Secondary URD Aluminum - CME Wire

Secondary URD Aluminum

XLPE Insulated, 600 V

Features

RUS accepted.

Single conductors are UL Listed as Type USE-2.

Excellent heat, ozone, oil and chemical resistance.

Resistant to tear and abrasion.

Suitable for direct burial.

AA-8000 Series aluminum alloy conductor where increased flexibility is required.

Application

Used for secondary distribution and underground service at 600 V or less.

May be used in ducts or direct burial.

Standards

ICEA S-105-692

600 V Single Layer Thermoset Insulated Utility Underground Distribution Cable.

UL 854

Service-Entrance Cables.

Specifications

Maximum operating voltage:

? 600 V Maximum conductor operation temperatures:

? 90 ?C wet and dry

Engineering Information

1. Conductor: Aluminum alloy 1350-H19, compressed Class B stranding, or unilay-compressed per ASTM B231.

On request, AA-8000 series aluminum alloy per ASTM B800 and B801 or copper conductors.

2. Separator: A suitable opaque tape, as required.

3. Insulation:

Phase conductor: Black thermoset cross-linked polyethylene (XLPE).

Neutral conductor: Black thermoset cross-linked polyethylene (XLPE), with three yellow extruded stripes.

1 2 3

Conductor Phase ID: Ink printed. Configurations: Single: One black phase insulated conductor. Duplex: One black phase insulated conductor and one neutral insulated conductor cabled together. Triplex: Two black phase insulated conductors (A & B) and one neutral insulated conductor cabled together. Quadruplex: Three black phase insulated conductors (A, B & C) and one neutral insulated conductor cabled together.

SINGLE DUPLEX TR I P L E X QUADRUPLEX

Secondary URD Cable ? Aluminum

CME Wire and Cable | 495 Horizon Drive NE, Suite 100, Suwanee, Georgia 30024 | | 770.623.0001

? 2014 CME Wire and Cable, Inc. All Rights Reserved.

September 22, 2020

Secondary URD Aluminum, XLPE Insulated, 600 V

Technical Data

Single

Code Word Princeton Mercer Clemson Kenyon Harvard Yale Tufts Beloit Hofstra Gonzaga Rutgers Dartmouth Brown Emory Duke Furman Sewanee Fordham

Size AWG or kcmil

6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 450 500 600 700 750 1000

Phase Conductor

Number of

Strands

Insulation Thickness

mil

7

60

7

60

7

60

19

80

19

80

19

80

19

80

19

80

37

95

37

95

37

95

37

95

37

95

37

95

61

110

61

110

61

110

61

110

Cable OD mil 0.31 0.35 0.41 0.49 0.53 0.57 0.62 0.68 0.76 0.81 0.86 0.91 0.95 0.99 1.10 1.17 1.20 1.35

The above data are approximate and subject to normal manufacturing tolerances. Other sizes available upon request. Ampacities: Refer to beginning of section.

XLPE Insulation

Code Word Suffix /XLP /XLP /XLP /XLP /XLP /XLP /XLP /XLP /XLP /XLP /XLP /XLP /XLP /XLP /XLP /XLP /XLP /XLP

Net Weight lb/kft 45 65 94 125 150 182 221 271 323 377 431 485 539 592 711 816 870 1129

Duplex

Code Word Alcorn Claflin Delgado Cedarcrest Everett Findlay Hanover Glenville

Size AWG or kcmil

8 6 4 2 2 2/0 4/0 350

Phase Conductor

Number of

Strands

Insulation Thickness

mils

1

60

7

60

7

60

7

60

7

60

19

80

19

80

37

95

Size AWG or kcmil

Neutral Conductor

Number of

Strands

Insulation Thickness

mil

8

1

60

6

7

60

4

7

60

4

7

60

2

7

60

2/0

19

80

4/0

19

80

350

37

95

The above data are approximate and subject to normal manufacturing tolerances. Other sizes available upon request. Ampacities: Refer to beginning of section.

