General Services Administration



Project Title: Click here to enter text.Location: Click here to enter text.Current Phase: Choose an item.Date: Click here to enter a date.Project Manager: Click here to enter text. 2018 P100 Performance MatrixPlace an X for each requirementAttributeBaselineTier 1Tier2Tier 3N/ANotes (Describe how design meets performance or any waivers from a requirement)1.7.2 Sustainable Performance RequirementsEnergyEnergy Net ZeroWaterWater Net ZeroHigh Performance Building TechnologiesGSA Proving GroundConstruction PersonnelGreen Credentialed2.1 Urban Planning and Public Use Performance Requirements2.2.1 Sustainable LocationsSite Supports Neighborhood Connectivity, Walkability, and Transportation AccessSite Uses Existing Local Infrastructure Resources and Preserves Natural Resources2.2.2 Collaborative Design ProcessDesign Process Considers Input of Local Officials2.2.3 Design for Public UseInteriorExterior2.4 Landscape Performance Requirements2.4 LandscapeSite SoilsVegetationWater Use and ManagementStormwater ManagementSite MaterialsPollinators3.1 Enclosure Performance Requirements3.2.1 Envelope – Natural HazardSeismic ResistanceWindborne Debris ResistanceFlood Resistance3.2.2 Envelope – ServiceabilityWind Resistance3.2.3 Water Penetration ResistanceFenestrationRoofing and Horizontal Waterproofing-Membrane SystemRoofing and Horizontal Waterproofing-Minimum SlopeRoofing and Horizontal Waterproofing- DrainageRoofing and Horizontal Waterproofing-Vegetative SystemsRoofing and Horizontal Waterproofing-Testing & MonitoringGround Water ControlBelow Grade Waterproofing3.2.4 Moisture and Condensation ControlMoisture Control Opaque AssembliesCondensation Resistance Fenestration3.2.5 Air TightnessFenestrationEnclosure Airtightness3.2.6 Thermal PerformanceThermal Performance3.2.7 Building Enclosure CommissioningBuilding Enclosure Commissioning3.2.8 Enclosure Acoustic ControlAcoustic Control Assuming NC-35 interior3.2.9 Enclosure Service LifeWallsRoofsFenestration3.4 Interior Performance Requirements3.5.1.1 Solid Core Wood DoorsConstructionLPOEDurabilityAcousticsHardwareFrameSecurity3.5.1.2 Hollow Metal DoorsConstructionDurabilityAcousticsHardwareFrameSecurity3.5.1.3 Glazed Aluminum DoorsConstructionDurabilityHardwareGlazingSecurity3.5.1.4 All Glass EntrancesConstructionGlazingHardwareDurabilitySecurity3.5.1.5 Borrowed LightsGlazing3.5.1.6 Wood Framed Interior LightsConstructionGlazing3.5.1.7 Hollow Metal Framed Interior LightsConstructionFrameGlazing3.5.1.8 Aluminum Framed Interior LightsConstructionFrameGlazing3.5.1.9 Metal Stud PartitionsConstructionLPOEDurabilityLPOEHeightLPOEAcousticsLPOESecurityLPOE3.5.1.10 Masonry PartitionsConstructionLPOEDurabilityLPOEAcousticsLPOESecurityLPOE3.5.1.11 Demountable PartitionsConstructionAcoustics3.5.1.12 Operable WallsConstructionAcousticsOperation3.5.1.13 Millwork and CabinetsConstructionDurabilityQuality3.5.1.14 CountertopsConstructionLPOEDurabilityLPOEQualityLPOE3.4 Interior Performance Requirements (cont.)3.5.2.1 Broadloom/Carpet TileDurabilityService LifeEnvironmental3.5.2.2 Vinyl Composition TileDurabilityMaintenanceService LifeEnvironmental3.5.2.3 Sheet VinylDurabilityMaintenanceService LifeEnvironmental3.5.2.4 Rubber TileDurabilityMaintenanceService LifeEnvironmental3.5.2.5 LinoleumDurabilityMaintenanceService LifeEnvironmental3.5.2.6 Pressed Floor TileDurabilityMaintenanceService LifeEnvironmental3.5.2.7 Porcelain TileDurabilityMaintenanceService LifeEnvironmental3.5.2.8 Quarry TileDurabilityMaintenanceService LifeEnvironmental3.5.2.9 Mosaic TileDurabilityMaintenanceService LifeEnvironmental3.5.2.10 Limestone TileDurabilityMaintenance3.5.2.11 Slate TileDurabilityMaintenance3.5.2.12 MarbleDurabilityMaintenance3.5.2.13 GraniteDurabilityMaintenance3.5.2.14 TerrazzoDurabilityMaintenanceEnvironmental3.5.2.15 Laminate FlooringDurabilityMaintenanceService LifeEnvironmental3.5.2.16 Wood FlooringDurabilityMaintenanceEnvironmental3.5.2.17 Bamboo FlooringDurabilityMaintenanceEnvironmental3.5.2.18 Glazed Wall TileDurabilityMaintenanceService LifeEnvironmental3.5.2.19 Interior Architectural CoatingsDurabilityEnvironmental – Flat, Nonflat, and Nonflat High Gloss CoatingsEnvironmental – All other architectural coatings3.5.2.20 Exterior Architectural CoatingsDurability – BlisteringDurability – ErosionDurability – Flacking/PeelingDurability – Biologic GrowthEnvironmental3.5.2.21 Wall Covering – Type IIDurabilityMaintenanceEnvironmental3.5.2.22 Wall Paneling Plastic/LaminateDurabilityMaintenanceService