WIMES 3.04, Issue 4, January 2011



APPENDIX C1 - DATA SHEETSPACKAGE PLANT (ELECTRICAL)PROJECT TITLE (P)DOCUMENT REFERENCE (P)PROJECT NUMBER (P)REVISION (P)PROJECT LOCATION (P)DATE (P)PACKAGE PLANT SUPPLIER (P/S)REFERENCE DRAWINGS INCLUDED (Y/N) (P) * - indicates Purchaser’s default requirement3.0 OPERATING ENVIRONMENT AND SERVICE CONDITIONS1Operating Environment (P)Site Location ()InlandCoastalPackage Plant Location ()IndoorsOutdoorsOther (specify)Hazardous Area Classification ()Non hazardousZone 1Zone 2EMC Environment ()1st environment – C11st environment – C22nd environment – C33Special Service Conditions (P)4.0 ELECTRICAL SYSTEM CHARACTERITICS1Electrical System Characteristics (P)aSupply Arrangement ()Single sourceMultiple source (specify sources and operating arrangement elsewhere)bSupply Voltage, Frequency and Number of Phases ()400 V, 3 phase, 50 Hz3 wire4 wireOther (specify)4.0 ELECTRICAL SYSTEM CHARACTERITICS (CONTD.)cProspective Fault Current (kA) (max)Phase to phasePhase to neutralPhase to earthdType of Earthing System ()TN-STN-C-S (PME)TTOther (specify)eEarth Fault Loop Impedance (Ohms)ZefType and Rating of the Upstream Protective Device ()NoneCircuit breakerFuseNumber of polesBSTypeOvercurrent rating (A)Earth fault rating (A)Earth fault time delay (secs)Other arrangement (specify)gSupply Cable CharacteristicsBSTypeCopper conductorsRating (A)Phase CSA (mm2)Neutral CSA (mm2)Earth CSA (mm2)2Overvoltage Category (III*) (P)3Assumed Voltage Drop for Package Plant (V) (P)4Supply Restrictions (P)6Lightning and Surge Protection Requirements (P)5.0 PERFORMANCE SPECIFICATION3Minimum Design Life (20?years*) (P)6.0 DESIGN SPECIFICATION6.1 General6.1.1 General and Safety Requirements3Method of Fault Protection (ADS*) (P/S)6.1.6 O & M Manuals1Reference for O & M Manual Specification ([P)6.2 The Assembly6.2.1 General2Form of Internal Separation (P/S)Form 2 assemblies (2a or 2b)Form 4 assemblies (4a or 4b)5Control Circuit Test Facilities () (S)Internal push-buttonTest position on switching and isolation device7Diversity factor (S)6.2.2 Electrical Components4Component (P)Details (S)6.2.4 Construction6.2.4.1 General3Material(s) of Construction (Including Details of Any Protective Coatings) (P/S)4Type of Assembly Construction () (P/S)aCubicle/multi-cubiclebBox/multi-box6Degree of Ingress Protection (IP Code) (P/S)7Size/Weight Restrictions (P)6.2.4.5 Mounting Arrangements1Mounting Arrangements () (P/S)Skid/frame mountedWall mountedOther (specify)6.2.5 Earthing and Bonding4Separate Earth Bars/ Studs Required (Y/N) (P)6.2.6 Cabling and Wiring6.2.6.1 General3Ratio of CSAs of Neutral and Line Conductors (100?%*) (P)6.2.7 Requirements for Specific Components6.2.7.1 Indicating Lamps2Lamp Colours/Meanings (P)Available/auto-availablewhiteSupply onRunningStoppedEmergency stopDangerous conditionredNormal conditionAlarmyellow/ amberTripped/faultyellow/ amberOnOffProcess indicators6.2.7.2 Push-Button and Control Switches1Push Button Switch Colours/Meanings (P)StartStopResetEmergency stopredInchLamp testClosedOpenOnOff6.2.8 Functional Units1Method of Functional Unit Connection (P)6.2.8.1 Incomer1Fuse Switch Rating & Configuration (S)Rating (A) 3 pole3 pole + bolted neutral link4 poleShort circuit capacity (kA)6.2.8.2 Motor StartersRefer to APPENDIX C26.2.8.3 Control Circuit Supplies3CCS Voltage (P/S)6.2.8.4 ICA EquipmentGeneral10Type of HMI Required/Provided (P/S)11Method of Connecting Package Plant to Site Control System () (P)HardwiredRemote I/O unitFieldbus connection11Reference for Purchaser’s Particular SpecificationLow Voltage and Extra Low Voltage Systems1Type and Configuration of LV and ELV Systems (P/S)Lighting and Socket Outlets1Lighting Facilities Required (Y/N) (P)PLC1PLC Provided (Y/N) (S)6.2.8.5 Uninterruptible Power Supply (UPS)1UPS Requirements () (P)None required Provided within AssemblyProvided within a separate assembly3Details of Loads to be Supported by the UPS (P)4UPS Rating and Autonomy Time (110% and 15 minutes (min)) (P)6.2.8.6 Supervisory Control and Monitoring2Local & Remote Supervisory Control Signals Required/ Provided (P/S)Signal DescriptionSignal Type11 – Volt-free (VF), Digital?