Business Solutions Manager



Our Grid synchronized solar power inverter is an advanced 4 quadrant bidirectional inverter that helps satiate the power demands of residential / industrial sectors in developing nations. It consists of state-of-the-art ruggedized grid feeding inverter along with high efficiency solar charge controller. Using this system excess power can be exported to grid and at the same time can be provided back for critical loads via battery storage. It comes in all capacities ad battery voltages to cater to all kinds of applications.The same technology can be used for battery-less systems of pure grid export type. It can be synchronized both with mains and DG to support the loads along with EB / DG supply.True 4 quadrant rugged IGBT based inverterProgrammable current control for Grid synchronized modeUPS mode of operation at load endExcellent yield from solar through MPPT based charge controllerCustomized for operation with or without batteryExcellent performance up to 50?CGalvanic isolation using power transformerAvailable in all capacities / battery voltagesDigital display with fault and energy loggingRemote monitoring over RS-458 and internetSingle Phase Off Grid Solar Power ConditionerSolar Hybrid DC Power Supply Unit3 Phase Solar Grid Export InverterIntelligent String Monitor3 Phase Solar Power ConditionerArray Junction BoxSingle Phase Grid Interactive Solar Power ConditionerMPPT Charge ControllerTechnical DetailsNominal Capacity1-3 KVA4-6 KVA7.5-12.5 KVA12.5-25 KVANominal DC Voltage48V96 / 120V120V / 240V240VOverload Capacity150% for 60 seconds, 125% for 10 secondsEfficiency>90% at rated load, nominal input voltageSwitching DevicesMOSFET / IGBTIGBTASolar Charger OptionTopologyMPPT (Buck Type)Switching DeviceIGBTMPPT Range60-128V MP120-195V MP155-255 MP300-510V MPMax PV Voltage150V230V300V600VBGrid Interactive ModeAC Voltage Range230V AC, +/- 15%AC Frequency Window47-53 HzCStand Alone UPS ModeNominal Output AC240V, 50 Hz (Factory adjustable for +/- 10%)Output Regulation+/- 2%Frequency50 Hz +/- 0.1 Hz (Factory Adjustable)Current THD<3%Changeover Time5-10msSystem BypassInternal Automatic Bypass on ShutdownDGen-set Interactive OptionControl MethodAC InteractiveStart ConditionsGrid Failure and Low Battery State of ChargeStop ConditionsGrid Recovery or Low Gen-set LoadingStart / Stop SignalsPotential Free Contact ProvidedEProtection / Display / CommunicationProtectionInverter Over/Under VoltageBattery Over / Under VoltageMains Over / Under VoltageMains Over / Under FrequencyBattery / PV Reverse PolarityInverter Overload / Short CircuitDisplayInverter Voltage & CurrentBattery Voltage & CurrentPV Voltage, Current, GenerationMains Voltage & CurrentCommunicationRS 232 / RS 458 / GPRS based monitoringOperating Temperature0-50 ?C ................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download