ALTEC LRIII-55



HURON-CLINTON METROPOLITAN AUTHORITY

SPECIFICATIONS FOR

Cab and Chassis, with Lift on platform and the attached list of truck components

This truck can be a new or demo with 1000 miles or less. The specifications listed below are general guidelines. The truck furnished under these specifications should be a 33,000 GVWR on the two wheel drive base Unit with an engine in front of the cab type design. It shall have a 60 foot to bottom of platform hydraulic operated, articulating over center aerial device equipped with single platform and mounted on an appropriate chassis/cab. These insulating aerial device requirements shall also include an insulating lower boom, an insulating upper boom and a dielectrically tested insulating control handle. It shall be a Ford F750 or approved equal in accordance with the following general specifications. NOTE: THE BELOW LISTED SPECIFICATIONS ARE A GENERAL GUIDLINE AND are not intended to be restrictive.

This aerial device shall be to the manufacturer’s standard. It shall be equipped with the manufacturer’s equipment and accessories which are included as standard in the advertised and published literature for the unit. No such item of equipment or accessories shall be removed or omitted for the reason that it was not specified in the bid.

| |

| |

|Complies |

| |

|Description |

|Specifications |

|Yes |

|No |

| |

|CHASSIS - BASE UNIT |

| |

|Ford F750 ( or similar meeting these specifications ) : |

| |

| |

| |

| |

|Manufacturer and Model |

| |

|NR |

|NR |

| |

|FRAME |

|Heavy duty (14.85 S.M. @ 120,000 PSI) straight channel w/inverted “L” reinforcement , |

| |

| |

| |

|FRONT BUMBER |

|H.D. standard factory w/cut outs for tow hooks |

| |

| |

| |

|C.A. - APPROX |

|110 inch CA ( CA and wheel base to be as short as possible to allow for shortest turning radius, limited by aerial lift requirements) |

