Utility Wire & Cable

Utility Wire & Cable

Code Name Aega Akron Alliance Almond Alton Ames Amherst Anaheim Anona Appaloosa Apple Apricot Arabian Arbutus Arca Arch Ar temia Aster Azusa Bach Bard Barnacles Bay Beaumont Beech Belgian Beloit Bergen Bittern Bitterroot Bluebell Bluebird Bluebonnet Bluejay Bobolink Bosch Brahma Brahms Brant Breadfruit Brenau Bronco Bruegel Buckeye Bull Bunting Butte Butternut

Cond. Size 3/0 AWG 30.58 MCM 246.9 MCM 1/0 AWG 48.69 MCM 77.47 MCM 195.7 MCM 155.4 MCM 336.4 MCM 4/0 AWG 6 AWG 4 AWG 4 AWG 795 MCM 4/0 AWG 2 AWG 4 AWG 2/0 AWG 123.3 MCM 3/0 AWG 8 AWG 4 AWG 6 AWG 1113 MCM 2 AWG 2 AWG 4/0 AWG 1/0 AWG 1272 MCM 2750 MCM 1033.5 MCM 2156 AWG 3500 MCM 1113 MCM 1431 MCM 500 MCM 203.2 MCM 2/0 AWG 397.5 MCM 636 MCM 1/0 AWG 336.4 MCM 3/0 AWG 4/0 AWG 1/0 AWG 1192.5 MCM 312.8 MCM 4 AWG

Code Name Reference

Pg. # Code Name 14 Cairo 3 Camellia 3 Canary 11 Canna 3 Canton 3 Cardinal 3 Carnation 3 Cattail 11 Cavolinia 15 Cenia 11 Cerapus 11 Cezanne 16 Cherrystone 2 Chestnut 13 Chickadee N/A Chihuahua 13 Chola 1 Choppin 3 Chow N/A Chukar 21 Claflin 13 Clam 16 Clemson 6 Clio 11 Clydesdale 16 Cochin 21 Cockle 22 Cockscomb 6 Collie 2 Columbine 2 Conch 7 Condor 2 Converse 6 Coot 7 Coreopsis N/A Corot 7 Cosmos N/A Costena 5 Cowry N/A Cowslip 22 Crab 15 Crayfish N/A Criollo 11 Cuckoo 12 Curlew 6 Cuttlefish 3 Cyclops 11 Dachshund

Cond. Size 465.4 MCM 1000 MCM 900 MCM 397.5 MCM 394.5 MCM 954 MCM 1431 MCM 750 MCM 2/0 AWG 1/0 AWG 4/0 AWG 2 AWG 3/0 AWG 1 AWG 397.5 MCM 6 AWG 6 AWG 4/0 AWG 2 AWG 1780 MCM 6 AWG 2 AWG 2 AWG 2/0 AWG 4 AWG 211.3 MCM 2 AWG 900 MCM 6 AWG 1351.5 MCM 2 AWG 795 MCM 2/0 AWG 795 MCM 1590 MCM 4/0 AWG 477 MCM 1/0 AWG 336.4 MCM 2000 MCM 4 AWG 2/0 AWG 1/0 AWG 795 MCM 1033.5 MCM 4/0 AWG 4/0 AWG 4 AWG

Pg.# Code Name 3 Daffodil 2 Dahlia 6 Daisy 1 Darien 3 Dartmouth 6 Daumier 2 Davidson 2 Degas 14 Delgado 14 Dipper 14 Doberman

N/A Dorking 14 Dotterel 11 Dove 5 Drake 12 Dufay 15 Duke N/A Dungeness 12 Dyke 7 Eagle 21 Earlham 14 Echinus 21 Egret 14 El Greco 15 Elgin

7 Emory 14 Erskine 2 Eskimo 12 Everett 2 Fairfield 14 Falcon 6 Fig 22 Filbert 6 Finch 2 Flag N/A Flamingo 1 Flicker 15 Flint 14 Flustra 2 Fordham 13 French-Coach 13 Fulgar 15 Furman 6 Fusus 6 Gable 14 Gammarus 13 Gannet 12 Gelding

