Power Outlet Panels - WESCO
PG00600001E_Cover_wSpine.qxd
8/18/06
10:05 AM
Page 1
Eaton¡¯s electrical business is a global leader in electrical
control, power distribution, and industrial automation products
and services. Through advanced product development, worldclass manufacturing methods, and global engineering services
and support, Eaton¡¯s electrical business provides customerdriven solutions under brand names such as Cutler-HammerT,
PowerwareT, DurantT, HeinemannT, HolecT and MEMT, which
globally serve the changing needs of the industrial, utility,
light commercial, residential, and OEM markets. For more
information, visit .
Power Outlet Panels
Eaton Corporation is a diversified industrial manufacturer with
2005 sales of $11.1 billion. Eaton is a global leader in electrical systems
and components for power quality, distribution and control; fluid
power systems and services for industrial, mobile and aircraft equipment;
intelligent truck drivetrain systems for safety and fuel economy; and
automotive engine air management systems, powertrain solutions and
specialty controls for performance, fuel economy and safety. Eaton has
60,000 employees and sells products to customers in more than 125 countries.
For more information, visit
Eaton Electrical Inc.
1000 Cherrington Parkway
Moon Township, PA 15108
United States
tel: 1-800-525-2000
Product Guide
Cutler-Hammer is a federally registered
trademark of Eaton Corporation. National
Electrical Code and NEC are registered
trademarks of the National Fire Protection
Association, Quincy, Mass. NEMA is the
registered trademark and service mark of
the National Electrical Manufacturers
Association. Russellstoll is a registered
trademark of Thomas & Betts Corporation.
UL is a federally registered trademark of
Underwriters Laboratories Inc.
? 2006 Eaton Corporation
All Rights Reserved
Printed in USA
Publication No. PG00600001E / Z4452
August 2006
Temporary Power
RV/Campground
Marina
Power Outlet Panels
A Powerful Solution for
Construction, RV Parks & Marinas
Contents
Temporary Power
Product and Application Description. . . . . . . . . . . . . . . . . . . . . . . . . . 2
Catalog Numbering System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Unmetered Surface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Metered Surface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Metered Bottom Feed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Recreational Vehicle/Campground Products
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Heavy-Duty Pow-R-Redi Campground Power Outlet Panels . . . . . . 16
Custom Design Resin and Stainless Steel Pedestals
and Power Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Marina Product Family
Custom Design Marina Power Products and Accessories . . . . . . . . 54
EATON CORPORATION Cutler-Hammer Power Outlet Panels Product Guide PG00600001E RCopyright 2006 Eaton Corporation
1
Temporary Power ¡ª
Product & Application Description
Product Description
A Power Outlet Panel (or POP)
is a device designed for outdoor
service to meet temporary
power requirements at construction sites and recreation vehicle
(RV) parks. Construction sites
and RV parks need to provide
a safe and reliable means for
users to access electricity and
POPs provide the outlets for
electrical access.
Application
Description
Power Outlet Panels or POPs
are also sometimes called
Temporary Power Panels,
Temporary Site Service
Equipment or RV Panels.
Construction Site
Application
When POPs are used at a
construction site, they are
installed on a temporary basis
until electrical power is available
at the building. The most
common reason for needing
a POP at a construction site is
to provide a power source for
the contractor¡¯s tools.
Eaton¡¯s Cutler-HammerT Designed for Easy
Installation and Protection
Power Outlet Panels
Power Where You Need It,
When You Need It
¡ñ
Features
¡ñ
¡ñ
¡ñ
Designed for outdoor service
to meet power outlet
requirements.
Receptacles conform to NEMAT
and/or ANSI configurations
as specified by NECT.
¡ñ
¡ñ
Suitable for use as service
entrance equipment.
¡ñ
¡ñ
¡ñ
Includes a factory installed
insulated neutral bar with
provisions for bonding when
used for service entrance
applications.
¡ñ
125 ampere rated meter
socket.
¡ñ
Door swings up and open
for user convenience and
ease of access to breakers
and receptacles.
Panels can be bottom fed
through knockouts in endwall
or top fed using a bolt-on
raintight hub.
Two-piece deadfront cover
allows field wiring without
interfering with factory
wiring.
Lower deadfront cover
permits easy field wiring to
circuit protective devices.
GFI (ground fault interrupter)
1- and 2-pole protection
through 50 amperes.
Marina Applications
Surface Units
NEMA 3R construction for rainproof installation.
100 percent galvanized
steel with baked-on
polyester powder coating.
Utility grade metering available for construction
site RV park applications.
Three-point mounting.
Door swings up and pushes in to lock into open
position. Pull out and push down to close door.
One-piece case back for
metered and unmetered
panels.
Lighted option for site
location and nighttime
panel operations.
GFI circuit breakers
available through
50 amperes.
Construction Site Application
Panels come from the factory
completely assembled,
prewired with 100 percent
copper wire and tested,
ready for easy installation.
Unique steel barrier
prevents unauthorized
operation of breakers
when door is closed
and padlocked.
