SUMMARY REPORT



DECEMBER 2008

Elevator QEI / Turnover & Performance Report

TEAM PASSENGER ELEVATOR 1

TARGET T-2410

OAHU HONOLULU WEST

4380 LAWEHANA STREET

HONOLULU, HI

By: ELEVATOR CONSULTING SERVICES, INC.

Equipment Inventory

Control Type: SELECTIVE COLLECTIVE

MCE HMC-1000

Contract Speed: 125 FPM

Machine Type: MEI HYDRAULIC PUMP UNIT

MCE HMC-1000 CONTROLLER

Door Equipment: GAL SINGLE SLIDE

Door Size/Type: 42” WIDE X 84” HIGH

Number of Openings: TWO (2) IN LINE

Typical Floor Height: 16’ 4”

Floors Served: *1, 2

City/State Number: #1 - PENDING

HI

Capacity: 2500 LBS

Emergency Light: OK

Alarm Bell: OK

Maintenance Log: NONE

ITEMS IN RED ARE THE RESPONSIBILITY OF THE ELEVATOR CONTRACTOR

ITEMS IN BLUE ARE THE RESPONSIBILITY OF THE BUILDING OWNER

PERFORMANCE

Speed Up: 125 FPM

Speed Down: 125 FPM

Perform Up: 20.9 SEC

Perform Down: 25.2 SEC

DRAWN OUT

Door Open: 3.5 SEC

Door Close: 4.9 SEC

Hall Call Dwell: 4.5 SEC

Car Call Dwell: 6.5 SEC – 1ST FLOOR

2.3 SEC – 2ND FLOOR

Nudging: 40 SEC

Door Torque: 5 LBS

Ride Quality

Ride: OK

Deceleration Up: OK

Deceleration Down: NI

Acceleration Up: OK

Acceleration Down: OK

Stop: OK

Leveling: NI

1ST FLOOR

Equipment Room

Access: OK

Headroom: OK

Enclosure: OK

Lighting: OK

Cleanliness: OK

Air Circulation,Ventilation: OK

TOO COLD

Pipes, Ducts, Non Elev: NONE

Parts: NONE

GFIC Receptacles: YES

Fire Extinguisher: OK

NEW 11-08

Guarding: OK

Self Closing, Locking door: OK

Numbering of units: OK

Sprinkler in room: NO

REMOVED?

