Manufactured Gravel Stops and Fasciae - Home | Metal-Era



Metal-Era, Inc.March 20181600 Airport RoadWaukesha, Wisconsin 53188Phone800-558-2162Fax800-373-9156WebsiteEmailinfo@Guide SpecificationSpecifier Notes: This guide specification is written in Construction Specifications Institute (CSI) 3-Part Format in accordance with The CSI Construction Specifications Practice Guide, MasterFormat, SectionFormat, and PageFormat.This Section must be carefully reviewed and edited by the Architect to meet the requirements of the Project and local building code. Coordinate this Section with Division 01, other specification sections, and the Drawings. Delete all Specifier Notes after editing this Section.Section numbers and titles are based on MasterFormat 2016 Edition. 07 71 19MANUFACTURED GRAVEL STOPS AND FASCIAESpecifier Notes: This Section covers Metal-Era, Inc. fasciae, drip edges, and gravel stops. Consult Metal-Era, Inc. for assistance in editing this Section as required for the Project.GENERALSECTION INCLUDESSpecifier Notes: List the materials specified in this Section. Delete materials not specified.Fasciae.Fasciae with wood nailer alternative.Drip edges.Drip edges with wood nailer alternative.Gravel stops.Wood nailer alternative.RELATED REQUIREMENTSSpecifier Notes: Edit the following list of related sections as required for the Project. Limit the list to sections with specific information that the reader might expect to find in this Section, but is specified elsewhere.Section 07 92 00 – Joint Sealants.REFERENCE STANDARDSSpecifier Notes: List reference standards used elsewhere in this Section, complete with designations and titles. Delete reference standards from the following list not used in the edited Section.Factory Mutual (FM Global) ():FM 1-49 – Perimeter Flashing.Florida Building Code.Miami-Dade County, Florida Notice of Acceptance (NOA).Single Ply Roofing Industry (SPRI) ():ANSI/SPRI/FM 4435/ES-1 – Wind Design Standard for Edge Systems Used with Low Slope Roofing Systems.PREINSTALLATION MEETINGSSpecifier Notes: Edit the Preinstallation Meetings article as required for the Project. Delete article if not required.Convene preinstallation meeting [1 week] [2 weeks] before start of installation of materials.Require attendance of parties directly affecting Work of this Section, including Contractor, Architect, installer, and manufacturer’s representative.Review the Following:Materials.Installation.Adjusting.Cleaning.Protection.Coordination with other Work.SUBMITTALSSpecifier Notes: Edit the Submittals article as required for the Project. Delete submittals not ply with Division 01.Product Data: Submit manufacturer’s product data, including installation instructions.Shop Drawings: Submit manufacturer’s shop drawings, including plans, elevations, sections, and details, indicating dimensions, materials, components, fasteners, finish, and accessories.Samples: Submit manufacturer’s sample of materials.Sample Length: Minimum 5-1/2 inches (140 mm).Color Samples: Submit manufacturer’s color samples of materials, consisting of complete color chart representing manufacturer’s full range of available colors.Specifier Notes: Include the following sentence as required for the Project. Delete if not required.Submit metal chips of specific colors as requested by the Architect.Manufacturer’s Certification: Submit manufacturer’s certification that materials comply with specified requirements and are suitable for intended application.Warranty Documentation: Submit manufacturer’s standard warranty.QUALITY ASSURANCEManufacturer’s Qualifications: Manufacturer regularly engaged in the manufacturing of materials of similar type to that specified for a minimum of 10 years.Installer's Qualifications:Installer regularly engaged in installation of materials of similar type to that specified for a minimum of 5 years.Use persons trained for installation of materials of similar type to that specified following manufacturer’s installation instructions.Testing: Meet specified testing requirements.DELIVERY, STORAGE, AND HANDLINGDelivery Requirements: Deliver materials to site in manufacturer’s original, unopened containers and packaging.Storage and Handling Requirements:Store and handle materials in accordance with manufacturer’s instructions.Keep materials in manufacturer’s original, unopened containers and packaging until installation.Store materials in clean, dry area indoors.Do not store materials directly on floor or ground.Protect materials and finish during storage, handling, and installation to prevent damage.WARRANTYSpecifier Notes: Include warranty period for the materials and finish specified. Edit the following as required for the Project.In addition to the limited 30-year finish warranty, other finish warranty periods are available. Consult Metal-Era, Inc. for warranty period information for custom post-coated Kynar 500 colors and for anodized finishes.Warranty Period, Product:Wind, 215 mph: Lifetime.Wind, 120 mph: 20 years.Wind, 90 mph: 10 years.Five-year workmanship warranty covering replacement or repair of products that are defective in material or workmanship.Warranty Period, Finish: Limited 30-year warranty for prefinished coil-coated steel and aluminum coated with Kynar 500 standard colors covering fade, chalk, and film integrity.PRODUCTSMANUFACTURERSManufacturer: Metal-Era, Inc., 1600 Airport Road, Waukesha, Wisconsin 53188. Phone 800-558-2162. Fax 800-373-9156. . info@.Specifier Notes: Specify