Model 267/267MR DIFFERENTIAL PRESSURE - Transcat
DIFFERENTIAL PRESSURE
Model 267/267MR
Very Low Differential Pressure Transducer
Model 267MR - Multi-Range
Model 267 w/ Display Option
NOTE: Setra quality standards are based on ANSI-Z540-1. The calibration of this product is NIST traceable. U.S. Patent nos. 6019002; 6014800
DESCRIPTION
Setra's Model 267 and 267MR pressure transducers sense gauge (static) or differential pressure in air pressure ranges as low as 0.1"WC Full Scale up to 100"WC.
FEATURES
Model 267MR Offers Multi-Range Capability, 6 Field Selectable Ranges via Dip Switches, and Field Selectable 0-5 or 0-10 VDC Output
Model 267 Offers an Optional 3 1/2 Digit LCD Display with a 0.5% FS Standard Accuracy
NEMA 4/IP65 Rated Housing
Optional Accuracies as High as 0.25% FS
24 VAC or 24 VDC Excitation
PG-9, PG13.5 or Conduit Electrical Termination Integral Static Pressure Probe
Ranges as low as 0.1 in. W.C. (25 Pa) Meets CE Conformance Standards
The Model 267 gauge pressure transducer is offered in a high level voltage or 4 to 20 mA output and is available with a static pressure probe for installation directly onto the duct. The 0.25" diameter pressure probe is made of sturdy extruded aluminum and is designed with baffles to prevent velocity pressure errors. This unit is also available with an LCD display.
The 267MR multi-range transducer offers 6 field selectable pressure ranges (bidirectional and unidirectional), and field configurable outputs of 0 to 5 VDC, 0 to 10 VDC, and 4 to 20 mA. With the flip of a switch the user can field calibrate the unit and be assured of optimum performance.
APPLICATIONS
Heating, Ventilating and Air Conditioning (HVAC)
Energy Management Systems Static Duct Pressure
Clean Room Pressure
Oven Pressurization and Furnace Draft Controls
DIMENSIONS
1.73
0.80 1.18
44
20
30
0.93 24
7/8" 22
PG and Conduit Opening Electrical Termination
1.74
6.20
44
158
5.60
142
2.68 68
1.34 34
2.36 60 1.29 33
0.18 4.5 0.78 20 0.50 13
1.18 30 0.80 20
9 pin D-sub Connector Electrical Termination
5.60 142
8.00 2.03
9.45 240 1.29 33
Static Duct Probe
LCD available as an Option
3/16" O.D. PRESSURE FITTING FOR
0.6
on Model 267 only.
1/4" PUSH-ON TUBING
15
1/4" NPT Brass Fitting
Phone: 800-257-3872 ? Fax: 978-264-0292 ? ?2014 Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc.
DIFFERENTIAL PRESSURE
Model 267/267MR
Very Low Differential Pressure Transducer
SPECIFICATIONS
Performance Data
Environmental Data
Electrical Data (Voltage)
Standard
Optional
Operating7 Temperature ?F (?C) 0 to +150 (-18 to +65)
Circuit
3-Wire (Exc, Gnd, Sig), Protected from Miswiring
Accuracy RSS1 (at constant temp)
?1.0% FS ?0.4% FS ?0.25% FS Storage Temperature ?F (?C) -65 to +180 (-54 to +82)
Excitation (for 0-5 VDC Output)
9 to 30 VAC /12 to 40 VDC
Non-Linearity, BFSL
?0.98% FS ?0.38% FS ?0.22% FS Physical Description
Excitation (for 0-10 VDC Output)
11 to 30 VAC /13 to 40 VDC
Hysteresis
?0.10% FS ?0.10% FS ?0.10% FS Case
IP65/NEMA 4 Plastic Glass-Filled Polycarbonate UL94V-O Case
Model 267
Non-Repeatability
?0.5% FS ?0.5% FS ?0.5% FS Electrical Connection
Screw Terminal Strip Inside of Case
Output3
0 to 5 VDC4 / 0 to 10 VDC4
Position Effect
Electirical Terminations
PG-9/PG13.5 Strain Relief, 1/2" Conduit Model 267MR Opening, or 9 Pin D-Sub Connector*
Range
Zero Offset (%FS/G)
*9 Pin D-Sub Connector is not suitable for NEMA4/IP-65 Environments
Output (Field Selectable)
0 to 10 VDC4
0.1 in. WC 2.3
Zero and Span Adjustments Accessible Inside of Case
Bidirectional Output at Zero
Mid-Range of Specified
0.25 in. WC 1 Unit if factory calibrated at 0g effect in the vertical position 0.5 in. WC 0.5
1.0 in. WC 0.3 2.5 in. WC 0.2
Display (Optional on 267 only) Accessible Inside of Case Display (1/74"W x 0.78"H)
Pressure Fittings
3/16" O.D. Barbed Brass for 1/4" Push-On Tubing (Standard) Static Pressure Probe (Optional 1/4" NPTF Brass (Optional)
Output Impedance
Ohms
Re-Ranging (267MR Only)
5 Position Dip Switches (Located Inside Case)
Electrical Data (Current)
Circuit
2-Wire, Protected from Miswiring
10 in. WC 0.15
Pressure Media
Typically air or similar non-conducting gases.
