STREETLIGHT PHOTOMETRIC TEST REPORT
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT
Page 1 Of 10
STREETLIGHT PHOTOMETRIC TEST REPORT
Test:U:119.91V I:0.1784A P:21.245W PF:0.9933 Freq:49.99Hz
NAME: BLSB-40K22W-742
TYPE:
Lamp Flux:2686.15x1 lm WEIGHT: 2.5kg
SPEC.:
DIM.:
SERIAL No.: 001
MFR.: EVERFINE
SUR.: 0.295*1.195
Shielding Angle:
DATA OF LAMP
MODEL
Imax(cd)
NOMINAL POWER(W)
LOR(%)
RATED VOLTAGE(V)
TOTAL FLUX(lm)
NOMINAL FLUX(lm) 2686.15 MAXIMUM @(C, )
LAMPS INSIDE
1
up(%)
TEST VOLTAGE(V)
220
down(%)
PHOTOMETRIC DATA Eff: 126.44 lm/W
589.4
street_up(%)
5.2
100.0
street_down(%) 44.6
2686
house_up(%)
5.3
90,54.0 house_down(%)
44.9
10.5
76 FLASHAREA(m2) 0.05000
89.5
SLI
20.656
INTENSITY DISTRIBUTION DIAGRAM IN C PLANS
-/+180
-150
150
-120
120
MAX INTENSITY CONE SURFACE DISTRIBUTION DIAGRAM
C210
C180
C150
C240
C120
-90
0
90
C270
120
240
-60
360
60
-30
480 600
UNIT:cd
C0/180,360.0
C90/270,360.0 30
0 AVERAGE BEAM ANGLE(50%):360.0 DEG
C300
C330 HOUSE SIDE
0
C90
120
240
360
C60
480
600
C30
C0 Max @ = 54.0DEG STREET SIDE
C Range: 0 - 360DEG C Interval: 22.5DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2020-10-22
Range: 0 - 180DEG Interval: 1.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.429 Humidity:65.0% Test Distance:8.270m [K=1.0000] Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT
Page 2 Of 10
STREETLIGHT ISOCANDELA DIAGRAM
270 285 300 315 330 345 HOUSE SIDE
180 170 160 150 140 130
120
110
100
C0
15
30 45 60 75 90
90
80
70
60
50
40
30
20
10
STREET SIDE
Classification:
IES:Type V - Very Short CIE:Broad - Short IES:None cut-off CIE:Non-cut-off Max.At80:118.7cd/klm Max.At90:52.78cd/klm Max.80-90:118.7cd/klm NRB 5101:Semi limited[14.7%]
ISOCANDELA DIAGRAM
UNIT
cd
Imax=100%
589
90%
530
80%
471
70%
413
60%
354
50%
295
40%
236
30%
177
20%
118
10%
59
5%
29
C Range: 0 - 360DEG C Interval: 22.5DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2020-10-22
Range: 0 - 180DEG Interval: 1.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.429 Humidity:65.0% Test Distance:8.270m [K=1.0000] Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT
Page 3 Of 10
COEFFICIENT OF UTILIZATION CURVE AND ISOLUX DIAGRAM
CU(%) 100 90 80 70 60 50 40 30 20 10
0 2
TILT ANGLE 0.0(DEG) 5.0(DEG)
10.0(DEG) 15.0(DEG) 20.0(DEG)
STREETLIGHT COEFFICIENT OF UTILIZATION CURVE
1
0
1
HOUSE SIDE
STREET SIDE
2
3
4
RATIO OF DISTANCE TO MOUNTING HEIGHT
STREET SIDE D/MH HOUSE SIDE
ROAD SURFACE ISOLUX DIAGRAM
ILLUMINANCE AT MH=10 m,Enadir = 0.02 lx
TO CONVERT TO OTHER MH,MULTIPLY BY FACTOR IN THE TABLE. 1
According to LB/T001-2008: U = Emin/Eavg = 0.073 Eavg = 3.195 lx
HEIGHT
FACTOR
5 m
4.000
0
6 m
2.778
1
7 m
2.041
8 m
1.563
2
9 m
1.235
10 m
1.000
3
11 m
0.826
4-7 -6 -5 -4 -3 -2 -1 0
1
2
3
4
RATIO OF DISTANCE TO MOUNTING HEIGHT
2.4
1.8
1.5
1.2
0.3
0.15
0.089
0.03
567
0.89 0.015
12 m 13 m 14 m 15 m 16 m
0.694 0.592 0.510 0.444 0.391
C Range: 0 - 360DEG C Interval: 22.5DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2020-10-22
Range: 0 - 180DEG Interval: 1.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.429 Humidity:65.0% Test Distance:8.270m [K=1.0000] Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT
Page 4 Of 10
ZONAL FLUX DIAGRAM
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 DEG
