Data Collection - Hewlett Packard Enterprise …
Data Collection
|Brocade |McData (QLogic) 4Gb Switches|McData (Legacy Switches) |Cisco |
|‘supportShow’ (pre 4.4.x) |‘show support’ |n/a (See “Collecting Initial|‘show tech-support’ |
|or | |Data”) |or |
|‘supportSave’ (later than 4.4.x) | | |‘show tech-support brief’ |
| | | |or |
| | | |‘show tech-support details’ |
|‘errClear’ | |‘show eventlog clear’ |‘clear logging logfile’ (MDS|
| | | |9120) |
|‘errDump’ | | |‘show logging’ |
|‘errShow’ |‘show port X’ |‘show eventlog’ |‘attach module X’ |
| | | |“show port-config internal |
| | | |link-events” |
| | | |or |
| | | |‘show logging’ |
|‘syslogdIpAdd ’ |‘set setup system’ | |‘config t’ |
| | | |“logging server ip-address |
| | | |facility local1” |
|‘syslogdIpRemove ’ |‘set setup system’ | |‘config t’ |
| | | |‘no logging server’ |
|‘syslogdIpShow’ |‘show setup system’ | |‘show logging server’ |
|‘supportShowCfgEnable ’ | |n/a | |
|‘supportShowCfgDisable ’ | |n/a | |
|‘supportShowCfgShow’ | |n/a | |
Overall Switch Status Commands
|Brocade |McData (QLogic) 4Gb Switches |McData (Legacy Switches) |Cisco |
|‘bladeBeacon slotnumber [mode]’ | | |‘config t’ |
| | | |‘interface fcX/X’ |
| | | |‘switchport beacon’ |
| | | |or |
| | | |‘no switchport beacon’ |
|‘bladeDisable slotnumber’ | | |‘config t’ |
| | | |‘interface fcX/X shutdown’|
|‘bladeEnable slotnumber’ | | |‘config t’ |
| | | |“interface fcX/X no |
| | | |shutdown” |
|‘bladePropShow [[--slot] slotnumber]’ | | |‘show interface fcX/X’ |
|‘chassisName [name]’ | |‘show system’ |‘show switchname’ |
| | |or | |
| | |‘config system name’ | |
|‘chassisShow’ | |‘show frus’ |‘show hardware’ |
|‘configDefault’ |‘config cancel’ |‘maint system resetConfig’|‘write erase’ |
| | | |‘reload’ |
|‘configDownload’ |‘config restore’ |n/a (Must be replaced |“copy |
| | |manually from collected |t |
| | |data) |nvram:startup-config” |
|‘configShow’ |‘config list’ |Use the various ‘show’ and|‘show running-config’ |
| | |‘config’ commands |or |
| | | |‘show startup-config’ |
|‘configUpload’ |‘config backup’ |n/a (See “Collecting |“copy nvram:startup-config|
| | |Initial Data” above) |t” |
|‘configure’ |‘config edit {CONFIG_NAME}’ |‘config’ |‘config terminal’ |
| |or | | |
| |‘config edit’ | | |
| |‘set config switch’ | | |
|‘date’ |‘date’ |‘config system date’ |‘show clock’ |
|or |or | |or |
|‘date "mmddhhmmyy"’ |‘date {MMDDhhmmCCYY} ‘ | |‘clock set’ |
|‘dlsReset’ | | |‘config t’ |
| | | |‘no fspf enable vsan X’ |
|‘dlsSet’ | | |‘config t’ |
| | | |‘fspf enable vsan X’ |
|‘dlsShow’ | | |‘show fspf’ |
|‘fabricPrincipal [ -fhq ][ mode ]’ |‘config edit’ | |‘config t’ |
| |‘set config switch’ | |‘fcdomain priority x vsan |
| | | |X’ |
| | | |(Note: switch priority can|
| | | |be set to a number from |
| | | |1-254 with 1 being the |
| | | |highest. The switch with |
| | | |the highest priority |
| | | |becomes principal.) |
|‘fabricShow’ | | |“show fcdomain domain-list|
| | | |vsan X” |
|‘fastboot’ |‘reset’ |‘maint system ipl’ | |
| ‘haDump’ | | | |