Cable OD

Single Phase

in

Complete Cable in

0.25

0.50

0.31

0.61

0.35

0.70

0.41

0.82

0.41

0.82

0.57

1.15

0.68

1.36

0.86

1.72

XLPE Insulation

Code Word Suffix

Net Weight lb/kft

/XLP/EYS

62.2

/XLP/EYS

92.8

/XLP/EYS

131.7

/XLP/EYS

161.4

/XLP/EYS

191.2

/XLP/EYS

372.0

/XLP/EYS

552.1

/XLP/EYS

880.2

September 22, 2020

CME Wire and Cable | 495 Horizon Drive NE, Suite 100, Suwanee, Georgia 30024 | | 770.623.0001

? 2014 CME Wire and Cable, Inc. All Rights Reserved.

Secondary URD Aluminum, XLPE Insulated, 600 V

Technical Data continued

Triplex

Code Word

Erskine

Size AWG or kcmil

6

Phase Conductor

Number of

Strands

Insulation Thickness

mil

7

60

Neutral Conductor

Size AWG or kcmil

Number of

Strands

Insulation Thickness

mil

6

7

60

Vassar

4

7

60

4

7

60

Stephens

2

7

60

4

7

60

Ramapo

2

7

60

2

7

60

Grossmont

1

19

80

1

19

80

Brenau

1/0

19

80

2

7

60

Bergen

1/0

19

80

1/0

19

80

Fisk Converse

2/0

19

80

2/0

19

80

2

7

60

1

19

80

Shaw Hunter

2/0

19

80

1/0

19

80

2/0

19

80

2/0

19

80

Calvert Chase

3/0

19

80

3/0

19

80

2

7

60

1

19

80

Hollins Rockland

3/0

19

80

1/0

19

80

3/0

19

80

3/0

19

80

Coburn

4/0

19

80

1

19

80

Molloy

4/0

19

80

1/0

19

80

Sweetbriar

4/0

19

80

2/0

19

80

Monmouth

4/0

19

80

4/0

19

80

Aquinas

250

37

95

2/0

19

80

Pratt

250

37

95

3/0

19

80

Yeshiva Allen

250

37

95

250

37

95

300

37

95

2/0

19

80

Greenville Gloucester

350

37

95

1/0

19

80

350

37

95

3/0

19

80

Wesleyan Newark

350

37

95

4/0

19

80

350

37

95

350

37

95

Old Dominion Holyoke

500

37

95

4/0

19

80

500

37

95

300

37

95

Rider

500

37

95

350

37

95

Westchester

500

37

95

500

37

95

Villanova

750

61

110

350

37

95

Voorhees

750

61

110

450

37

95

Fairfield

750

61

110

500

37

95

Seton Hall

750

61

110

750

61

110

The above data are approximate and subject to normal manufacturing tolerances. Other sizes available upon request. Ampacities: Refer to beginning of section.