LifeEnvironmental3.5.2.23 Wall Paneling/WoodDurabilityMaintenanceEnvironmental3.5.2.24 Wall Paneling/Composite BoardDurabilityMaintenanceEnvironmental3.5.2.25 Wall Paneling/Sculptural PanelDurabilityMaintenanceEnvironmental3.5.2.26 Wall BaseDurabilityMaintenanceService LifeEnvironmental3.5.2.27 Acoustical Ceilings Acoustics Open Office – NRCAcoustics Open Office – CACAcoustics Open Office – Privacy IndexAcoustics Open Office – Sound MaskingAcoustics Open Office – Reverberation TimeAcoustics Enclosed Office - NRCAcoustics Enclosed Office – CACAcoustics Enclosed Office – Privacy IndexAcoustics Enclosed Office – Sound MaskingAcoustics Enclosed Office – Reverberation TimeDurability – Impact ResistanceDurability – Scratch ResistanceDurability – Moisture ResistanceMaintenanceService LifeEnvironmental – Recycled ContentEnvironmental – RecyclableEnvironmental – BioPreferredEnvironmental – Light ReflectanceEnvironmental – Low EmittingEnvironmental – EPDEnvironmental – Ingredient Disclosure3.7 Workplace Performance Requirements3.8.1 Planning and DesignGoal SettingPlanning & Design ProcessRequirements DevelopmentBalance of All Design Factors3.8.2 Space EfficiencyRight-SizingWorkstation and Office Sharing3.8.3 TechnologyNetwork AccessPhone3.8.4 Health and Confort: Environmental ControlsVentilation and Thermal ComfortLighting/DaylightingAcoustic Comfort3.8.5 Health and Comfort: ErgonomicsAdjustabilityBuilding Amenities3.8.6 Flexibility/EfficiencySpace UtilizationPartitions and Interior WallsAlternative Working Environments/Methods of WorkingPromote Equitable Resources, Amenities, and Alternative Ways of Working3.8.7 ImageWork place ImageWayfinding4.1 Structural Performance Requirements4.2.1 Live LoadVibrations4.2.2 Natural HazardWindSeismic – StructureSeismic – NonstructuralFlood Mitigation4.4 Physical Security Performance RequirementsPhysical Security PerformanceLPOE5.1 Mechanical Performance Requirements5.2.1 TemperaturePerformance5.2.2 Humidity ControlPerformance5.2.3 Air MovementPerformance5.2.4 PressurePerformance5.2.5 VentilationPerformance5.2.6 FiltrationPerformance5.2.7 HVAC Noise ControlPerformance5.2.8 HVAC Operational EfficiencyEquipment PerformanceFan Energy PerformanceBuilding HVAC Energy PerformanceHVAC Energy Metering6.1 Lighting Performance Requirements6.2.1 Lighting Quality – InteriorLuminance BalanceSpectral DistributionCCTCRILighting layersAmbientPersonalizedUser Acceptance6.2.1 Lighting Quality – ExteriorCCTCRILPOEEnvironmentalUser AcceptanceLight Pollution/Light Trespass6.2.2 Lighting Quantity - InteriorIlluminance – HorizontalIlluminance – VerticalSurface ReflectanceOperational Efficiency – AmbientOperational Efficiency – PersonalizedDaylight Autonomy6.2.2 Lighting Quantity – ExteriorIlluminance – HorizontalIlluminance – Vertical6.2.3 Lighting Energy Use – InteriorSystem EfficiencyControlsReal Time Energy Use6.2.3 Lighting Energy Use – ExteriorLighting Power DensityControlsReal Time Energy Use6.2.4 Power QualityPower Factor (Full Light Output)Power Factor (Fully Dimmed)Total Harmonic Distortion at the LED Driver (Full Light Output)Total Harmonic Distortion at the LED Driver (Fully Dimmed)Wiring6.2.5 MaintenanceEquipment LifeAccessibilityDiagnostics6.2.6 Service LifeReplacementRetrofit6.4 Electrical Performance Requirements6.4.3 TransformersEfficiencies for Network TransformersInsulating FluidEfficiencies for Low-Voltage DistributionImpedance for Low-Voltage DistributionHarmonic Rated6.4.2 Variable Frequency Drives5hp Motors30hp Motors125hp Motors6.4.3 Metering/Monitoring TrendingBuilding MainsFeedersTrending6.4.4 Building Automation SystemElectrical Meter InputPV System InputAutomatic Transfer Switches InputStandby Generator InputUninterruptible Power Systems InputVariable Frequency Drives InputMotor Starters InputAdditional Computer-Based BAS Interface Additional Computer-Based BAS Energy Management 6.4.5 Interior Electrical DistributionEnergy Saving Controls6.4.6 Arc- Flash ReductionARMS6.4.7 Power Factor CorrectionPower Factor6.4.8 Surge Protection Devices277/480 Volt distribution at Main Switchgear277/480V Volt distribution at Distribution Panels277/480V Volt Branch Panels120/208V Volt Branch Panels6.4.9 Lightning Protection SystemsUL ComplianceUL Master LabelLPOESurge Protection6.4.10 GroundingEarth CounterpoiseSeparate Grounding SystemEquipment Grounding Conductors6.4.11 Uninterruptible Power SystemsEfficiencyPower Factor – OutputPower Factor - InputInput Harmonics ................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download