Cond. Size 350 MCM 556.5 MCM 266.8 MCM 559.5 MCM 400 MCM 500 MCM 3/0 AWG 250 MCM 4 AWG 1351.5 MCM 2 AWG 190.8 MCM 176.9 MCM 556.5 MCM 795 MCM 250 MCM 600 MCM 2/0 AWG 2 AWG 556.5 MCM 4/0 Awg 1/0 Awg 636 MCM 3/0 MCM 652.4 MCM 500 MCM 6 AWG 4 AWG 2 AWG 750 MCM 1590 MCM 3/0 AWG 3/0 AWG 1113 MCM 700 MCM 666.6 MCM 477 MCM 740.8 MCM 3/0 AWG 1000 MCM 6 AWG 3/0 AWG 700 MCM 4 AWG 1/0 AWG 1/0 AWG 666.6 MCM 336.4 MCM

1-833-895-9473



Pg.# Code Name 1 German-Coach 1 Gladiolus 1 Goldenrod 3 Goldentuft 21 Gonzaga

N/A Gould 23 Goya N/A Grackle 21 Grapefruit 6 Greeley 12 Grosbeak 7 Grouse 7 Grullo 5 Guinea 6 Hackberry N/A Hackney 21 Haiotis 13 Hals 23 Handel

5 Hanoverian 23 Harrier 13 Harvard 6 Hawk N/A Hawkweed 3 Hawthorn 21 Haydn 22 Heeler 12 Hen 21 Heuchera 22 Hickory 7 Hippa 11 Hofstra 11 Holbein 6 Hollins 1 Holyoke 6 Hornbeam 5 Huckleberry 3 Hunter 13 Hurricane 21 Hyacinth 16 Ibis 13 Iris 21 Ives 13 Janthina N/A Jessamine 13 Joist 6 Joree 15 Kenyon

Cond. Size 4 AWG 1510.5 MCM 954 MCM 450 MCM 300 MCM 250 MCM 2/0 AWG 1192.5 MCM 1033.5 MCM 927.2 MCM 636 MCM 80.0 MCM 2/0 AWG 159 MCM 266.8 MCM 4 AWG 6 AWG 350 MCM 1 AWG 3/0 AWG 4 AWG 1/0 AWG 477 MCM 1000 MCM 1192.5 MCM 1/0 AWG 1/0 AWG 477 MCM 650 MCM 4 AWG 6 AWG 250 MCM 4/0 AWG 3/0 AWG 500 MCM 4 AWG 477 MCM 2/0 AWG 500 MCM 500 MCM 397.5 MCM 2 AWG 2/0 AWG 1/0 AWG 1750 MCM 1/0 AWG 2515 MCM 1 AWG

Pg. # 16 2 2 1 21 N/A N/A 6 N/A 3 6 7 15 7 11 15 13 N/A N/A 15 12 21 5 2 2 N/A 12 5 1 11 13 21 N/A 22 22 N/A 11 22 15 1 5 1 N/A 14 2 N/A 7 21

Code Name Reference

Code Name Kingbird Kiwi Lafayette Lapwing Lark Larkspur Laurel Leda Leghorn Lepas Les Boules Lilac Limpet Lindin Linnet Lippizaner Listz Lully Lupine Magnolia Malamute Mallard Marigold Mar tin McNeil Meadowsweet Melita Mercer Merlin Minex Minorca Mistletoe Molles Monet Monmouth Moreau Morgan Morochuca Mozar t Mulberry Murex Mursia Mussel Mustang Nannynose Narcissus Nassa Nastur tium

Cond. Size 636 MCM 2167 MCM 2/0 AWG 1590 MCM 397.5 MCM 1033.5 MCM 266.8 MCM 1/0 AWG 134.6 MCM 4/0 AWG 864.9 MCM 795 MCM 336.4 MCM 2 AWG 336.4 MCM 336.4 MCM 1 AWG 500 MCM 2500 MCM 954 MCM 1/0 AWG 795 MCM 113 MCM 1351.5 MCM 350 MCM 600 MCM 3/0 AWG 4 AWG 336.4 MCM 6 AWG 110.8 MCM 556.5 MCM 397.5 MCM 1 AWG 4/0 AWG 250 MCM 4 AWG 6 AWG 4/0 AWG 266.8 MCM 1/0 AWG 3/0 AWG 2 AWG 2 AWG 336.4 MCM 1272 MCM 2/0 AWG 715.5 MCM

