Subbase Diesel Fuel Tanks Double-Wall ... - Kohler Power

[Pages:4]Double-Wall Subbase Tank

GENERATOR ACCESSORIES

Subbase Diesel Fuel Tanks

Double-Wall Subbase Fuel Tanks (UL Listed)

Applicable to the following: 20ROZJB 20--230REOZJB

Secondary Containment (SC) Tank

D The above-ground rectangular secondary containment tank mounts directly to the generator set. The secondary containment fuel tank mounts below the generator set skid (subbase).

D Both the inner and outer UL-listed tanks have emergency relief vents.

D The containment tank's double-layer construction protects against fuel leaks and ruptures. The inner tank is sealed inside the outer tank. The outer tank contains the fuel if the inner tank leaks or ruptures.

D The subbase fuel tank is compatible with a weather housing, weather enclosure, or sound shield enclosure.

Double-Wall Subbase Tank with Optional Weather Enclosure

G6-56 5/02

Fuel Tank Features and Options

1

11 10 9 8 7 6

54 3

GM16904-

2

1. Inner tank leak alarm kit 2. Emergency pressure relief vent outer tank (standard) 3. Emergency pressure relief vent inner tank (standard) 4. Fuel supply line 5. Normal vent with riser and mushroom cap (standard) 6. Fuel return line

7. Lockable/sealed fill cap with riser (standard) 8. Mechanical fuel gauge (standard) 9. Low fuel level switch for controller alarm

(compatible with Decision-Makert3+ and Decision-Makert550) 10. Day tank kit 11. 1/2 in. NPT for leak detection switch

Figure 1 Double-Wall Subbase Fuel Tanks (Secondary Containment)

1. Emergency vent per NFPA 30 2 in. NPT 227--295 L (60--78 gal.) 3 in. NPT 511--1030 L (135--272 gal.) 4 in. NPT 1180--2059 L (312--544 gal.)

2. 2 in. NPT raised manual fill cap with 51 mm (2 in.) riser 3. 1 1/2 in. NPT level gauge 4. 2 in. NPT normal vent with 127 mm (5 in.) riser and mushroom cap 5. 3/8 in. diptube with check valve, (female) customer fuel supply connection

3/8 in. NPT all kits except 1030/1548/2059 L (272/409/544 gal.) 1/2 in. NPT 1030/1548/2059 L (272/409/544 gal.) 6. 3/8 in. diptube with check valve, 3/8 in. NPT (female) customer fuel return connection 7. 2 in. NPT with low level switch 8. 2 in. NPT for sensor/pump control float 9. 1/2 in. NPT for overflow, 7.6 L (2 gpm) pump maximum 10. 3/8 in. NPT for tank fill

Figure 2 Fuel Tank Fittings Top View (Figure 1, View A-A)

GM16904-

G6-56 5/02

Fuel Tank Weights and Dimensions

Double-Wall Subbase Fuel Tanks

kW Kit No.

Capacity, L (gal.) Length, mm (in.) Width, mm (in.) Height, mm (in.)

GM16904-KP1 20 GM16904-KP2

227 (60) 295 (78)

2200 (86.61) 2600 (102.36)

1040 (40.94)

215 (8.5)

GM16904-KP3

450 (119)

2000 (78.74)

460 (18.0)

GM16904-KP1 GM16904-KP2 30 GM16904-KP3 GM16904-KP4

227 (60) 295 (78) 450 (119) 511 (135)

2200 (86.61) 2600 (102.36) 2000 (78.74) 2200 (86.61)

1040 (40.94)

215 (8.5) 460 (18.0)

GM16904-KP1 GM16904-KP2

227 (60) 295 (78)

2200 (86.61) 2600 (102.36)

215 (8.5)

40 GM16904-KP3

450 (119)

2000 (78.74)

1040 (40.94)

GM16904-KP4

511 (135)

2200 (86.61)

460 (18.0)

GM16904-KP5

650 (172)

2600 (102.36)

GM16904-KP2

295 (78)

2600 (102.36)

215 (8.5)

GM16904-KP4 50

GM16904-KP5 GM16904-KP6

511 (135) 650 (172) 900 (238)

2200 (86.61) 2600 (102.36)

1040 (40.94)

460 (18.0) 610 (24.0)

GM16904-KP2

295 (78)

2600 (102.36)

215 (8.5)

GM16904-KP4 60 GM16904-KP5

GM16904-KP6 GM16904-KP7

511 (135) 650 (172) 900 (238) 1007 (266)

2200 (86.61) 2600 (102.36) 2800 (110.24)