|‘haShow’ | | |“show system redundancy |
| | | |status” |
|‘help’ |? or ‘help’ |? |? |
|‘history’ (or ‘h’) |‘history’ | | |
|‘historyLastShow’ | | | |
|‘historyShow’ | | | |
|‘httpCfgShow’ | | | |
|‘ifModeSet ’ | | | |
|‘ifModeShow ’ |‘show setup system’ | |‘show ip route’ |
| |or | |or |
| |‘show about’ | |‘show interface mgmt0’ |
| |or | | |
| |‘show interface’ | | |
|‘interopMode [mode]’ |‘config edit’ |‘show switch’ |‘show running’ |
| |‘set config switch’ |or |or |
| |and to display interopmode: |‘config switch |‘show vsan X’ |
| |‘show config switch’ |interopMode’ | |
|‘iodReset’ | | |‘config t’ |
| | | |‘no in-order-guarantee’ |
|‘iodSet’ | | |‘config t’ |
| | | |‘in-order-guarantee’ |
|‘iodShow’ | | |‘show in-order-guarentee’ |
|‘ipaddrset’ |‘set setup system’ |‘config ip’ |‘config t’ |
|or | | |‘interface mgmt0’ |
|‘ipAddrSet [-cp number] [-sw number]’ | | |“ip address 10.77.77.77 |
| | | |255.255.255.0” |
| | | |‘no shutdown’ |
|‘ipAddrShow’ |‘show setup system’ |‘show ip ethernet’ |‘show interface mgmt0’ |
|or |or |or | |
|‘ipAddrShow [-cp cp_number] | [-sw |‘show about’ |‘config ip show’ | |
|sw_number]’ |or | | |
| |‘show interface’ | | |
|‘killtelnet’ | | |‘config t’ |
| | | |‘no telnet server enable’ |
|‘login’ | |‘login’ | |
|‘logout’ |‘logout’ |‘logout’ |‘exit’ |
|‘memShow’ |‘show mem’ | |‘show system resources’ |
|‘nsAliasShow’ | | | |
|‘nsAllShow’ |‘show ns all’ | | |
|‘nsShow’ |‘show ns’ |‘show nameServer’ |‘show fcns database’ |
| | |or | |
| | |‘show nameServerExt’ | |
|‘nsStatShow’ | | | |
|‘nsZoneMember "-a|-u|PID|WWN"’ | | | |
|‘passwd’ |‘passwd’ |‘config security |‘config t’ |
|or |or |userRights’ |‘username admin password |
|‘passwd “user” |‘passwd {USER_ACCT_NAME}’ | |X’ |
|‘reboot’ |‘hardreset’ |‘maint system ipl’ |‘reload’ |
|‘savecore’ | | | |
|‘sfpShow’ | |‘show port technology’ |‘show fcs port vsan X’ |
|or | | | |
|‘sfpShow [[slotnumber/]portnumber | | | | |
|-all]’ | | | |
|‘slotOff ’ |‘set blade {SLOT_NUM} state | |‘config t’ |
| |offline’ | |‘interface fcX/X’ |
| | | |‘shutdown’ |
|‘slotOn ’ |‘set blade {SLOT_NUM} state online’| |‘config t’ |
| | | |‘interface fcX/X’ |
| | | |‘no shutdown’ |
|‘slotPowerOff ’ | | |‘config t’ |
| | | |‘poweroff module X’ |
|‘slotPowerOn ’ | | |‘config t’ |
| | | |‘no poweroff module X’ |
|‘slotShow’ | | |‘show module’ |
|‘switchBeacon mode’ |‘set beacon {on | off}’ |‘maint system beacon’ |‘config t’ |
| | | |‘interface fcX/X’ |
| | | |‘switchport beacon’ |
| | | |or |
| | | |‘no switchport beacon’ |
|‘switchDisable’ |‘set switch state offline’ |“maint system | |
| | |setOnlineState” | |
|‘switchEnable’ |‘set switch state online’ |“maint system | |
| | |setOnlineState” | |
|‘switchName [ name ]’ |‘show switch’ |‘show system’ |‘config t’ |
| |or to set… |or |‘switchname X’ |
| |‘config edit’ |‘config system name’ | |
| |‘set config switch’ | | |
|‘switchReboot’ | |‘maint system ipl’ |‘reload X’ |
| | | |(X=Supervisor Module 1 or |
| | | |2) |
|‘switchShow’ |‘show about’ |‘show switch’ |‘show interface brief’ |
