Revamp Panels



PART 1 – GENERALDESCRIPTIONGeneral Requirements are part of this specification and shall apply as if repeated here.Work includes:Interior Decorative Metal Panels Exterior Decorative Metal PanelsInterior Decorative Metal Panels used as railing or guard infillExterior Decorative Metal Panels used as railing or guard infillRelated work not included:SubstratesCOORDINATIONCoordinate installation of anchorages for decorative metal panels. Furnish setting drawings, templates, and directions for installing anchorages, including sleeves, concrete inserts, anchor bolts, and items with integral anchors, that are to be embedded in concrete or masonry. Deliver items to Project site in time for installation.Coordinate installation of decorative formed metal with adjacent construction to ensure that wall assemblies, flashings, trim, and joint sealants, are protected against damage from the effects of weather, age, corrosion, and other causes of deterioration.DESIGN REQUIREMENTSPanel removal: System shall be non-progressive, allowing removal of any individual panel without necessitating removal of adjacent work.Structural movement: Accommodate movement of supporting structural framing and without causing bowing, buckling, delamination, oil canning, excessive stress on fasteners, or any other detrimental effects.Thermal Movements: Allow for thermal movements from ambient and surface temperature changes by preventing buckling, opening of joints, overstressing of components, failure of connections, and other detrimental effects. Base calculations on surface temperatures of materials due to both solar heat gain and nighttime sky heat loss.Temperature Change (Range): 120 deg F, ambient; 180 deg F, material surfacesMaximum deviation from vertical and horizontal alignment of erected panels: 0.25" in 20' 0"Maximum deviation from panel flatness shall be 0.10" in 60" panel in any direction for assembled units (non-accumulative).SAMPLESSubmit samples in accordance with Division 1 Section, Submittals.Submit duplicate, minimum 3-?” x 3-?” samples of each color selected.SHOP DRAWINGSSubmit shop drawings in accordance with Division 1 Section, SubmittalsIndicate elevations, profiles, dimensions and thickness of panels.Indicate location and detail of joints including joints necessary to accommodate thermal movement.Indicate attachment clips, joint extrusion system and installation details.Show fastening and anchoring details.Coordination Drawings: For decorative formed metal elements that house items specified in other Sections. Show dimensions of housed items, including locations of housing penetrations and attachments, and necessary clearancesDrawings for railing and guard infill panels shall be signed and sealed by a Professional Engineer licensed in the jurisdiction where the Project occurs, attesting to the ability of the metal panel's assembly to withstand the specified loads.Panels shall be identified on the shop drawings, using the Specified Identification and as to building location to facilitate panel removal and replacement.LEED SUBMITTALS:Product Data for Credit?MR?4: For products having recycled content, documentation indicating percentages by weight of postconsumer and preconsumer recycled content. Include statement indicating cost for each product having recycled contentDELEGATED DESIGN REQUIREMENTSPerformance and Design Criteria: Where professional design services or certifications by a design professional are specifically required of Contractor by the Contract Documents, provide products and systems complying with specific performance and design criteria indicatedIf criteria indicated are not sufficient to perform services or certification required, submit a written request for additional information to Architect.Delegated-Design Submittal: In addition to Shop Drawings, Product Data, and other required submittals, submit three copies of a statement, signed and sealed by the responsible design professional, for each product and system specifically assigned to Contractor to be designed or certified by a design professionalIndicate that products and systems comply with performance and design criteria in the Contract Documents. Include list of codes, loads, and other factors used in performing these services.Infill at railings and guards: Design metal panel infill for railings and guards, including comprehensive engineering analysis by a qualified professional engineer, using performance requirements and design criteria indicated.Structural Performance of infill at railings and guards: Concentrated load of 50 lbf applied horizontally on an area of 1 sq. ftExterior Panels, Structural Performance: Decorative formed metal items, including anchors and connections, shall withstand the effects of gravity loads and the following loads and stresses without exceeding the allowable design working stress of materials involved and without exhibiting permanent deformation in any components:Wind Loads on Exterior Items: As indicated on the General Structural Notes on the drawings or if not indicated; 30 lb/sq. ft.PRODUCT DELIVERY, HANDLING AND STORAGEProtect finish and edges using a plastic film adhered to panel in accordance with panel manufacturer’s recommendations.Store components and materials in accordance with panel manufacturer’s recommendations.WARRANTYSubmit panel manufacturer’s written warranty covering failure of factory-applied exterior finish within the warranty period. Warranty period for finish: One year after the date of Substantial Completion.PART 2 – PRODUCTSMANUFACTURER OF DECORATIVE METAL PANELS.1Manufacturers of Decorative Metal Panels: Basis of this specification is Revamp Panels, LLC, Products: As Indicated. Products by others may be considered provided the product is submitted for approval in accordance with the Supplementary Instructions to Bidders and Division 1 Specifications, meets the specified requirements and in the opinion of the Architect, conforms to the general properties of the product listed, including color.PROPERTIES OF DECORATIVE PANELS.1Properties are indicated by Part Number. For example: RP001-024036-A3-C01RP001 indicates Panel Pattern Design024036 indicates Panel Size, in this case 24" x 36"A3 indicates Panel Material and thickness, in this case Aluminum, 3/16-inch thicknessC01 indicates Finish, in this case Powder Coat, and Color CodePRODUCTSGeneral: Provide panels as indicated on the Drawings:Panel _____ - Part Number _______Panel _____ - Part Number _______Panel _____ - Part Number _______Panel _____ - Part Number _______PANEL MATERIALS:Aluminum Panels: Alloy 5052Steel Panels: Hot Rolled, Pickled and OiledCor-Ten? Steel: 3/16" A588PANEL FINISHES:UnfinishedCardinal Powder Coat: COLOR:Color to be selected from the manufacturer’s standard color rangeACCESSORIES:1-1/2 x 1-1/2 x 1/4 Aluminum Structural Tee: 6061-T62 x 2 x 3/16 Aluminum Extruded Tee (Architectural Tee): 6063-T523 x 1/4 Aluminum Flat Bar Stock: 6061-T6511Threaded Stud:Manufacturer: PennEngineering.Name: PEM Self-Clinching Stud.Thread?Size:?0.250-20 (1/4-20)Material: Zinc Plated Heat-Treated Carbon SteelPart No. FH-0420-12ZIPART 3 — EXECUTIONEXAMINATIONExamine work of other Sections upon which work of this Section depends.Report any unsatisfactory conditions to Architect in writing. Do not start work until unsatisfactory conditions are rectified.PANEL SYSTEMErect panels and accessories in accordance with system manufacturer’s details and instructions and so as to meet specified design and performance requirements.Finished work shall be securely anchored, free of distortion and surface imperfections, uniform in color and gloss.Use concealed fastenings only, except where exposed fastenings are specifically permitted by Architect in writing.Install panels plumb, true, level and in alignment to established lines and elevations.Where indicated on drawings or as required to complete work of this Section, furnish and install closures, caps, fascia covers and trims with matching panel finish, where exposed.CLEAN-UPRemove protective film from panels.Clean exposed panel surfaces in accordance with manufacturer’s instructions.Repair and touch up minor surface damage with Cardinal DC1 color matching high grade enamel, only where permitted by the Architect and only where appearance after touch-up is acceptable to Architect.Replace damaged panels and components that, in opinion of the Architect, cannot be satisfactorily repaired.END OF SECTION 05 75 43 ................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download