Data Collection - Hewlett Packard Enterprise …



Data Collection

|Brocade |McData (QLogic) 4Gb Switches|McData (Legacy Switches) |Cisco |

|‘supportShow’ (pre 4.4.x) |‘show support’ |n/a (See “Collecting Initial|‘show tech-support’ |

|or | |Data”) |or |

|‘supportSave’ (later than 4.4.x) | | |‘show tech-support brief’ |

| | | |or |

| | | |‘show tech-support details’ |

|‘errClear’ | |‘show eventlog clear’ |‘clear logging logfile’ (MDS|

| | | |9120) |

|‘errDump’ | | |‘show logging’ |

|‘errShow’ |‘show port X’ |‘show eventlog’ |‘attach module X’ |

| | | |“show port-config internal |

| | | |link-events” |

| | | |or |

| | | |‘show logging’ |

|‘syslogdIpAdd ’ |‘set setup system’ | |‘config t’ |

| | | |“logging server ip-address |

| | | |facility local1” |

|‘syslogdIpRemove ’ |‘set setup system’ | |‘config t’ |

| | | |‘no logging server’ |

|‘syslogdIpShow’ |‘show setup system’ | |‘show logging server’ |

|‘supportShowCfgEnable ’ | |n/a | |

|‘supportShowCfgDisable ’ | |n/a | |

|‘supportShowCfgShow’ | |n/a | |

Overall Switch Status Commands

|Brocade |McData (QLogic) 4Gb Switches |McData (Legacy Switches) |Cisco |

|‘bladeBeacon slotnumber [mode]’ | | |‘config t’ |

| | | |‘interface fcX/X’ |

| | | |‘switchport beacon’ |

| | | |or |

| | | |‘no switchport beacon’ |

|‘bladeDisable slotnumber’ | | |‘config t’ |

| | | |‘interface fcX/X shutdown’|

|‘bladeEnable slotnumber’ | | |‘config t’ |

| | | |“interface fcX/X no |

| | | |shutdown” |

|‘bladePropShow [[--slot] slotnumber]’ | | |‘show interface fcX/X’ |

|‘chassisName [name]’ | |‘show system’ |‘show switchname’ |

| | |or | |

| | |‘config system name’ | |

|‘chassisShow’ | |‘show frus’ |‘show hardware’ |

|‘configDefault’ |‘config cancel’ |‘maint system resetConfig’|‘write erase’ |

| | | |‘reload’ |

|‘configDownload’ |‘config restore’ |n/a (Must be replaced |“copy |

| | |manually from collected |t |

| | |data) |nvram:startup-config” |

|‘configShow’ |‘config list’ |Use the various ‘show’ and|‘show running-config’ |

| | |‘config’ commands |or |

| | | |‘show startup-config’ |

|‘configUpload’ |‘config backup’ |n/a (See “Collecting |“copy nvram:startup-config|