(D), Analogue (A)3Local & Remote Supervisory Monitoring Signals Required/Provided (P/S)Signal DescriptionType1I/C21 – Volt-free (VF), Communications link (CL), Analogue (A)2 – Individual (I), common (C)6.2.10 Additional Requirements for Form 2 Assemblies6.2.10.1 ConstructionGeneral3Distribution Board Location (P)7.0 INSPECTION AND TESTING7.1 General4Package Plant to Include /be Included in a Fieldbus Network (Y/N) (P)4Reference for Purchaser’s Particular Specification (P)7.2 Inspection and Testing of the Assembly7.2.1 General1Additional Tests Required () (P)aWitness FATsbSite commissioning tests7.2.2 Factory Acceptance Tests (FATs)1Samples of Supplier’s test schedules to be submitted before testing (Y/N) (P)3Additional FATs Required () (P)aInjection testing of incomer protection circuitsbInjection testing of motor starter protection circuitscResponse testing to simulated voltage dipsdSerial communication network testing7.2.3 Witness Factory Acceptance Tests (If Required)2Availability/Distribution of Supplier’s Test Schedules (P)aSchedules to be made available to the Purchaser at witness FATsbSchedules to be sent to the Purchaser before witness FATs3Witness FATs to Include () (P)aRoutine Tests to BS EN 61349Constructional:iDegree of protection of enclosuresiiClearance and creepage distancesiiiProtection against electric shock and integrity of protective circuitsivIncorporation of built in componentsvInternal electric circuits and connectionsviTerminals for external conductorsviiMechanical operationPerformance:iDielectric propertiesiiWiring, operational performance and function3Additional TestsiInjection testing of incomer protection circuitsiiInjection testing of motor starter protection circuitsiiiResponse testing to simulated voltage dipsivSerial communication network testing4Details of Any Further Witness FATs Required (P)5DOC (to BS EN 61439-2) to be Available at Witness FATs (Y/N) (P)7.2.5 Site Commissioning Tests (If Required)1Tests to be Witnessed by the Purchaser (Y/N) (P)3Details of Any Further Testing or Commissioning Activities Required (P)7.3 Inspection and Testing of the Installation7.3.1 General3Additional Inspection & Testing Reqd. (as Part of Process Commissioning) (Y/N) (P)appendix c2 - MOTOR STARTER DATA SHEETPACKAGE PLANT (ELECTRICAL)DRIVE DESIGNATION ____________________1Motor Starter Details (S)TypeDirect-on-lineStar deltaReversingTwo speedSoft start/stopVariable speedVoltage400 V 3 phase230 V 1 phaseOther (specify)RatingOutput (kW)Full load current (A)Starting current (xFLC)Number of starts per hourPower FactorUncorrected motor power factorDRIVE DESIGNATION ____________________1Motor Starter Details (S)TypeDirect-on-lineStar deltaReversingTwo speedSoft start/stopVariable speedVoltage400 V 3 phase230 V 1 phaseOther (specify)RatingOutput (kW)Full load current (A)Starting current (xFLC)Number of starts per hourPower FactorUncorrected motor power factorDRIVE DESIGNATION ____________________1Motor Starter Details (S)TypeDirect-on-lineStar deltaReversingTwo speedSoft start/stopVariable speedVoltage400 V 3 phase230 V 1 phaseOther (specify)RatingOutput (kW)Full load current (A)Starting current (xFLC)Number of starts per hourPower FactorUncorrected motor power factorDRIVE DESIGNATION ____________________1Motor Starter Details (S)TypeDirect-on-lineStar deltaReversingTwo speedSoft start/stopVariable speedVoltage400 V 3 phase230 V 1 phaseOther (specify)RatingOutput (kW)Full load current (A)Starting current (xFLC)Number of starts per hourPower FactorUncorrected motor power factorAPPENDIX D – SUPPLIER’S SUPPLEMENTARY DATA SHEET INFORMATIONClauseSupplementary Information ................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download