3-Phase Rectifier
Wiring Instructions
Model: SQL90A
Date: 05/2018
Page: 1 of 2
3-Phase Rectifier
Wiring Instructions
Single PMA/PMG or Turbine Wiring:
Single PMA/PMG or Turbine Wiring:
3-Phase
Wind
Turbine
3-Phase
Wind
Turbine
(not
included)
3-phase
AC in
AC/DC
Rectifier
DC out
Battery Bank
(not included)
? CAUTION HIGH VOLTAGE! ?
Do not touch rectifier when in
operation. Mount rectifier on metal
surface away from children and pets.
Use 12 gauge 3 conductor (12/3) or
larger fine stranded power cable from
turbine to rectifier. All three will be
¡°hot¡±. Arrangement does not matter.
DO NOT let bare wires touch!
(not
included)
3-phase
AC in
AC/DC
Rectifier
Fuse or breaker.
Use 4 gauge or larger fine strand
power cable for DC side (4.11 mm2).
DO NOT connect backwards!
DC out
Battery Bank
(not included)
Model: SQL90A
Date: 05/2018
Page: 1 of 2
? CAUTION HIGH VOLTAGE! ?
Do not touch rectifier when in
operation. Mount rectifier on metal
surface away from children and pets.
Use 12 gauge 3 conductor (12/3) or
larger fine stranded power cable from
turbine to rectifier. All three will be
¡°hot¡±. Arrangement does not matter.
DO NOT let bare wires touch!
Fuse or breaker.
Use 4 gauge or larger fine strand
power cable for DC side (4.11 mm2).
DO NOT connect backwards!
When using a charge controller follow its wiring diagram from
turbine(s) to batteries. Mount rectifier near batteries (but out of
reach of children) to keep DC wires short as possible. TIP: You can
use some of your extra 12/3 cord to make a positive and negative
DC cord. Twist ends together.
When using a charge controller follow its wiring diagram from
turbine(s) to batteries. Mount rectifier near batteries (but out of
reach of children) to keep DC wires short as possible. TIP: You can
use some of your extra 12/3 cord to make a positive and negative
DC cord. Twist ends together.
Dual PMA/PMG or Multiple Wind Turbine Parallel Wiring:
Dual PMA/PMG or Multiple Wind Turbine Parallel Wiring:
3-Phase
Wind
Turbine
3-Phase
Wind
Turbine
3-Phase
Wind
Turbine
3-Phase
Wind
Turbine
3-phase
AC in
3-phase
AC in
3-phase
AC in
3-phase
AC in
(not
included)
AC/DC
Rectifier
(not
included)
AC/DC
Rectifier
(not
included)
Note: Inspect rectifier
for actual ¨C and +
symbols location.
There could be a
variance from picture!
AC/DC
Rectifier
DC out
Battery Bank
(not included)
(not
included)
AC/DC
Rectifier
Note: Inspect rectifier
for actual ¨C and +
symbols location.
There could be a
variance from picture!
DC out
Battery Bank
Fuse or breaker.
(not included)
Fuse or breaker.
Each dual PMA must have two 12/3 power cords. You cannot
combine a dual PMA or multiple wind turbines on the same
12/3 cable or rectifier AC side. You can combine several rectifiers
on the DC side. Voltage output stays the same in parallel but with
more amps. You need to double up wire or wire size on DC side
when in parallel.
Each dual PMA must have two 12/3 power cords. You cannot
combine a dual PMA or multiple wind turbines on the same
12/3 cable or rectifier AC side. You can combine several rectifiers
on the DC side. Voltage output stays the same in parallel but with
more amps. You need to double up wire or wire size on DC side
when in parallel.
A wind turbine can produce much higher voltage than your
battery voltage and this is how it charges them. The rectifier
does NOT voltage regulate the output. You must use some sort
of charge controller.
A wind turbine can produce much higher voltage than your
battery voltage and this is how it charges them. The rectifier
does NOT voltage regulate the output. You must use some sort
of charge controller.
Warning: If you reverse the positive and negative
connections from rectifier to controller or batteries the wind
turbine will burn up. Double check the + and ¨C marks on your
rectifiers before connections are made.
?
?
332 Cobble Stone Drive, Seymour, MO 65746
? (417) 708¨C5359
Warning: If you reverse the positive and negative
connections from rectifier to controller or batteries the wind
turbine will burn up. Double check the + and ¨C marks on your
rectifiers before connections are made.
332 Cobble Stone Drive, Seymour, MO 65746
? (417) 708¨C5359
3-Phase Rectifier
Wiring Instructions
Model: SQL90A
Date: 05/2018
Page: 2 of 2
3-Phase Rectifier
Wiring Instructions
Model: SQL90A
Date: 05/2018
Page: 2 of 2
INSTRUCTIONS: Using a Freedom I or Freedm II 12V PMG only
(PMA or PMG) on a direct, pulleyed, or gear driven; electric
motor, combustion motor, or hydroelectric system other than on
a wind turbine where air is not naturally forced through the PMA.