| |

| |

| |

| |

|WHEELBASE |

|175 APPROX |

| |

| |

| |

|ENGINE |

|220HP Diesel, in line 6 |

| |

| |

| |

|ENGINE MAKE AND MODEL |

| |

| |

| |

| |

|Emissions system |

|EGR or SCR |

|EGR |

|□ |

|SGR |

|□ |

|NR |

|NR |

| |

|ENGINE ASSESSORIES |

|Block Heater |

| |

| |

| |

| |

|Diagnostics |

|Dealer to provide software for diagnostic system |

| |

| |

| |

|TRANSMISSION |

|Automatic Allison Model 2500 Series 5 Speed with Low Gear or Equal |

| |

| |

| |

|TRANSMISSION MAKE AND MODEL |

| |

| |

| |

| |

|TRANSMISSION FLUID |

|FULL SYNTHETIC |

| |

| |

| |

|DIFFERENCIAL TYPE |

| |

|Locking Rear Differential |

| |

| |

| |

| |

|P.T.O. |

|Transmission Mount, hot shift type |

| |

| |

| |

|POWER TAKE OFF MAKE AND MODEL |

| |

| |

| |

| |

|GVWR |

|33,000 lbs |

| |

| |

| |

|AXLES FRONT |

|Front: 12,000 lbs |

| |

| |

| |

|REAR |

|Rear: 21,000 lbs |

| |

| |

| |

|SPRINGS CAPACITY |

|To meet above axle requirements |

| |

| |

| |

|TIRES |

|Front: 11:00 x 22.5 14 ply Highway Radial |

|Rear: 11:00 x 22.5 14 ply |

|Off Road Tread – Waste Hauler Lug |

| |

| |

| |

|WHEELS |

|22.5 x 8.25 steel disc 10 hole hub pilot |

| |

| |

| |

|FUEL & HYDRAULIC TANK |

|50 Gallon RH Steel Step Fuel Tank |

|(hydraulic sized for system) |

| |

| |

| |

|SCR |

|Tank sized for over the road driving (If bidding this system) |

| |

| |

| |

|AIR CLEANER |

|Dry type Donaldson or equal |

| |

| |

| |

|AIR COMPRESSOR |

|13.2 cubic feet (Min.) |

| |

| |

| |

|AIR DRYER |

|With auto moisture ejector |

| |

| |

| |

|BRAKES |

|Air Brakes w/ABS System |

| |

| |

| |

| |

|ALTERNATOR |

|110 amp minimum |

| |

| |

| |

|BATTERIES |

|Dual 1300 CCA |

| |

| |

| |

|Battery disconnect |

|Battery disconnect switch (push pull type) mounted exterior drivers side. |

| |

| |

| |

| |

| |

|Body Building Wiring |

|Engine Control Remote Mounted (12VYC) |

| |

| |

| |

|STEERING |

|Power |

| |

| |

| |

|HORN |

|Dual Electric Horns |

| |

| |

| |

| |

|EXHAUST SYSTEM |

|Vertical Exhaust, mounted RH side or to accommodate component and Emission system requirements. |

| |

| |

| |

|RADIATOR |

|HD with coolant recovery |

| |

| |

| |

|COOLING SYSTEM |

|32 qt approx |

| |

| |

| |

|MISC |

|Front Tow Hooks |

| |

| |

| |

|AIR CONDITIONING |

|Factory Installed |

| |

| |

| |

|REAR BUMPER |

|Installed with T100 Pintle Hook |

| |

| |

| |

| |

| |

|TRAILER CONNECTOR |

|6 PRONG FLAT PIN RV TYPE |

| |

| |

| |

|TRAILER BRAKE CONTROLLER |

|Installed in cab to customer specifications |

| |

| |

| |

| |

| |

| |

| |

| |

|CAB |

| |

| |

| |

| |

|TYPE |

|Cab w/tilt one piece fiberglass hood and raised cab roof |

| |

| |

| |

|GAUGES |

|Tachometer and engine alarm, transmission temp, water temp, gas, oil pressure, voltmeter, engine hour-meter, PTO hour meter and out of stow meter |

| |

| |

| |

|GLASS |

|Tinted |

| |

| |

| |

|MIRRORS |

|Stainless Dual Western w/Auxiliary Convex Mirrors, heated w/102 inch arms |

| |

| |

| |

| |

|STANDARD FACTORY EQUIPPED |

|Dual Sun Visor |

| |

| |

| |

| |

|Dual Arm Rests |

| |

| |

| |

| |

|Windshield Mount Rear View Mirror |

| |

| |

| |

| |

|2 Shoulder/Seat Belts |

| |

| |

| |

| |

|HD Dual Bucket Seats, |

| |

| |

| |

| |

|Dome Light |

| |

| |

| |

| |

|Grab Handles, Both Sides |

| |

| |

| |

| |

|Delayed Wipers |

| |

| |

| |

| |

|Maintenance Manuals (2) |

| |

| |

| |

| |

|Spare tire and Wheel – Matching Tread |

| |

| |

| |

| |

|AM/FM Radio |

| |

| |

| |

| |

|Bucket seats |

| |

| |

| |

|EXTERIOR COLOR: |

|Standard White |

| |

| |

| |

| |

|Over-center Aerial Device |

| |

| |

| |

|60-foot Articulating Over-center Aerial Device with an insulating lower boom, insulating upper boom and a dielectrically tested insulating control handle, built in |

|accordance to these standard specifications and to include the following features: |

| |

| |

| |

| |

|COMPLIES |

| |

|DESCRIPTION |

|SPECIFICATIONS |

|YES |

|NO |

| |

|Ground to Bottom of Platform Height: |

|60 feet min. at 3.0 feet (0.9 m) from centerline of rotation |

| |

| |

| |

|Working Height: |

| |

|65 feet min. |

| |

| |

| |

|Minimum Reach to Edge of Platform with Upper Boom Over center: |

|49 feet at 8.4 foot platform height. |

| |

| |

| |

|Minimum Reach to Edge of Platform with Upper Boom Non-over center and Lower Boom at 125 degrees: |

|45 feet at 27.3 foot platform height. |

| |

| |

| |

|Side-by-Side Boom Configuration: |

|Travel height approximately 12’2” on a chassis with approximately 30”-36” frame height. |

| |

| |

| |

|Lower Boom Articulation: |

|0 to 125 degrees (35 degrees beyond vertical) Boom to be equipped with integral holding valves which lock boom in place in the event of a hydraulic line failure and a |