Pg. # Code Name 6 Neritina 7 Niagara 23 Notre Dame 7 Nuthatch 5 Oilnut 2 Oldenburg 1 Olive 13 Orange 7 Orchid 13 Oriole 6 Ortolan 2 Osprey 14 Ostrich

N/A Oxlip 5 Oyster 15 Palomino

N/A Paludina N/A Pansy

2 Parakeet 2 Parrot 12 Partridge 6 Patella 2 Paw Paw 6 Peach N/A Peachbell 1 Peacock 14 Pear 21 Pecan 5 Pekingese 13 Pelican 7 Penguin 1 Peony N/A Percheron N/A Periwinkle 22 Persimmon N/A Petrel 15 Petunia 15 Pheasant N/A Phlox 11 Pigeon 14 Pignut 14 Pinto 14 Planetree 15 Plover 14 Pomegranate 2 Poppy 14 Portunus 2 Pratt

Cond. Size 1/0 AWG 350 MCM 1/0 AWG 1510.5 MCM 1/0 AWG 4/0 AWG 4/0 AWG 2/0 AWG 636 MCM 336.4 MCM 1033.5 MCM 556.5 MCM 300 MCM 4/0 AWG 4 AWG 2 AWG 6 AWG 1 AWG 556.5 MCM 1510.5 MCM 266.8 MCM 6 AWG 556.5 MCM 2 AWG 6 AWG 605 MCM 4 AWG 2/0 AWG 6 AWG 477 MCM 4/0 AWG 300 MCM 2/0 AWG 4 AWG 2/0 AWG 101.8 MCM 750 MCM 1272 MCM 3/0 AWG 3/0 AWG 2 AWG 4 AWG 4/0 AWG 1431 AWG 4/0 AWG 1/0 AWG 4/0 AWG 250 MCM

Pg.# Code Name 14 Prawn 23 Princeton 23 Purdue 7 Purpura N/A Quail 15 Quince 11 Rail 11 Ramapo 1 Ranella 5 Rapheal 6 Ravel 5 Raven 5 Razor 1 Redwing 13 Rider 15 Robin 14 Rockland 1 Rook 5 Rose 7 Rubens 5 Ruddy 13 Runcina 11 Rust 11 Rutgers 1 Sagebrush 6 Sandcrab 11 Sanddollar 11 Scallop 12 Schnauzer 5 Scoter 5 Setter 1 Sewanee 15 Shellbark 14 Shepherd N/A Shetland 7 Shrimp 2 Sipho 6 Slippery Rock 1 Snail 5 Snapdragon 11 Sneezewart 15 Soffit N/A Solaster 7 Spaniel N/A Sparate 1 Sparrow 14 Squab 22 Starling

Cond. Size 4 AWG 6 AWG 1/0 AWG 1/0 AWG 2/0 AWG 1/0 AWG 954 MCM 2 AWG 1/0 AWG 1/0 AWG 3/0 AWG 1/0 AWG 4/0 AWG 715.5 MCM 500 AWG 1 AWG 3/0 AWG 636 AWG 4 AWG 2/0 AWG 900 MCM 2/0 AWG 250 MCM 350 MCM 2250 MCM 1/0 AWG 3/0 AWG 4 AWG 2 AWG 636 MCM 6 AWG 750 MCM 3/0 AWG 6 AWG 1/0 AWG 2 AWG 2/0 AWG 350 MCM 1/0 AWG 900 MCM 250 MCM 1 AWG 2 AWG 4 AWG 2 AWG 2 AWG 605 MCM 715.5 MCM

