Section 10440 - Interior Signage - APCO Signs



SECTION 10 14 00

PATIENT INFORMATION SIGNAGE

Display hidden notes to specifier by using “Tools”/”Options”/“View”/”Hidden Text”

OR

by pressing the MS Office Button / “Word Options” / “Display” / “Hidden Text”

**NOTE TO SPECIFIER** APCO Signs; interior sign systems.

1 GENERAL

1. SECTION INCLUDES

A. Interior modular patient room information signage.

2. RELATED SECTIONS

**NOTE TO SPECIFIER** Delete any sections below not relevant to this project; add others as required.

A.

B. Section 08 14 00 - Wood Doors.

C. Section 09 29 00 - Gypsum Board Systems.

D. Section 09 51 00 - Acoustical Ceilings.

E. Section 09 70 00 – Wall Finishes.

3. REFERENCES

**NOTE TO SPECIFIER** Delete references from the list below that are not actually required by the text of the edited section.

A.

B. Department of Justice, Office of the Attorney General, "Americans with Disabilities Act", Public Law 101-336, (ADA).

C. Federal Register Part II, Architectural and Transportation Barriers Compliance Board, 36 CFR Part 1191: Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Amendment to Final Guidelines, September 6, 1991.

D. Federal Register Part III, Department of Justice, Office of the Attorney General, 28 CFR Part 36: Nondiscrimination on the Basis of Disability by Public Accommodations and in Commercial Facilities, Final Rule, July 26, 1991.

4. DEFINITIONS

A. Terms:

1. Braille: Grade 2 Braille including 189 part-word or whole word contractions in addition to Grade 1 Braille 63 characters. Tactile is required whenever Braille is required.

2. Non-tactile: Letters and numbers on signs with width-to-height ratio between 3:5 and 1:1 and stroke width ratio between 1:5 and 1:10 using upper case "X" to calculate ratios. Use type styles with medium weight; upper and lower case lettering is permitted; serif typestyles are permitted.

a. Symbols: Symbol itself is not required to be tactile but equivalent verbal description is required both in tactile letters and braille.

3. Tactile: 1/32 inch (0.80 mm) raised capital letters without serifs at least 5/8 inch (16 mm) height and not more than 2 inches (51 mm) height based on upper case "X". Braille is required whenever tactile is required.

5. SYSTEM DESCRIPTION

A. Signage under this section is intended to include items for patient room identification and client-controlled, secured display of information applicable to specific patients. Patient room signage may also be an integrated element of a complete sign and wayfinding system.

B. ADA design requirements:

1. Signage requiring tactile graphics:

a. Wall mounted signs designating permanent rooms and spaces such as, room numbers and restroom, department, office, and fire exit identifications.

b. Individually applied characters are prohibited.

2. Signage not requiring tactile graphics but which are required to comply to other ADA requirements include signs providing direction to or information about function of space such as, directional signs (signs with arrow), informational signs (operating hours, policies, etc.), regulatory signs (no smoking, do not enter), and ceiling and projected wall mount signs.

3. Excluded signage:

a. Exterior signs.

b. Building directories.

c. Menus.

d. Temporary signs, include personnel signs and tenant identification; suite numbers are not considered temporary.

C. ADA performance requirements:

1. Tactile graphics signs mounting requirements:

a. Single doors: Mount 60 inches (1524 mm) to sign centerline above finish floor and on wall adjacent to latch side of door.

b. Openings: Mount 60 inches (1524 mm) to sign centerline above finish floor adjacent opening.

c. No wall space adjacent latch side of door, opening, or double doors: Mount 60 inches (1524 mm) to sign centerline above finish floor on nearest adjacent wall.

6. SUBMITTALS

A. Submit under provisions of Section 01 32 00.

B. Product Data: Manufacturer's data sheets on each product to be used, including:

1. Manufacturer's product literature indicating units and designs selected.

2. Evidence of manufacturer's computerized data retrieval program for tracking of project for sign typography, message strip requirements and other pertinent data from schedule input to final computerized typography on finished product.

