PDF SJOOW - Priority Wire & Cable
PORTABLE CORD
SJOOW 300V Portable Power Cable 90?C
APPLICATION:
Portable tools, equipment, small motors and associated machinery, appliances, equipment exposed to oils, solvents, flame, moisture and other electrical equipment where flexibility and durability are required. For applications up to 300 volts and for temperatures of -40?C to +90?C.
CONDUCTORS:
? Flexible stranded bare copper in accordance with ASTM B-174 and UL 62
INSULATION:
? Premium grade color coded Ethylene Propylene Diene Monomoer (EPDM) insulation or Ethylene Propylene Rubber (EPR) compound class 19 of Table 8 of UL 62
JACKET:
? Overall jacket of black Chlorinated Polyethylene (CPE), which is oil, solvents, ozone, weather, sunlight, and water resistant. Other colors available on request
? CPE compound Class 1.12 90?C comply with Table 11 of UL 62
STANDARDS:
? UL 62 ? CSA C22.2 No. 49 ? Flame test meets FT2, and MSHA ? OSHA accepted
COLOR CODE:
ICEA S-58-679, Method 1, Table 1
No. of Conductors
Color
2
Black, White
3
Black, White, Green
4
Black, White, Red, Green
Part Number
Conductor
Nominal Insulation
Size
No. of Conductor
Thickness
Conductors Stranding
AWG
Inches mm
Nominal Jacket Thickness
Inches mm
Nominal Overal Diameter
Inches mm
Weight lbs/kft
Ampacity** 30?C
Ambient
18-02SJOOW
18
2
16/30 0.030 0.76 0.030 0.76 0.280 7.11 50
10
18-03SJOOW
18
3
16/30 0.030 0.76 0.030 0.76 0.300 7.62 60
10
18-04SJOOW
18
4
16/30 0.030 0.76 0.030 0.76 0.330 8.38 71
7
16-02SJOOW
16
2
26/30 0.030 0.76 0.030 0.76 0.310 7.87 53
13
16-03SJOOW
16
3
26/30 0.030 0.76 0.030 0.76 0.330 8.38 66
13
16-04SJOOW
16
4
26/30 0.030 0.76 0.030 0.76 0.360 9.14 83
10
14-02SJOOW
14
2
41/30 0.030 0.76 0.030 0.76 0.340 8.64 80
18
14-03SJOOW
14
3
41/30 0.030 0.76 0.030 0.76 0.360 9.14 88
18
14-04SJOOW
14
4
41/30 0.030 0.76 0.030 0.76 0.400 10.16 110
15
12-02SJOOW
12
2
41/30 0.030 0.76 0.045 1.14 0.410 10.41 104
25
12-03SJOOW
12
3
41/30 0.030 0.76 0.045 1.14 0.430 10.92 131
25
12-04SJOOW
12
4
41/30 0.030 0.76 0.045 1.14 0.470 11.94 163
20
10-02SJOOW
10
2
103/30 0.045 1.14 0.060 1.52 0.540 13.72 177
30
10-03SJOOW
10
3
103/30 0.045 1.14 0.060 1.52 0.580 14.73 225
30
10-04SJOOW
10
4
103/30 0.045 1.14 0.060 1.52 0.630 16.00 279
25
All values are nominal and subject to correction ** Ampacity values shown are for current carrying conductors. A grounding conductor, or one which carries only the unbalanced current from other conductors, is NOT counted in determining current carrying capacity.
#2280-01
1-800-945-5542
?2020 Priority Wire & Cable 01-2020
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- pdf flexible cables and cords anixter
- pdf 2 the constant acceleration model open university
- pdf 16sig2135 mcxoperatormanualcommercial 2pos 2400509 01 2p rev04
- pdf list of known african american inventors 1845 1980 john
- pdf bayblend t45 t65 t85
- pdf sjoow priority wire cable
- pdf part number 83951 type jx thermocouple 1 pr 16 str fep ins
- pdf birmingham division tax notice the state of alabama jefferson
- pdf organizational clothing and individual equipment ocie guide
- pdf standard pipe a53 cw and erw industrial piping systems
Related searches
- highest priority synonym
- higher priority synonym
- va priority groups copays chart
- va priority groups table 2019
- federal express priority overnight tracking
- fedex first overnight vs priority overnight
- us postal tracking priority mail express
- priority synonym list
- priority antonym thesaurus
- va priority group fact sheet
- va priority groups 2019
- priority antonym