1-833-895-9473



Pg.# Code Name 13 Stephens 21 Stilt 23 Strauss 14 Strombus 5 Suffolk 11 Swan 6 Swanate 22 Swarthmore 14 Sweetbriar N/A Swift N/A Syracuse 5 Syringa 14 Teal 6 Tern 22 Terrier 5 Thoroughbred 22 Thrasher 6 Trillium 1 Triton N/A Trotter 6 Tufts 14 Tulip 23 Tulsa 21 Turkey 2 Valerian 13 Vassar 14 Verbena 14 Violet 12 Vizsla 6 Voluta 12 Wake Forest 21 Walking N/A Walnut 12 Waxwing 16 Wesleyan 13 Whelk 13 Whippet 23 Windham 14 Wittenberg 2 Wofford 1 Wood Duck N/A Yale 13 Zinnia 12 Zuzara 5 5 6 6

Cond. Size 2 AWG 715.5 MCM 750 MCM 4 AWG 3/0 AWG 4 AWG 4 AWG 3/0 AWG 4/0 AWG 636 MCM 2/0 AWG 477 MCM 605 MCM 795 MCM 4 AWG 2/0 AWG 2312 MCM 3000 MCM 2/0 AWG 3/0 AWG 3/0 AWG 336.4 MCM 4 AWG 6 AWG 250 MCM 4 AWG 700 MCM 715.5 MCM 6 AWG 6 AWG 4/0 AWG 4/0 AWG 6 AWG 266.8 MCM 350 AWG 4 AWG 4 AWG 750 MCM 2 AWG 500 MCM 605 MCM 2/0 AWG 500 MCM 4/0 AWG

Pg. # 22 6 N/A 14 15 5 5 23 22 6 23 1 6 6 12 16 7 2 14 16 21 1 23 5 1 22 1 1 12 14 23 16 11 5 22 14 12 23 23 23 6 21 1 14

Table of Contents

Section I. Bare Aluminum Transmission & Distribution

AAC........................................................................................................................................................................ 1-2 AAAC......................................................................................................................................................................... 3 ACAR......................................................................................................................................................................... 4 ACSR...................................................................................................................................................................... 5-7 ACSR/AW............................................................................................................................................................... 8-9 ACSR/TP................................................................................................................................................................. 10 Aluminum Tie Wire................................................................................................................................................. 10

Section II. Aluminum 600 Volt Overhead

Covered Line Wire.................................................................................................................................................. 11 Duplex Service Drop............................................................................................................................................... 12 Triplex Service Drop..........................................................................................................................................13-14 Quadruplex Service Drop...................................................................................................................................15-16

Section III. Primary URD Cable 15KV-35KV

15 KV TR-XLPE URD..........................................................................................................................................17-18 25 KV TR-XLPE URD..........................................................................................................................................18-19 35 KV TR-XLPE URD..........................................................................................................................................19-20

Section IV. Aluminum 600 Volt URD

Single Conductor.................................................................................................................................................... 21 Duplex Conductor.................................................................................................................................................... 21 Triplex Conductor.................................................................................................................................................... 22 Quadruplex Conductor............................................................................................................................................ 23 8000 Series............................................................................................................................................................ 24

Section V. Control Cable

20/10 Control Cable................................................................................................................................................ 25 XLP/CPE Control Cable......................................................................................................................................26-27

Section VI. Specialty

Riser Wire (Solid and Stranded) / Jumper Cable / Clear Grounding Cable............................................................. 28 RHH/RHW-2/USE-2/(Copper and Aluminum).....................................................................................................29-31 Bare and Tinned Copper......................................................................................................................................... 32 Aluminum Clad Steel Wire...................................................................................................................................... 33 Ground Rods......................................................................................................................................................34-35 Ground Rod Accessories......................................................................................................................................... 36 Spacer Cable FR-NP..........................................................................................................................................37-39 Galvanized Guy Wire............................................................................................................................................... 40 Tap Wire.................................................................................................................................................................. 40 Generator Cable...................................................................................................................................................... 41 Tracer Wire........................................................................................................................................................42-43 XLPE/CPE Instrumentation Cable............................................................................................................................ 44 Shielded Tray Cable................................................................................................................................................ 45

Notes...................................................................................................................................................................... 46 Line Card................................................................................................................................................................ 47