Cable OD

Single Phase

in

Complete Cable in

0.31

0.66

0.35

0.76

0.41

0.88

0.41

0.88

0.49

1.06

0.53

1.14

0.53

1.14

0.57

1.24

0.57

1.24

0.57

1.24

0.57

1.24

0.62

1.34

0.62

1.34

0.62

1.34

0.62

1.34

0.68

1.47

0.68

1.47

0.68

1.47

0.68

1.47

0.76

1.63

0.76

1.63

0.76

1.63

0.81

1.75

0.86

1.85

0.86

1.85

0.86

1.85

0.86

1.85

0.99

2.13

0.99

2.13

0.99

2.13

0.99

2.13

1.20

2.58

1.20

2.58

1.20

2.58

1.20

2.58

XLPE Insulation

Code Word Suffix

Net Weight lb/kft

/XLP/EYS

139

/XLP/EYS

198

/XLP/EYS

257

/XLP/EYS

287

/XLP/EYS

383

/XLP/EYS

402

/XLP/EYS

460

/XLP/EYS

468

/XLP/EYS

500

/XLP/EYS

525

/XLP/EYS

558

/XLP/EYS

547

/XLP/EYS

579

/XLP/EYS

605

/XLP/EYS

677

/XLP/EYS

680

/XLP/EYS

705

/XLP/EYS

738

/XLP/EYS

828

/XLP/EYS

844

/XLP/EYS

884

/XLP/EYS

987

/XLP/EYS

956

/XLP/EYS

1034

/XLP/EYS

1106

/XLP/EYS

1156

/XLP/EYS

1320

/XLP/EYS

1483

/XLP/EYS

1592

/XLP/EYS

1647

/XLP/EYS

1811

/XLP/EYS

2215

/XLP/EYS

2324

/XLP/EYS

2379

/XLP/EYS

2662

CME Wire and Cable | 495 Horizon Drive NE, Suite 100, Suwanee, Georgia 30024 | | 770.623.0001

? 2014 CME Wire and Cable, Inc. All Rights Reserved.

September 22, 2020

Secondary URD Aluminum, XLPE Insulated, 600 V

Technical Data continued

Quadruplex

Code Word

Size AWG or kcmil

Phase Conductor

Number of

Strands

Insulation Thickness

mil

Size AWG or kcmil

Neutral Conductor

Number of

Strands

Insulation Thickness

mil

Tulsa

4

7

60

4

7

60

Miami

2

7

60

6

7

60

Dyke

2

7

60

4

7

60

Wittenberg

2

7

60

2

7

60

Notre Dame

1/0

19

80

2

7

60

Purdue

1/0

19

80

1/0

19

80

Syracuse

2/0

19

80

1

19

80

Lafayette

2/0

19

80

2/0

19

80

Swarthmore

3/0

19

80

1/0

19

80

Davidson

3/0

19

80

3/0

19

80

Mc Pherson

4/0

19

80

2

7

60

Doane

4/0

19

80

1/0

19

80

Wake Forest

4/0

19

80

2/0

19

80

Earlham

4/0

19

80

4/0

19

80

Rust

250

37

95

3/0

19

80

Palomar

250

37

95

250

37

95

Slippery Rock

350

37

95

4/0

19

80

Niagara

350

37

95

350

37

95

Morehouse

500

37

95

300

37

95

Wofford

500

37

95

350

37

95

Marshall

500

37

95

500

37

95

Westminster

750

61

110

350

37

95

Windham

750

61

110

500

37

95

Tabor

750

61

110

750

61

110

The above data are approximate and subject to normal manufacturing tolerances. Other sizes available upon request. Ampacities: Refer to beginning of section.

Cable OD

Single Phase

in

Complete Cable in

0.35

0.85

0.41

0.99

0.41

0.99

0.41

0.99

0.53

1.28

0.53

1.28

0.57

1.39

0.57

1.39

0.62

1.51

0.62

1.51

0.68

1.64

0.68

1.64

0.68

1.64

0.68

1.64

0.76

1.83

0.76

1.83

0.86

2.08

0.86

2.08

0.99

2.39

0.99

2.39

0.99

2.39

1.20

2.89

1.20

2.89

1.20

2.89

XLPE Insulation

Code Word Suffix

Net Weight lb/kft

/XLP/EYS

263

/XLP/EYS

333

/XLP/EYS

353

/XLP/EYS

382

/XLP/EYS

556

/XLP/EYS

614

/XLP/EYS

686

/XLP/EYS

744

/XLP/EYS

831

/XLP/EYS

903

/XLP/EYS

924

/XLP/EYS

981

/XLP/EYS

1014

/XLP/EYS

1104

/XLP/EYS

1213

/XLP/EYS

1316

/XLP/EYS

1596

/XLP/EYS

1760

/XLP/EYS

2196

/XLP/EYS

2251

/XLP/EYS

2415

/XLP/EYS

3102

/XLP/EYS

3266

/XLP/EYS

3550

September 22, 2020

CME Wire and Cable | 495 Horizon Drive NE, Suite 100, Suwanee, Georgia 30024 | | 770.623.0001

? 2014 CME Wire and Cable, Inc. All Rights Reserved.

................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download