if substitutions will be permitted.Substitutions: [Not permitted] [Comply with Division 01].Specifier Notes: Specify Metal-Era, Inc. fasciae, drip edges, and gravel stops as required for the Project. Delete materials not required.Consult Metal-Era, Inc. for radius fascia, fascia miter, fascia extender, and factory-fabricated accessory details. Consult Metal-Era, Inc. for custom capabilities.MANUFACTURED FASCIAEFascia: Metal-Era “Anchor-Tite” standard fascia, fully adhered or mechanically attached, single-ply version.Specifier Notes: Specify model. Delete models not required.Model: [AF-40, 4-inch (102-mm) face height] [AF-55, 5-1/2-inch (140-mm) face height] [AF-70, 7-inch (178-mm) face height] [AF-85, 8-1/2-inch (216-mm) face height].Specifier Notes: Specify one of the following four applications.Without Parapet Wall, Wood Nailer Application:Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approvals:FM: ________ perimeter rating and ________ corner rating for wind uplift protection.Miami-Dade County, Florida.Parapet Wall, Wood Nailer Application:Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approvals:FM: ________ perimeter rating and ________ corner rating for wind uplift protection.Miami-Dade County, Florida.Parapet Wall, Alternate Wood Nailer Application:Specifier Notes: Fill in values for FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Parapet Wall, Masonry Application:Specifier Notes: Fill in value for ES-1 design pressure rating. Value can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [____________].Anchor Bar: Extruded aluminum.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) on center.Anchor Bar Splice Plates: EPDM.Fascia: Metal-Era “Anchor-Tite” standard fascia, built-up or modified version.Specifier Notes: Specify model. Delete models not required.Model: [AFM-55, 5-1/2-inch (140-mm) face height] [AFM-70, 7-inch (178-mm) face height] [AFM-85, 8-1/2-inch (216-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approvals:FM: ________ perimeter rating and ________ corner rating for wind uplift protection.Miami-Dade County, Florida.Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [____________].Anchor Bar: Extruded aluminum.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) on center.Anchor Bar Splice Plates: EPDM.Fascia: Metal-Era “Anchor-Tite HG” fascia, fully adhered or mechanically attached, single-ply version.Specifier Notes: Specify model. Delete models not required.Model: [HG-AF-40, 4-inch (102-mm) face height] [HG-AF-55, 5-1/2-inch (140-mm) face height] [HG-AF-70, 7-inch (178-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Concealed splice plates.Anchor Bar: Extruded aluminum.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) on center.Anchor Bar Splice Plates: EPDM.Fascia: Metal-Era “Anchor-Tite HG” fascia, built-up or modified version.Specifier Notes: Specify model. Delete model not required.Model: [HG-AFM-55, 5-1/2-inch (140-mm) face height] [HG-AFM-70, 7-inch (178-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Concealed splice plates.Anchor Bar: Extruded aluminum.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) on center.Anchor Bar Splice Plates: EPDM.Fascia: Metal-Era “Anchor-Tite” extended fascia, fully adhered or mechanically attached, single-ply version.Specifier Notes: Specify model. Delete models not required.Model: [AEF-85, 8-1/2-inch (216-mm) face height] [AEF-100, 10-inch (254-mm) face height] [AEF-115, 11-1/2-inch (292-mm) face height] [AEF-130, 13-inch (330-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approvals:FM: ________ perimeter rating and ________ corner rating for wind uplift protection.Miami-Dade County, Florida.Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Concealed splice plates.Anchor Bar: Extruded aluminum.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 24 inches (610 mm) on center.Continuous Cleats: 20-gauge (0.91-mm) galvanized steel.Anchor Bar Splice Plates: EPDM.Fascia: Metal-Era “Anchor-Tite” extended fascia, built-up or modified version.Specifier Notes: Specify model. Delete models not required.Model: [AEFM-85, 8-1/2-inch (216-mm) face height] [AEFM-100, 10-inch (254-mm) face height] [AEFM-115, 11-1/2-inch (292-mm) face height] [AEFM-130, 13-inch (330-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approvals:FM: ________ perimeter rating and ________ corner rating for wind uplift protection.Miami-Dade County, Florida.Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Concealed splice plates.Anchor Bar: Extruded aluminum.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 24 inches (610 mm) on center.Continuous Cleats: 20-gauge (0.91-mm) galvanized steel.Anchor Bar Splice Plates: 3-1/2-inch (89-mm) width, EPDM.Fascia: Metal-Era “Anchor-Tite” canted fascia, galvanized waterdam version.Specifier Notes: Specify model. Delete model not required.Model: [AEFC-552, 5-1/2-inch (140-mm) face height] [AEFC-752, 7-1/2-inch (191-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approvals:FM: ________ perimeter rating and ________ corner rating for wind uplift protection.Miami-Dade County, Florida.Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Concealed splice plates.Anchor Bar: Extruded aluminum.