AAC - All Aluminum Conductor

APPLICATION: Stranded 1350-H19 aluminum conductors are used for primary and secondary transmission and distribution. Class AA is for bare conductors used in overhead lines. Class A is for conductors to be covered with weather-resistant materials and for bare conductors where greater flexibility is required. Class is an indication of relative conductor flexibility, AA being the least flexible. SPECIFICATIONS: AAC bare conductors meet or exceed the following ASTM specifications: B-230 Aluminum 1350-H19 Wire for Electrical Purposes. B-231 Concentric-Lay-Stranded Aluminum 1350 Conductors.

Code Word

Conductor Size

Peachbell Rose Iris Pansy Poppy Aster Phlox Oxlip Sneezewar t Valerian Daisy Laurel Peony Tulip Daffodil Canna Goldentuft Cosmos Syringa Zinnia Hyacinth Dahlia Mistletoe Meadowsweet Orchid Heuchera Verbena Flag Violet

AWG/kcmil 6 4 2 1 1/0 2/0 3/0 4/0

250 250 266.8 266.8 300 336.4 350 397.5 450 477 477 500 500 556.5 556.5 600 636 650 700 700 715.5

(Continued on page 2)

Stranding

No. of Wires

Class

7

A

7

A

7

AA,A

7

AA,A

7

AA,A

7

AA,A

7

AA,A

7

AA,A

7

AA

19

A

7

AA

19

A

19

A

19

A

19

A

19

AA,A

19

AA

19

AA

37

A

19

AA

37

A

19

AA

37

AA,A

37

AA,A

37

AA,A

37

AA

37

AA

61

A

37

AA

Diameter Indiv. Comp. Strand Cable inches inches 0.0612 0.184 0.0772 0.232 0.0974 0.292 0.1093 0.328 0.1228 0.368 0.1379 0.414 0.1548 0.464 0.1739 0.522 0.1890 0.567 0.1147 0.574 0.1953 0.586 0.1185 0.593 0.1257 0.629 0.1331 0.666 0.1357 0.679 0.1447 0.724 0.1539 0.769 0.1584 0.793 0.1135 0.795 0.1622 0.811 0.1162 0.813 0.1711 0.856 0.1226 0.858 0.1273 0.891 0.1311 0.918 0.1326 0.928 0.1375 0.963 0.1071 0.964 0.1391 0.974

Cross Sectional

Area

Sq. In. 0.0206 0.0328 0.0522 0.0657 0.0829 0.1045 0.1318 0.1663 0.1964 0.1964 0.2095 0.2095 0.2358 0.2644 0.2749 0.3122 0.3534 0.3746 0.3746 0.3927 0.3924 0.4371 0.4371 0.4712 0.4995 0.5105 0.5498 0.5498 0.5623

Weight

lbs/kft 25 39 62 79 99 125 158 199 235 235 251 251 281 316 329 373 422 448 448 469 469 522 522 563 597 610 657 657 672

Rated Breaking Strength

lbs 563 881 1,350 1,640 1,990 2,510 3,040 3,830 4,520 4,660 4,830 4,970 5,480 6,150 6,390 7,110 7,890 8,360 8,690 8,760 9,110 9,750 9,940 10,700 11,400 11,600 12,500 12,900 12,800

Resistance**

DC @ 20?C

AC @ 75?C

Ohms/kft Ohms/kft

0.6580 0.8050

0.4140 0.5060

0.2600 0.3180

0.2070 0.2520

0.1640 0.2000

0.1300 0.1590

0.1030 0.1260

0.0817 0.0999

0.0691 0.0846

0.0691 0.0846

0.0648 0.0793

0.0648 0.0793

0.0578 0.0706

0.0514 0.0630

0.0494 0.0605

0.0435 0.0534

0.0384 0.0472

0.0362 0.0445

0.0362 0.0445

0.0346 0.0425

0.0346 0.0425

0.0311 0.0382

0.0311 0.0382

0.0288 0.0355

0.0272 0.0335

0.0266 0.0328

0.0247 0.0305

0.0247 0.0305

0.0242 0.0299

Ampacity*

amps 103 138 185 214 247 286 331 383 425 425 443 444 478 513 526 570 616 639 639 658 658 703 704 738 765 775 812 812 823