INSTRUCTIONS: Using a Freedom I or Freedm II 12V PMG only
(PMA or PMG) on a direct, pulleyed, or gear driven; electric
motor, combustion motor, or hydroelectric system other than on
a wind turbine where air is not naturally forced through the PMA.
Belt-driven/hydro fuse sizing:
Belt-driven/hydro fuse sizing:
Battery Voltage
Freedom I
Freedom II
Battery Voltage
Freedom I
Freedom II
12V
80 amps
100 amps
12V
80 amps
100 amps
24V
60 amps
80 amps
24V
60 amps
80 amps
48V
30 amps
40 amps
48V
30 amps
40 amps
A fan is important to help force air through the PMA to keep it
cool. On its first run make sure to adjust your RPMs if your PMA
becomes too hot within several minutes.
A fan is important to help force air through the PMA to keep it
cool. On its first run make sure to adjust your RPMs if your PMA
becomes too hot within several minutes.
If you live near salt water or in a very dusty or severe climate, use
our Permanent Magnet Alternator Wind Turbine PMA Coating for
extra protection on the PMA.
If you live near salt water or in a very dusty or severe climate, use
our Permanent Magnet Alternator Wind Turbine PMA Coating for
extra protection on the PMA.
?
HEAT WARNINGS: Notched v-belts run cooler and do not slip
as much as a traditional belt. A slipping belt can cause bearing
stress and heat buildup in the PMA. Proper v-belt installation is
very important. Insure that your v-belt pulleys are properly lined
up with a straight edge and that they are not worn and cutting
into the v-belt.
?
Proper v-belt tension should be set with a v-belt tension tool and
reset again after the first week to 10 days of operation to allow
for stretching in the v-belt. Most of the stretching takes place in
the first hours of operation so it is very important to recheck belt
tension after the belt has had some run time.
Proper v-belt tension should be set with a v-belt tension tool and
reset again after the first week to 10 days of operation to allow
for stretching in the v-belt. Most of the stretching takes place in
the first hours of operation so it is very important to recheck belt
tension after the belt has had some run time.
You MUST turn the PMA or PMG at these RPMs for proper
cooling fan operation (this does not mean that at these RPM's
you will get the watts listed):
You MUST turn the PMA or PMG at these RPMs for proper
cooling fan operation (this does not mean that at these RPM's
you will get the watts listed):
Watts
RPM+
HEAT WARNINGS: Notched v-belts run cooler and do not slip
as much as a traditional belt. A slipping belt can cause bearing
stress and heat buildup in the PMA. Proper v-belt installation is
very important. Insure that your v-belt pulleys are properly lined
up with a straight edge and that they are not worn and cutting
into the v-belt.
Watts
RPM+
0 to 300 watts
0 to 300 RPM+
0 to 300 watts
0 to 300 RPM+
300 to 800 watts
1400 RPM+
300 to 800 watts
1400 RPM+
800 to 1500 watts
2500 RPM+
800 to 1500 watts
2500 RPM+
1500 to 2500 watts
3700 RPM+
1500 to 2500 watts
3700 RPM+
If you are pulling over 500 watts without a cooling fan, your
PMA may overheat. Monitor your PMA for excessing heating in
all experimental machinery. Max PMA operating temperature is
300¡ãF for 100% duty cycle.
If you are pulling over 500 watts without a cooling fan, your
PMA may overheat. Monitor your PMA for excessing heating in
all experimental machinery. Max PMA operating temperature is
300¡ãF for 100% duty cycle.
Do not coat the outside of the PMA under any circumstances as
this prevents cooling.
Do not coat the outside of the PMA under any circumstances as
this prevents cooling.
No warranties on any burned out PMAs. Keeping your PMAs
cooled, fused and under reasonable loads is the operator¡¯s full
responsibility.
No warranties on any burned out PMAs. Keeping your PMAs
cooled, fused and under reasonable loads is the operator¡¯s full
responsibility.
Formulas: volts X amps = watts
battery volts X amps = watts
For example: 29.1 volts X 10 amps = 291 watts
Formulas: volts X amps = watts
battery volts X amps = watts
For example: 29.1 volts X 10 amps = 291 watts
332 Cobble Stone Drive, Seymour, MO 65746
? (417) 708¨C5359
332 Cobble Stone Drive, Seymour, MO 65746
? (417) 708¨C5359
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related searches
- 3 phase single phase wiring
- 208 3 phase vs 230 3 phase
- single phase 208 vs 3 phase 208
- single phase to 3 phase inverter
- 1 phase to 3 phase inverter
- 3 phase to 1 phase converter
- 1 phase 3 phase converter
- 3 phase power vs 1 phase power
- 1 phase to 3 phase transformer
- remington model 11 date chart
- single phase to 3 phase converters
- 3 phase vs single phase power