3. Preparation instructions and recommendations.

4. Storage and handling requirements and recommendations.

5. Installation methods.

C. Samples: One full size sign sample illustrating the design, construction, colors, typestyles, mounting method and other details as specified. Provide sample in small size sign.

**NOTE TO SPECIFIER** Delete provision not required.

1.

2. Samples will not be returned for use in Project.

D. Shop Drawings:

1. Indicate materials, sizes, configurations, and applicable substrate mountings.

2. Typography sample for message strips and headers copy.

**NOTE TO SPECIFIER** Option. Delete if not required.

3.

**NOTE TO SPECIFIER** Option. Delete if not required.

4.

E. Signage Schedule: Complete with location of each sign and the required copy/text.

F. Sign Program Maintenance Plan:

1. Manufacturer shall provide details of software and system of pre-perforated and color coated paper sign inserts allowing client to update and maintain signage graphics in-house.

2. Manufacturer shall provide details of an Online Reordering & Maintenance Application whereby the client can submit sign reorders online and store relevant project information such as sign type drawings, message schedules and product instructions.

G. Contract close out:

1. Furnish appropriate checklist for aiding in reordering after Date of Substantial Completion. Maintain computer schedule program for five years for ordering new signage required by Owner.

2. Maintenance data and cleaning requirements for exterior surfaces.

**NOTE TO SPECIFIER** Manufacturer has available software program for personal computers - pc, called "SignWord Pro" enabling end user to produce graphics on insert or sign face. Information in main catalog. Call manufacturer directly at listed telephone number for more info. Delete if not required.

3.

**NOTE TO SPECIFIER** Option. Delete if not required.

7.

A. Manufacturer Qualifications:

1. Work required under this section from manufacturer regularly engaged in work of this general type and scope for a minimum of 5 years.

2. Maintain computer link between schedule input and computerized typography production.

B. Installer Qualifications: Trained and authorized by manufacturer for installations of required scope and product.

**NOTE TO SPECIFIER** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.

C.

1. Finish areas designated by Architect.

2. Do not proceed with remaining work until workmanship, graphics, and installation are approved by Architect.

3. Refinish mock-up as required to produce acceptable work.

8. DELIVERY, STORAGE, AND HANDLING

A. Package signs to prevent damage during shipment, handling, storage and installation. Products are to remain in their original packaging (unless otherwise specified) until removal is necessary for installation.

B. If installation site is not ready for signage upon delivery, store signs in a dry, air-conditioned environment.

C. Handle signage in accordance with manufacturer’s instructions.

D. Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction.

9. PROJECT CONDITIONS

A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.

10. SEQUENCING AND SCHEDULING

A. Schedule system installation after room finishes and fixtures have been completed.

11. WARRANTY

A. Product Warranty: Provide manufacturer’s warranty against defects in materials and workmanship for a period of one year.

2 PRODUCTS

1. MANUFACTURERS

A. Acceptable Manufacturer: APCO Graphics, Inc. (aka APCO Signs); 388 Grant St. S.E., Atlanta, GA 30312. ASD. Toll Free Tel: (877) 988-2726. Tel: (404) 688-9000. Fax: (404) 577-3847. Email: sales@. Web: .

**NOTE TO SPECIFIER** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.

B.

C. Requests for substitutions will be considered in accordance with provisions of Section 01 25 00.

**NOTE TO SPECIFIER** Warning: APCO supports the goal of making facilities accessible and has developed guidelines in an effort to promote voluntary compliance. APCO provides information and guidelines on the Americans with Disabilities Act (ADA) on a voluntary basis, having used extreme care and high standards to assure accuracy in interpretation of the law. However, all information, either written or verbal, is strictly an interpretation and is presented with no warranty either expressed or implied. APCO officers, staff, representatives, and/or consultants assume no legal responsibility for the accuracy of presentations, comments or other ADA information. Neither is liability assumed for the outcome of decisions, contracts, commitments or obligations made on the basis of this information. APCO guidelines are taken from the Department of Justice's final rules implementing Title III of the Americans with Disabilities Act, printed in the Federal Register, 28 CFR, Part 36, 26 July 1991. APCO recommends that anyone affected by ADA obtain a copy of The Americans with Disabilities Act and consult their legal counsel.