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 6 inches (152 mm) on center.Waterdam: 24-gauge (0.65-mm) galvanized steel.Anchor Bar Splice Plates: 3-1/2-inch (89-mm) width, 0.040-inch (1.01-mm) mill aluminum.Fascia: Metal-Era “Anchor-Tite” canted fascia, existing beveled wood nailer version.Specifier Notes: Specify model. Delete model not required.Model: [AEFC-55, 5-1/2-inch (140-mm) face height] [AEFC-75, 7-1/2-inch (191-mm) face height].Specifier Notes: Fill in value for ES-1 design pressure rating. Value can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: Miami-Dade County, Florida.Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Concealed splice plates.Anchor Bar: Extruded aluminum.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 6 inches (152 mm) on center.Anchor Bar Splice Plates: 3-1/2-inch (89-mm) width, 0.040-inch (1.01-mm) mill aluminum.Fascia: Metal-Era “Anchor-Tite” extended canted fascia, existing beveled wood nailer version.Specifier Notes: Specify model. Delete models not required.Model: [AEFC-900, 9-inch (229-mm) face height] [AEFC-1050, 10-1/2-inch (267-mm) face height] [AEFC-1200, 12-inch (305-mm) face height] [AEFC-1350, 13-1/2-inch (343-mm) face height].Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Concealed splice plates.Anchor Bar: Extruded aluminum.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 24 inches (610 mm) on center.Continuous Cleats: 20-gauge (0.91-mm) galvanized steel.Anchor Bar Splice Plates: 3-1/2-inch (89-mm) width, 0.040-inch (1.01-mm) mill aluminum.Fascia: Metal-Era “Anchor-Tite” extended canted fascia, galvanized waterdam version.Specifier Notes: Specify model. Delete models not required.Model: [AEFC-902, 9-inch (229-mm) face height] [AEFC-1052, 10-1/2-inch (267-mm) face height] [AEFC-1202, 12-inch (305-mm) face height] [AEFC-1352, 13-1/2-inch (343-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approvals:FM: ________ perimeter rating and ________ corner rating for wind uplift protection.Miami-Dade County, Florida.Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Concealed splice plates.Anchor Bar: Extruded aluminum.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 24 inches (610 mm) on center.Continuous Cleats: 20-gauge (0.91-mm) galvanized steel.Waterdam: 24-gauge (0.65-mm) galvanized steel, slots 6 inches (152 mm) on center.Anchor Bar Splice Plates: 3-1/2-inch (89-mm) width, 0.040-inch (1.01-mm) mill aluminum.Fascia: Metal-Era “Perma-Tite System 200” fascia, single-ply application, snap-on version.Specifier Notes: Specify model. Delete models not required.Model: [FA-50, 5-1/4-inch (133-mm) face height] [FA-65, 6-3/4-inch (171-mm) face height] [FA-80, 8-1/4-inch (210-mm) face height] [FA-95, 9-3/4-inch (248-mm) face height] [FA-110, 11-1/4-inch (286-mm) face height] [FA-125, 12-3/4-inch (324-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover materials not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Concealed splice plates.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 6 inches (152 mm) on center.Spring Clips: 4-inch (102-mm) width, 0.020-inch (0.508-mm) stainless steel, at 4’-0” (1.22 m) on center.Waterdam: 24-gauge (0.65-mm) galvanized steel.Fascia: Metal-Era “Perma-Tite System 200” fascia, single-ply application, crimp-on version.Specifier Notes: Specify model. Delete models not required.Model: [FA-50, 5-inch (127-mm) face height] [FA-65, 6-1/2-inch (165-mm) face height] [FA-80, 8-inch (203-mm) face height] [FA-95, 9-1/2-inch (241-mm) face height] [FA-110, 11-inch (279-mm) face height] [FA-125, 12-1/2-inch (318-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover materials not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Concealed splice plates.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 6 inches (152 mm) on center.Waterdam: 24-gauge (0.65-mm) galvanized steel.Fascia: Metal-Era “Perma-Tite System 300” fascia, built-up or modified application, snap-on version.Specifier Notes: Specify model. Delete models not required.Model: [FA-350, 5-1/4-inch (133-mm) face height] [FA-365, 6-3/4-inch (171-mm) face height] [FA-380, 8-1/4-inch (210-mm) face height] [FA-395, 9-3/4-inch (248-mm) face height] [FA-3110, 11-1/4-inch (286-mm) face height] [FA-3125, 12-3/4-inch (324-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover materials not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Concealed splice plates.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 6 inches (152 mm) on center.Spring Clips: 4-inch (102-mm) width, 0.020-inch (0.508-mm) stainless steel, at 4’-0” (1.22 m) on center.Waterdam: 24-gauge (0.65-mm) galvanized steel.Fascia: Metal-Era “Creative Design Series” bullnose fascia, fully adhered or mechanically attached, single-ply version.Specifier Notes: Specify model. Delete models not required.Model: [BAF-55, 5-1/2-inch (140-mm) face height] [BAF-70, 7-inch (178-mm) face height] [BAF-85, 8-1/2-inch (216-mm) face height].Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [____________].Formed Lengths: 4’-0” (1.22 m).Anchor Bar: Extruded aluminum.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) on center.Support Clips: 4-inch (102-mm) width, 20-gauge (0.91-mm) galvanized steel, at 4’-0” (1.22 m) on center.Anchor Bar Splice Plates: EPDM.Fascia: Metal-Era “Creative Design Series” bullnose fascia, built-up or modified version.Specifier Notes: Specify model. Delete models not required.Model: [BAFM-55, 5-1/2-inch (140-mm) face height] [BAFM-70, 7-inch (178-mm) face height] [BAFM-85, 8-1/2-inch (216-mm) face height].Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [____________].Formed Lengths: 4’-0” (1.22 m).Anchor Bar: Extruded aluminum.