1-833-895-9473



1

CONTINUED

AAC - All Aluminum Conductor

Code Word

Nastur tium Petunia Cattail Arbutus Lilac Cockscomb Snapdragon Magnolia Goldenrod Hawkweed Camellia Bluebell Larkspur Marigold Hawthorn Narcissus Columbine Carnation Gladiolus Coreopsis Jessamine Cowslip Sagebrush Lupine Bitterroot Trillium Bluebonnet

Conductor Size

AWG/kcmil 715.5 750 750 795 795 900 900 954 954 1000 1000 1033.5 1033.5 1113 1192.5 1272 1351.5 1431 1510.5 1590 1750 2000 2250 2500 2750 3000 3500

Stranding

No. of Wires

61 37 61 37 61 37 61 37 61 37 61 37 61 61 61 61 61 61 61 61 61 91 91 91 91 127 127

Class

A AA A AA A AA A AA A AA A AA A AA,A AA,A AA,A AA,A AA,A AA,A AA AA A A A A A A

Diameter Indiv. Comp. Strand Cable inches inches 0.1083 0.975 0.1424 0.997 0.1109 0.998 0.1466 1.026 0.1142 1.028 0.1560 1.092 0.1215 1.094 0.1606 1.124 0.1251 1.126 0.1644 1.151 0.1280 1.152 0.1671 1.170 0.1302 1.172 0.1351 1.216 0.1398 1.258 0.1444 1.300 0.1489 1.340 0.1532 1.379 0.1574 1.417 0.1614 1.454 0.1694 1.525 0.1482 1.630 0.1572 1.729 0.1657 1.823 0.1739 1.913 0.1537 1.998 0.1660 2.158

Cross Sectional

Area

Sq. In. 0.5619 0.5893 0.5892 0.6245 0.6248 0.7072 0.7073 0.7495 0.7498 0.7854 0.7849 0.8114 0.8122 0.8744 0.9366 0.9990 1.0610 1.1244 1.1869 1.2490 1.3748 1.5710 1.7670 1.9640 2.1600 2.3564 2.7490

Weight

lbs/kft 672 705 704 746 746 845 845 896 896 939 939 970 970 1,045 1,119 1,194 1,269 1,343 1,418 1,493 1,643 1,877 2,131 2,370 2,607 2,844 3,350

Rated Breaking Strength

lbs 13,100 13,100 13,500 13,900 14,300 15,400 15,900 16,400 16,900 17,200 17,700 17,700 18,300 19,700 21,100 22,000 23,400 24,300 25,600 27,000 29,700 34,200 37,500 41,900 46,100 50,300 58,700

Resistance**

DC @ 20?C

AC @ 75?C

Ohms/kft Ohms/kft

0.0242 0.0299

0.0230 0.0286

0.0230 0.0286

0.0217 0.0271

0.0217 0.0270

0.0192 0.0239

0.0192 0.0239

0.0181 0.0226

0.0181 0.0226

0.0173 0.0216

0.0173 0.0216

0.0167 0.0210

0.0167 0.0210

0.0155 0.0195

0.0145 0.0183

0.0136 0.0173

0.0128 0.0163

0.0121 0.0155

0.0144 0.0147

0.0109 0.0141

0.0099 0.0129

0.0086 0.0115

0.0078 0.0105

0.0070 0.0097

0.0064 0.0090

0.0058 0.0083

0.0050 0.0076

Ampacity*

amps 823 847 847 878 879 948 948 982 983 1,010 1,011 1,031 1,032 1,079 1,124 1,169 1,212 1,253 1,294 1,333 1,408 1,518 1,612 1,706 1,793 1,874 2,024

All values are nominal and subject to correction * Current ratings are based on 75?C conductor temperature, 25?C ambient, 2ft/s wind, in sun, .05 coefficients of emissivity and absorption. ** Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS, AC resistance at 60 Hz.