|cushion valve for controlled movement into position at maximum lower boom articulation. |

| |

| |

| |

|Upper Boom Articulation: |

|270 degrees in relation to lower boom. Boom to be equipped with integral holding valves to lock boom in place in the event of hydraulic line failure or loss of power. |

| |

| |

| |

|Pedestal-Subbase: |

|Fabricated from a 16 inch outside diameter x ½ inch (406 x 13 mm) wall steel tube welded into a fabricated steel sub base. Rotation bearing support ring is 1-5/8 inches |

|(41 mm) thick. |

| |

| |

| |

|Lower Boom: |

|Fabricated of 12 x 12 x ¼ inch (305 x 305 x 6 mm) wall steel tubing. Length of lower boom is 278 inches (7061 mm) from centerline of lower pivot to centerline of outer |

|pivot. |

| |

| |

| |

| |

| |

|Lower Boom Fiberglass Insulator: |

| |

|Filament wound fiberglass insulator with 11-3/8 inch square X 5/8 inch (289 x 16 mm) wall thickness, located in lower end of lower boom. Provides 15 inch (381 mm) clear|

|isolation gap |

| |

| |

| |

|Upper Boom: |

|Filament wound fiberglass with 10 inch (254 mm) inside diameter. Boom to contain insulating conduit for routing of hydraulic lines and fully contains upper boom |

|leveling system. End of boom shaft to have ring for attachment of fall protection system lanyard. |

| |

| |

| |

|Rotation: |

| |

|Continuous rotation with extended shaft for manual rotation. All bearing attachment bolts to be accessed from outside the pedestal and inside the turntable. |

| |

| |

| |

|Platform: |

|Molded fiberglass one man side mounted, fiberglass platform with shaft-mounted controls . Platform shall be 24 x 30 x 42 inches (610 x 762 x 1067 mm), and rated at a |

|min. of 350 pounds (159 kg). |

| |

| |

| |

|Mechanical Platform Leveling System: |

|A mechanical leveling system accessible from the lower end of the upper boom and from external location on lower pivot. |

| |

| |

| |

|Platform Tilting System |

| |

| |

| |

| |

| |

|Mechanical pin type |

| |

| |

| |

|Platform Step |

|One step inside and one step outside located on outside wall. In stowed position, step will be side of platform nearest elbow. |

| |

| |

| |

|Platform Cover |

|Soft vinyl, 24 x 30 inches (610 x 762 mm) |

| |

| |

| |

|Pedestal & Sub-base |

|Rear mount. Configuration for forestry package. Pedestal and sub-base welded together. |

| |

| |

| |

|Hydraulic System: |

|Open center hydraulic system. Includes 25 gallon (94.6 l) reservoir, suction strainer, return line filter, sectional control valves and plumbing. Hydraulic fluid to be |

|cold weather hydraulic grade oil. Mil-Spec 5606 or Kendal Glacial Blue or equal |

| |

| |

| |

|Upper Boom Storage Support: |

|Cradle and tie down strap installed. |

| |

| |

| |

|Outrigger/Boom Interlock System: |

|System to prevent boom from being un-stowed until outriggers have been at least partially deployed. |

| |

| |

| |

|Outrigger/Unit Selector Control: |

|Control shall allow operator to divert hydraulic oil from machine circuit for outrigger operation. |

| |

| |

| |

|Outrigger Motion Alarm: |

| |

|Audible alarm when any of the outrigger controls are operated. |

| |

| |

| |

|Back-up Alarm |

| |

|102 dba minimum |

| |

| |

| |

|Vacuum Flashover Protection: |

|As required by ANSI A92.2. |

| |

| |

| |

|Manuals: |

|Two (2) Operator’s and two (2) Maintenance/Parts manuals |

| |

| |

| |

|Paint: |

| |

|Painted white with the Powder Coat Paint Process to match body |

| |

| |

| |

|Tool Circuit |

|Tool Circuit at Boom Tip, Dual Hydraulic – dual set of quick disconnect couplings |

| |

| |

| |

|Remote Functions |

| |

|Engine Start/Stop with Secondary Stowage System, 12 VDC electric powered. Includes pump and motor, operates from chassis battery. Control is captive air operated from |

