Abbreviations - Bentley
AutoPLANT P&ID Metric ConversionContents TOC \o "1-3" \h \z \u Abbreviations PAGEREF _Toc315160479 \h 1Metric Units PAGEREF _Toc315160480 \h 1Metric Environment “Unit consistency error” or “Primary Repository Units” mismatch PAGEREF _Toc315160481 \h 3Metric Bubbles PAGEREF _Toc315160482 \h 4Tips PAGEREF _Toc315160483 \h 4OpenPlant PowerPID components are too small PAGEREF _Toc315160484 \h 4OpenPlant PowerPID components are too large PAGEREF _Toc315160485 \h 4Valve insert after conversion does not work correctly PAGEREF _Toc315160486 \h 5Bubble are too small or too big PAGEREF _Toc315160487 \h 5I get a Units mismatch dialog error PAGEREF _Toc315160488 \h 5Component Relationships and Project DB Data does not look correct. PAGEREF _Toc315160489 \h 5I do not get the Conversion Dialog PAGEREF _Toc315160490 \h 6Pipeline Annotation does not show correctly PAGEREF _Toc315160491 \h 6AutoPLANT P&ID PAGEREF _Toc315160492 \h 6Optional Metric Scaling PAGEREF _Toc315160493 \h 7AbbreviationsOpenPlant PowerPID = OPPIDMicroStation Drawing extension = DGNAutoPLANT P&ID = APPIDAutoCAD Drawing extension = DWGMetric UnitsAPPID AutoCAD metric drawings are considered unit less in the MicroStation world. When an APPID DWG is opened in OPPID, the “DWG/DXF Units” dialog is shown:This dialog allows the user to select a specific type of Units to be set. Currently the conversion requires that Millimeters to be set. This value is set as a default in the OPPowerPID_Metric.pcf file.#This sets the default unit type for APPID Metric DWG files MS_DWG_DEC_FRC_SCI_UNITS=MillimetersTo hide this dialog, check the following boxTo enable this dialog box, the following must be done.Start an OPPID sessionSelect a DWG file typeSelect Options button in bottom right of Open DialogFrom the Option buttons, expand the “Advanced” nodeFrom “Advanced” node expand the “Display Units Alert”Checkbox the “Unspecified Design Center Units”Metric Environment “Unit consistency error” or “Primary Repository Units” mismatchMetric Drawing in AutoPLANT P&ID have a MicroStation Master System definition of English.This causes issues in the OPPID unit matching logic. This logic is accessed when a drawing is initial opened and an AP Database Project is selected. Currently the only way to bypass this check is to add the following variable to the project.pcf (OPPowerPID_Metric.pcf)PLANT_PROJECT_BYPASS_PRIMARY_UNITS_CHECK=1Dialogs displayed:Metric BubblesBubble values may have to be modified, to accomplish this find and edit cfg variables in the OPPowerPID_Metric.pcfOval bubble elongated lengthALT_OVAL_BUBBLE_WIDTH_SIZE=15.0Regular bubble radiusALT_BUBBLE_SIZE=6.0TipsOpenPlant PowerPID components are too smallThe scale cfg variable was not set in metric workspace project.pcf file.The scale cfg variable needs to be adjusted.The default scale is set too high, try making it smaller.APPID_CONVERT_METRIC_SCALE_VALUE=0.12Check the current OPPID workspace. Ensure it is a metric workspace. OpenPlant PowerPID components are too largeThe scale cfg variable was not set in metric workspace project.pcf file.The scale cfg variable needs to be adjusted.The default scale is set too low, try making it larger.APPID_CONVERT_METRIC_SCALE_VALUE=0.32Check the current OPPID workspace. Ensure it is a metric workspace. Valve insert after conversion does not work correctlyCheck the current OPPID workspace. Ensure it is a metric workspace.The valve break size values are stored in the cell schema xmlC:\ProgramData\Bentley\PowerPID (SELECTseries 5)\WorkSpace\Projects\OPPowerPID_Metric\Dataset\cellValves.cel.sch.ecinstance.xmlThe scale cfg variable was not set in metric workspace project.pcf file.Bubble are too small or too bigThe scale cfg variable needs to be adjusted.Check the current OPPID workspace. Ensure it is a metric workspace.Check the bubble cfg variable in the metric workspace project.pcf file.I get a Units mismatch dialog errorAdded the bypass cfg variable to the project.pcf file.The conversion process must be restarted because a Project DB is ponent Relationships and Project DB Data does not look correct.The conversion process requires the AutoPLANT Project DB. If an incorrect Project DB is used, relationships cannot be established correctly. Relationships between components are stored in the Project DB.If Project DB variables are set in the project.pcf, ensure they are correct.AP_PROJECT_ROOT=c:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\AP_PROJECT_ID=0002If a Project DB is select from the Initialization dialog, ensure it is correctI do not get the Conversion DialogDrawing has already been convertedCheck Bentley.ConversionServices.xml for the AutoPLANT PID conversion class.PromptMode may be turned offPromptMode="falsePipeline Annotation does not show correctlyReference the document APPID Conversion Pipeline Annotation.docxAutoPLANT P&IDThe drawing (DWG) should be metric defined. To determine the APPID environment, from the file menu select Preferences->Drawing Modes. The following dialog should be displayed with Units set to Metric: The drawing parameters will also reflect the scaling. As seen below the Global Scale Factor is set to 12. This indicates all components will be scaled up by 12. Optional Metric ScalingPre-Conversion scaling can be done but is not recommended. If enabled, the entire drawing will be scaled by value in the project.pcf file. This variable goes in the project.pcf file (OPPowerPID_Metric.pcf). The APPID drawing will be scaled depending on this numeric value.APPID_CONVERT_METRIC_SCALE_VALUE=0.20The Grid display is also affected by this. To compensate for this add this cfg variable to the project.pcf. This value sets the GridUnit valueAPPID_CONVERT_METRIC_GRID_UNIT_VALUE=0.01500 ................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.