2.

A. InfoLock Patient Information System as manufactured by APCO Signs.

3. SYSTEM REQUIREMENTS

A. General:

1. Sign system shall have the ability to display patient room identification information, including tactile room number and Braille, as well as client-controlled, secure patient information messages and symbols applicable to specific patients.

2. Signs within the system shall feature the same family of components, shall convey a uniform look throughout and shall be able to integrate aesthetically with a complete sign and wayfinding system.

B. Features:

1. Modularity: Signs shall allow for the display of a range of updatable inserts, including but not limited to digitally printed graphics protected by a non-glare lens, tactile/Braille room numbers, decorative materials and other types of custom graphics and/or messages, health related or otherwise.

2. Patient Information Messages & Symbols: All patient information messages and symbols shall be housed within sliding 1.75 inch h extruded aluminum tabs that can be fully concealed and locked behind the sign frame when not in use. When in use, patient information message and symbol tabs shall slide to a visible position to the left and/or right side of the sign where they automatically lock securely in place and display a 1.75 inch h by 4.5 inch w message, symbol or message/symbol combination or a 1.75 inch h by 2.5 inch w symbol only. Display bands shall only release by pressing a fully concealed button to prevent tampering. Patient information bands shall be able to be placed into visible positions or returned to concealed positions easily without removal of the sign itself. Display bands shall be available in sets (4), (6), (8), (12) or (16) with any combination of bands concealed or visible at one time. Message/symbol graphics shall be removable and updatable by in-house staff.

3. Mounting: Signs shall accommodate installation via fully concealed

mechanical fasteners.

C. Graphics and Typography: As selected from manufacturer’s standards. Reference sign drawings.

D. Colors and Finishes: As selected from manufacturer’s standards. Reference sign drawings.

E. ADA Compliance: Sign system shall comply with all current and applicable ADA regulations, including requirements regarding which sign types require Braille/tactile features, character heights, color contrast and installation locations and mounting heights within the facility.

F. Materials and Construction:

1. 1st Surface Sign Frames/Holders:

**NOTE TO SPECIFIER** Delete either option a. or b. below as applicable.

a.

b. Low profile sign frames of APCO’s FullView Sign System. Low profile sign frame assembly shall feature a combination of aluminum extrusions and aluminum composite material and shall have a depth of 7/16 inches (12mm) or less. Aluminum extrusions shall contain a minimum of 50% post consumer recycled content and shall be extruded in the USA. Modular sign holders shall accommodate a range of various insert materials up to 1/8 inch thick, including but not limited to digitally printed graphics protected by a removable non-glare lens. Sign frame aluminum edge profile options include the following:

** NOTE TO SPECIFIER** Delete all but one of the below edge profile options if using the FullView sign system.

1)

2) Radius (FVST-R)

3) Bevel (FVST-B)

4) Contour (FVST-C)

5) Contour Ribbed (FVST-CR)

2. Subsurface Patient Information System: System of patient information symbols and messages shall consist of an extruded aluminum frame, alloy 6063-T6, with a maximum depth of ¾” which houses a modular tracking system of 1-3/4 inch h sliding and lockable extruded aluminum tabs and precision injection molded components to enable locking capabilities. Updatable patient messages and symbols can be digitally printed or silkscreen printed on a durable vinyl material.

3. Braille / Tactile Components: PETG-backed photopolymer with raised characters and Braille of minimum 1/32 inch (0.8 mm) depth/thickness. Braille/tactile plaques shall contain a minimum of 40% recycled content.

4. Fasteners: Signs shall be able to accommodate fully concealed mechanical fasteners.

4. SIGN SYSTEM COMPONENTS

**NOTE TO SPECIFIER** Choose either A or B below and delete the other section.

A.