| |or |or | |
| |‘show system’ |‘show system’ | |
| |or |or | |
| |‘show port’ |‘show nameserver’ | |
| | |or | |
| | |‘show port info’ | |
| | |or | |
| | |‘show port status’ | |
|‘switchShutDown’ | | | |
|‘switchStart’ | | |‘reload X’ |
| | | |(Equivalent to running |
| | | |switchShutDown and |
| | | |switchStart) |
|‘switchStatusPolicySet’ |‘set config threshold’ | | |
|‘switchStatusPolicyShow’ |‘show config threshold’ |“show thresholdAlerts | |
| | |alerts” | |
|‘switchStatusShow’ | |‘show system’ | |
| | |or | |
| | |‘show switch’ | |
|‘switchUptime’ | | |‘show system uptime’ |
|‘timeout X’ |‘set setup system’ | | |
|‘topologyShow’ |‘show topology’ |‘show fabric topology’ | |
|‘tsClockServer’ |‘set setup system’ | | |
|or | | | |
|‘tsClockServer [ipaddr]’ | | | |
|‘tsTimeZone’ |‘set setup system’ | | |
|or |or | | |
|‘tsTimeZone [hourOffset [, |‘set timezone’ | | |
|minuteOffset]]’ | | | |
|‘uptime’ |‘uptime’ | |‘show system uptime’ |
|‘version’ |‘show about’ |‘show system’ |‘show version’ |
| |or | | |
| |‘show switch’ | | |
|‘wwn’ |‘show switch’ |‘show switch’ |‘show wwn switch’ |
|or | | | |
|‘wwn [name]’ | | | |
Help on Specific Subjects
|Brocade |McData (QLogic) 4Gb Switches |McData (Legacy Switches) |Cisco |
|‘diagHelp’ |‘test ?’ |‘maint ?’ | |
|‘ficonHelp’ | |‘config ?’ | |
|‘fwHelp’ | |n/a | |
|‘help [ command ]’ |‘help {HELP_COMMAND}’ |Use “?” to get list of topics|Use “?” to get list of topics|
| | | | |
| | |and then type in topic |and then type in topic |
| | |followed by “?”. Example: |followed by “?”. Example: |
| | |‘show ?’ |‘show ?’ |
|‘licenseHelp’ |‘feature ?’ |‘config features ?’ | |
| | |or | |
| | |‘show features ?’ | |
|‘perfHelp’ | |‘perf ?’ | |
|‘routeHelp’ | |n/a | |
|‘secHelp’ |‘security ?’ |‘show security ?’ | |
| |or |or | |
| |‘securityset ?’ |‘config security ?’ | |
|‘trackChangesHelp’ | |n/a | |
|‘zoneHelp’ |‘zoning ?’ |‘config zoning ?’ | |
| |or |or | |
| |‘zoneset ?’ |‘show zoning ?’ | |
| |or | | |
| |‘zone ?’ | | |
Zoning Commands
|Brocade |McData (QLogic) 4Gb Switches |McData (Legacy Switches) |Cisco |
|‘aliAdd "aliName", “member"’ |‘alias add {ALIAS}’ | |‘member fcid X’ |
| | | |or |
| | | |‘member pwwn X’ |
| | | |or |
| | | |‘member fwwn X’ |
|‘aliCreate "aliName", "member[; |‘alias create {ALIAS}’ | |‘fcalias vsan X’|
|member ...]"’ | | | |
|‘aliDelete "aliName"’ |‘alias del {ALIAS}’ | |‘no fcalias vsan|
| |‘alias delete {ALIAS}’ | |X’ |
|‘aliRemove "aliName", "member; |‘alias remove {ALIAS} | |‘no member fcid X’ |
|member"’ |{MEMBER_LIST}’ | |or |
| | | |‘no member pwwn X’ |
| | | |or |
| | | |‘no member fwwn X’ |
|‘aliShow’ |‘alias list’ | |‘show zoneset’ |
|‘cfgAdd’ | | | |
|‘cfgCreate’ | | |‘config t’ |
| | | |“zoneset vsan|
| | | |X” |
|‘cfgDelete’ | | |“clear zone database vsan X” |
|‘cfgRemove’ | | |‘config t’ |
| | | |“zoneset vsan |
| | | |X” |
| | | |“no member ” |
|‘cfgShow’ | |‘show zoning’ |‘show zoneset’ |
| | |or |or |
| | |‘config zoning showpending’ |‘show zone status’ |
| | |or | |
