 4728:2012)Drop Test-Free fall methodSequence 5(ASTM D 5276:2009)Performance TestingISO 11607-1, 2006 + Amd 1:2014, ASTM D 4169-2016Low Pressure (High Altitude) HazardSchedule I-Upto Altitude 14,000 feet (ASTM D 6653/ D 6653M:2017)Concentrated Impact-Guided free fallSchedule J-Upto 1 meter(ASTM D 6344:2017)3.Plastics and PolymersPackaging and Containers.Plastic films.Plastic sheets.Paper and Paper ProductsPaper.Paper BoardSterile Barrier and Package Systems of Medical DevicesStability TestingISO 11607-1, 2006 + Amd 1:2014 and ISO 11607-2Thermal test-Accelerated Aging testASTM F 1980:2016Integrity TestingISO 11607-1, 2006 + Amd 1:2014 Visual Inspection ASTM F 1886:2016Seal Strength ASTM F 88A:2015-Technique A and EN 868-5-Annex D)Resistance of Impermeable Materials (Air Permeance)Annex C(ISO 11607-1)Internal Pressure (Bubble Test)ASTM F 2096:2002Seal Strength(Burst Test)ASTM F 1140:2013-Test Method A and ASTM F 2054:2013-Closed PackageIntegrity-Dye Penetration ASTM F 1929:2015-Technique ADetermination of peel characteristics of paper/ plastic laminate products (Hand peel) EN 868-5-Annex E Linear Measurement of seal widthASTM F 2203RADIOLOGICAL TESTINGI.RADIATION SOURCES1.X-Ray Equipment (Three Phase Voltage: Upto 600V AC, 120A, 50/60HzSingle Phase Voltage: Upto 300V AC, 100A, 50/60Hz)Measurement of first HALF-VALUE LAYER IEC 60601-1-3 (2nd Edition): 2008 Amd.1: 2013/Clause. 7.1AIS 13450 (Part 1/ Sec 3): 2014Clause. 7.1AMeasurement of the thickness of aluminum resulting in the same first HALF-VALUE LAYER in accordance with Table 3IEC 60601-1-3 (2nd Edition): 2008 Amd. 1: 2013 Clause. 7.5IS 13450 (Part 1/ Sec 3): 2014Clause. 7.5Measurement of first HALF-VALUE LAYER under NARROW BEAM CONDITIONS with X-RAY EQUIPMENT operating at X-RAY TUBE VOLTAGES in Table 3 at Corresponding LOADING FACTORS in NORMAL USEIEC 60601-1-3 (2nd Edition): 2008 Amd. 1: 2013 Clause. 7.6IS 13450 (Part 1/ Sec 3): 2014Clause. 7.6Measurement of Focal Spot To Image Receptor Distance In Selected Configurations And Settings Of EquipmentIEC 60601-1-3 (2nd Edition): 2008 Amd. 1: 2013 Clause. 8.5.2IS 13450 (Part 1/ Sec 3): 2014Clause. 8.5.2Measurement of LEAKAGE RADIATION in the LOADING STATEIEC 60601-1-3 (2nd Edition): 2008 Amd. 1: 2013 Clause. 12.4IS 13450 (Part 1/ Sec 3): 2014Clause. 12.4Measurement of LEAKAGE RADIATION when not in the LOADING STATEIEC 60601-1-3 (2nd Edition): 2008 Amd. 1: 2013 Clause. 12.5IS 13450 (Part 1/ Sec 3): 2014Clause. 12.5STRAY RADIATION of X-RAY EQUIPMENTIEC 60601-1-3 (2nd Edition): 2008 Amd. 1: 2013 Clause. 13.6AIS 13450 (Part 1/ Sec 3): 2014Clause. 13.puted tomography Equipment(Three Phase Voltage: Upto 600V AC, 120A, 50/60HzSingle Phase Voltage: Upto 300V AC, 100A, 50/60Hz)LEAKAGE CURRENTS and PATIENT AUXILIARY CURRENTSIEC 60601-2-44 (3rd Edition): 2009 Corr. 1: 2009 Amd. 2: 2016Clause. 