NFPA 285 Tested Assemblies - Applied Building Tech
Engineering Analysis of NFPA 285 Tested Assemblies
Applied Building Technology Group (ABTG) is committed to using sound science and generally accepted engineering practice to develop research supporting the reliable design and installation of foam sheathing. ABTG's educational program work with respect to foam sheathing is supported by the Foam Sheathing Committee (FSC) of the American Chemistry Council.
ABTG is a professional engineering firm, an approved source as defined in Chapter 2 and independent as defined in Chapter 17 of the IBC.
DISCLAIMER: While reasonable effort has been made to ensure the accuracy of the information presented, the actual design, suitability and use of this information for any particular application is the responsibility of the user. Where used in the design of buildings, the design, suitability and use of this information for any particular building is the responsibility of the Owner or the Owner's authorized agent.
Foam sheathing research reports, code compliance documents, educational programs and best practices can be found at .
Copyright ? 2015 Applied Building Technology Group
Introduction
Foam plastics used in buildings of Types I-IV construction require an assessment of their ability to resist vertical and lateral flame spread
IBC Section 2603.5.5: "The exterior wall assembly shall be tested in accordance with and comply with the acceptance criteria of NFPA 285"
Introduction
? Does this mean that every possible wall assembly configuration needs to be tested to NFPA 285 to be compliant with the code?
Introduction
? What about extension of tested assemblies through engineering analysis?
? Is actual testing required, or is engineering analysis permitted?
? Let's look at the building code requirements
Code Requirements
? First, there are exceptions to the requirement ? Code compliance of fire-rated wall assemblies
IBC Section 2603.5.5:
Code Requirements - Exception #1
? One-story buildings complying with IBC Section 2603.4.1.4
? Flame spread index of 25 or less ? Smoke-developed index of 450 or less ? Foam Plastic Insulating Sheathing (FPIS) not more
than 4" thick ? Equipped with an automatic fire sprinkler system ? FPIS covered with 0.032"-thick aluminum or
0.0160" corrosion-resistant steel
Code Requirements - Exception #2
? FPIS covered by minimum 1" masonry or concrete AND
? No airspace between FPIS and masonry/concrete OR
? Flame spread index less than 25 and airspace a maximum of 1"
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- module 4 type iii or ordinary construction
- type iib type iiib unprotected construction story
- standard on types of building construction
- types of construction type i type ii type iv type v
- types of construction
- nfpa 5000 building construction and safety code
- table of contents wbdg
- nfpa 220 table 4 1 1 fire resistance rating for type i
- nfpa 285 tested assemblies applied building tech
- construction types definitions
Related searches
- 31 cfr 285 4
- house tested for methamphetamine
- nfpa classification of diesel fuel
- 2008 nfpa 58 free download
- what is tested on sat
- trump tested positive for corona
- donald trump tested positive
- cfr 285 11
- applied physics and applied mathematics
- nfpa building construction classification
- date trump tested positive
- how is lupus tested for