Power Outlet Panels - WESCO

PG00600001E_Cover_wSpine.qxd

8/18/06

10:05 AM

Page 1

Eaton¡¯s electrical business is a global leader in electrical

control, power distribution, and industrial automation products

and services. Through advanced product development, worldclass manufacturing methods, and global engineering services

and support, Eaton¡¯s electrical business provides customerdriven solutions under brand names such as Cutler-HammerT,

PowerwareT, DurantT, HeinemannT, HolecT and MEMT, which

globally serve the changing needs of the industrial, utility,

light commercial, residential, and OEM markets. For more

information, visit .

Power Outlet Panels

Eaton Corporation is a diversified industrial manufacturer with

2005 sales of $11.1 billion. Eaton is a global leader in electrical systems

and components for power quality, distribution and control; fluid

power systems and services for industrial, mobile and aircraft equipment;

intelligent truck drivetrain systems for safety and fuel economy; and

automotive engine air management systems, powertrain solutions and

specialty controls for performance, fuel economy and safety. Eaton has

60,000 employees and sells products to customers in more than 125 countries.

For more information, visit

Eaton Electrical Inc.

1000 Cherrington Parkway

Moon Township, PA 15108

United States

tel: 1-800-525-2000



Product Guide

Cutler-Hammer is a federally registered

trademark of Eaton Corporation. National

Electrical Code and NEC are registered

trademarks of the National Fire Protection

Association, Quincy, Mass. NEMA is the

registered trademark and service mark of

the National Electrical Manufacturers

Association. Russellstoll is a registered

trademark of Thomas & Betts Corporation.

UL is a federally registered trademark of

Underwriters Laboratories Inc.

? 2006 Eaton Corporation

All Rights Reserved

Printed in USA

Publication No. PG00600001E / Z4452

August 2006

Temporary Power

RV/Campground

Marina

Power Outlet Panels

A Powerful Solution for

Construction, RV Parks & Marinas

Contents

Temporary Power

Product and Application Description. . . . . . . . . . . . . . . . . . . . . . . . . . 2

Catalog Numbering System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Unmetered Surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Metered Surface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Metered Bottom Feed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Recreational Vehicle/Campground Products

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Heavy-Duty Pow-R-Redi Campground Power Outlet Panels . . . . . . 16

Custom Design Resin and Stainless Steel Pedestals

and Power Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Marina Product Family

Custom Design Marina Power Products and Accessories . . . . . . . . 54

EATON CORPORATION Cutler-Hammer Power Outlet Panels Product Guide PG00600001E RCopyright 2006 Eaton Corporation

1

Temporary Power ¡ª

Product & Application Description

Product Description

A Power Outlet Panel (or POP)

is a device designed for outdoor

service to meet temporary

power requirements at construction sites and recreation vehicle

(RV) parks. Construction sites

and RV parks need to provide

a safe and reliable means for

users to access electricity and

POPs provide the outlets for

electrical access.

Application

Description

Power Outlet Panels or POPs

are also sometimes called

Temporary Power Panels,

Temporary Site Service

Equipment or RV Panels.

Construction Site

Application

When POPs are used at a

construction site, they are

installed on a temporary basis

until electrical power is available

at the building. The most

common reason for needing

a POP at a construction site is

to provide a power source for

the contractor¡¯s tools.

Eaton¡¯s Cutler-HammerT Designed for Easy

Installation and Protection

Power Outlet Panels

Power Where You Need It,

When You Need It

¡ñ

Features

¡ñ

¡ñ

¡ñ

Designed for outdoor service

to meet power outlet

requirements.

Receptacles conform to NEMAT

and/or ANSI configurations

as specified by NECT.

¡ñ

¡ñ

Suitable for use as service

entrance equipment.

¡ñ

¡ñ

¡ñ

Includes a factory installed

insulated neutral bar with

provisions for bonding when

used for service entrance

applications.

¡ñ

125 ampere rated meter

socket.

¡ñ

Door swings up and open

for user convenience and

ease of access to breakers

and receptacles.

Panels can be bottom fed

through knockouts in endwall

or top fed using a bolt-on

raintight hub.

Two-piece deadfront cover

allows field wiring without

interfering with factory

wiring.

Lower deadfront cover

permits easy field wiring to

circuit protective devices.

GFI (ground fault interrupter)

1- and 2-pole protection

through 50 amperes.

Marina Applications

Surface Units

NEMA 3R construction for rainproof installation.

100 percent galvanized

steel with baked-on

polyester powder coating.

Utility grade metering available for construction

site RV park applications.

Three-point mounting.

Door swings up and pushes in to lock into open

position. Pull out and push down to close door.

One-piece case back for

metered and unmetered

panels.

