PowerFlex 753 and PowerFlex 755 Pre ... - Rockwell Automation
Technical Data
PowerFlex 753 and PowerFlex 755 Pre-engineered FasTrac Packaged Drives
Catalog Numbers 24F, 24G
Topic
Page
Summary of Changes
1
Product Overview
2
Catalog Number Explanation
3
Specifications
7
Options
9
Drawings
14
Maintenance
14
Enclosure Information
14
Mechanical Installation
32
Electrical Installation
34
Output Power Wiring
38
Additional Resources
41
Summary of Changes
This publication contains new and updated information as indicated in the following table.
Topic
Page
Added Fahrenheit to NEMA / UL Type 12 ambient temperature design
6
PowerFlex 753 and PowerFlex 755 Pre-engineered FasTrac Packaged Drives
Product Overview
Rockwell Automation? PowerFlexTM 753 and 755 drives are now available in a Pre-engineered FasTrac Packaged Drive program. The Pre-engineered FasTrac Packaged Drives program provides PowerFlex 750-Series drives packaged with a much larger offering of factory-mounted options than what is normally available with a standard drive product. With the Pre-engineered FasTrac program, you receive packaged PowerFlex 753 and 755 drives in as little as 20 business days.
The Pre-engineered FasTrac program is a separate, centrally managed program. It combines the capabilities of Rockwell Automation low voltage drives with the Local Solution Centers. As orders are received, they are immediately released to a manufacturing location based on capacity.
Benefits: ? A proven and tested design ? Quality drives and quick turnaround ? Pre-engineered packages to deliver sizing, wiring, and calculations ? Some ratings meet CSA requirements (contact Rockwell Automation for clarification). Available only in Canada. ? Available in an assortment of environmental protection enclosures: NEMA 1, 12, 3R, or 4X (indoor and outdoor)
This document contains information that is related to the Rockwell Automation PowerFlex 750-Series Pre-engineered FasTrac Packaged Drives program. The document is intended to provide drive catalog numbers, specifications, options and accessories, enclosures, and dimension information.
IMPORTANT
This information can be useful when specifying an application of a Pre-engineered FasTrac Packaged PowerFlex 750-Series AC drive. Be advised that this information is for reference only and subject to change at any time.
2
Rockwell Automation Publication 750-TD002E-EN-P - March 2018
PowerFlex 753 and PowerFlex 755 Pre-engineered FasTrac Packaged Drives
Catalog Number Explanation
The following catalog information is for PowerFlex 750-Series Drives Pre-engineered FasTrac packaged drives. Contact your Rockwell Automation representative for product option rules.
Position
1...3 4
5
6
7 8...10 11
12
13
14
15
16
17
24G 1 1 R D 096 A A 0 N N N N - ND - P3...
a
b
c
d
e
f
g
h
i
a
Drive
Code
Type
24F
PowerFlex 753
24G
PowerFlex 755
b
Input Type
Code
Type
1
AC & DC Input with Precharge
A
AC Input w/ precharge, no DC terminals
Code I A J
H S R X (indoor)
C (outdoor)
c
Enclosure Type and Conformal Coating
Enclosure Rating
Frame
Enclosure Style
Conformal Coating
NEMA 1 / IP20
1 Single drive Yes
NEMA 1 / IP20
2...7 Single drive Yes
NEMA 12 / IP54 (fan and filter)
1 Single drive Yes
NEMA 12 / IP54 (fan and filter)
2...7 Single drive Yes
NEMA 3R / IP24
1 Single drive Yes
NEMA 3R / IP24
2...7 Single drive Yes
NEMA 4X / IP66 (non-vented)
2...5 Single drive Yes
NEMA 4X / IP66 (fan and filter)
2...5 Single drive Yes
d
Version and Voltage Rating
Code
Input Voltage Source Type
D
480V AC
3 PH
E
600V AC(1)
3 PH
(1) Only available in Canada.
e
DC Precharge No No
Output amps, Hp ratings @ 480V AC Input
Code
Amps
ND Hp
HD Hp Frame Size
2P1
2.1
1
0.75
1 or 2
3P4
3.4
2
1.5
1 or 2
5P0
5
3
3
1 or 2
8P0
8
5
5
1 or 2
011
11
7.5
5
1 or 2
014
14
10
7.5
1 or 2
022
22
15
10
2
027
27
20
15
3
034
34
25
20
3
040
40
30
25
3
052
52
40
30
4
065
65
50
40
4
077
77
60
50
5
096
96
75
60
5
125
125
100
75
6
156
156
125
100
6
186
186
150
125
6
248
248
200
150
6
302
302
250
200
7
361
361
300
250
7
415
415
350
300
7
477
477
400
7(1)
(1) PowerFlex 755 only.
Rockwell Automation Publication 750-TD002E-EN-P - March 2018
3
PowerFlex 753 and PowerFlex 755 Pre-engineered FasTrac Packaged Drives
e (cont'd)
Output amps, Hp ratings @ 600V AC Input(1)
Code
Amps
ND Hp
HD Hp
1P7
1.7
1
2P7
2.7
2
1
3P9
3.9
3
2
6P1
6.1
5
3
009
9
7.5
5
011
11
10
7.5
017
17
15
10
022
22
20
15
027
27
25
20
032
32
30
25
041
41
40
30
052
52
50
40
063
63
60
50
077
77
75
60
099
99
100
75
125
125
125
100
144
144
150
125
192
192
200
150
242
242
250
200
289
289
300
250
(1) 600V AC rating is only available in Canada.