201.8.7IS 13450 (Part2/Sec44): 2007Test for HALF-VALUE LAYERIEC 60601-2-44 (3rd Edition): 2009 Corr. 1: 2009 Amd. 2: 2016 Clause. 203.7.6 IS 13450 (Part2/Sec44): 2007Protection against RESIDUAL RADIATIONIEC 60601-2-44 (3rd Edition): 2009 Corr. 1: 2009 Amd. 2: 2016 Clause. 203.11 IS 13450 (Part2/Sec44): 20073.X-ray equipment for interventional procedures (Three Phase Voltage: Upto 600V AC, 120A, 50/60HzSingle Phase Voltage: Upto 300V AC, 100A, 50/60Hz)Reproducibility of the RADIATION outputIEC60601-2-43 (2nd edition): 2010 + Amd.1: 2017 Clause 203.6.3.2IS 13450 (Part2/Sec 43):2008Indication of LOADING FACTORS and MODES OF OPERATIONIEC60601-2-43(2nd edition)2010 + Amd.1: 2017 Clause203.6.4.3IS 13450 (Part2/Sec 43):20084.X-ray Equipment for Radiography and Radioscopy (Three Phase Voltage: Upto 600V AC, 120A, 50/60HzSingle Phase Voltage: Upto 300V AC, 100A, 50/60Hz)LEAKAGE CURRENTS and PATIENT AUXILIARY CURRENTSIEC 60601-2-54 (1st Edition): 2009 + Amd. 1: 2015 + Amd. 2: 2018 Clause. 201.8.7IS 13450 (Part 2/Sec 54): 2016 Clause. 201.8.7Reproducibility of Radiation Output in RadiographyIEC 60601-2-54 (1st Edition): 2009 + Amd. 1: 2015 + Amd. 2: 2018 Clause. 203.6.3.2.101IS 13450 (Part 2/Sec 54): 2016Clause. 203.6.3.2.101Linearity and Constancy in RadiographyIEC 60601-2-54, (1st Edition): 2009 + Amd. 1: 2015 + Amd. 2: 2018 Clause. 203.6.3.2.102IS 13450 (Part 2/Sec 54): 2016Cl. 203.6.3.2.102Accuracy of X-RAY TUBE VOLTAGEIEC 60601-2-54, (1st Edition): 2009 + Amd. 1: 2015 + Amd. 2: 2018 Clause. 203.6.4.3.104.30IS 13450 (Part 2/Sec 54): 2016Cl. 203.6.4.3.104.30Accuracy of X-RAY TUBE CURRENTIEC 60601-2-54 (1st Edition): 2009 + Amd. 1: 2015 + Amd. 2: 2018 Clause. 203.6.4.3.104.4 IS 13450 (Part 2/Sec54): 2016Clause. 203.6.4.3.104.4Accuracy of LOADING TIMEIEC 60601-2-54 (1st Edition): 2009 + Amd. 1: 2015 + Amd. 2: 2018 Clause. 203.6.4.3.104.5IS 13450 (Part 2/Sec 54): 2016Clause. 203.6.4.3.104.5Accuracy of CURRENT TIME PRODUCTIEC 60601-2-54, (1st Edition): 2009 + Amd. 1: 2015 + Amd. 2: 2018 Clause. 203.6.4.3.104.6IS 13450 (Part 2/Sec 54): 2016Clause. 203.6.4.3.104.6Dosimetric IndicationIEC 60601-2-54, (1st Edition): 2009 + Amd. 1: 2015 + Amd. 2: 2018 Clause. 203.6.4.5 IS 13450 (Part 2/Sec 54): 2016Clause. 203.6.4.55.Dental intra-oral X-ray Equipment(Three Phase Voltage: Upto 600V AC, 120A, 50/60HzSingle Phase Voltage: Upto 300V AC, 100A, 50/60Hz)LEAKAGE CURRENTS and PATIENT AUXILIARY CURRENTSIEC 60601-2-65, (1st Edition): 2012 + Amd. 1: 2017 Clause. 201.8.7IS 13450 (Part 2/Sec 65): 2016Clause. 201.8.7Protection against excessive temperatures of X-RAY MONOBLOCK ASSEMBLIESIEC 60601-2-65, (1st Edition): 2012 + Amd. 1: 2017 Clause. 201.11.101IS 13450 (Part 2/Sec 65): 2016Clause. 