5 x Pielstick 18PC4-18MW (90Mw) 60Hz HFO Generating Plant

[pic]

[pic]

[pic]

[pic]

Price for entire plant: US $720,000 EACH

The engines are HFO/bunker fired.

HFO treatment plant is included.

Engines

Make Chantier De L' Atlantique (France)

Model 18PC4 Pielstick Engine

Type Turbo Charge With Governor, Four Cycle, Single Acting, Solid Injection, Water Cooled, Vee Type, Trunk Piston, Forced Lubricated, Supercharge Stationary Diesel Engine

Air Started:

Turbo-Chargeer: Chantier's De L'Atlantique

Rated Capacity: 18MW

Horse Power Rating: 2700HP

Horse Power: 26,650 Bhp Rated Continuous Output

No. Of Cylinder: 18

Rpm: 400

Cylinder Bore: 570mm

Piston Stroke: 620mm

BMEP At Rated Output: 20.4 Kg/ Cm2 At Site

Maximum Combustion: 120 Kg/ Cm2

Mean Piston Speed: 8.3 M/S

Total Length: 12, 800 Mm

Width: 4, 480 Mm

Height For Crank Center: 4, 550 Mm

Weight: 282 Tons

Generators

Make: CEM Cie Electro Mecanique

Type: WAPD 284110/18

Rated Capacity: 24,100 Kva

Terminal Voltage: 13, 800 V

Amps. 1008 A

Frequency: 60 Hz

Rpm: 400

Power Factor: 0.80

Phase 3

Protection: IP 20

Insulation Class: F

Weight: 80 Tons

Excitation

Type: Brushless RK 105-18

Voltage: 82 Kv

Amps: 790a

Governor

Make: Regulateurs Europa Ltd. England

Type : 1502/ 26 Series 1500

Maximum Output: 0-10

Working Capacity: 270 J, Working Press 21 Kgf/Sq Cm

Input Speed: 230-1150 Rpm

Working Pressure: 21 Kgf./Sq Cm

Input Speed: 230-1150 Rpm

With Mechanical & Electrical Auxiliaries.

ENGINE-GENERATOR

1 Diesel Electric Generating Set-5 set 1977

a. Diesel Engine:Chantiers de Atlantique SEMT Pielstick, Type 18P4, 18-cylinder,2700 hp, 400 rpm, turbo-charged, with governor, unit completewith machinery foundation, local control panel, installation andstandard accessories.

b. Electric Generator-5 set 1977. Consisting of five (5) units installed A.C. Generator -CEM (CieElectro- Mesanique), France, Type WAPD284-110/18, 24100 KVAcapacity, 0.8 p.f.. 13,800 volts, 400 rpm, 3-phase 60-cycle, with158 kw rating DC generator, Type ET98-30, 23 TV, 400 rpm, CI-plete with bearing and accessories.

Unit 1 SN - 7020

Unit 2 SN - 7021

Unit 3 SN - 7022

Unit 4 SN - 7023

Unit 5 SN - 7024: with few accessories within the powerhouse premises only

Unit 6 SN -7025

ACCESSORY ELECTRICAL EQUIPMENT

1. Main Control Switchboard-1 lot 1977. Cie Electro-Mecanique, consists of: Duplex type controlswitchboard, consisting of: 6 - Generator Control Panels. 6-EngineControl Panels, 1 - Transformer Main Control Switchboard, 1 -Station Service Transformer Control Panel Switchboard completewith meters and relaying equipment, bus potential transformers,control switches, annunciator boxes, indicating lamps, panelbuttons, terminal block and accessories. Located at control room.

2. 15 KV Metal Clad Switchgear-2 set 1977. Alsthom, indoor type consisting of fourteen (14) cubicles, with circuit breakers assemblies, potential transformer, current transformers, capacitor, resistors, indicating lamps, terminal blockand bus bar interconnections and other accessories. Located at 2nd Floor near 12PC2.5 side.

3. 440 V Station Service Switchgear (LV)-1 lot 1977. Redon Dalmon, compartmentalized panel, consisting of several drawers housing, draw-out type circuit breakers, meters, relays, control switches, signal lamps. fuses, terminal blocks and bus bar interconnections. Located at control room.

4. 125 V DC Panel (12PC2.5) 1 unit 1975 0.0254% Drawer type panel for 125 VDC, distribution branch circuits, complete with circuit breakers, control switches. meters, relays, signal lamps and accessories. Located at control room.

5. 115 V AC Panel (12PC2.5)-1 unit 1975. Drawer type panel for 115 V AC, distribution branch circuits, complete with circuit breakers, control switches, meters, relays, signal lamps, terminal blocks and accessories. Located at control room.

6. Station Battery Equipment-1 lot 1977. Consisting of: Two (2) - Station Battery Bank - Yuasa and Oriental, 60 cells/bank, 125 volts and one (1) . Battery Chargers - CoredeL, complete with voltmeters, ammeters, lights and switches. Located

at battery room.