1040 (40.94)

460 (18.0) 610 (24.0)

GM16904-KP4 GM16904-KP5 80 GM16904-KP6 GM16904-KP7 GM16904-KP9

511 (135) 650 (172) 900 (238) 1007 (266) 1250 (330)

2200 (86.61) 2600 (102.36) 2800 (110.24)

1040 (40.94)

460 (18.0) 610 (24.0) 760 (30.0)

GM16904-KP5 GM16904-KP6 100 GM16904-KP8

650 (172) 900 (238) 1180 (312)

2600 (102.36) 3200 (125.98)

1040 (40.94)

460 (18.0) 610 (24.0)

GM16904-KP9 GM16904-KP11

1250 (330) 1500 (396)

2800 (110.24) 3200 (125.98)

760 (30.0)

GM16904-KP5 GM16904-KP6 125 GM16904-KP8 GM16904-KP11

650 (172) 900 (238) 1180 (312) 1500 (396)

2600 (102.36) 3200 (125.98)

1040 (40.94)

460 (18.0) 610 (24.0) 760 (30.0)

GM16904-KP7 150 GM16904-KP8

GM16904-KP11

1007 (266) 1180 (312) 1500 (396)

2800 (110.24) 3200 (125.98)

1040 (40.94)

610 (24.0) 760 (30.0)

GM16904-KP7 180 GM16904-KP10

GM16904-KP12

1007 (266) 1310 (346) 1953 (516)

2800 (110.24) 3400 (133.86)

1040 (40.94)

610 (24.0) 915 (36.0)

GM16904-KP13 1030 (272)

3200 (125.98)

460 (18.0)

200 GM16904-KP14 1548 (409)

3400 (133.86)

1250 (49.21)

610 (24.0)

GM16904-KP15 2059 (544)

3600 (141.73)

760 (30.0)

GM16904-KP13 1030 (272)

3200 (125.98)

460 (18.0)

230 GM16904-KP14 1548 (409)

3400 (133.86)

1250 (49.21)

610 (24.0)

GM16904-KP15 2059 (544)

3600 (141.73)

760 (30.0)

Weight, kg (lb.) 303 (667) 344 (759) 370 (815) 303 (667) 344 (759) 370 (815) 406 (894) 303 (667) 344 (759) 370 (815) 406 (894) 454 (1001) 344 (759) 406 (894) 454 (1001) 532 (1173) 344 (759) 406 (894) 454 (1001) 532 (1173) 565 (1246) 406 (894) 454 (1001) 532 (1173) 565 (1246) 640 (1410) 454 (1001) 532 (1173) 628 (1385) 640 (1410) 709 (1564) 454 (1001) 532 (1173) 628 (1385) 709 (1564) 565 (1246) 628 (1385) 709 (1564) 565 (1246) 660 (1455) 828 (1826) 616 (1358) 743 (1639) 873 (1925) 616 (1358) 743 (1639) 873 (1925)

Est. Fuel Supply, Hours at 60 Hz with Full Load

24 32 48 16 24 40 48 16 24 32 40 48 16 32 40 48 16 24 32 40 48 16 24 32 40 48 16 24 32 40 48 16 24 32 40 16 24 32 16 24 32 16 24 32 16 24 32

G6-56 5/02

KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-565-3381, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444

Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65)264-6422, Fax (65)264-6455

Fuel Tank Features and Accessories

Standard Features

D Heavy-gauge construction D Integral stub-up area D Removable end channel for easy access to stub-up

area D UL listed D Emergency pressure-relief vent outer tank D Lockable fill cap and riser, 2 in. NPT D Low fuel level switch for controller alarm

(optional with Decision-Makert1 controller) D Mechanical fuel gauge D Normal vent with riser and mushroom cap D Emergency pressure-relief vent inner tank D Fuel supply and fuel return openings D Basin drain D Float opening for pump control D Overflow opening D Pump and motor-mounting pad D Tank fuel fill opening for day tank

Accessories

D Inner tank leak alarm kit

D Electronic-control day tank kit includes transfer pump, 120 VAC, 1/3 HP motor, and controls; requires a 20- or 40-foot wiring harness; 7.6 Lpm (2 gpm)

D Relay control day tank kit includes transfer pump, 120 VAC, 1/3 HP motor, and controls; 7.6 Lpm (2 gpm)

DISTRIBUTED BY:

Availability is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohlerr generator distributor for availability.

? 2002 by Kohler Co. All rights reserved.

G6-56 5/02

................
................

In order to avoid copyright disputes, this page is only a partial summary.