1-833-895-9473



2

AAAC All Aluminum Alloy (6201) Conductor

APPLICATION: Bare overhead conductor used for primary and secondary transmission and distribution. Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; better sag characteristics. AAAC has higher resistance to corrosion than ACSR. CONSTRUCTION: Standard 6201-T81 high strength aluminum conductors, conforming to ASTM specification B399, are concentric-laystranded, similar in construction and appearance to 1350 grade aluminum conductors. Conductors of the 6201-T81 alloy have a greater resistance to abrasion than conductors of 1350-H19 grade aluminum. SPECIFICATIONS: AAAC bare conductor meets or exceeds the following ASTM specifications:

B-398 Aluminum Alloy 6201-T81 and 6201-T83 Wire for Electrical Purposes B-399 Concentric-Lay-Stranded Aluminum Alloy 6201-T81 Conductors

RUS ACCEPTED

Code Word

Akron Alton Ames Azusa Anaheim Amherst Alliance Butte Canton Cairo Darien Elgin Flint Greeley

Conductor Size

kcmil 30.58 48.69 77.47 123.3 155.4 195.7 246.9 312.8 394.5 465.4 559.5 652.4 740.8 927.2

No. of Wires

7 7 7 7 7 7 7 19 19 19 19 19 37 37

Equivalent ACSR

Size Stranding

AWG/kcmil 6 4 2 1/0 2/0 3/0 4/0

266.8 336.4 397.5 477.0 556.5 636.0 795.0

AL/Steel 6/1 6/1 6/1 6/1 6/1 6/1 6/1 26/7 26/7 26/7 26/7 26/7 26/7 26/7

Diameter

Indiv. Comp. Strand Cable inches inches 0.0661 0.1980 0.0834 0.2500 0.1052 0.3160 0.1327 0.3980 0.1490 0.4470 0.1672 0.5020 0.1878 0.5630 0.1283 0.6420 0.1441 0.7210 0.1565 0.7830 0.1716 0.8580 0.1853 0.9270 0.1414 0.9910 0.1583 1.1080

Cross Sectional

Area

Sq. In. 0.0240 0.0382 0.0608 0.0968 0.1221 0.1537 0.1939 0.2456 0.3098 0.3655 0.4394 0.5124 0.5818 0.7282

Weight

lbs/kft 29 45 72 115 145 183 230 292 368 434 522 608 691 865

Rated Breaking Strength

lbs 1,110 1,760 2,800 4,270 5,390 6,790 8,560 10,500 13,300 15,600 18,800 21,900 24,400 30,500

Resistance**

DC @ 20?C

AC @ 75?C

Ohms/kft Ohms/kft

0.6588 0.7850

0.4139 0.4930

0.2601 0.3100

0.1635 0.1950

0.1297 0.1540

0.1030 0.1230

0.0816 0.0973

0.0644 0.0769

0.0511 0.0610

0.0433 0.0518

0.0360 0.0420

0.0309 0.0371

0.0272 0.0327

0.0217 0.0263

Ampacity*

amps 107 143 191 256 296 342 395 460 532 590 663 729 790 908

All values are nominal and subject to correction * Current ratings are based on 75?C conductor temperature, 25?C ambient, 2ft/s wind, in sun, .05 coefficients of emissivity and absorption. ** Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 52.5% IACS, AC resistance at 60 Hz.

1-833-895-9473



3

ACAR - Aluminum Conductor Aluminum Reinforced

APPLICATION: Bare overhead conductor used as transmission cable and as primary and secondary distribution cable. A good strength-toweight ratio makes ACAR applicable where both ampacity and strength are prime considerations in line design; for equal weight, ACAR offers higher stength and ampacity than ACSR. CONSTRUCTION: Aluminum alloy 1350--H19 wires, concentricallly stranded around an aluminum alloy 6201 core. Although the alloy strands generally comprise the core of the cable, in some constructions they are distributed in layers throughout the aluminum alloy 1350-H19 strands. SPECIFICATIONS: ACAR bare conductor meets or exceeds the following ASTM specifications: B-230 Aluminum 1350-H19 Wire for Electrical Purposes B-398 Aluminum-Alloy 6201-T81 Wire for Electrical Purposes B-524 Concentric-Lay-Stranded Aluminum Conductors, Aluminum Alloy Reinforced (ACAR, 1350/6201)