Metered units available with
meter on top or on bottom.
Removable upper deadfront cover for easy
incoming wire connections to breaker terminals.
Lower deadfront cover rotates 90 degrees or can
be removed for easy routing of incoming wires
or receptacle changeouts.
Padlock provisions to prevent unauthorized
entry.
Units are factory wired and assembled.
FIGURE 1. SURFACE UNITS DIAGRAM
2
EATON CORPORATION Cutler-Hammer Power Outlet Panels Product Guide PG00600001E Effective: August 2006
Temporary Power ¡ª
Product Family
Temporary Power Product Family
Surface Mount Units
Single Receptacle
Unmetered Type
Metered Ring or Ringless
Type Bottom Feed
Metered Ring or Ringless Type
EATON CORPORATION Cutler-Hammer Power Outlet Panels Product Guide PG00600001E RCopyright 2006 Eaton Corporation
3
Temporary Power ¡ª
Catalog Numbering System
Product Selection
TABLE 1. CATALOG NUMBERING SYSTEM
When quoting or selecting a
Power Outlet Panel, the following items should be considered:
¡ñ
¡ñ
¡ñ
¡ñ
¡ñ
CH M 1 N 7 N 4 N S X U
Unmetered, Ring or
Ringless Style.
Cutler-Hammer
Number and types of
receptacles (7 standard and
8 twist-lock options).
Metering Type
U = Unmetered
M= Metered-Ring
R = MeteredRingless
Standard or Ground Fault
Breakers.
Surface mounting.
Receptacle Type
Left Position 1
Are any factory or field
options required?
1=
2=
3=
4=
5=
6=
7=
Blank =
NEMA 14-50R
NEMA 10-50R
NEMA 14-30R
NEMA TT-30R
NEMA 6-20R2
NEMA 5-20R2
NEMA 5-20R2GFI
No Receptacle
Receptacle Type
Center Position 1
1=
2=
3=
4=
5=
6=
7=
Blank =
N = Non-Ground Fault
G = Ground Fault
Interior
N = Non-Ground Fault
G = Ground Fault
X = Six Circuit
Blank = Standard
Four Circuit
Receptacle Type
Right Position 1
1=
2=
3=
4=
5=
6=
7=
N = Non-Ground Fault
G = Ground Fault
2
Feed
U = Bottom
Fed 2
Blank = Top Fed
Circuit Breaker Type
Position 3
Circuit Breaker Type
Position 2
Circuit Breaker Type
Position 1
1
NEMA 14-50R
NEMA 10-50R
NEMA 14-30R
NEMA TT-30R
NEMA 6-20R2
NEMA 5-20R2
NEMA 5-20R2GFI
No Receptacle
Mounting
S = Surface
NEMA 14-50R
NEMA 10-50R
NEMA 14-30R
NEMA TT-30R
NEMA 6-20R2
NEMA 5-20R2
NEMA 5-20R2GFI
For receptacle configurations, see Table 2.
Only available with metered surface mount units.
TABLE 2. RECEPTACLE CONFIGURATION
1
50 ampere, 125/250 volt
3-pole, 4-wire,
NEMA 14-50R
4
30 ampere, 125 volt
2-pole, 3-wire,
NEMA TT-30R
5
20 ampere, 250 volt,
2-pole, 3-wire,
NEMA 6-20R2
2-pole 50 ampere breaker
2
50 ampere, 125/250 volt
2-pole, 3-wire,
NEMA 10-50R
3
30 ampere, 125/250 volt
3-pole, 4-wire,
NEMA 14-30R
2-pole 50 ampere breaker
6
1-pole 30 ampere breaker
2-pole 20 ampere breaker
20 ampere, 125 volt,
2-pole, 3-wire,
NEMA 5-20R2
1-pole 20 ampere breaker
7
20 ampere, 125 volt,
2-pole, 3-wire,
NEMA 5-20R2GFI
1-pole 20 ampere breaker
2-pole 30 ampere breaker
Note: Twist-lock receptacles are not listed in Table 1 as not all receptacle combinations are valid
even though one can create a catalog number. Contact Eaton for a quote on twist-lock and
custom receptacle/breaker combinations.
4
EATON CORPORATION Cutler-Hammer Power Outlet Panels Product Guide PG00600001E Effective: August 2006
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- rv plastic pedestal usred
- recreational vehicle campground products
- atts tion on the age
- electric service and meter installations manual
- product catalog 2019
- metered modular rv pedestal
- power outlet panel types available
- wiring rv pedestal milbank
- power outlet panels wesco
- 2020 permanent seasonal amp site application
Related searches
- sip panels for sale
- replacement body panels chevy truck
- angle for solar panels calculator
- solar panels 4000 watts
- how many solar panels for 1000 kwh
- ge electrical panels load center
- 4x8 sip panels for sale
- sip panels manufacturers
- solar panels estimator
- cost of solar panels for homes
- calculate how many solar panels i need
- sip roof panels for sale