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) on center.Support Clips: 4-inch (102-mm) width, 20-gauge (0.91-mm) galvanized steel, at 4’-0” (1.22 m) on center.Anchor Bar Splice Plates: EPDM.Fascia: Metal-Era “Creative Design Series” cornice fascia, fully adhered or mechanically attached, single-ply version.Specifier Notes: Specify model. Delete models not required.Model: [AEF-CS85, 8-1/2-inch (216-mm) face height] [AEF-CS100, 10-inch (251-mm) face height] [AEF-CS115, 11-1/2-inch (292-mm) face height] [AEF-CS130, 13-inch (330-mm) face height].Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Formed Lengths: 4’-0” (1.22 m).Anchor Bar: Extruded aluminum.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 24 inches (610 mm) on center.Continuous Cleats: 20-gauge (0.91-mm) galvanized steel.Anchor Bar Splice Plates: EPDM.Fascia: Metal-Era “Creative Design Series” cornice fascia, built-up or modified version.Specifier Notes: Specify model. Delete models not required.Model: [AEFM-CS85, 8-1/2-inch (216-mm) face height] [AEFM-CS100, 10-inch (251-mm) face height] [AEFM-CS115, 11-1/2-inch (292-mm) face height] [AEFM-CS130, 13-inch (330-mm) face height].Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Formed Lengths: 4’-0” (1.22 m).Anchor Bar: Extruded aluminum.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 24 inches (610 mm) on center.Continuous Cleats: 20-gauge (0.91-mm) galvanized steel.Anchor Bar Splice Plates: EPDM.Fascia: Metal-Era “Creative Design Series” shadow-line fascia, fully adhered or mechanically attached, single-ply version.Specifier Notes: Specify model. Delete models not required.Model: [AEF-SL85, 8-1/2-inch (216-mm) face height] [AEF-SL100, 10-inch (251-mm) face height] [AEF-SL115, 11-1/2-inch (292-mm) face height] [AEF-SL130, 13-inch (330-mm) face height].Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Anchor Bar: Extruded aluminum.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 24 inches (610 mm) on center.Continuous Cleats: 20-gauge (0.91-mm) galvanized steel.Anchor Bar Splice Plates: EPDM.Fascia: Metal-Era “Creative Design Series” shadow-line fascia, built-up or modified version.Specifier Notes: Specify model. Delete models not required.Model: [AEFM-SL85, 8-1/2-inch (216-mm) face height] [AEFM-SL100, 10-inch (251-mm) face height] [AEFM-SL115, 11-1/2-inch (292-mm) face height] [AEFM-SL130, 13-inch (330-mm) face height].Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Anchor Bar: Extruded aluminum.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 24 inches (610 mm) on center.Continuous Cleats: 20-gauge (0.91-mm) galvanized steel.Anchor Bar Splice Plates: EPDM.Fascia: Metal-Era “Edge Systems One: One Edge” fascia, fully adhered or mechanically attached, single-ply version.Specifier Notes: Specify model. Delete models not required.Model: [ESE-S40, 4-inch (102-mm) face height] [ESE-S50, 5-inch (127-mm) face height] [ESE-S65, 6-1/2-inch (165-mm) face height] [ESE-S80, 8-inch (203-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover materials not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) on center.Spring Clips: 6-inch (152-mm) width, stainless steel, at 4’-0” (1.22 m) on center.Formed Rails: 20-gauge (0.91-mm) galvanized steel.Fascia: Metal-Era “Edge Systems One: One Edge” fascia, built-up or modified version.Specifier Notes: Specify model. Delete models not required.Model: [ESE-M50, 5-inch (127-mm) face height] [ESE-M65, 6-1/2-inch (165-mm) face height] [ESE-M80, 8-inch (203-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover materials not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) on center.Spring Clips: 6-inch (152-mm) width, stainless steel, at 4’-0” (1.22 m) on center.Formed Rails: 20-gauge (0.91-mm) galvanized steel.Base Rail Splice Plates: 6-inch (152-mm) width, 24-gauge (0.65-mm) galvanized steel.Fascia: Metal-Era “Edge Systems One: One Edge” fascia, stone ballast, single-ply version.Specifier Notes: Specify model. Delete models not required.Model: [ESE-B50, 5-inch (127-mm) face height] [ESE-B65, 6-1/2-inch (165-mm) face height] [ESE-B80, 8-inch (203-mm) face height].Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) on center.Spring Clips: 6-inch (152-mm) width, stainless steel, at 4’-0” (1.22 m) on center.Formed Rails: 20-gauge (0.91-mm) galvanized steel.Fascia: Metal-Era “Edge Systems One: One Edge” extended fascia, fully adhered or mechanically attached, single-ply version.Specifier Notes: Specify model. Delete models not required.Model: [ESE-S95, 9-1/2-inch (241-mm) face height] [ESE-S110, 11-inch (279-mm) face height] [ESE-S125, 12-1/2-inch (318-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Concealed splice plates.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 24 inches (610 mm) on center.Spring Clips: 6-inch (152-mm) width, stainless steel, at 4’-0” (1.22 m) on center.Formed Rails: 20-gauge (0.91-mm) galvanized steel.Fascia: Metal-Era “Edge Systems One: One Edge” extended fascia, built-up or modified version.Specifier Notes: Specify model. Delete models not required.Model: [ESE-M95, 9-1/2-inch (241-mm) face height] [ESE-M110, 11-inch (279-mm) face height] [ESE-M125, 12-1/2-inch (318-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 24 inches (610 mm) on center.Spring Clips: 6-inch (152-mm) width, stainless steel, at 4’-0” (1.22 m) on center.Formed Rails: 20-gauge (0.91-mm) galvanized steel.Splice Plates: 24-gauge (0.65-mm) galvanized steel.Fascia: Metal-Era termination bar fascia, 1-slot version, with formed 0.080-inch (2-mm) bar.Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) on center.Termination Bars: 0.080-inch (2-mm) formed aluminum.Fascia: Metal-Era termination bar fascia, 2-slot version, with formed 0.080-inch (2-mm) bar.Specifier Notes: Specify face height. Minimum 5 inches (127 mm). Maximum 8-1/2 inches (216 mm).Face Height: _____ inches (_____ mm).Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 24 inches (610 mm) on center.Termination Bars: 0.080-inch (2-mm) formed aluminum.MANUFACTURED FASCIAE WITH WOOD NAILER ALTERNATIVESpecifier Notes: Specify the following fasciae with “Eliminailer-T” wood nailer alternative when using rigid polyiso roof insulation 1-1/2 to 2 inches (38 to 51 mm) thick, for installation on masonry or metal deck applications.Fascia: Metal-Era “Anchor-Tite” canted fascia with “Eliminailer-T”, galvanized formed cant version, without wood nailer.Specifier Notes: Specify model. Delete models not required.Model: [AEFC-552, 5-1/2-inch (140-mm) face height] [AEFC-752, 7-1/2-inch (191-mm) face height] [AEFC-852, 8-1/2-inch (216-mm) face height] [AEFC-1052, 10-inch (254-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approvals:FM: ________ perimeter rating and ________ corner rating for wind uplift protection.Miami-Dade County, Florida.Specifier Notes: Specify cover material. Delete cover materials not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [22-gauge (0.81-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Concealed splice plates.Anchor Bar: Extruded aluminum.Formed Cant: 24-gauge (0.65-mm) galvanized steel.Retainer Clips: 4-inch (102-mm) width, 24-gauge (0.65-mm) galvanized steel, 6’-0” (1,829 mm) on center.Splice Plates: 3-1/2-inch (89-mm) width, 0.040-inch (1.01-mm) mill aluminum.Wood Nailer Alternative: “Eliminailer-T”.Tested: ANSI/SPRI/FM 4435/ES-1 to 600 pliance: FM 1-49.Material: 0.080-inch (2.02-mm) extruded aluminum, with 9/32-inch (7-mm) by 3/8-inch (10-mm) slotted holes, staggered at 6 inches (152 mm) on center.Extruded Lengths: 12’-0” (3.65 m).Height: 1-1/2 inches (38 mm).Horizontal Roof Flange onto Substrate: 5-1/2 inches (140 mm).Isolation barrier required at locations of dissimilar materials, such as masonry or treated wood.Specifier Notes: Specify the following fasciae with “Eliminailer-T” wood nailer alternative when using rigid polyiso roof insulation 3 to 3-1/2 inches (76 to 89 mm) thick, for installation on masonry or metal deck applications.Fascia: Metal-Era “Anchor-Tite” canted fascia with “Eliminailer-T”, galvanized formed cant version, without wood nailer.Specifier Notes: Specify model. Delete models not required.Model: [AEFC-752, 7-1/2-inch (191-mm) face height] [AEFC-852, 8-1/2-inch (216-mm) face height] [AEFC-1052, 10-inch (254-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approvals:FM: ________ perimeter rating and ________ corner rating for wind uplift protection.Miami-Dade County, Florida.Specifier Notes: Specify cover material. Delete cover materials not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [22-gauge (0.81-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Concealed splice plates.Anchor Bar: Extruded aluminum.Formed Cant: 24-gauge (0.65-mm) galvanized steel.S-Clips: 4-inch (102-mm) width, 24-gauge (0.65-mm) galvanized steel, 6’-0” (1,829 mm) on center.Splice Plates: 3-1/2-inch (89-mm) width, 0.040-inch (1.01-mm) mill aluminum.Wood Nailer Alternative: “Eliminailer-T”.Tested: ANSI/SPRI/FM 4435/ES-1 to 600 pliance: FM 1-49.Material: 0.100-inch (2.54-mm) extruded aluminum, with 9/32-inch (7-mm) by 3/8-inch (10-mm) slotted holes, staggered at 6 inches (152 mm) on center.Extruded Lengths: 12’-0” (3.65 m).Height: 3 inches (76 mm).Horizontal Roof Flange onto Substrate: 5-1/2 inches (140 mm).Isolation barrier required at locations of dissimilar materials, such as masonry or treated wood.Specifier Notes: Specify the following fasciae with “Eliminailer-T” wood nailer alternative when using rigid polyiso roof insulation 5.2 to 5.7 inches (132 to 145 mm) thick, for installation on masonry or metal deck applications.Fascia: Metal-Era “Anchor-Tite” canted fascia with “Eliminailer-T”, galvanized formed cant version, without wood nailer.Specifier Notes: Specify model. Delete models not required.Model: [AEFC-852, 8-1/2-inch (216-mm) face height] [AEFC-1052, 10-inch (254-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approvals:FM: ________ perimeter rating and ________ corner rating for wind uplift protection.Miami-Dade County, Florida.Specifier Notes: Specify cover material. Delete cover materials not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [22-gauge (0.81-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Concealed splice plates.Anchor Bar: Extruded aluminum.Formed Cant: 24-gauge (0.65-mm) galvanized steel.S-Clips: 4-inch (102-mm) width, 24-gauge (0.65-mm) galvanized steel, 6’-0” (1,829 mm) on center.Splice Plates: 3-1/2-inch (89-mm) width, 0.040-inch (1.01-mm) mill aluminum.Wood Nailer Alternative: “Eliminailer-T”.Tested: ANSI/SPRI/FM 4435/ES-1 to 600 pliance: FM 1-49.Material: 0.157-inch (3.99-mm) extruded aluminum, with 9/32-inch (7-mm) by 3/8-inch (10-mm) slotted holes, staggered at 6 inches (152 mm) on center.Extruded Lengths: 12’-0” (3.65 m).Height: 5.2 inches (132 mm).Horizontal Roof Flange onto Substrate: 5-1/2 inches (140 mm).Isolation barrier required at locations of dissimilar materials, such as masonry or treated wood.Specifier Notes: Specify the following fasciae with “Eliminailer-T” wood nailer alternative when using rigid polyiso roof insulation 1-1/2 to 2 inches (38 to 51 mm) thick, for installation on masonry or metal deck applications.Fascia: Metal-Era “Anchor-Tite HG” fascia with “Eliminailer-T”, fully adhered or mechanically attached, single-ply version, without wood nailer.Specifier Notes: Specify model. Delete models not required.Model: [HG-AF-55, 5-1/2-inch (140-mm) face height] [HG-AF-70, 7-inch (178-mm) face height] [HG-AF-85, 8-1/2-inch (216-mm) face height] [HG-AF-100, 10-inch (254-mm) face height]..Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover materials not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [22-gauge (0.81-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Anchor Bar: Extruded aluminum.Splice Plates: 3-1/2-inch (89-mm) width, 0.040-inch (1.01-mm) mill aluminum.Wood Nailer Alternative: “Eliminailer-T”.Tested: ANSI/SPRI/FM 4435/ES-1 to 600 pliance: FM 1-49.Material: 0.100-inch (2.54-mm) extruded aluminum, with 9/32-inch (7-mm) by 3/8-inch (10-mm) slotted holes, staggered at 6 inches (152 mm) on center.Extruded Lengths: 12’-0” (3.65 m).Height: 1-1/2 inches (38 mm).Horizontal Roof Flange onto Substrate: 5-1/2 inches (140 mm).Isolation barrier required at locations of dissimilar materials, such as masonry or treated wood.Specifier Notes: Specify the following fasciae with “Eliminailer-T” wood nailer alternative when using rigid polyiso roof insulation 3 to 3-1/2 inches (76 to 89 mm) thick, for installation on masonry or metal deck applications.Fascia: Metal-Era “Anchor-Tite HG” fascia with “Eliminailer-T”, fully adhered or mechanically attached, single-ply version, without wood nailer.Specifier Notes: Specify model. Delete models not required.Model: [HG-AF-70, 7-inch (178-mm) face height] [HG-AF-85, 8-1/2-inch (216-mm) face height] [HG-AF-100, 10-inch (254-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover materials not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [22-gauge (0.81-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Anchor Bar: Extruded aluminum.Splice Plates: 3-1/2-inch (89-mm) width, 0.040-inch (1.01-mm) mill aluminum.Wood Nailer Alternative: “Eliminailer-T”.Tested: ANSI/SPRI/FM 4435/ES-1 to 600 pliance: FM 1-49.Material: [0.100-inch (2.54-mm)] extruded aluminum, with 9/32-inch (7-mm) by 3/8-inch (10-mm) slotted holes, staggered at 6 inches (152 mm) on center.Extruded Lengths: 12’-0” (3.65 m).Height (choose one): 3 inches (76 mm).Horizontal Roof Flange onto Substrate: 5-1/2 inches (140 mm).Isolation barrier required at locations of dissimilar materials, such as masonry or treated wood.Specifier Notes: Specify the following fasciae with “Eliminailer-T” wood nailer alternative when using rigid polyiso roof insulation 5.2 to 5.7 inches (132 to 145 mm) thick, for installation on masonry or metal deck applications.Fascia: Metal-Era “Anchor-Tite HG” fascia with “Eliminailer-T”, fully adhered or mechanically attached, single-ply version, without wood nailer.Specifier Notes: Specify model. Delete models not required.Model: [HG-AF-85, 8-1/2-inch (216-mm) face height] [HG-AF-100, 10-inch (254-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover materials not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [22-gauge (0.81-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Anchor Bar: Extruded aluminum.Splice Plates: 3-1/2-inch (89-mm) width, 0.040-inch (1.01-mm) mill aluminum.Wood Nailer Alternative: “Eliminailer-T”.Tested: ANSI/SPRI/FM 4435/ES-1 to 600 pliance: FM 1-49.Material: [0.157-inch (3.99-mm)] extruded aluminum, with 9/32-inch (7-mm) by 3/8-inch (10-mm) slotted holes, staggered at 6 inches (152 mm) on center.Extruded Lengths: 12’-0” (3.65 m).Height (choose one): 5.2 inches (132 mm).Horizontal Roof Flange onto Substrate: 5-1/2 inches (140 mm).Isolation barrier required at locations of dissimilar materials, such as masonry or treated wood.MANUFACTURED DRIP EDGESDrip Edge: Metal-Era “Anchor-Tite” drip edge.Specifier Notes: Specify model. Delete model not required.Face Height: [4-1/2 inches (114 mm)] [6 inches (152 mm)] [7-1/2 inches (190 mm)].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [____________].Anchor Bar: Extruded aluminum.Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) on center.Anchor Bar Splice Plates: 3-1/2-inch (89-mm) width, 0.040-inch (1.01-mm) aluminum.Drip Edge: Metal-Era “Edge Systems One: One Drip Edge” drip edge, Kynar version, 1-1/4-inch to 6-inch face height, with continuous cleat version.Specifier Notes: Specify face height. Minimum 1-1/4 inches (32 mm). Maximum 6 inches (152 mm).Face Height: _____ inches (_____ mm).Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover materials not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 6 inches (152 mm) on center.Continuous Cleats: 22-gauge (0.85-mm) galvanized steel.Splice Plates: 6-inch (152-mm) width.Drip Edge: Metal-Era “Edge Systems One: One Drip Edge” drip edge, Kynar version, 6-inch to 10-inch face height, with continuous cleat version.Specifier Notes: Specify face height. Minimum 6 inches (152 mm). Maximum 10 inches (254 mm).Face Height: _____ inches (_____ mm).Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover materials not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 6 inches (152 mm) on center.Continuous Cleats: 22-gauge (0.85-mm) galvanized steel.Splice Plates: 6-inch (152-mm) width.Drip Edge: Metal-Era “Edge Systems One” drip edge, without continuous cleat version.Specifier Notes: Specify face height.Face Height: _____ inches (_____ mm).Specifier Notes: Specify angle.Angle: _____ degrees.Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 6 inches (152 mm) on center.Drip Edge: Metal-Era “Edge Systems One: One Drip Edge” drip edge, TPO version, 12’-0” lengths, with continuous cleat version.Specifier Notes: Specify model. Delete models not required.Model: [3-inch (76-mm) face height] [4-inch (102-mm) face height] [6-inch (152-mm) face height] [_____-inch (_____-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approvals:FM ________ perimeter rating and ________ corner rating for wind uplift protection.Florida Building Code.Specifier Notes: Specify cover material. Delete cover material not required.Cover Material: [24-gauge (0.65-mm) galvanized steel, TPO coated] [24-gauge (0.65-mm) galvanized steel].Specifier Notes: Provide name of membrane roofing manufacturer.Membrane Roofing Manufacturer: _______________.Specifier Notes: Confirm color availability by membrane roofing manufacturer, if other than white.Color: [White] [________].Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 6 inches (152 mm) on center.Continuous Cleats: 22-gauge (0.85-mm) galvanized steel.Drip Edge: Metal-Era “Edge Systems One: One Drip Edge” drip edge, PVC version, 10’-0” lengths, with continuous cleat version.Specifier Notes: Specify model. Delete models not required.Model: [3-inch (76-mm) face height] [4-inch (102-mm) face height] [6-inch (152-mm) face height] [_____-inch (_____-mm) face height].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approvals:FM ________ perimeter rating and ________ corner rating for wind uplift protection.Florida Building Code.Cover Material: 24-gauge (0.65-mm) galvanized steel, PVC coated.Specifier Notes: Confirm color availability by membrane roofing manufacturer, if other than white.Color: [White] [________].Formed Lengths: 10’-0” (3.05 m).Slotted Fastening Holes: 12 inches (305 mm) and 6 inches (152 mm) on center.Continuous Cleats: 22-gauge (0.85-mm) galvanized steel.Drip Edge: Metal-Era “Edge Systems One: One Flash-Through” drip edge, built-up or modified version, with continuous cleat.Specifier Notes: Specify face height.Face Height: _____ inches (_____ mm).Specifier Notes: Fill in values for FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover materials not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and staggered 6 inches (152 mm) on center.Continuous Cleats: 22-gauge (0.85-mm) galvanized steel.Splice Plates: 6-inch (152-mm) width.MANUFACTURED DRIP EDGES WITH WOOD NAILER ALTERNATIVESpecifier Notes: Specify the following drip edge with “Eliminailer-T” wood nailer alternative when using rigid polyiso roof insulation 1-1/2 to 2 inches (38 to 51 mm) thick, for installation on masonry or metal deck applications.Drip Edge: Metal-Era “Anchor-Tite” drip edge with “Eliminailer-T”, without wood nailer.Specifier Notes: Specify face height.Face Height: [4-1/2 inches (114 mm)] [6 inches (152 mm)] [7-1/2 inches (190 mm)].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Lap Joints: 1 inch (25 mm).Anchor Bar: Extruded aluminum.Wood Nailer Alternative: “Eliminailer-T”.Tested: ANSI/SPRI/FM 4435/ES-1 to 600 pliance: FM 1-49.Material: 0.080-inch (2.02-mm) extruded aluminum, with 9/32-inch (7-mm) by 3/8-inch (10-mm) slotted holes, staggered at 6 inches (152 mm) on center.Extruded Lengths: 12’-0” (3.65 m).Height: 1-1/2 inches (38 mm).Horizontal Roof Flange onto Substrate: 5-1/2 inches (140 mm).Isolation barrier required at locations of dissimilar materials, such as masonry or treated wood.Specifier Notes: Specify the following drip edge with “Eliminailer-T” wood nailer alternative when using rigid polyiso roof insulation 3 to 3-1/2 inches (76 to 89 mm) thick, for installation on masonry or metal deck applications.Drip Edge: Metal-Era “Anchor-Tite” drip edge with “Eliminailer-T”, without wood nailer.Specifier Notes: Specify face height.Face Height: [4-1/2 inches (114 mm)] [6 inches (152 mm)] [7-1/2 inches (190 mm)].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Lap Joints: 1 inch (25 mm).Anchor Bar: Extruded aluminum.Wood Nailer Alternative: “Eliminailer-T”.Tested: ANSI/SPRI/FM 4435/ES-1 to 600 pliance: FM 1-49.Material: 0.100-inch (2.54-mm) extruded aluminum, with 9/32-inch (7-mm) by 3/8-inch (10-mm) slotted holes, staggered at 6 inches (152 mm) on center.Extruded Lengths: 12’-0” (3.65 m).Height: 3 inches (76 mm)Horizontal Roof Flange onto Substrate: 5-1/2 inches (140 mm).Isolation barrier required at locations of dissimilar materials, such as masonry or treated wood.Specifier Notes: Specify the following drip edge with “Eliminailer-T” wood nailer alternative when using rigid polyiso roof insulation 5.2 to 5.7 inches (132 to 145 mm) thick, for installation on masonry or metal deck applications.Drip Edge: Metal-Era “Anchor-Tite” drip edge with “Eliminailer-T”, without wood nailer.Specifier Notes: Specify face height.Face Height: [6 inches (152 mm)] [7-1/2 inches (190 mm)].Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Lap Joints: 1 inch (25 mm).Anchor Bar: Extruded aluminum.Wood Nailer Alternative: “Eliminailer-T”.Tested: ANSI/SPRI/FM 4435/ES-1 to 600 pliance: FM 1-49.Material: 0.157-inch (2.02-mm) extruded aluminum, with 9/32-inch (7-mm) by 3/8-inch (10-mm) slotted holes, staggered at 6 inches (152 mm) on center.Extruded Lengths: 12’-0” (3.65 m).Height: 5.2 inches (132 mm)Horizontal Roof Flange onto Substrate: 5-1/2 inches (140 mm).Isolation barrier required at locations of dissimilar materials, such as masonry or treated wood.MANUFACTURED GRAVEL STOPSGravel Stop: Metal-Era “Edge Systems One: One Gravel Stop” gravel stop, 10-inch (254-mm) maximum face height, with continuous cleat version.Specifier Notes: Specify face height. Maximum 10 inches (254 mm).Face Height: _____ inches (_____ mm).Specifier Notes: Specify rise. Minimum 1/2 inch (13 mm).Rise: _____ inches (_____ mm).Specifier Notes: Fill in values for ES-1 design pressure rating and FM perimeter and corner ratings for wind uplift protection. Values can vary with face height and cover material. Consult , , or call Metal-Era, Inc. at 800-558-2162 for information.Tested: ANSI/SPRI/FM 4435/ES-1 to design pressure of ________ psf.Approval: FM ________ perimeter rating and ________ corner rating for wind uplift protection.Specifier Notes: Specify cover material. Delete cover materials not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [0.050-inch (1.27-mm) aluminum] [0.063-inch (1.60-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 12 inches (305 mm) and 6 inches (152 mm) on center.Continuous Cleats: 22-gauge (0.85-mm) galvanized steel.Splice Plates: 6-inch (152-mm) width.Gravel Stop: Metal-Era “Edge Systems One: One Gravel Stop” gravel stop, without continuous cleat version.Specifier Notes: Specify face height.Face Height: _____ inches (_____ mm).Specifier Notes: Specify rise. Minimum 1/2 inch (13 mm).Rise: _____ inches (_____ mm).Specifier Notes: Specify cover material. Delete cover material not required. Consult Metal-Era, Inc. for information regarding other materials.Cover Material: [24-gauge (0.65-mm) galvanized steel] [0.040-inch (1.01-mm) aluminum] [____________].Formed Lengths: 12’-0” (3.65 m).Slotted Fastening Holes: 6 inches (152 mm) on center.WOOD NAILER ALTERNATIVESpecifier Notes: “Eliminailer-T” is used as an alternative to wood nailers at the edge of the roof, for installation on masonry or metal deck applications. Consult Metal-Era, Inc. for more information.Wood Nailer Alternative: “Eliminailer-T” for use with metal deck or masonry wall.Tested: ANSI/SPRI/FM 4435/ES-1 to 600 pliance: FM 1-49.Material: 0.100-inch (2.54-mm) extruded aluminum, with 9/32-inch (7-mm) by 3/8-inch (10-mm) slotted holes, staggered at 6 inches (152 mm) on center.Extruded Lengths: 12’-0” (3.65 m).Specifier Notes: Specify 1-1/2-inch (38-mm) height when using rigid polyiso roof insulation 1-1/2 to 2 inches (38 to 51 mm) thick. Specify 3-inch (76-mm) height when using rigid polyiso roof insulation 3 to 3-1/2 inches (76 to 89 mm) thick. Specify 5.2-inch (76-mm) height when using rigid polyiso roof insulation 5.2 to 5.7 inches (132 to 145 mm) thick.Height: [1-1/2 inches (38 mm)] [3 inches (76 mm)] [5.2 inches (132 mm)].Holes: 9/32-inch (7-mm) by 3/8-inch (10-mm) slotted holes, staggered at 6 inches (152 mm) on center.Horizontal Roof Flange onto Substrate: 5-1/2 inches (140 mm).Isolation barrier required at locations of dissimilar materials, such as masonry or treated wood.FINISHESSpecifier Notes: Specify finish for the materials. Delete finish not required. Consult Metal-Era, Inc. for description of the finishes available for each cover material and for information regarding other finishes.Finish: [Hylar 5000/Kynar 500] [Coil anodized] [____________].Specifier Notes: Specify color. Consult Metal-Era, Inc. for standard and custom colors.Color: ____________.ACCESSORIESSpecifier Notes: Edit the following list of accessories as required for the Project. Delete accessories not required. Consult Metal-Era, Inc. for factory-fabricated accessory details.Factory-Fabricated Accessories:Miters:Outside Miters: [90 degrees] [_____ degrees].Inside Miters: [90 degrees] [_____ degrees].Scuppers:Overflow Scuppers: [Style A] [Style B].Spillout Scuppers: [Style A] [Style B].Downspout Scuppers: [Style A] [Style B].Size: _____ by _____.Endcaps:Right endcaps.Left endcaps.Endwall Flashings:Right endwall flashings.Left endwall flashings.Joint Sealants: Specified in Section 07 92 00.Fasteners: Appropriate for intended substrate.EXECUTIONEXAMINATIONExamine areas to receive materials.Verify surfaces to support materials are clean, dry, straight, secure, and of proper dimensions.Notify Architect of conditions that would adversely affect installation.Do not begin installation until unacceptable conditions are corrected.INSTALLATIONInstall materials in accordance with manufacturer’s instructions at locations indicated on the Drawings.Remove protective vinyl film immediately before installation.Install materials to provide watertight termination at leading edge of roofing material.Install materials to allow for thermal movement.Joint Sealants: Apply joint sealants in accordance with manufacturer’s instructions.ADJUSTINGRepair minor damages to finish in accordance with manufacturer’s instructions and as approved by Architect.Remove and replace with new material, damaged components that cannot be successfully repaired, as determined by Architect.CLEANINGClean materials promptly after installation in accordance with manufacturer’s instructions.Do not use harsh cleaning materials or methods that could damage finish.PROTECTIONProtect installed materials to ensure that, except for normal weathering, materials will be without damage or deterioration at time of Substantial Completion.END OF SECTION ................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download