Lighted option for site

location and nighttime

panel operations.

GFI circuit breakers

available through

50 amperes.

Construction Site Application

Panels come from the factory

completely assembled,

prewired with 100 percent

copper wire and tested,

ready for easy installation.

Unique steel barrier

prevents unauthorized

operation of breakers

when door is closed

and padlocked.

Metered units available with

meter on top or on bottom.

Removable upper deadfront cover for easy

incoming wire connections to breaker terminals.

Lower deadfront cover rotates 90 degrees or can

be removed for easy routing of incoming wires

or receptacle changeouts.

Padlock provisions to prevent unauthorized

entry.

Units are factory wired and assembled.

FIGURE 1. SURFACE UNITS DIAGRAM

2

EATON CORPORATION Cutler-Hammer Power Outlet Panels Product Guide PG00600001E Effective: August 2006

Temporary Power ¡ª

Product Family

Temporary Power Product Family

Surface Mount Units

Single Receptacle

Unmetered Type

Metered Ring or Ringless

Type Bottom Feed

Metered Ring or Ringless Type

EATON CORPORATION Cutler-Hammer Power Outlet Panels Product Guide PG00600001E RCopyright 2006 Eaton Corporation

3

Temporary Power ¡ª

Catalog Numbering System

Product Selection

TABLE 1. CATALOG NUMBERING SYSTEM

When quoting or selecting a

Power Outlet Panel, the following items should be considered:

¡ñ

¡ñ

¡ñ

¡ñ

¡ñ

CH M 1 N 7 N 4 N S X U

Unmetered, Ring or

Ringless Style.

Cutler-Hammer

Number and types of

receptacles (7 standard and

8 twist-lock options).

Metering Type

U = Unmetered

M= Metered-Ring

R = MeteredRingless

Standard or Ground Fault

Breakers.

Surface mounting.

Receptacle Type

Left Position 1

Are any factory or field

options required?

1=

2=

3=

4=

5=

6=

7=

Blank =

NEMA 14-50R

NEMA 10-50R

NEMA 14-30R

NEMA TT-30R

NEMA 6-20R2

NEMA 5-20R2

NEMA 5-20R2GFI

No Receptacle

Receptacle Type

Center Position 1

1=

2=

3=

4=

5=

6=

7=

Blank =

N = Non-Ground Fault

G = Ground Fault

Interior

N = Non-Ground Fault

G = Ground Fault

X = Six Circuit

Blank = Standard

Four Circuit

Receptacle Type

Right Position 1

1=

2=

3=

4=

5=

6=

7=

N = Non-Ground Fault

G = Ground Fault

2

Feed

U = Bottom

Fed 2

Blank = Top Fed

Circuit Breaker Type

Position 3

Circuit Breaker Type

Position 2

Circuit Breaker Type

Position 1

1

NEMA 14-50R

NEMA 10-50R

NEMA 14-30R

NEMA TT-30R

NEMA 6-20R2

NEMA 5-20R2

NEMA 5-20R2GFI

No Receptacle

Mounting

S = Surface

NEMA 14-50R

NEMA 10-50R

NEMA 14-30R

NEMA TT-30R

NEMA 6-20R2

NEMA 5-20R2

NEMA 5-20R2GFI

For receptacle configurations, see Table 2.

Only available with metered surface mount units.

TABLE 2. RECEPTACLE CONFIGURATION

1

50 ampere, 125/250 volt

3-pole, 4-wire,

NEMA 14-50R

4

30 ampere, 125 volt

2-pole, 3-wire,

NEMA TT-30R

5

20 ampere, 250 volt,

2-pole, 3-wire,

NEMA 6-20R2

2-pole 50 ampere breaker

2

50 ampere, 125/250 volt

2-pole, 3-wire,

NEMA 10-50R

3

30 ampere, 125/250 volt

3-pole, 4-wire,

NEMA 14-30R

2-pole 50 ampere breaker

6

1-pole 30 ampere breaker

2-pole 20 ampere breaker

20 ampere, 125 volt,

2-pole, 3-wire,

NEMA 5-20R2

1-pole 20 ampere breaker

7

20 ampere, 125 volt,

2-pole, 3-wire,

NEMA 5-20R2GFI

1-pole 20 ampere breaker

2-pole 30 ampere breaker

Note: Twist-lock receptacles are not listed in Table 1 as not all receptacle combinations are valid

even though one can create a catalog number. Contact Eaton for a quote on twist-lock and

custom receptacle/breaker combinations.

4

EATON CORPORATION Cutler-Hammer Power Outlet Panels Product Guide PG00600001E Effective: August 2006

................
................

In order to avoid copyright disputes, this page is only a partial summary.