Lockable, Fused Disconnect: OK

110 Volt Disconnect: YES

Shunt trip protection: YES

MSDS documentation: NO

Oil monitoring sheet: NO

Signage on door: NI

TEMP ONLY

Control Panel

Type of Control: MICROPROCESSOR

HMC-1000

Manufacturer: MCE

Install Date: 11-08

Installation Code: ASME 17.1 1996

Data Tag: CONTROLLER DOOR

Cleanliness: OK

Identification: OK

MCE JOB # 2008064181

SERIAL # 3251523

MEI JOB # NHP1215X

DATED

Software Version: 06-03-0003-1

DATED 8-1-08

Guarding: OK

U. L. Label: CSA

Battery Rescuvator

Existing: YES

Model: RB-2

Mfg: R & R

Batteries: OK

Wiring: OK

Status: OK

Components-Controller

Relays: OK

Enclosure / Open Style: ENCLOSED

Contacts: OK

Resistors: OK

P.C. Boards / Timers: OK

Wiring: OK

Performance: OK

Camera Wire: OK

Telephone: OK

Programmed Site: ALERT ONE

Starters

Type: ELECTRONIC

Size: AC53a 6-6 30-80

Mfg: SIEMENS

Contacts: OK

Wiring: OK

Mounting: OK

Starts: 1310 / 12-9-08

Pump Unit

Model: ESS-88

Mfg: MEI

Cleanliness: OK

Leaks: NONE

Noise: OK

Oil level: OK

Oil: OK

HYDRO SAFE VEG. OIL

Belts: N/A

Sheaves: N/A

Pump: OK

IMO

A4PIC-187P

Subs / Dry: SUBS

Shut Off: OK

Valves: OK

MAXTON

UC-4ME1

Muffler: WILKES MCLEAN

75 LBS

Seals: NI

Covers: OK

Acceptance Test: OK

Tagged: MISSING

Annual No Load Test: N/A

Tagged: N/A

Oil Coolers

Exists: YES

Mfg: MEI

AOC-24-96514

Hoses: OK

Wiring: OK

Leaks: NONE

Air Filter: OK

Oil Filter: OK

Motor HP: .25 HP

Motor AMPS: 3.6 / 1.81 / 2.28 / 1.14

Motor RPM: 1400 / 1700

Motor Mfg: BALDOR

Motor

Isolation: OK

Grounded: OK

Bearings: OK

Covers: OK

Frame: L217Z

HP: 20

IMPERIAL

RPM: 3395

AMPS: 56.2/28.1

Starts/Hr: 80

Hoistway

Selector Car Top Device

Cleanliness: OK

Sensors: OK

Magnets: OK

Tape Guides: OK

Tape: OK

Limit Switches

Noise, Rollers: OK

Operation: OK

Type: SUNS STND

Rails

Cleanliness: OK

Lubrication: OK

Type: T-15 LBS

Fastening: OK

Guide Shoes: OK

ELPRO 816SS

Cable Condition

Traveling: OK

Suspension: OK

Spares: OK

Kellum Grips: OK

Hoistway Equipment

Car Top

Cleanliness: OK

Maintenance Station: OK

Stop Switch: OK

Data Plate: MISSING

Light: OK

Light Guards: OK

Guides: OK

GFIC Recept: OK

Escape door locked: YES

Windows in Hoistway: NONE

Multiple Hoistways: N/A

Stenciled: NI

Hoistway Venting

Existing: NO

Motorized: N/A

Safety Bars: N/A

Key Switch: N/A

Size (3%): N/A

Door Operator / GAL MOVF

Cleanliness: OK

Door Protection: SCANNER

Lubrication: OK

Belts: OK

Chains: ADJUST

Hangers: OK

Arms: OK

Bearing: OK

Noise: OK

Tracks: OK

Upthrusts: OK

Restrictor: OK

Gibs: NI

Car Enclosure

Ventilation: OK

FAN

Walls: STAND OFF PANELS

SS FRONT

Car Lighting: OK

FLORESCENT

Ceiling: OK

SUSPENDED W / EGG CRATE

Position Indicators: OK

DIGITAL

Handrails: 1 TIER

1 ROUND @ 32”

Flooring: TILE

Car Doors: STAINLESS STEEL

Sills: ALUMINUM

Certificate Frame: N/A

Entrance Equipment

Cleanliness: OK

Lubrication: OK

Tracks: OK

Hangers: OK

Gibs: OK

Interlocks: OK

GAL

Noise: OK

Upthrust: OK

Closers: OK

SPIRATORS

Braille: OK

60” TO CENTER

Emergency Fire Box

Main Egress Landing: 1ST FLOOR

Existing in lobby: YES

Machine room key: LOD

Phase I, II keys: YES

Lunar key: YES

Tagged: YES

Car Operating Panel

Type: INNOVATION

DESIGNER SERIES

Condition: OK

Height Compliance: OK

Braille Identification: OK

Buttons: OK

Phone: PUSH TO TALK

GOES TO ALERT ONE

Phone #: 808-422-3164

Alarm Button: OK

Independent Key Sw: OK

Stop Switch: KEYED

Emergency Light: OK

Capacity Plate / Engraved: OK

Fire Fighters Instr: OK

Phase II key sw: YES

OFF / HOLD / ON

Call Cancel Button: YES

Fire Hat: YES

Certificated: NO

Hall Buttons:

Type: INNOVATION

Condition: OK

Illuminated: OK

Height: OK

Mechanical: OK

Lanterns: OK

Fire Signage: OK

EMBOSSED ON FIXTURE

Phase I key switch: YES

BYPASS / OFF / ON

Phase I instructions: YES

Pit Equipment

Cleanliness: OK

Car Buffer: OK

Cwt Buffer: N/A

Lights: OK

Light Switch: OK

Light Guards: OK

Stop Switch: OK

Ladder: OK

GFIC Recept: OK

Jack Seal: OK

PVC Liner: N/A

Shut Offs: OK

Piston Pans: N/A

Piston: OK

Rupture Valves: OK

High Pressure Vics: NO

Sump: HOLE ONLY

Pit Buckets: OK

Sprinkler: YES

Heat Head: NO

Smokes: OK

Bottom of Car

Cleanliness: OK

Safeties: N/A

Trav cable suspension: OK

Toe guard length: OK

Toe Guard Stenciled: NO

Isolation: OK

Light Fixture: NO

Light Guard: N/A

Guides: OK

Receptacle: NO

GFI Receptacle: NO

T-2410 TARGET

HONOLULU WEST, HI

TEAM PASSENGER ELEVATOR 1

CORRECTIVE ITEMS

The following minimum items need corrective action taken. Documentation of completion is required.

SEE EXECUTIVE SUMMARY

T-2410 TARGET

HONOLULU WEST, HI

TEAM PASSENGER ELEVATOR 1

GENERAL CONTRACTOR

SEE EXECUTIVE SUMMARY

END OF REPORT

................
................