Mounting
2 Mounting Tabs with 0.18" Holes Pressure Probe Assembly is Supplied with a 6061 Aluminum Alloy Probe and a Gasket Against the Duct 7.8" to Seal
Output5 Bidirectional Output at Zero Min. Loop Supply Voltage (VDC)
4 to 20 mA6 12 mA 9 + 0.02 x (Resistance of Receiver plus line)
Weight (approx.)
9.0 Ounces (255 grams) 9.5 Ounces (Duct Probe Assembly)
Max. Loop Supply Voltage (VDC)
30 + 0.004 x (Resistance of Receiver plus line)
Thermal Effects2,3
Re-Ranging (267MR only)
4 Position Dip Switches (located inside case)
Compensated Range ?F (?C) Zero/Span Shift %FS/?F (?C) Maximum Line Pressure Overpressure
+40 to +150 (+5 to +65) ?0.033 (?0.06) 10 psi Up to 10 psi (Range Dependant)
Long Term Stability
0.1% FS Total
1 RSS of Non-Linearity, Hysteresis, and Non-Repeatability. 2 Units calibrated at nominal 70?F. Maximum thermal error computed from this datum. 3 Calibrated into a 50K ohm load, operable into a 5000 ohm load or greater. 4Zero output factory set to within ?50mV (?25 mV for optional accuracies). Span (Full Scale) output factory set to within ?50mV (?25 mV for optional accuracies 5 Calibrated at factory with a 24 VDC loop supply voltage and a 250 ohm load. 6Zero output factory set to within ?0.16 mA (?0.08 mA for optional accuracies). Span (Full Scale) output factoy set to within ?0.16 mA (?0.08mA for optional Accuracies.) 7 Operating temperature limits of the electronics only. Pressure media temperatures may be considerably higher.
WIRING
Power Supply
Readout or DAS
+EXC
GND +SIG
Model 267 / 267MR
Voltage Output
9 to 30 VDC
+ Models
_ 267 / 267MR
Current Monitor Device
Current Output
?2014 Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc. Phone: 800-257-3872 ? Fax: 978-264-0292 ?
DIFFERENTIAL PRESSURE
Model 267/267MR
Very Low Differential Pressure Transducer
D-SUB ELECTRICAL TERMINATION
PIN 1 + Output
PIN 4 + EXC
CONNECTION
+ Excitation
+ Output
PINS 8, 9* Common
Common
Excitation 9 to 30 VAC/ 11.5 to
42 VDC 12 to 30 VAC/ 13 to
42 VDC
Voltage Output
9 PIN D-SUB CONNECTOR
4
1
8, 9
Output 0 to 5 VDC 0 to 10 VDC
PIN 4 + EXC
PIN 9 - EXC
CONNECTION
+ Excitation
- Excitation
9 PIN D-SUB CONNECTOR
4 9
Current Output
ORDERING INFORMATION (Model 267)
2671
Model
Range Code
2671 = 267 See Table 1 Below
Output 11 4-20 mA 2D 0-5 VDC 2E 0-10 VDC
Pressure Fitting/Elec. Termination Accuracy (Full Scale) Display
3/16" Barbed Brass Fitting
Std. C ?1%3 D LCD4
Std. G1 PG-13.5 Strain Relief Opt.1 E ?0.4% N None
Std. G2 PG9 Strain Relief
Opt. 1 F ?0.25%
Std. D9 9 pin D-Sub Conn. Opt. 1 G ?1%
Std. A1 1/2" Conduit Opening Opt.1,2 H ?0.5%
1/4"NPTF Brass Fitting
1. Optional accuracies include Calibration Certificate
Opt. 1K PG-9 Strain Relief Opt. 2K PG-13.5 Strain Relief Opt. 9K 9 Pin D-Sub Conn. Opt. AK 1/2" Conduit Opening Static Duct Probe Opt. 1P PG-9 Strain Relief
2. ?0.5% FS (Code H) accuracy is standard when ordered with the LCD Display (Code D).
3. Not available with LCD Display (Code D)
4. ?0.5% FS (Code H) Accuracy is standard when ordered with LCD Display (Code D)
Opt. 2P PG-13.5 Strain Relief
Opt. 9P 9 Pin D-Sub Conn..