C0 9.179 229.5 379.0 510.8 565.4 524.8 410.0 222.3 111.1 78.74 57.05 40.90 27.83 17.15 11.49 7.939 5.473 3.421
C45 8.492 208.2 458.0 547.7 570.0 526.0 396.9 196.2 73.24 52.14 40.94 33.49 27.15 20.13 12.95 9.047 5.506 3.613
C90 6.695 184.7 385.3 490.8 584.2 557.1 463.5 268.5 121.9 82.84 58.15 41.24 28.63 18.63 13.84 8.790 6.096 3.554
C135
C180
C225
5.366 4.492 5.391
80.82 135.8 45.80
407.7 327.8 420.1
530.2 443.4 521.7
578.8 555.2 572.7
559.0 556.2 554.9
452.3 483.3 456.7
273.0 316.3 282.0
89.11 141.8 95.32
56.72 90.20 57.74
43.06 64.67 44.02
34.99 46.66 35.77
28.80 32.47 28.94
22.27 20.72 21.79
15.00 14.63 14.79
10.29 9.260 10.64
6.343 5.823 6.457
3.634 3.442 3.624
LUMINOUS INTENSITY:cd
C270 6.979 170.9 376.3 483.2 584.4 556.5 476.2 283.0 125.9 83.44 58.23 41.07 28.38 17.98 13.28 9.606 6.169 3.559
C315
zone total %lum,lamp
8.531
0- 10 0.4283 0.4283 0.02,0.02
186.2 10- 20 20.30 20.73 0.77,0.77
443.8 20- 30 127.8 148.5 5.53,5.53
536.1 30- 40 268.4 416.9 15.5,15.5
564.0 40- 50 408.5 825.4 30.7,30.7
533.6 50- 60 504.3 1330 49.5,49.5
405.0 60- 70 500.3 1830 68.1,68.1
209.6 70- 80 382.0 2212 82.3,82.3
74.33 80- 90 192.3 2404 89.5,89.5
52.80 90-100 98.46 2503 93.2,93.2
41.28 100-110 67.38 2570 95.7,95.7
33.76 110-120 46.87 2617 97.4,97.4
26.98 120-130 31.28 2648 98.6,98.6
19.69 130-140 19.14 2667 99.3,99.3
13.22 140-150 10.66 2678 99.7,99.7
9.902 150-160 5.319 2683 99.9,99.9
5.688 160-170 2.251 2686 100,100
3.634 170-180 0.4596 2686 100,100
UNIT:lm
C Range: 0 - 360DEG C Interval: 22.5DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2020-10-22
Range: 0 - 180DEG Interval: 1.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.429 Humidity:65.0% Test Distance:8.270m [K=1.0000] Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT
Page 5 Of 10
ISOCANDELA DIAGRAM
VERTICAL(DEG)
90
10% 60.52
20% 121.0
80
30% 181.6
40% 242.1
70
50% 302.6
60% 363.1
70% 423.6
60
80% 484.1
90% 544.7
50
40
30
20
10
0 MAX = 595.96
MIN = 1.8074
-10
AVG = 318.90
AVG/MAX = 0.54
-20
MIN/MAX = 0.00
-30
-40
-50
-60
-70 Imax:605.2(H-54.0,V0.0)
-80
(At:C=90.0,Gamma=54.0)
UNIT: cd -90
-90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90
HORIZONTAL(DEG)
C Range: 0 - 360DEG C Interval: 22.5DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2020-10-22
Range: 0 - 180DEG Interval: 1.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V2.00.429 Humidity:65.0% Test Distance:8.270m [K=1.0000] Remarks:
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- dallas texas al 742 faa rnav gps rwy 35
- viscosity and thermal conductivity equations for nitrogen
- coe ce 21 22
- section 1 summary of selected reportable diseases conditions
- inch and metric thread size comparison chart pouce et métrique
- release notes for cisco ncs 560 series routers cisco ios
- airport diagram
- hh fr r trfrr pulse eng
- 1 calculus of variations 2 history weebly
- streetlight photometric test report
Related searches
- south dakota school report card
- state of tn report card
- state school report card
- student report cards samples
- kentucky school report cards
- wisconsin school district report cards
- wisconsin state school report cards
- pdf name this english test complete the test good luck
- test statistic for hypothesis test calculator
- test validity and test reliability
- test strategy vs test plan
- test plan vs test cases