Generator Set



[pic]GUARDIAN® is now doing to the commercial market what it has already done to the residential market… making standby power reliable, yet affordable. Protect your revenue stream by investing in a GUARDIAN Elite™ commercial automatic standby generator. Our GUARDIAN Elite generators are ideal for a broad range of enterprises, including restaurants, convenience stores, supermarkets, banks, fitness centers, hotels, and retail outlets.

Three-phase models range from 20-150 kW and single-phase models from 60-150 kW. They run on either natural gas or LPV, feature automotive style, liquid-cooled engines, GUARDIAN’s exclusive Whisper-Test™ feature and a corrosion-resistant aluminum enclosure option. 

Whisper Quiet Operation

GUARDIAN’s exclusive patent-pending Whisper-Test low speed exercise feature makes our GUARDIAN Elite products the quietest liquid-cooled generators on the market. Whisper-Test reduces noise by 50% during the generator’s weekly self-test cycle allowing for near silent operation that satisfies all known sound ordinances. 

Value Priced

During a utility outage, a GUARDIAN Elite will protect your revenue stream and prevent expensive losses by keeping your business… in business. Not only are our products engineered for reliability and long life, our volume production and short lead times make GUARDIAN Elite products an even better value.

• Liquid-Cooled Engine: Produces more electricity for longer outages

• Whisper-Test™: Patent-pending, self-test feature makes the GUARDIAN Elite 50% quieter during the generator’s weekly self-test cycle

• Aluminum Enclosure: Corrosion-resistance for coastal communities (60 kW and higher) 

• Longest Life Expectancy in the Industry: Over 3,000 hours of run time

• Superior Paint: Tough, textured powder coat paint finish for unmatched durability and all weather protection

• UL Listed: For safety and certified power ratings [pic]

• Clean Burning Fuel: Natural gas or LPV

Generator Set

|[pic] |[pic] |[pic] |

|[pic] |[pic] |[pic] |

|[pic] |[pic] |[pic] |

| | | |

|[pic] |[pic] |[pic] |

|20-45 kW |60-80 kW |100-150 kW |

|[pic] |[pic] |[pic] |

| | | |

|Model Number |QT02016 |QT02516 |QT03524 |QT04524 |

|Rated Power LP (kW) |20 |25 |35 |45 |

|Rated Power NG (kW) |20 |25 |35 |43 |

|Amps @ 208V, 3Ø |70 |87 |122 |156 |

|Amps @ 480V, 3Ø |n/a |n/a |53 |68 |

|Voltage @ 60 Hz |120/208 |120/208 |120/208, 277/480 |120/208, 277/480 |

|Phase |Three |Three |Three |Three |

|Frequency |60 Hz |60 Hz |60 Hz |60 Hz |

|Engine/Alternator RPM |3600/3600 |3600/3600 |3600/3600 |3600/3600 |

|Engine |1.6L OHC 4 cyl. |1.6L OHC 4 cyl. |2.4L OHC 4 cyl. |2.4L OHC 4 cyl. |

|Fuel Consumption LP |125 (3.44) |175 (4.81) |222.3 (6.1) |286 (7.86) |

|(cu.ft./hr.)/(gal./hr.) | | | | |

|Fuel Consumption NG (cu.ft./hr.) |315 |437 |560 |720 |

|EPA/CARB Certified |Yes |Yes |No |No |

|Fuel |Natural Gas |Natural Gas |Natural Gas |Natural Gas |

| |LP Vapor |LP Vapor |LP Vapor |LP Vapor |

|Engine Cooling |Liquid |Liquid |Liquid |Liquid |

|Controls |R-Series |R-Series |R-Series |R-Series |

|UL 2200 (US and Canada) |Yes |Yes |Yes |Yes |

|Sound Output dB(A) at 23 ft. with generator |72 |73 |71 |72 |

|operating at full load | | | | |

|Sound Output dB(A) at 23 ft. with generator |62 |63 |57 |58 |

|in WhisperTest™ low speed exercise mode | | | | |

|Main Line Circuit Breaker |80 Amp |100 Amp |150, 60 Amp |175, 80 Amp |

|Aluminum Enclosure Option |Yes |Yes |Yes |Yes |

|Dimensions (L" x W" x H") |71 x 29.5 x 36 |71 x 29.5 x 36 |77 x 33.5 x 45 |77 x 33.5 x 45 |

|Unit Wt. (lbs.) (steel/aluminum) |784/694 |794/704 |1393/1276 |1414/1297 |

Controls and Transfer Switch

|[pic] |[pic] |[pic] |

|[pic] |[pic] |[pic] |

|[pic] |[pic] |[pic] |

| | | |

|[pic] |[pic] |[pic] |

|R-Series Digital Controller |H-100 Digital Controller |Transfer Switch |

|[pic] |[pic] |[pic] |

| | | |

|7 LED Indicator Lights |Standard |

|High Temperature Shutdown |Standard |

|Low Coolant Level Shutdown |Standard |

|Automatic Voltage Regulator with Over-voltage Protection |

|Standard |

| |

|Voltage Regulation (at steady state from no load to 100% load |

|± 1.0 % |

| |

|Frequency Regulation (at steady state from no load to 100% load) |

|± 0.5% |

| |

|Engine Start Sequence |Cyclic Cranking: Initially 15 sec. on, then 7 sec. rest, 7|

| |sec. on. 90 sec. maximum duration |

|Safety Fuse |Standard |

|Starter Lockout |Starter cannot re-engage until 5 sec. after engine has |

| |stopped |

|2 Amp Battery Charger |Standard |

|Engine Warm-up |10-15 seconds |

|Engine Cool-down |1 minute |

|Mode Switch |

| |

| |

|Auto Position |

|Utility Failure / 7 day exerciser |

| |

|Off Position |

|Stops unit. Power is removed. Control and charger still operate. |

| |

|Manual/Test Position |

|Start with starter control, unit stays on. If utility fails, transfer to load takes place |

| |

|Automatic Weekly Exerciser with Selectable Low Speed Exercise |Standard |

................
................

In order to avoid copyright disputes, this page is only a partial summary.