Frame Size 3 3 3 3 3 3 3 3 4 4 5 5 6 6 6 6 6 7 7 7
f
Filtering and Common Mode Capacitor Configuration
Code
Filtering
Default CM Cap Connection
A
Yes
Jumper removed
J
Filtered, CN jumper installed
g
Dynamic Braking
Code
Internal Resistor
Internal Transistor
A
No
Yes
N
No
No
h
HIM
Code
Version
0
No HIM - Blank plastic inserted (drive mounted)
3
Full numeric LCD HIM (drive mounted)
5
Programmer only LCD HIM (drive mounted)
6
Door mounted full numeric LCD HIM
7
Door mounted Programmer only LCD HIM
i
Code
Options
-ND
Normal duty
-HD
Heavy duty
Input Devices
-P3
Circuit breaker
-P4
Drive/Bypass mode circuit breaker
-P6
Fused disconnect
-P7
Drive/Bypass mode fused disconnect
P13
Circuit breaker (65 kA)
P14
Drive/Bypass mode circuit breaker (65 kA)
Reactors
-L1
Input reactor, 3%
-L2
Output reactor, 3%
-L3
Input reactor, 5%
-L4
Output reactor, 5%
Enclosure Options
-H1
Lexan HIM cover (with a viewing window)
-H2
Metallic HIM cover (solid door, no window)
-E5
Enclosure space heater
LK12
12 in. enclosure leg kit Available on frames 1...5 only.
LK18
18 in. enclosure leg kit Available on Frames 1...4 only.
LK24
24 in. enclosure leg kit Available on Frames 1...4 only.
PH4
4 in. Plinth for frame 6 & 7, Frame 7 with bypass and NEMA 1, 12, and 3R only
PH4A
4 in. Plinth for frame 7only without bypass and NEMA 1, 12, and 3R only
4
Rockwell Automation Publication 750-TD002E-EN-P - March 2018
Code
-B0 -B1
-C1
-F5 HF
-S51 -S59W -S59G -S59R -S60R -S60A -S68 -S53 -S54 -S55 -S57 -S66 -S85 ETM1 ETM2
i (cont'd)
Options
Option
Bypass No bypass
Manual bypass Control Power
Drive only control power, 60 Hz only Power Filtering
Transient voltage surge suppressor Externally mounted harmonic filter Operator Devices
Hand/Off/Auto selector switch (start/stop/speed reference)
Run pilot light (white) Run pilot light (green) Run pilot light (red) Drive fault pilot light (red) Drive fault pilot light (amber) Speed potentiometer (1 Turn) Control power on pilot light (white) Drive and bypass mode pilot lights (amber) Local start/stop push buttons Drive reset push button Drive/Bypass (B1, if present) disable mushroom
push button Local stop start push buttons
Elapse time meter Elapse time meter
PowerFlex 753 and PowerFlex 755 Pre-engineered FasTrac Packaged Drives
i (cont'd)
Control Interface
PS1
24V DC power supply
S56
Local / remote SEL SW
STO
PowerFlex 750 Safe Torque Off card
S67
Motor high temp circuit
S87
Motor high temp circuit
J4
Run relay with Aux that is wired to terms (8 A contacts)
J42
Run relay with Aux that is wired to terms (8 A contacts)
J2
FLT relay with Aux that is wired to terms (8 A contacts)
J22
FLT relay with Aux that is wired to terms (8 A contacts)
RS
Emergency stop circuit W/Safe Torque Off
SIB
SCADA interface I/O option
SIA
SCADA interface I/O option
AP
Approval Drawings
Feedback
-F0
None
-F1
Standard encoder
I/O
N
None
-IA
Standard
-IB
Standard
Communication
-MN
None
-MD
DeviceNet
-MC
ControlNet (coax)
-MF
ControlNet (fiber)
-MS
RS-485 DF1
-MH
RS-485 HVAC
-MP
PROFIBUS DPV1
-MI
INTERBUS
-ME
EtherNet/IP
-MB
BACnet/IP
-MT
Dual-port EtherNet/IP
Rockwell Automation Publication 750-TD002E-EN-P - March 2018
5
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- mac address filtering setup
- positive psychology and the humanistic tradition
- fips 140 2 non proprietary security policy
- i 765 application for employment authorization uscis
- thermo scientific ramsey micro tech 9101
- programming linux to qspi emmc on the smart vision avnet
- monitoring ethernet traffic with tolomatic acs managed
- powerflex 753 and powerflex 755 pre rockwell automation
- lab 1 familiarity with virtualbox and pcap tools
- 4ge 2pots wifi epon onu user manual tp link
Related searches
- pre surgery history and physical
- pre surgical history and physical
- cross company automation group
- cross automation greensboro nc
- cross automation belmont nc
- cross automation nc
- history and physical pre op
- cross automation charlotte
- cross automation belmont
- difference between pre qualified and pre approved
- pre k themes and units
- pre and post assessment tools