|the platform and momentary switch operated from the lower controls. |

| |

| |

| |

|Throttle Control |

| |

| |

|Control operated from the platform and momentary switch operated from the lower controls. |

| |

| |

| |

|Outriggers |

|Two sets of outriggers required for rear mount application. One set mounted at the rear of the pedestal and the other mounted behind cab of truck. Controls to be mounted|

|on either side of rear above bumper. Valves and fittings are to be shielded from mud and road salt. |

| |

| |

| |

|Dielectric Rating |

| |

| |

|Category B or C, 46kV and below. |

| |

| |

| |

|Manufacturer and Model |

| |

|NR |

|NR |

| |

|ADDITIONAL OPTIONS |

| |

| |

|YES |

|NO |

| |

|Fall Protection System |

|To include one body harness and decelerating type lanyard. Harness has adjustable slide buckle on shoulder straps, Velcro chest strap, interlocking buckles on leg |

|straps and nylon web loop fall arrest attachment on back. Lanyard to have built in shock absorber. |

| |

| |

| |

|Shut-Off Valve |

|Located at return filter |

| |

| |

| |

|Hydraulic Power Pole Saw |

|Included |

| |

| |

| |

|Make and Model |

| |

|NR |

|NR |

| |

|Holders, Chain Saw and Pole Paw / Pole Pruner |

|Plastic construction for mounting on platform and upper boom. |

| |

| |

| |

|Sight and Temperature Gauge for hydraulic reservoir |

| |

|Included |

| |

| |

| |

|Hot Shift PTO for automatic transmission. |

| |

| |

| |

|See above specs for cab and chassis |

| |

| |

| |

|Make and Model |

| |

|NR |

|NR |

| |

|body and accessories |

| |

| |

|YES |

|NO |

| |

|GENERAL CONSTRUCTION |

|All components, except structural members, fabricated from A-40 galvanneal coated steel. |

| |

| |

| |

| |

|BODY |

|The truck body shall be a flat bed with approximate dimensions of 12’6” long by 8’ wide extending from the tool boxes to the rear of the truck. Construction of bed |

|shall consist of 7 inch structural longsills,with 4 inch structural cross members on 12 inch centers, with 6 inch structural side and end rails. |

| |

| |

| |

| |

| |

|BED CONSTRUCTION |

|The flat bed shall have seven gauge outside stake pockets on 24 inch centers with 3/8’’ x 2-1/2’’ banding strip around perimeter of bed with 3M company red and white |

|(diamond grade) truck conspicuity sheeting applied. The flooring shall be 3/16’’ steel tread plate with anti-slip paint applied. |

| |

| |

| |

| |

| |

| |

| |

|Two (2) 30’’L X 44’’H X19’’ deep side boxes shall be installed one recessed into each side of the platform body behind the cab of truck. The boxes shall be constructed |

|of 12 gauge steel with 3/16” tread plate tops (tops also painted with anti- slip paint). Each box shall have a single door each with twist type locking latches, double |

|acting spring type door holders and rain deflectors above doors. The curb side box shall have four (4) swivel hooks and the street side box shall have two (2) |

|adjustable shelves. |

| |

| |

| |

|Body Make and Model |

| |

| |

| |

| |

|CAB GUARD |

|Construction shall be of 2’’square tubing with 3/16’’ wall covered with 1-1/2’’ number 9 expanded metal from the front of the cab to the flatbed behind the cab. |

|Upright supports on the front shall be tied into a channel that runs across the front bumper. The back upright shall be tied into the cross member of the body. All |

|corners shall be gusseted for additional strength. |

| |

| |

| |

| |

|BUMPER |

|Bumper - Rear bumper shall be constructed of 12’’ gripstrut with a secondary 18’’ wide step mounted on either side hung with a somewhat flexible material such as |

|hydraulic hose or heavy rubber strapping. An additional step may be required depending on distance between bumper and truck bed. Grab rails shall be installed on at |

|least one side of each truck bed access point. Tow hooks shall be installed, Two (2) front and two (2) |