Opt. Ap 1/2" Conduit Opening
Table 1. Range Specification
RANGE CODE
UNIDIRECTIONAL "W.C.
RANGE CODE
BIDIRECTIONAL "W.C.
RANGE CODE
UNIDIRECTIONAL PASCALS
RANGE CODE
BIDIRECTIONAL PASCALS
0R1WD R25WD 0R5WD 001WD 1RSWD 2R5WD 005WD 010WD 025WD 050WD 100WD
0 to 0.1 0 to 0.25 0 to 0.5
0 to 1 0 to 1.5 0 to 2.5 0 to 5 0 to 10 0 to 25 0 to 50 0 to 100
0R1WB R25WB 0R5WB 001WB 1RSWB 2R5WB 005WB 010WB 025WB 050WB 100WB
?0.1 ?0.25 ?0.5
?1 ?1.5 ?2.5 ?5 ?10 ?25 ?50
025LD 050LD 100LD 250LD 500LD 10CLD 25CLD 40CLD 70CLD
0 to 25 0 to 50 0 to 100 0 to 250 0 to 500 0 to 1000 0 to 2500 0 to 4000 0 to 7000
025LB 050LB 100LB 250LB 500LB 10CLB 25CLB 40CLB 70CLB
?25 ?50 ?100 ?250 ?500 ?1000 ?2500
Ordering Example: Part No. 2671R25WD11G2CD for a 0 to .25 in. WC Unidirectional Range, 4-20 mA Output, 3/16" Barbed Brass Fitting, PG-9 Electrical Termination, 1% Accuracy with LCD Display
Phone: 800-257-3872 ? Fax: 978-264-0292 ? ?2014 Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc.
DIFFERENTIAL PRESSURE
ORDERING INFORMATION (Model 267MR)
Model 267/267MR
Very Low Differential Pressure Transducer
2671
Model
Range Code
2671 = 267 See Table 1 Below
Output 11 4-20 mA 2D 0-5 VDC 2E 0-10 VDC
Pressure Fitting/Elec. Termination Accuracy (Full Scale) Display
3/16" Barbed Brass Fitting
Std. C ?1% N None
Std. G1 PG-13.5 Strain Relief Opt.1 G ?1%
Std. G2 PG9 Strain Relief Std. D9 9 pin D-Sub Conn.
1. Order Opt G for ?1% Acc. to include Calibration Certificate
Std. A1 1/2" Conduit Opening Note: Opional higher accuracies are
1/4"NPTF Brass Fitting
not avaialble on the 267MR.
Opt. 1K PG-9 Strain Relief Opt. 2K PG-13.5 Strain Relief
Ranges are factory set for the highest range
Opt. 9K 9 Pin D-Sub Conn.
Opt. AK 1/2" Conduit Opening
Static Duct Probe
Opt. 1P PG-9 Strain Relief
Opt. 2P PG-13.5 Strain Relief
Opt. 9P 9 Pin D-Sub Conn..
Opt. Ap 1/2" Conduit Opening
Table 1. Range Specification
RANGE CODE
DIFFERENTIAL "W.C.
MR1WD
0 to 0.1 ?0.05
MR2WD
0 to 0.25 0 to 0.5 0 to 1
?0.125 ?0.25 ?0.5
RANGE CODE
MR5LD MR6LD
DIFFERENTIAL PASCALS
0 to 25
?12.5
0 to 50 0 to 100 0 to 200
?25 ?50 ?100
MR3WD MR4WD
0 to 1.25 0 to 2.5 0 to 5.0
?0.625 ?1.25 ?2.5
0 to 7.5 0 to 15 0 to 30
?3.75 ?7.5 ?15
MR7LD MR8LD MR9LD
0 to 250 0 to 500 0 to 1000
0 to 625 0 to 1250 0 to 2500
0 to 1875 0 to 3750 0 to 7000
?125 ?250 ?500
?312 ?625 ?1250
?937 ?1875 ?3750
Ordering Example: Part No. 2671MR1WD11G1CN = 267MR Transducer, 0.01, ?0.05 in. WC, Differential, 4-20 mA Output, 3/16" Barbed Brass Fitting, PG-13.5 Strain Relief Electrical Termination, 1% Accuracy with No Display
SSP267/267MR Rev.J11/8/12
?2014 Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc. Phone: 800-257-3872 ? Fax: 978-264-0292 ?
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related searches
- elevated crp differential diagnosis
- differential diagnosis of myocardial infarction
- myocardial infarction differential diagnosis
- elevated esr crp differential diagnosis
- esr over 100 differential diagnosis
- hypertrophic cardiomyopathy differential diagnosis
- mi differential diagnosis
- heart attack differential diagnosis
- differential diagnosis of acute cough
- differential diagnosis for chronic cough
- differential diagnosis for acute cough
- differential diagnosis of cough