Secondar D Copper - CME Wire

[Pages:2]Secondary URD Copper

XLPE Insulated, 600 V

Features

RUS accepted.

Single conductors are UL Listed as Type USE-2.

Excellent heat, ozone, oil and chemical resistance.

Resistant to tear and abrasion.

Suitable for direct burial.

Application

Used for secondary distribution and underground service at 600 volts or less.

May be used in ducts or direct burial.

Standards

ICEA S-105-692

600 V Single Layer Thermoset Insulated Utility Underground Distribution Cable.

UL 854

Service Entrance Cables.

Specifications

Maximum operating voltage:

? 600 volts Maximum conductor operation temperatures:

? 90 ?C wet and dry

Engineering Information

1. Conductor: Soft annealed copper, solid per ASTM B3, Class B, compressed stranding or unilay compressed per ASTM B8.

2. Separator: A suitable opaque tape, as required.

3. Insulation

Phase Conductor: Black thermoset cross-linked polyethylene (XLPE).

Neutral conductor: Black thermoset cross-linked polyethylene (XLPE), with three yellow extruded stripes.

Conductor Phase ID: Ink printed.

1 2 3

Configurations Duplex: One black phase insulated conductor and one neutral insulated conductor cabled together. Triplex: Two black phase insulated conductors (A & B) and one neutral insulated conductor cabled together. Quadruplex: Three black phase insulated conductors (A, B & C) and one neutral insulated conductor cabled together.

Duplex Tr i p l e x

Secondary URD Cable ? Copper

Technical Data

Duplex XLPE Insulated, 600 V

Size AWG or kcmil

8-7/w

6-7/w

4-7/w

Phase Conductor

Number of

Strands 7 7 7

Insulation Thickness

mil 60 60 60

Size AWG or kcmil

8

6

4

Neutral Conductor

Number of

Strands 7 7 7

Insulation Thickness

mil 60 60 60

The above data are approximate and subject to normal manufacturing tolerances. Other sizes available upon request. Ampacities: Refer to beginning of section.

Quadruplex

Cable OD

Single Phase mil 0.27 0.30 0.35

Complete Cable in 0.53 0.60 0.70

Weight XLPE lb/kft 138 207 313

CME Wire and Cable | 495 Horizon Drive NE, Suite 100, Suwanee, Georgia 30024 | | 770.623.0001

? 2014 CME Wire and Cable, Inc. All Rights Reserved.

February 18, 2016

Secondary URD Copper, XLPE Insulated, 600 V

Technical Data continued

Triplex XLPE Insulated, 600 V

Size AWG or kcmil

6-7/w 4-7/w 2-7/w 2-7/w 1-19/w 1/0-19/w 1/0-19/w 2/0-19/w 2/0-19/w 2/0-19/w 2/0-19/w 3/0-19/w 3/0-19/w 4/0-19/w 4/0-19/w 4/0-19/w 250-37/w 350-37/w 350-37/w 350-37/w 500-37/w 500-37/w

Phase Conductor

Number of

Strands 7 7 7 7 19 19 19 19 19 19 19 19 19 19 19 19 37 37 37 37 37 37

Insulation Thickness

mil 60 60 60 60 80 80 80 80 80 80 80 80 80 80 80 80 95 95 95 95 95 95

Size AWG or kcmil

6 4 4 2 3 2 1/0 1 2/0 2/0 2/0 1/0 3/0 2/0 4/0 4/0 3/0 4/0 350 350 300 350

Neutral Conductor

Number of

Strands 7 7 7 7 7 7 19 19 19 19 19 19 19 19 19 19 19 19 37 37 37 37

Insulation Thickness

mil 60 60 60 60 60 60 80 80 80 80 80 80 80 80 80 80 80 80 95 95 95 95

Cable OD

Single Phase

mil 0.30 0.35 0.41 0.41 0.49 0.53 0.53 0.57 0.57 0.57 0.57 0.62 0.62 0.68 0.68 0.68 0.75 0.85 0.85 0.85 0.98 0.98

Complete Cable

in 0.65 0.75 0.87 0.87 1.05 1.13 1.13 1.23 1.23 1.23 1.23 1.34 1.34 1.46 1.46 1.46 1.62 1.84 1.84 1.84 2.12 2.12

Weight XLPE

lb/kft 311 470 637 721 813

1,007 1,151 1,262 1,428 1,428 1,428 1,568 1,776 2,199 2,213 2,213 2,342 3,148 3,615 3,615 4,433 4,598

Quadruplex XLPE Insulated, 600 V

Size AWG or kcmil

6-7/w 4-7/w 2-7/w 2-7/w 1-19/w 1/0-19/w 1/0-19/w 2/0-19/w 2/0-19/w 3/0-19/w 3/0-19/w 4/0-19/w 4/0-19/w 250-37/w 300-37/w 350-37/w 350-37/w

Phase Conductor

Number of

Strands 7 7 7 7 19 19 19 19 19 19 19 19 19 37 37 37 37

Insulation Thickness

mil 60 60 60 60 80 80 80 80 80 80 80 80 80 95 95 95 95

Size AWG or kcmil

6 4 4 2 3 2 1/0 1 2/0 1/0 3/0 2/0 4/0 3/0 4/0 4/0 350

Neutral Conductor

Number of

Strands 7 7 7 7 7 7 19 19 19 19 19 19 19 19 19 19 37

Insulation Thickness

mil 60 60 60 60 60 60 80 80 80 80 80 80 80 80 80 80 95

Cable OD

Single Phase

mil 0.30 0.35 0.35 0.41 0.38 0.41 0.53 0.49 0.57 0.53 0.62 0.57 0.68 0.62 0.68 0.68 0.85

Complete Cable

in 0.73 0.84 0.98 0.98 1.17 1.27 1.27 1.38 1.38 1.50 1.50 1.63 1.63 1.82 1.95 2.06 2.06

Weight XLPE

lb/kft 414 627 877 961

1,123 1,391 1,534 1,738 1,905 2,160 2,369 2,689 2,951 3,217 3,857 4,353 4,821

The above data are approximate and subject to normal manufacturing tolerances. Other sizes available upon request. Ampacities: Refer to beginning of section.

February 18, 2016

CME Wire and Cable | 495 Horizon Drive NE, Suite 100, Suwanee, Georgia 30024 | | 770.623.0001

? 2014 CME Wire and Cable, Inc. All Rights Reserved.

................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download