**NOTE TO SPECIFIER** Delete all options below that are not applicable.

1.

a. INFOAR-4R (4 message sign with 4.5 inch tabs displaying to the Right)

b. INFOAR-4L (4 message sign with 4.5 inch tabs displaying to the Left)

c. INFO2AR-4R (4 message sign with 2.5 inch tabs displaying to the Right)

d. INFO2AR-4L (4 message sign with 2.5 inch tabs displaying to the Left)

e. INFO2AR-4RL (8 message sign with 2.5 inch tabs displaying on Both Sides)

f. INFOAR-6R (6 message sign with 4.5 inch tabs displaying to the Right)

g. INFOAR-6L (6 message sign with 4.5 inch tabs displaying to the Left)

h. INFO2AR-6R (6 message sign with 2.5 inch tabs displaying to the Right)

i. INFO2AR-6L (6 message sign with 2.5 inch tabs displaying to the Left)

j. INFO2AR-6RL (12 message sign with 2.5 inch tabs displaying to Both Sides)

k. INFOAR-8R (8 message sign with 4.5 inch tabs displaying to the Right)

l. INFOAR-8L (8 message sign with 4.5 inch tabs displaying to the Left)

m. INFO2AR-8R (8 message sign with 2.5 inch tabs displaying to the Right)

n. INFO2AR-8L (8 message sign with 2.5 inch tabs displaying to the Left)

o. INFO2AR-4R2 (8 message double sign with 2.5 inch tabs displaying to the Right)

p. INFO2AR-4L2 (8 message double sign with 2.5 inch tabs displaying to the Left)

q. INFO2AR-4RL2 (16 message double sign with 2.5 inch tabs displaying to Both Sides)

2. InfoLock/Arcadia Sign With a Slider Insert

a. INFOARSL-4R (4 message sign with 4.5 inch tabs displaying to the Right)

b. INFOARSL-4L (4 message sign with 4.5 inch tabs displaying to the Left)

c. INFO2ARSL-4R (4 message sign with 2.5 inch tabs displaying to the Right)

d. INFO2ARSL-4L (4 message sign with 2.5 inch tabs displaying to the Left)

e. INFO2ARSL-4RL (8 message sign with 2.5 inch tabs displaying on Both Sides)

f. INFOARSL-6R (6 message sign with 4.5 inch tabs displaying to the Right)

g. INFOARSL-6L (6 message sign with 4.5 inch tabs displaying to the Left)

h. INFO2ARSL-6R (6 message sign with 2.5 inch tabs displaying to the Right)

i. INFO2ARSL-6L (6 message sign with 2.5 inch tabs displaying to the Left)

j. INFO2ARSL-6RL (12 message sign with 2.5 inch tabs displaying to Both Sides)

k. INFOARSL-8R (8 message sign with 4.5 inch tabs displaying to the Right)

l. INFOARSL-8L (8 message sign with 4.5 inch tabs displaying to the Left)

m. INFO2ARSL-8R (8 message sign with 2.5 inch tabs displaying to the Right)

n. INFO2ARSL-8L (8 message sign with 2.5 inch tabs displaying to the Left)

3. InfoLock/Arcadia Sign w/ Custom Options and/or Configuration (INFOAR-C)

B. InfoLock with Low-Profile FullView Sign System (approx 7 inch w display width)

**NOTE TO SPECIFIER** Delete all options below that are not applicable.

1.

a. INFOFV-4R (4 message sign with 4.5 inch tabs displaying to the Right)

b. INFOFV-4L (4 message sign with 4.5 inch tabs displaying to the Left)

c. INFO2FV-4R (4 message sign with 2.5 inch tabs displaying to the Right)

d. INFO2FV-4L (4 message sign with 2.5 inch tabs displaying to the Left)

e. INFO2FV-4RL (8 message sign with 2.5 inch tabs displaying to Both Sides)

f. INFOFV-6R (6 message sign with 4.5 inch tabs displaying to the Right)

g. INFOFV-6L (6 message sign with 4.5 inch tabs displaying to the Left)

h. INFO2FV-6R (6 message sign with 2.5 inch tabs displaying to the Right)

i. INFO2FV-6L (6 message sign with 2.5 inch tabs displaying to the Left)

j. INFO2FV-6RL (12 message sign with 2.5 inch tabs displaying to Both Sides)

k. INFOFV-8R (8 message sign with 4.5 inch tabs displaying to the Right)

