High Purity Ceramic Sensor

嚜燉MK 809

Plastic Probe

for Aggressive Media

High Purity Ceramic Sensor

accuracy according to IEC 60770:

standard: 0.35 % FSO

option: 0.25 % FSO

Nominal pressure

from 0 ... 0.4 mH2O up to 0 ... 100 mH2O

Output signals

Basic element of the plastic probe is the flush

mounted ceramic sensor, which makes cleaning easier when solid parts of the medium deposit on it. Different cable and seal materials are available in order

to achieve maximum media compatibility.

2-wire: 4 ... 20 mA

3-wire: 0 ... 10 V

others on request

Special characteristics

?

diameter 45 mm

?

chemical resistance

?

high overpressure resistance

?

especially for tank level

measurement of viscous and

aggressive media

?

diaphragm 99.9 % AI2O3

?

housing material PP-HT or PVDF

The plastic submersible probe LMK 809 is

designed for continuous level measurement in highly

polluted and most of aggressive media. Basic element is a capacitive ceramic sensor.

Preferred areas of use are

Sewage

waste water treatment

water recycling

dumpsite

Aggressive media

level measurement in

most of acids and lyes

Optional versions

?

different kinds of cables

and elastomers

?

prepared for mounting with pipe

BD SENSORS GmbH

BD-Sensors-Stra?e 1

D - 95199 Thierstein

Tel.:

Fax:

+49 (0) 92 35 / 98 11- 0

+49 (0) 92 35 / 98 11- 11

bdsensors.de

info@bdsensors.de

LMK 809

Plastic Probe

Technical Data

Input pressure range

Nominal pressure gauge

[bar] 0.04

Level

[mH2O] 0.4

Overpressure

[bar]

2

Max. ambient pressure (housing): 10 bar

Output signal / Supply

Standard

Option

Performance

Accuracy 1

2-wire:

3-wire:

0.4

4

6

0.6

6

8

1

10

8

1.6

16

15

2.5

25

25

4 ... 20 mA / VS =

9 ... 32 VDC

0 ... 10 V / VS = 12.5 ... 32 VDC

load: 0.05 % FSO / k?

measuring rate: 5/sec

≒ ㊣ 1 % FSO

-20 # 80 ∼C

medium / electronic / environment / storage:

-25 # 80 ∼C

permanent

no damage, but also no function

emission and immunity according to EN 61326

PUR

(-25 # 70 ∼C)

black

? 7.4 mm

FEP 4

(-25 # 70 ∼C)

black

? 7.4 mm

TPE-U

(-25 # 100 ∼C)

blue

? 7.4 mm

others on request

signal line/shield also signal line/signal line: 160 pF/m

signal line/shield also signal line/signal line: 1 ?H/m

static installation:

10-fold cable diameter

dynamic application: 20-fold cable diameter

Cable capacitance

Cable inductance

Bending radius

4

0.25

2.5

6

additional external overvoltage protection unit in terminal box KL 1 or KL 2 with atmospheric pressure reference available on request

Electrical connection

Cable with sheath material 3

3

0.16

1.6

4

accuracy according to IEC 60770 每 limit point adjustment (non-linearity, hysteresis, repeatability)

Thermal effects (offset and span)

Tolerance band

In compensated range

Permissible temperatures

Permissible temperatures

Electrical protection 2

Short-circuit protection

Reverse polarity protection

Electromagnetic compatibility

2

0.1

1

4

standard:

≒ ㊣ 0.35 % FSO

option:

≒ ㊣ 0.25 % FSO

Rmax = [(VS 每 VS min) / 0.02 A] ?

supply: 0.05 % FSO / 10 V

≒ ㊣ 0.1 % FSO / year at reference conditions

700 msec

< 200 msec

380 msec

Permissible load

Influence effects

Long term stability

Turn-on time

Mean response time

Max. response time

1

0.06

0.6

2

shielded cable with integrated ventilation tube for atmospheric pressure reference

do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expected

Materials (media wetted)

Housing

standard: PP-HT

option:

PVDF

FKM, EPDM, FFKM

ceramics Al2O3 99.9 %

PUR, FEP, TPE-U

Seals

Diaphragm

Cable sheath

Miscellaneous

Option cable protection

Current consumption

Weight

Ingress protection

CE-conformity

Wiring diagrams

prepared for mounting with plastic pipe

max. 21 mA

approx. 320 g (without cable)

IP 68

EMC Directive: 2014/30/EU

2-wire-system (current)

3-wire-system (voltage)

supply +

supply +

p

p

VS

VS

supply 每

supply 每

I

pressure and level

U

signal +

V

4

40

25

6

60

35

10

100

35

LMK 809

Plastic Probe

Technical Data

Pin configuration

Electrical connection

cable colours (IEC 60757)

WH (white)

BN (brown)

GN (green)

GNYE (green-yellow)

Supply +

Supply 每

Signal + (only for 3-wire)

Shield

Dimensions (mm / in)

option

prepared for mounting with pipe

Accessories

Terminal clamp

Technical data

Suitable for

all probes with cable ? 5.5 ... 10.5 mm

Material of housing

standard: steel, zinc plated

optionally: stainless steel 1.4301 (304)

Material of clamping jaws

PA (fibre-glass reinforced)

and positioning clips

Dimensions (mm)

174 x 45 x 32

Hook diameter

20 mm

Weight

Ordering type

Ordering code

Terminal clamp, steel, zinc plated

Z100528

approx. 160 g

Terminal clamp, stainless steel 1.4301 (304)

Z100527

LMK809_E_120123

Tel.:

Fax:

+49 (0) 92 35 / 98 11- 0

+49 (0) 92 35 / 98 11- 11

bdsensors.de

info@bdsensors.de

? 2023 BD|SENSORS GmbH 每 The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.

standard

Ordering code LMK 809

LMK 809

in bar

in mH2O

[mH2O]

[bar]

0.4

0.04

0.6

0.06

1.0

0.10

1.6

0.16

2.5

0.25

4.0

0.40

6.0

0.60

10

1.0

16

1.6

25

2.5

40

4.0

60

6.0

100

10

customer

Input

Housing

Diaphragm

-

0

0

1

1

2

4

6

1

1

2

4

6

1

9

4

6

0

6

5

0

0

0

6

5

0

0

0

9

Accuracy

standard:

option:

-

-

-

-

0

0

0

0

0

0

0

0

0

0

0

0

0

9

0

0

0

0

0

0

0

1

1

1

1

1

2

9

consult

consult

C

9

4 # 20 mA / 2-wire

0 # 10 V / 3-wire

customer

consult

1

3

9

FKM

EPDM

FFKM

customer

consult

1

3

7

9

0.35 % FSO

0.25 % FSO

customer

Electrical connection

PUR-cable (black, ? 7.4 mm)

FEP-cable (black, ? 7.4 mm)

TPE-U-cable (blue, ? 7.4 mm)

customer

Cable length

in m

Special version

standard

prepared for pipe R1"

customer

-

R

B

9

ceramics Al2O3 99.9 %

customer

Seal

-

3 9 5

3 9 6

PP-HT

PVDF

customer

Output

-

consult

3

2

9

1

1

1

consult

2

3

4

9

consult

9 9 9

2

1

shielded cable with integrated ventilation tube for atmospheric pressure reference

2

pipe is not part of the supply

0 0 0

6 1 0

9 9 9

consult

01.04.2022

? 2022 BD|SENSORS GmbH - The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.

Pressure

-

................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download