| | |‘config zoning showactive’ | |
|‘cfgSize’ |‘zoning limits’ | | |
|‘zoneAdd "zoneName", |‘zone add {ZONE} {MEMBER_LIST}’|‘config zoning addZone’ |‘config t’ |
|"member;member"’ | | |“zoneset vsan |
| | | |X” |
| | | |‘zone ’ |
|‘zoneCreate "zonename", "member; |‘zone create {ZONE}‘ | |‘config t’ |
|member"’ | | |‘zone vsan X’ |
|‘zoneDelete "zonename"’ |‘zone del {ZONE} ‘ |‘config zoning deleteZone’ |‘config t’ |
| |or | |“no zone vsan X” |
| |‘zone delete {ZONE}’ | | |
|‘zoneRemove "zonename", |‘zone remove {ZONE} | |‘config t’ |
|"zoneMemberList"’ |{MEMBER_LIST}’ | |“zoneset vsan X” |
| | | |‘no zone ’ |
|‘zoneShow’ |‘zone list’ |‘show zoning’ |‘show zoneset’ |
| | | |or |
| | | |‘show zone status’ |
|‘cfgClear’ |‘reset zoning’ |“config zoning clearZoneSet” |“clear zone database vsan X” |
|‘cfgcreate "cfgName", "member"’ |‘zoneset create {ZONESET}’ | | |
|‘cfgDisable’ |‘zoneset deact’ |“config zoning deactivateZoneSet” |“no zoneset activate |
| |or | | vsan X” |
| |‘zoneset deactivate’ | | |
|‘cfgEnable’ |‘zoneset act {ZONESET}’ |“config zoning activateZoneSet” |“zoneset activate |
| |or | | vsan X” |
| |‘zoneset activate {ZONESET}’ | | |
|‘cfgSave’ |‘zoning save’ | |“copy running-config |
| | | |startup-config” |
|‘cfgSize’ | | | |
|‘cfgTransAbort’ | | | |
|‘cfgTransShow’ | |‘config zoning showpending’ |‘show zone status’ |
|‘cfgActvShow’ | |‘config zoning showactive’ |‘show zone active’ |
License Commands
|Brocade |McData (QLogic) 4Gb Switches |McData (Legacy Switches) |Cisco |
|‘licenseAdd "license"’ |‘feature add {FEATURE_KEY}’ |‘config features installKey’ |“install license |
| | | |bootflash:license-file” |
|‘licenseIdShow’ | |n/a |‘show license host-id’ |
|‘licenseRemove "license"’ | |n/a |‘clear license X’ |
|‘licenseShow’ |‘feature log’ |‘show features’ |‘show license’ |
Environmental Commands
|Brocade |McData (QLogic) 4Gb Switches |McData (Legacy Switches) |Cisco |
|‘fanDisable ’ | |n/a | |
|‘fanEnable ’ | |n/a | |
|‘fanShow’ |‘show switch’ |‘show frus’ |‘show environment fan’ |
|‘psShow’ |‘show switch’ |‘show frus’ |‘show environment power’ |
| |or | | |
| |‘show chassis’ | | |
|‘sensorShow’ | |n/a |“show tech-support module 1” |
|‘tempShow’ |‘show switch’ |n/a |‘show environment temp’ |
| |or | | |
| |‘show chassis’ | | |
Port Commands
|Brocade |McData (QLogic) 4Gb |McData (Legacy Switches) |Cisco |
| |Switches | | |
|‘portCfgDefault’ |‘set config ports’ |‘maint port reset’ | |
|or | | | |
|‘portCfgDefault [slotnumber/]portnumber’ | | | |
|‘portCfgEport [slotnumber/]portnumber, mode’ | |‘config port type X eport’ |‘config t’ |
| | | |‘interface fcX/X’ |
| | | |‘switchport mode E’ |
|‘portCfgGport [slotnumber/]portnumber, mode’ | |‘config port type X gport’ | |
| | |or | |
| | |‘config port type X fport’ | |
|‘portCfgISLMode [slotnumber/]portnumber, mode’ | |n/a | |
|‘portCfgLongDistance [slotnumber/]portnumber | |“config port extDist X | |
|[distance_level] [VC_Translation_Link_Init] | |(true/false)” | |
|[desired_distance]’ | | | |