|Rear. Hooks shall be mounted securely to frame of truck. |

| |

| |

| |

| |

| |

| |

|BODY & CHASSIS ACCESSORIES |

| |

|COMPLIES |

| |

| |

| |

| |

|YES |

|NO |

| |

|Side Access Stairway- |

| |

| |

|. |

| |

| |

|A 24’’ wide side access stairway complete with grab handles and stair lights (quantity 2) shall be installed located directly behind tool box on curbside of platform |

|body. |

| |

| |

| |

|Outrigger Pad and Wheel Chock Carriers-- |

|Holders for two (2) sets of outrigger pads and two (2) sets of wheel chocks shall be installed. |

| |

| |

| |

|PADS |

|Pads and chocks are to be furnished with unit |

| |

| |

| |

|Body leveling pointers both directions. |

|Installed |

| |

| |

| |

|Manual Pouch |

|Installed in cab. |

| |

| |

| |

|Fire extinguisher |

|2.5 Lb. Installed in cab. |

| |

| |

| |

|LED strobe lights |

|Install front and rear of vehicle Front on gab guard |

| |

| |

| |

|spare wheel |

|Install mount behind cab |

| |

| |

| |

|Mud fLAPS |

|Installed |

| |

| |

| |

|Triangle reflector kit |

|Included |

| |

| |

| |

|road cone holder |

|Install behind cab. |

| |

| |

| |

|heavy duty stairway with grab rail |

|Install on to platform |

| |

| |

| |

|two speed throttle with momentary switch |

|Install for installation near outrigger controls |

| |

| |

| |

|Power Distribution Module |

| |

|Installed |

| |

| |

| |

|Hour meters |

|Installed to record PTO operating hours, engine hours and out of stow hours. |

| |

| |

| |

|in-cab accessory switch panel |

|Includes dual lit switches for function identification and function activation |

| |

| |

| |

|safety regulations. |

| |

|Body, steps and stepping surfaces must be built according to all applicable safety regulations. |

| |

| |

| |

| |

| |

| |

|FINISHING DETAILS |

| |

| |

| |

| |

|COPLIES |

| |

| |

|YES |

|NO |

| |

|Install aerial device |

| |

| |

| |

|Mounting body and accessories |

| |

| |

| |

|Painting body and accessories white with urethane enamel / Decals per specs |

| |

| |

| |

|Paint cab guard black |

| |

| |

| |

|Paint underneath black |

| |

| |

| |

|Ferrox applied to all walking surfaces. |

| |

| |

| |

|Safety and instructional signs installed |

| |

| |

| |

|Vehicle height placard is to be placed in view of the driver |

| |

| |

| |

|Delivery of completed vehicle |

| |

| |

| |

|DOT certification of completed vehicle |

| |

| |

| |

|Test complete unit in accordance with OSHA/ANSI requirements and provide documentation. |

| |

| |

| |

|MISCELLANEOUS |

| |

| |

|RESPONSE TO WARRNTY IN THE AREAS LISTED BELOW |

| |

|Minimum One (1) year parts warranty |

| |

| |

| |

|Minimum One (1) year labor warranty |

| |

| |

| |

|Minimum 90 day travel warranty |

| |

| |

| |

|Bidder is to supply a self-directed, computer based training (CBT) program. This program will provide basic instruction in the safe operation of this aerial device. |

|This program will also include and explain ANSI and OSHA requirements related to the proper use and operation of this unit. |

| |

| |

USE OF OTHER NAMES AND REFERENCES:

Unless otherwise stated, the use of manufacturer’s name and product numbers are for descriptive purposes and establishing general quality levels only. They are not intended to be restrictive. Bidders are required to state exactly what they intend to furnish, otherwise, it is fully understood that they shall furnish all items stated.

BROCHURES AND LITERATURE:

Your proposal must be accompanied by descriptive literature (marked), indicating the exact items to be furnished. The term “as specified” will not be acceptable.

NOTE TO CAB AND CHASSIS DEALER:

It is preferred that the cab have bucket seats, However if it is not possible, seating must be designed to accommodate all controls.

CAB AND CHASSIS must accommodate all body components including utility boxes and lift mechanism

Dealer must be located in a 100 mile radius of the Brighton, Michigan area.

Note: Exceptions to above specifications must be clearly stated in the area provided below.

EXCEPTIONS: ____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

................
................