l. INFOFV-8L (8 message sign with 4.5 inch tabs displaying to the Left)

m. INFO2FV-8R (8 message sign with 2.5 inch tabs displaying to the Right)

n. INFO2FV-8L (8 message sign with 2.5 inch tabs displaying to the Left)

o. INFO2FV-4R2 (8 message double sign with 2.5 inch tabs displaying to the Right)

p. INFO2FV-4L2 (8 message double sign with 2.5 inch tabs displaying to the Left)

q. INFO2FV-4RL2 (16 message double sign with 2.5 inch tabs displaying to Both Sides)

2. InfoLock/FullView Sign With a Slider Insert

a. INFOFVSL-4R (4 message sign with 4.5 inch tabs displaying to the Right)

b. INFOFVSL-4L (4 message sign with 4.5 inch tabs displaying to the Left)

c. INFO2FVSL-4R (4 message sign with 2.5 inch tabs displaying to the Right)

d. INFO2FVSL-4L (4 message sign with 2.5 inch tabs displaying to the Left)

e. INFO2FVSL-4RL (8 message sign with 2.5 inch tabs displaying to Both Sides)

f. INFOFVSL-6R (6 message sign with 4.5 inch tabs displaying to the Right)

g. INFOFVSL-6L (6 message sign with 4.5 inch tabs displaying to the Left)

h. INFO2FVSL-6R (6 message sign with 2.5 inch tabs displaying to the Right)

i. INFO2FVSL-6L (6 message sign with 2.5 inch tabs displaying to the Left)

j. INFO2FVSL-6RL (12 message sign with 2.5 inch tabs displaying to Both Sides)

k. INFOFVSL-8R (8 message sign with 4.5 inch tabs displaying to the Right)

l. INFOFVSL-8L (8 message sign with 4.5 inch tabs displaying to the Left)

m. INFO2FVSL-8R (8 message sign with 2.5 inch tabs displaying to the Right)

n. INFO2FVSL-8L (8 message sign with 2.5 inch tabs displaying to the Left)

3. InfoLock/FullView Sign w/ Custom Options and/or Configuration (INFOFV-C)

C. Graphics:

1. Patient information messages and symbols as indicated in SCHEDULE and drawings.

2. Type Sizes: Selected from manufacturer's standard sizes indicated in SCHEDULE for particular units; meet ADA requirements for letter proportions and sizes.

3. Typography: Reference signage schedule and drawings for details. Font(s)

selected from manufacturer’s standards unless otherwise specified. All text

and graphics shall be a true representation of the typeface(s) and/or graphics

specified. Letter spacing and interline spacing shall be set by the manufacturer.

5. FABRICATION

A. Shop assembly:

1. Fabricate units to configurations indicated on reviewed shop drawings.

2. Provide copy on inserts, and covers required on reviewed shop drawings and in accord with ADA requirements.

3. Provide additional blank paper as specified.

4. Include instruction sheets for removal and replacement inserts and installation.

3 EXECUTION

1. EXAMINATION

A. Do not begin installation until substrates have been properly prepared.

B. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.

2. PREPARATION

A. Clean surfaces thoroughly prior to installation.

B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

3. INSTALLATION

A. Install products in accordance with manufacturer’s instructions, in locations and with mounting methods as specified in sign and location drawings.

B. Square, plumb and level all installed products.

C. Install all signage in accordance with the Americans with Disabilities Act Accessibility Guidelines (ADAAG) and any applicable local regulations and/or codes.

D. Upon completion of the work, sign installer shall remove any unused products, materials, packaging and debris from the installation site.

4. CLEANING

A. Clean all exposed surface not more than 48 hours prior to Date of Substantial Completion in accordance with manufacturer’s written cleaning instructions.

5. PROTECTION

A. Protect installed products until completion of project.

B. Touch-up, repair or replace damaged products before Substantial Completion.

6. SIGN SCHEDULES

A. Refer to Signage Schedule and Drawings for sizes, locations, sign types, layouts, typestyle specifications, sign text/copy and sign graphics.

END OF SECTION

................
................