201.11.101Adjustment of RADIATION dose and RADIATION qualityIEC 60601-2-65, (1st Edition): 2012 + Amd. 1: 2017 Clause. 203.6.3.1IS 13450 (Part 2/Sec 65): 2016Clause. 203.6.3.1Linearity of AIR KERMAIEC 60601-2-65, (1st Edition): 2012 + Amd. 1: 2017 Clause. 203.6.3.1.101IS 13450 (Part 2/Sec 65): 2016Clause. 203.6.3.1.101Coefficient of variation of the AIR KERMAIEC 60601-2-65, (1st Edition): 2012 + Amd. 1: 2017 Clause. 203.6.3.2.101IS 13450 (Part 2/Sec 65): 2016Clause. 203.6.3.2.101Accuracy of X-RAY TUBE VOLTAGEIEC 60601-2-65, (1st Edition): 2012 + Amd. 1: 2017 Cl. 203.6.4.3.102.2IS 13450 (Part 2/Sec 65): 2016Cl. 203.6.4.3.102.2Accuracy of X-RAY TUBE CURRENTIEC 60601-2-65, (1st Edition): 2012 + Amd. 1: 2017 Clause. 203.6.4.3.102.3IS 13450 (Part 2/Sec 65): 2016Cl. 203.6.4.3.102.3Accuracy of IRRADIATION TIMEIEC 60601-2-65, (1st Edition): 2012 + Amd. 1: 2017 Cl. 203.6.4.3.102.4IS 13450 (Part 2/Sec 65): 2016Cl. 203.6.4.3.102.4HALF-VALUE LAYERS and TOTAL FILTRATION in X-RAY EQUIPMENTIEC 60601-2-65(1st Edition): 2012 + Amd. 1: 2017 Clause. 203.7.1IS 13450 (Part 2/Sec 65): 2016Clause. 203.7.1LEAKAGE RADIATION in the LOADING STATEIEC 60601-2-65, (1st Edition): 2012 + Amd. 1: 2017Clause. 203.12.4IS 13450 (Part 2/Sec 65): 2016Clause. 203.12.4Positioning of the PATIENT and restriction of the irradiated areaIEC 60601-2-65, (1st Edition): 2012 Clause. 203.8.5.4IS 13450 (Part 2/Sec 65): 2016Clause. 203.8.5.46.X-ray tube assemblies for medical diagnosis(Three Phase Voltage: Upto 600V AC, 120A, 50/60HzSingle Phase Voltage: Upto 300V AC, 100A, 50/60Hz)Maximum temperature during NORMAL USEIEC 60601-2-28 (3rd Edition): 2017Clause. 201.11.1.17.Dental extra-oral X-ray Equipment(Three Phase Voltage: Upto 600V AC, 120A, 50/60HzSingle Phase Voltage: Upto 300V AC, 100A, 50/60Hz)Adjustment of RADIATION dose and RADIATION qualityIEC 60601-2-63, (1st Edition): 2012 + Amd. 1: 2017 Clause. 203.6.3.1IS 13450 (Part 2/Sec 63): 2016Clause. 203.6.3.1Linearity of AIR KERMAIEC 60601-2-63, (1st Edition): 2012 + Amd. 1: 2017 Clause. 203.6.3.1.101IS 13450 (Part 2/Sec 63): 2016Clause. 203.6.3.1.101Coefficient of variation of the AIR KERMAIEC 60601-2-63, (1st Edition): 2012 + Amd. 1: 2017 Clause. 203.6.3.2.101IS 13450 (Part 2/Sec 63): 2016Clause. 203.6.3.2.101Accuracy of X-RAY TUBE VOLTAGEIEC 60601-2-63, (1st Edition): 2012 + Amd. 1: 2017 Cl. 203.6.4.3.102.2IS 13450 (Part 2/Sec 63): 2016Cl. 203.6.4.3.102.2Accuracy of X-RAY TUBE CURRENTIEC 60601-2-63, (1st Edition): 2012 + Amd. 1: 2017 Clause. 203.6.4.3.102.3IS 13450 (Part 2/Sec 63): 2016Cl. 203.6.4.3.102.3Accuracy of IRRADIATION TIMEIEC 60601-2-63, (1st Edition): 2012 + Amd. 1: 2017 Cl. 203.6.4.3.102.4IS 13450 (Part 2/Sec 63): 2016 ................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download