7. Cable Trays-1 lot 1977. Steel, locally fabricated in various sizes, complete with supports and hangers.

8. Power and Control Cables-1 lot 1977. Consisting of various sizes and capacities of cable wires, insulated type, complete with connectors, grounding cables, insulating materials and other accessories.

9. Motor Control Center Panel-1 unit 1977. BBC,(Common) consisting of: MCC Panel - 7 sections, system complete with circuit breakers, selector and Band sectionalizing switches, resistors, relays. signal lamps, terminal blocks and bus

wiring and other accessories. Located at ground floor of powerhouse.

10. Motor Control Center Panel-6 unit 1977. BBC, consisting of: MCC Panel . 6 sections, system complete with circuit breakers, selector and sectionalizing switches, resistors, relays, signal lamps, terminal blocks and bus wiring. Located at

ground floor of powerhouse.

11. Motor Control Center Panel-1 unit 1975-Dalmon, (Common) consisting of MCC panel, 4 section, complete with circuit breaker, switches, relays, lamps, wirings, and other accessories. Located at 2nd floor of powerhouse, 12PC2.5.

12. Excitation Cubicle- 6 unit 1977. Complete with line voltage, excitation voltage and excitation current. Located at control room.

13. 115 VAC Panel-1 unit 1977. 18PC4 plant system. Located at control room.

14. 125 VDC Panel-1 unit 1977. 18PC4 plant system. Located at control room.

[pic]

[pic]

[pic]

STRUCTURES AND IMPROVEMENTS

1. Powerhouse/Control and Office Building 1 unit-1977. This is a three storey, reinforced concrete framed bldg. with sandblast finish reinforced concrete walls and aluminum sidings at the portion, corrugated aluminum sheet roofing on the steel frames, granolithic tile and steel grating finish generator floorlevel, metal louvers, steel awning windows, with glass panes andsteel roll-up doors. Control and office bldg. are housed in the adjoining three storey bldg with vinyl tile finish flooring, acoustic board ceiling on aluminum T-runner, concrete hollow block partitions, and plywood flush type and glass on aluminum frame doors. The bldg. is painted and provided with electrical lighting. Plumbing facilities and/or air conditioning system. Total floor area is approx. 12,645 sq.m. Located at plant compound.

2. Water Treatment Shed-1 unit-1980 One story open building with timber post, corrugated GI sheet roofing on timber frames, plain cement finish concrete floor, provided electrical lightings. Floor area is approx. 18 sq.m.Located at plant compound.

3. Pump Houses (HFO) 2 unit 1977. These are one storey concrete framed bldg., with plastered concrete block walls, corrugated GI sheet roofing on timberframes, plain cement concrete finish floor, wood sash windows with glass panes and plywood flush type door. Painted and provided with electrical lighting. Floor area is approximately 1 5 sq. m. Located at tank farm.

4. Pump Houses (LFO) 1 unit 1977. These is one storey, concrete framed bldg with plastered concrete block walls, corrugated GI sheet roofing on timber frames, plaincement finish concrete floor, wood sash windows with glass panesand plywood flush type door. Painted and provided with electrical lighting. Floor area is approx. 15 sq.m. Located at plant compound.

5. Fire fighting Pump House-1 unit 1977. A one storey concrete framed bldg. with plastered concrete CHBwalls, corrugated GI sheet roofing on timber frames, plain cementfinish concrete floor, asbestos ceiling, steel grilled window openings and plywood flush-type door. It is provided with electrical facility. Floor area is approx. 25 sq.m. with one side 10ft high firewall. Located at plant compound.

6. Firefighting Foam House-1 unit 1977. A one storey concrete framed bldg., with plastered concrete CHB walls, corrugated GI sheet roofing on timber frames, plain cement finish concrete floor, asbestos ceiling, steel grilled door. It is provided with electrical lighting. Floor area is approximately 25 sq. m., with one side 10 ft. high firewall. Located at tank farm.

7. Radiator Support Structure-1 Lot 1977. A one-story concrete framed structure, which supports the air-to-air radiator units. Column size is 0.90 m. x 0.90 m. x 5 m. high.Total number of columns is 119. The beam size is approx. 0.70 m. x0.90 m., column spacing is 6.0 m. Located at radiator area.

8. Fire Pond-1 unit 1977. It is a semi-underground concrete storage tank with a size of 22 m.long by 10 m. wide, and about 5 m. deep. The wall thickness is about 0.20 m. and the tank has a concrete slab cover. Located at plant compound.

9. Maintenance Shop-1 unit 1977. A one storey bldg. partially open with corrugated metal roof on timber frame, timber column, plywood ceiling, CHB watt on onebay, plain cement flooring, glass jalousie window plywood flushtype door and electrical facility. Located at plant compound.

