COMMUNICATION PROTOCOL(NMS&DEBUG)



May 18, 2006

R&D CENTER

Contents

1. Overview

2. AICM Basic Specifications

2.1 Input Power

2.2 ANT Beam Tilting

2.3 Communication

2.3.1 TCP/IP Communication

2.3.2 Debug Communication

2.3.3 RS-485/422 Communications

2.4 LED

2.5 Hardware Specification

2.6 Operating Environment

2.7 EMC Requirement

2.7.1 Electromagnetic emission

2.7.2 Electromagnetic sensitivity

3. AICM Additional Specifications

3.1 AC Input Power (OPTION 1)

3.2 ANT VSWR Support ( OPTION 2)

3.3 AMA Support ( OPTION 3)

4. FULL Optional Drawing

1. Optional Drawing

5. AICM FULL OPTIONAL BLOCK

1. Overview

AICM (Air Interface Control Module) is an antenna control unit for performing Electrical beam tilting, beam width control, mechanical steering. In order for communicating with AICM management server, it supports Ethernet and RS-485/422/232 Serial interface and conducts antenna reset, status monitoring, and antenna beam control. It also provides direct user interface for installation and maintenance. It can accommodate up to 3 antennas. Besides, AC power input, antenna VSWR monitoring, AMA support are also supported as features.

* AMA (Antenna Mounted Amplifier) is the same as TMA (Tower Mounted Amplifier).

2. AICM Basic Specifications

2.1 Input Power

| |Power Type |Power Range |Current |Remarks |

|IN PUT |DC |-48V (-37V ~ -72V) |48V, 300mA, (Normal) |Customer Spec |

2.2 ANT Beam Tilting

AICM can control 3 antennas and antenna control range and step as as follows.

|Beam Tilting Range |0° ~ 20°(MAX.) |

|Beam Tilting Step |0.5° |

|Beam Steering Range |-30° ~ 30° |

|Beam Steering Step |1° |

|Beam Width Control Range |33° ~ 120° |

|Beam Width Control Step |Continous control |

2.3 Communication

2.3.1 TCP/IP Communication

Communication with AICM Management server can be done by TCP/IP protocol and status monitor and antenna control can be done remotely.

Communication Specification: 10/100 Base-T, IEEE 802.3/802.3u Compliants

Communication Protocol: TCP/IP, DHCP, UDP

2.3.2 Debug Communication

AICM support a debug port for installation and maintenance (RS232C).

Communication Parameter Settings: 38400, N, 8, 1

2.3.3 RS-485/422 Communication

AICM supports RS-485/422 for communication with BTS and AICM management server.

2.4 LED

Status monitor LEDs are located in front of panel and detail functions are as follow.

|Name marked |Color |Status |Remarks |

| POWER |Green |LED turn on when the power is applied | |

| ALM |Red |LED turn on when occurrence of any alarm no matter what alarm type | |

|ACT |Yellow |Status is On when transmit/receive data through Ethernet Port. | |

|LINK |Green |On when LAN cable connected to Ethernet Port. | |

|Tx |Green |Turn on one time (200ms) when data transmit from RBS to AICM | |

|Rx |Green |Turn on one time (200ms) when data transmit from AICM to RBS | |

|Alpha |OPER |Green |ON when antenna is connected to AICM Alpha path | |

| |TTA_ALM* |Red |Turn on when current alarm of Alpha path AMA |Only with OPTION 2|

| |VSWR_M* |Green |Turn on when VSWR alarm of Alpha path main Antenna |Only with OPTION 3|

| |VSWR_D* |Red |Turn on when VSWR alarm of Alpha path diversity Antenna | |

|Beta |OPER |Green |ON when antenna is connected to AICM Beta path | |

| |TTA_ALM* |Red |Turn on when current alarm of Beta path AMA |Only with OPTION 2|

| |VSWR_M* |Green |Turn on when VSWR alarm of Beta path main Antenna |Only with OPTION 3|

| |VSWR_D* |Red |Turn on when VSWR alarm of Beta path diversity Antenna | |

|Gamma |OPER |Green |ON when antenna is connected to AICM Gamma path | |

| |TTA_ALM* |Red |Turn on when current alarm of Gamma path AMA |Only with OPTION 2|

| |VSWR_M* |Green |Turn on when VSWR alarm of Gamma path main Antenna |Only with OPTION 3|

| |VSWR_D* |Red |Turn on when VSWR alarm of Gamma path diversity Antenna | |

* There’s no LEDs if OPTION 2, OPTION 3 are not purchased

2.5 Hardware Specifications

AICM Hardware specifications are as follow.

|Items |Size |Remarks |

|Height |1U |EIA Standard |

|Width |482mm | |

|Depth |320mm | |

|Weight |Weight ≤ 10Kg (MAX) | |

* Refer to the diagrams in Section 4.

2.6 Operating Environments

AICM Operating environments are as follow.

|Item |Specifications |Remarks |

|Operating Temperature |-10℃ ~ 70℃ | |

|Humidity |5% ~ 95% | |

|Storate Temperature |-40℃ ~ 80℃ | |

2.7 EMC Requirement

2.7.1 Electromagnetic emission

2.7.1.1 Radiation emission(RE)

1) Adopted standard : CISPR22

2) Limited value requirement : CLASS A

2.7.1.2 Conducted emission(CE)

1) Adopted standard : CISPR22

2) Limit value requirement : CLASS A

2.7.2 Electromagnetic sensitivity

2.7.2.1 Electrostatic discharging immunity tests (ESD)

1) Contact discharging : ±4KV

2) Air discharging : ±8KV

2.7.2.2 EFT/B

1) Open circuit output voltage(±10%) : Voltage peak 1kV

2) Pulse repetition rate(±20%) : 5kHz

2.7.2.3 Surge, common and differential mode

1) Open circuit voltage of 1.2/50uS

Line – line : ±0.5kV

Line – ground : ±1Kv

SMA Port : ±1Kv

3. AICM Additional Features

3.1 AC Input Power (OPTION 1)

|Input Power |Range |Remarks |

|AC |100V~260V (50~60Hz) | |

3.2 ANT VSWR Support (OPTION 2)

As an optional feature, AICM can monitor antenna functionality by checking VSWR on each antenna port. VSWR Alarm is triggered when following conditions met.

|ANT POWER |≤ 24dB |30dBm ~ 48dBm |Frequency range |

|Alarm threshold |VSWR ≥ 2.5 |No Detect |VSWR ALARM |2110~2170MHz |

| |VSWR ≤ 1.5 | |VSWR NO ALARM | |

| |NO VSWR ALARM |VSWR ALARM OR NO ALARM |VSWR MUST ALARM | |

| | | | | |

|1.0 | | |1.5 | |

| | | | | |

| | | |24dBm | | | |

3.3 AMA Support ( OPTION 3)

| |Specifications |Remarks |

|Output Power |DC 15V (±0.5V) |Customer Specs |

|Power consumption |TBD | |

|Low Level Alarm Limit |TBD | |

|Low Level Alarm Limit Range |TBD | |

|High Level Alarm Limit |TBD | |

|High Level Alarm Limit Range |TBD | |

* AMA (Antenna Mounted Amplifier)

4. FULL Optional Drawing

[pic]

4.1 Optional Drawing

[pic] : No connector if OPTION 1 (AC220V) is not purchased

: No connectors and LEDs if OPTION 2 (ANT VSWR Support) is not purchased.