| | |Initial Data” above) |t” |

|‘configure’ |‘config edit {CONFIG_NAME}’ |‘config’ |‘config terminal’ |

| |or | | |

| |‘config edit’ | | |

| |‘set config switch’ | | |

|‘date’ |‘date’ |‘config system date’ |‘show clock’ |

|or |or | |or |

|‘date "mmddhhmmyy"’ |‘date {MMDDhhmmCCYY} ‘ | |‘clock set’ |

|‘dlsReset’ | | |‘config t’ |

| | | |‘no fspf enable vsan X’ |

|‘dlsSet’ | | |‘config t’ |

| | | |‘fspf enable vsan X’ |

|‘dlsShow’ | | |‘show fspf’ |

|‘fabricPrincipal [ -fhq ][ mode ]’ |‘config edit’ | |‘config t’ |

| |‘set config switch’ | |‘fcdomain priority x vsan |

| | | |X’ |

| | | |(Note: switch priority can|

| | | |be set to a number from |

| | | |1-254 with 1 being the |

| | | |highest. The switch with |

| | | |the highest priority |

| | | |becomes principal.) |

|‘fabricShow’ | | |“show fcdomain domain-list|

| | | |vsan X” |

|‘fastboot’ |‘reset’ |‘maint system ipl’ | |

| ‘haDump’ | | | |

|‘haShow’ | | |“show system redundancy |

| | | |status” |

|‘help’ |? or ‘help’ |? |? |

|‘history’ (or ‘h’) |‘history’ | | |

|‘historyLastShow’ | | | |

|‘historyShow’ | | | |

|‘httpCfgShow’ | | | |

|‘ifModeSet ’ | | | |

|‘ifModeShow ’ |‘show setup system’ | |‘show ip route’ |

| |or | |or |

| |‘show about’ | |‘show interface mgmt0’ |

| |or | | |

| |‘show interface’ | | |

|‘interopMode [mode]’ |‘config edit’ |‘show switch’ |‘show running’ |

| |‘set config switch’ |or |or |

| |and to display interopmode: |‘config switch |‘show vsan X’ |

| |‘show config switch’ |interopMode’ | |

|‘iodReset’ | | |‘config t’ |

| | | |‘no in-order-guarantee’ |

|‘iodSet’ | | |‘config t’ |

| | | |‘in-order-guarantee’ |

|‘iodShow’ | | |‘show in-order-guarentee’ |

|‘ipaddrset’ |‘set setup system’ |‘config ip’ |‘config t’ |

|or | | |‘interface mgmt0’ |

|‘ipAddrSet [-cp number] [-sw number]’ | | |“ip address 10.77.77.77 |

| | | |255.255.255.0” |

| | | |‘no shutdown’ |

|‘ipAddrShow’ |‘show setup system’ |‘show ip ethernet’ |‘show interface mgmt0’ |

|or |or |or | |

|‘ipAddrShow [-cp cp_number] | [-sw |‘show about’ |‘config ip show’ | |

|sw_number]’ |or | | |

| |‘show interface’ | | |

|‘killtelnet’ | | |‘config t’ |

| | | |‘no telnet server enable’ |

|‘login’ | |‘login’ | |

|‘logout’ |‘logout’ |‘logout’ |‘exit’ |

|‘memShow’ |‘show mem’ | |‘show system resources’ |

|‘nsAliasShow’ | | | |

|‘nsAllShow’ |‘show ns all’ | | |

|‘nsShow’ |‘show ns’ |‘show nameServer’ |‘show fcns database’ |

| | |or | |

| | |‘show nameServerExt’ | |

|‘nsStatShow’ | | | |

|‘nsZoneMember "-a|-u|PID|WWN"’ | | | |

|‘passwd’ |‘passwd’ |‘config security |‘config t’ |

|or |or |userRights’ |‘username admin password |

|‘passwd “user” |‘passwd {USER_ACCT_NAME}’ | |X’ |

|‘reboot’ |‘hardreset’ |‘maint system ipl’ |‘reload’ |

|‘savecore’ | | | |

|‘sfpShow’ | |‘show port technology’ |‘show fcs port vsan X’ |

|or | | | |

|‘sfpShow [[slotnumber/]portnumber | | | | |

|-all]’ | | | |

|‘slotOff ’ |‘set blade {SLOT_NUM} state | |‘config t’ |

| |offline’ | |‘interface fcX/X’ |

| | | |‘shutdown’ |

|‘slotOn ’ |‘set blade {SLOT_NUM} state online’| |‘config t’ |

| | | |‘interface fcX/X’ |

| | | |‘no shutdown’ |

|‘slotPowerOff ’ | | |‘config t’ |

| | | |‘poweroff module X’ |

|‘slotPowerOn ’ | | |‘config t’ |

| | | |‘no poweroff module X’ |

|‘slotShow’ | | |‘show module’ |

|‘switchBeacon mode’ |‘set beacon {on | off}’ |‘maint system beacon’ |‘config t’ |