Conductor Size

Stranding

kcmil 355.0 465.9 503.6 653.1 739.8 739.8 853.7 853.7 927.2 927.2 1024.5 1024.5 1081.0 1081.0 1109.0 1109.0 1172.0 1172.0 1197.0 1197.0 1280.0 1280.0 1361.0 1527.0 1703.0 1933.0 2267.0 2493.0 2493.0

1350/6201 12/7 12/7 12/7 12/7 30/7 18/19 30/7 18/19 30/7 18/19 30/7 18/19 30/7 18/19 30/7 18/19 30/7 18/19 30/7 18/19 30/7 18/19 42/19 42/19 42/19 42/19 42/19 72/19 54/37

Diameter (in)

Individual Strand 1350 6201

Comp. Cable

0.1367 0.1367 0.683

0.1566 0.1566 0.783

0.1628 0.1628 0.814

0.1854 0.1854 0.927

0.1414 0.1414 0.99

0.1414 0.1414 0.99

0.1519 0.1519 1.063

0.1519 0.1519 1.063

0.1583 0.1583 1.108

0.1583 0.1583 1.108

0.1664 0.1664 1.165

0.1664 0.1664 1.165

0.1709 0.1709 1.196

0.1709 0.1709 1.196

0.1731 0.1731 1.212

0.1731 0.1731 1.212

0.1780 0.1780 1.246

0.1780 0.1780 1.246

0.1799 0.1799 1.259

0.1799 0.1799 1.259

0.1860 0.1860 1.302

0.1860 0.1860 1.302

0.1494 0.1494 1.344

0.1582 0.1582 1.424

0.1671 0.1671 1.504

0.1780 0.1780 1.602

0.1928 0.1928 1.735

0.1655 0.1655 1.821

0.1655 0.1655 1.821

Weight

lbs/kft 332 436 471 611 693 692 799 798 868 867 959 958 1,012 1,011 1,038 1,037 1,097 1,096 1,121 1,119 1,199 1,197 1,274 1,429 1,594 1,809 2,142 2,357 2,355

Rated Strength

lbs 8,500 11,000 11,900 15,400 15,300 18,800 17,500 21,500 19,000 23,400 20,900 25,800 22,100 27,200 22,700 27,900 24,000 29,500 24,500 30,200 26,200 32,200 30,300 33,600 37,500 42,500 49,900 50,400 57,600

Resistance**

Allowable

DC @ 20?C AC @ 75?C Ampacity*

Ohms/kft Ohms/kft amps

0.0514

0.0624

519

0.0392

0.0477

616

0.0362

0.0441

646

0.0279

0.0342

760

0.0240

0.0296

831

0.0252

0.0308

814

0.0208

0.0257

907

0.0218

0.0268

890

0.0192

0.0238

955

0.0201

0.0247

936

0.0173

0.0216

1,015

0.0182

0.0225

995

0.0164

0.0205

1,048

0.0172

0.0213

1,028

0.0160

0.0200

1,065

0.0168

0.0208

1,044

0.0152

0.0190

1,101

0.0159

0.0198

1,080

0.0148

0.0187

1,115

0.0156

0.0194

1,094

0.0139

0.0175

1,160

0.0146

0.0182

1,139

0.0133

0.0168

1,196

0.0118

0.0151

1,314

0.0106

0.0137

1,363

0.00936 0.0123

1,465

0.00806 0.0108

1,594

0.00722 0.0099

1,687

0.00743 0.0101

1,670

All values are nominal and subject to correction

*Current ratings are based on 75?C conductor temperature, 25?C ambient temperature, with 2ft./sec. wind in the sun.

**DC resistance is based on electrical resistivity of 16.946 ohm.cmil/ft @ 20c (61.2% IACS) for 1350-H19 wires and 19.755 ohm.cmil/ft @ 20c (52.5%

IACS) for 6201 wires.

1-833-895-9473



4

................
................