This document gives a historic list of the major changes in The Flexidome XF and the Unity Dome (VG4 100 series) camera firmware.

Release 1.17: FW1.21/ EEP1.04 / Bootloader 1.20 (Released 15-07-2009)

o Resolved customer complaints: update in progress

▪ Improved robustness when external noise is present on the coax

o new Bootloader 1.20

▪ Timeout feature implemented

Release 1.12: FW1.16/ EEP1.04 / Bootloader 1.18 (Released 28-08-2007)

o DC Iris optimization: Improved startup calibration

Release 1.09: FW1.13/ EEP1.03 / Bootloader 1.18 (Released 23-02-2007)

o BLC algorithm from Dinion XF imported

Release 1.08: FW1.12/ EEP1.02 / Bootloader 1.18 (Released 21-02-2007)

o Solved bug in Day/Night menu: IR Contrast item

o French OSD version also available (subdirectory \French)

Release 1.06: FW1.10/ EEP1.02 / Bootloader 1.18 (Released 14-12-2006)

o Improvement of internal communications

o Improved the bootloader

Release 1.05: FW1.09/ EEP1.02 / Bootloader 1.17 (Released 28-11-2006)

o Added camera colour in Bicom interface

o Updated internal communications driver

Release 1.04: FW1.06/ EEP1.02 / Bootloader 1.16 (Released 15-09-2006)

o Improved lens initialization under low light circumstances

o Unity Dome (VG4 100 series) default values changed

o New bootloader 1.16, changed because of FlexiDome IP camera.

Release 1.03: FW1.03/ EEP1.01 / Bootloader 1.15 (Released 11-04-2006)

o Corrected VMD Mode selection when using the LEFT KEY via keyboard

Release 1.02: FW1.02/ EEP1.00 / Bootloader 1.15 (Released 15-03-2006)

o Corrected communication problem in reading EEPROM value

o Improved Bootloader

Release 1.00: FW1.00/ EEP1.00 / Bootloader 1.14 (Released 03-02-2006)

o First release

Firmware Update Procedure

Note: You must use version 3.01 or higher of the Configuration Tool for Imaging Devices (CTFID).

1. Create a Bilinx connection between a PC and the VG4 100 Series AutoDome:

a. Plug the USB end of the VP-USB into a USB port on the PC (the Windows Operating System configures the PC to recognize the VP-USB).

b. Connect the female BNC end of the VP-USB to a male BNC connector that transmits data.

2. Ensure that the VG4 100 Series AutoDome firmware update file is saved to the computer.

3. Double-click the CTFID icon on the Windows Desktop. The CTFID software automatically checks for the Bilinx signal from the VG4 AutoDome.

4. On the Device Information screen take note of the Device Model number and the Video Type.

5. Click the Upload Firmware button on the right side of the CTFID Main Screen.

6. Navigate to the location of the firmware update file.

7. Select the appropriate file for your Device Model and Video Type; then click OK.

The CTFID displays a message warning you that the firware update process erases all device settings and returns the settings to the factory default value.

8. Click OK to confirm the warning and to start the update process.

The CTFID begins the firmware update and marks the update progress at the bottom of the screen. The update process may take several minutes to complete.

9. Once the firmware update is complete, the CTFID displays message that the firmware update was successful.

10. Click OK to accept the message.

11. The CTFID reloads the settings from the camera and displays the Device Information screen.

12. Ensure that the Firmware Version is 1.21 and that a monitor displays video from the VG4 100 Series AutoDome.

-----------------------