WP65L Data Sheet - High Pressure Gas Compressors On Sauer ...



WP3215 COMSILENT N2

BOOSTER DATA SHEET

|WP3215CS Data Sheet Nitrogen Booster Data Sheet |

|  |Final Operating Pressure |Speed | |

| | | |UNITS |

| | |1170 RPM (60 Hz) | |

|Flow &|1450 PSIG Outlet Pressure |6.9-8.9 |SCFM |

|Power |(0 – 4.5 PSIG Regulated Inlet Pressure) | | |

| | |6.2 |HP |

| |2900 PSIG Outlet Pressure |6.5-8.5 |SCFM |

| |(0 – 4.5 PSIG Regulated Inlet Pressure) | | |

| | |6,6 |HP |

| |4000 PSIG Outlet Pressure |6.1-8.0 |SCFM |

| |(0 – 4.5 PSIG Regulated Inlet Pressure) | | |

| | |7.1 |HP |

| |

|Techni|Motor rating |8.5 (6.3 KW) |HP |

|cal | | | |

|Specif| | | |

|icatio| | | |

|ns | | | |

| |Current @ 460 Volts |10 |Amps |

| |Weight |1135 |Pounds |

| |Noise level @ 3 ft |71 |dB(A) |

| |Heat dissipation |20,000 |Btu/hr |

| |Cooling air needed |590 |CFM |

| |Residual oil content at gas outlet (without filtration) |< 3 |mg/m3 |

| |Delta temperature (gas oultet vs. ambient) |18 |°F |

| |Operational ambient temperature range |40-110 |°F |

| |Operating pressure range |1450-4000 |psig |

| |Oil sump capacity |6.1 |Quarts |

| |Dimensions (L x W x H) |60 X 31 X 62 |Inches |

| |Cooling method |Air-Cooled |

| |Drive type |Direct Drive |

| |Stages/Cylinders |3/3 |

* All data is with 5 % tolerance and is related to ambient conditions of 68 ° F and 14.7 PSIA.

Package Includes:

• Feed tank run-permissive sensor (supplied loose)

• Inlet Buffer Tank and Regulator Assembly

• Intercoolers and aftercooler

• Oil and water separators after the 1st, 2nd and 3rd stages

• Safety valve after each stage

• 1st, 2nd, and 3rd stage pressure gauges

• Solenoid valves (115 V / 60 Hz) for automatic drainage of the separators

• Unloaded starting relief and automatic condensate drain system

• Condensate demister to easily dispose of condensate drainage

• Assembly of compressor and electric motor

• Resilient mounts including drainage hoses and air/gas outlet hose

• 460/3/60 electric motor with IP 55 (TEFC) protection

• Non-return valve mounted to air/gas outlet hose

• Low oil pressure shutdown switch

• High air/gas temperature shutdown switch mounted at the air/gas outlet of the compressor

• Final gas filtration for oil free gas delivery

• Compressor control system (including motor starter) for starting/stopping the compressor, and monitoring the oil level, air/gas outlet temperature and outlet pressure of the compressor

• Complete package wired and mounted on a skid, and enclosed in a sound dampening canopy

• Air/gas pressure sensor for automatic start/stop

Standard warranty is 15 months from date of shipment or 12 months after initial installation and start-up, whichever comes first. Ask your Sauer USA representative if your project requires an extended or alternative warranty period.

Sauer Electronic Compressor Control (ECC technology):

Electronic Compressor Control (ECC) advanced embedded control solution:

Mounting Integral

Power: 6.1 HP

Power Supply: 60 Hz / 3Ph

Control voltage: 115 V ac

Disconnect mains supply: Red handle, yellow locking collar

Emergency Stop: Latched pushbutton

Protection: IP 54

Power supply to processor: 24 V ac

Operation:

• AUTO automatic - Start / Stop ( based on suction (feed) and final system pressure)

• HAND manual Start – auto Stop / manual Stop (e.g. Servicing)

Control:

• Compressor solenoid drain valve (NO)

o Auto-unloaded Start (programmable - ‘normal’ 15 s)

o Periodic drainage (programmable - ‘normal dry gas’ every 30 min. for 5 s)

• Feed gas Start / Stop (gas suction pressure sensor control)

• Suction gas solenoid shut-off valve (NC) (open on Start/close on Stop)

• Final system Stop / Start (gas final pressure sensor control)

User Interface:

Custom backlit LCD: 2 LED Indicators

- STATUS: Green

- FAULT: Red

Keypad: 7 tactile push buttons

• START (I) Manual Start

• STOP (O) Manual Stop

• RESET (//) Reset and clear faults

• ESCAPE (C) Step back one level

• MINUS/DOWN (▼) Scroll down menu

• PLUS/UP (▲) Scroll up through menu

• ENTER (◄┘) Confirm selection

Display:

• Operating gas pressure

• Hours run

• Service hours

• Gas temperature

• Oil pressure

Error(s) - shutdown/Alarm/Diagnostics:

• Emergency Stop

• E-Motor over-load

• Low oil lubricating pressure

• Low / high gas suction pressure

• Oil/water (condensate) level alarm

• High gas temperature

• High final gas pressure

• Potential free contact(s)

Optional equipment:

• Final receiver packages with the necessary components supplied

• Diesel motor driven

• Modified for 50 Hz power supply

• Customized controls for user specified monitoring and operation

• Weather resistant canopy

• Complete package rated for installation in a hazardous location (Class 1 Division 2, or Class 1 Division 1)

Sauer Compressors USA custom engineers solutions for our customers. Please inquire about options you may require which are not listed.

-----------------------

245 Log Canoe Circle

Stevensville, Maryland 21666

T 410.604.3142

F 410.604.3209



[pic]

-----------------------

High Quality. High Performance. High Pressure.

................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download