|‘portCfgLport [slotnumber/]portnumber, mode’ | |‘config port type’ |‘config t’ |
| | | |‘interface fcX/X’ |
| | | |‘switchport mode TL’ |
|‘portCfgPersistentDisable | |‘config port blocked X | |
|[[slotnumber/]portnumber]’ | |true’ | |
|‘portCfgPersistentEnable | |‘config port blocked X | |
|[[slotnumber/]portnumber]’ | |false’ | |
|‘portCfgShow’ |‘show port X’ |‘show port config’ |‘show interface’ |
|or | |or | |
|‘portCfgShow [[slotnumber/]portnumber]’ | |‘config port show’ | |
|‘portCfgSpeed [slotnumber/]portnumber, mode’ |‘set port {PORT_NUM} |‘config port speed’ |‘config t’ |
| |{SPEED}’ | |‘interface fcX/X’ |
| | | |‘switchport speed X’ |
| | | |(X=1000 for 1gb, 2000 for |
| | | |2gb and Auto for |
| | | |auto-negotiate) |
|‘portCfgTrunkPort [slotnumber/]portnumber, mode’| |“config features | |
| | |openTrunking” | |
|‘portDisable [slotnumber/]portnumber’ |‘set port {PORT_NUM} state |“config port blocked X |‘config t’ |
| |offline’ |true” |‘interface fcX/X’ |
| | | |‘shutdown’ |
|‘portEnable [slotnumber/]portnumber’ |‘set port {PORT_NUM} state |“config port blocked X |‘config t’ |
| |online’ |false” |‘interface fcX/X’ |
| | | |‘no shutdown’ |
|‘portErrShow’ |‘show perf’ |‘perf show X’ |‘show interface’ |
| |and/or |or | |
| |‘show port X’ |‘perf errors X’ | |
| | |or | |
| | |‘perf traffic X’ | |
|‘portLogDump’ | | | |
|or | | | |
|‘portLogDump [count[, saved[, portid]]]’ | | | |
|portLogShow | | | |
|portPerfShow | | |`show interface counters |
| | | |brief’ |
|portShow | |‘perf errors X’ |‘show interface brief’ |
| | |or | |
| | |‘config port show’ | |
|portStatsClear |‘set port clear’ |‘perf clearStats X’ |“clear counters interface |
| | | |fcX/X” |
|portStatsShow | |‘perf errors X’ |‘show interface’ |
|trunkDebug | |n/a | |
|trunkShow | |‘perf openTrunking show’ |“show interface trunk vsan |
| | | |X” |
SNMP Commands
|Brocade |McData (QLogic) 4Gb Switches |McData (Legacy Switches) |Cisco |
|‘agtcfgDefault’ | |n/a | |
|‘agtcfgSet’ |‘set setup snmp’ |‘config snmp’ |‘config t’ |
| | | |‘callhome X’ |
|‘agtcfgShow’ |‘show setup snmp’ |‘config snmp show’ | |
|‘snmpMibCapSet’ | |n/a | |
Firmware Commands
|Brocade |McData (QLogic) 4Gb |McData (Legacy Switches) |Cisco |
| |Switches | | |
|‘firmwareCommit’ | |n/a | |
|‘firmwareDownload’ |‘firmware install’ |Use SANpilot or HAFM |‘install all’ |
|or | | | |
|‘firmwareDownload –s’ | | | |
|‘firmwareDownloadStatus’ | |n/a | |
|‘firmwareRestore’ |‘fallback’ |n/a | |
|‘firmwareShow’ | |‘show system’ |‘show version’ |
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related searches
- students data collection form
- methods of data collection in qualitative research
- data collection and analysis procedures
- examples of data collection methods
- data collection and analysis process
- data collection and analysis methods
- data collection and analysis pdf
- data collection methods in research
- methods of data collection pdf
- list of data collection methods
- excel data collection samples
- qualitative research data collection methods