10. Bund Wall For Settling Tank-1 unit 1977. It is a cast-in-place reinforced concrete wall about 0.20m thick,2.4m high and total length is 80m. Located at plant compound.

11. Sludge Pool-Sludge Pool 1 unit 1977. One story structure with corrugated GI roof, timber frame 2.5high, CHB wall. Total area is 50 sq. m. Located at tank farm.

12. Cable Trench-1 lot 1977. It is made of cast-on-placed concrete with concrete cover 0.15m thick wall and floorings. Located at front of powerhouse.

13. Oil I Water Separator-2 unit 1977. A one storey concrete structure, reinforced concrete wall anddivisions about 6.82 m long, 3.2 m and wall thickness of 18 cm.Located at tank farm.

14. Fuel Recovery Plant-1 unit 1977. A one story concrete structure, reinforced concrete wall and divisions provided with electrical lighting facilities. About 18.5 m long, 10.5 m wide, with a height of 2.5 m and wall thickness of 18 cm. Located at tank farm.

15. Oil I Water Separator-2 unit 1977

(1) A 417 cm long, 310 cm wide and 16 cm wall thickness concretestructure.

(2) A 186 cm long, 238 cm wide and 10 cm wall thickness concrete structure with 4 cm diameter tube fence. Located at tank farm.

16. Fuel Measuring Shed / Post-PC 1977. This is an open frame post with corrugated iron sheet roofing witha total height of 418 cm. The structure is provided with 152 x 148 x 190 cm (LWH) upper deck accessible by metal sheet stairs. Locatedat plant compound.

17. Flag Pole-PC. This is a 3Oft. metal pole, 8 inches in diameter with concrete foundation Located at plant compound.

FUEL HOLDERS, PRODUCERS AND ACCESSORIES

1. HFO Storage Tank 3 unit 1977 1.1234, 5 million liters capacity steel plate welded construction. 21.04 m x 14.60 to high outside dimension, with heater, complete with

steel ladder platform and other accessories. Located at tank farm.

2. HFO Sludge Storage Tank (Tank Farm) 1 unit 1977. 2.7 million liters cp., steel plate welded construction, 16.507 m dia 12.82 m high outside dimension, complete with steel ladder platform and other standard accessories. Located at tank farm.

3. Light Fuel Oil Day Tank-1 unit 1977. Mild steel plate welded construction, 2743 mm dia x 6069 mm long outside dimension, saddle support, catwalk platform and other accessories. Located at plant compound.

4. HFO Day Tank-6 unit 1977 0.1381% Mild steel plate welded construction, 2.14 m dia. 6.7 m length dimension, saddle support, catwalk platform, heater, with thermostatic controls and other accessories. Located at back of powerhouse.

5. LFO Storage Tank-1 unit 1977. 500KL cap., steel plate welded construction. 8 m. dia x 11.58 to outside dimension complete with catwalk, heater, and other.

6. HFO Settling Tank-2 unit. 100KL cap,, mild steal plate welded construction, 6 m dia x 6 to high outside dimension complete with steam heater and ladder and other accessories. Located at back of powerhouse.

7. Sludge Tank-1 unit 1975. 211 cap., mild steel plate welded construction, 1219 mm dia 1829 mm long outside dimension with heater and other

8. Drip Tank-3 unit 1977 0. Mild steel plate material of welded construction, 2 m dia x 6.7 mlong on steel saddles with steam heater and other accessories.Located inside 1BPC4 powerhouse,

9. HFO Transfer Pump-2 unit 1979. Type 4V200, 50 cu.m./hr. cap., each driven by 11 kv electric motor, 460 volts complete with pipings and valves other accessories. Located at tank farm. land

10. HFO Final Filters-12 unit 1977. Eurofilter WinsLow, type J-68-164-A-P7-CS-T-IN, complete with 68fitter elements with 6 heaters (1 per engine). Located at 1BPC4powerhouse.

11. HFO Filter-2 unit 1975. Winslow, Type J-24-1 645-A- P1 2-CS•T-lN, with 24 filtering elementsand pipings (Note: Two (2) units per system. Located at 12PC2.5area.

12. LFO Transfer Pump -1 unit 1977. Mouvex series Nos. AR 338544, each with: 11 kw drive motor-CEM,complete with piping and other accessories.

13. Drip Transfer Pumps-3 unit 1977. Mouvex, Type AX-310, 7 cu. m./hr. capacity, each driven by 2.2 kwelectric motor. 460 volts and other accessories. Located at groundfloor of powerhouse. Note: one tank and one pump for every two engines.

14. Fuel Piping System-1 lot 1977. Heavy and light fuel piping system of various sizes complete withasbestos, insulator, valves, fitting and flange connection withinthe tank farm and plant compound. Located at plant compoundand tank farm.

15. Line Steam Heater-6 unit 1977. Fryer and Cie, steam 14 VA, 200,000 l ................
................

In order to avoid copyright disputes, this page is only a partial summary.