| | | |‘interface fcX/X’ |

| | | |‘switchport beacon’ |

| | | |or |

| | | |‘no switchport beacon’ |

|‘switchDisable’ |‘set switch state offline’ |“maint system | |

| | |setOnlineState” | |

|‘switchEnable’ |‘set switch state online’ |“maint system | |

| | |setOnlineState” | |

|‘switchName [ name ]’ |‘show switch’ |‘show system’ |‘config t’ |

| |or to set… |or |‘switchname X’ |

| |‘config edit’ |‘config system name’ | |

| |‘set config switch’ | | |

|‘switchReboot’ | |‘maint system ipl’ |‘reload X’ |

| | | |(X=Supervisor Module 1 or |

| | | |2) |

|‘switchShow’ |‘show about’ |‘show switch’ |‘show interface brief’ |

| |or |or | |

| |‘show system’ |‘show system’ | |

| |or |or | |

| |‘show port’ |‘show nameserver’ | |

| | |or | |

| | |‘show port info’ | |

| | |or | |

| | |‘show port status’ | |

|‘switchShutDown’ | | | |

|‘switchStart’ | | |‘reload X’ |

| | | |(Equivalent to running |

| | | |switchShutDown and |

| | | |switchStart) |

|‘switchStatusPolicySet’ |‘set config threshold’ | | |

|‘switchStatusPolicyShow’ |‘show config threshold’ |“show thresholdAlerts | |

| | |alerts” | |

|‘switchStatusShow’ | |‘show system’ | |

| | |or | |

| | |‘show switch’ | |

|‘switchUptime’ | | |‘show system uptime’ |

|‘timeout X’ |‘set setup system’ | | |

|‘topologyShow’ |‘show topology’ |‘show fabric topology’ | |

|‘tsClockServer’ |‘set setup system’ | | |

|or | | | |

|‘tsClockServer [ipaddr]’ | | | |

|‘tsTimeZone’ |‘set setup system’ | | |

|or |or | | |

|‘tsTimeZone [hourOffset [, |‘set timezone’ | | |

|minuteOffset]]’ | | | |

|‘uptime’ |‘uptime’ | |‘show system uptime’ |

|‘version’ |‘show about’ |‘show system’ |‘show version’ |

| |or | | |

| |‘show switch’ | | |

|‘wwn’ |‘show switch’ |‘show switch’ |‘show wwn switch’ |

|or | | | |

|‘wwn [name]’ | | | |

Help on Specific Subjects

|Brocade |McData (QLogic) 4Gb Switches |McData (Legacy Switches) |Cisco |

|‘diagHelp’ |‘test ?’ |‘maint ?’ | |

|‘ficonHelp’ | |‘config ?’ | |

|‘fwHelp’ | |n/a | |

|‘help [ command ]’ |‘help {HELP_COMMAND}’ |Use “?” to get list of topics|Use “?” to get list of topics|

| | | | |

| | |and then type in topic |and then type in topic |

| | |followed by “?”. Example: |followed by “?”. Example: |

| | |‘show ?’ |‘show ?’ |

|‘licenseHelp’ |‘feature ?’ |‘config features ?’ | |

| | |or | |

| | |‘show features ?’ | |

|‘perfHelp’ | |‘perf ?’ | |

|‘routeHelp’ | |n/a | |

|‘secHelp’ |‘security ?’ |‘show security ?’ | |

| |or |or | |

| |‘securityset ?’ |‘config security ?’ | |

|‘trackChangesHelp’ | |n/a | |

|‘zoneHelp’ |‘zoning ?’ |‘config zoning ?’ | |

| |or |or | |

| |‘zoneset ?’ |‘show zoning ?’ | |

| |or | | |

| |‘zone ?’ | | |

Zoning Commands

|Brocade |McData (QLogic) 4Gb Switches |McData (Legacy Switches) |Cisco |

|‘aliAdd "aliName", “member"’ |‘alias add {ALIAS}’ | |‘member fcid X’ |

| | | |or |

| | | |‘member pwwn X’ |

| | | |or |

| | | |‘member fwwn X’ |

|‘aliCreate "aliName", "member[; |‘alias create {ALIAS}’ | |‘fcalias vsan X’|

|member ...]"’ | | | |

|‘aliDelete "aliName"’ |‘alias del {ALIAS}’ | |‘no fcalias vsan|

| |‘alias delete {ALIAS}’ | |X’ |

|‘aliRemove "aliName", "member; |‘alias remove {ALIAS} | |‘no member fcid X’ |

|member"’ |{MEMBER_LIST}’ | |or |

| | | |‘no member pwwn X’ |

| | | |or |

| | | |‘no member fwwn X’ |

|‘aliShow’ |‘alias list’ | |‘show zoneset’ |

|‘cfgAdd’ | | | |

|‘cfgCreate’ | | |‘config t’ |

| | | |“zoneset vsan|

| | | |X” |

|‘cfgDelete’ | | |“clear zone database vsan X” |

|‘cfgRemove’ | | |‘config t’ |

| | | |“zoneset vsan |

| | | |X” |

| | | |“no member ” |

|‘cfgShow’ | |‘show zoning’ |‘show zoneset’ |

| | |or |or |

| | |‘config zoning showpending’ |‘show zone status’ |

| | |or | |

| | |‘config zoning showactive’ | |

|‘cfgSize’ |‘zoning limits’ | | |

|‘zoneAdd "zoneName", |‘zone add {ZONE} {MEMBER_LIST}’|‘config zoning addZone’ |‘config t’ |

|"member;member"’ | | |“zoneset vsan |

| | | |X” |

| | | |‘zone ’ |

|‘zoneCreate "zonename", "member; |‘zone create {ZONE}‘ | |‘config t’ |

|member"’ | | |‘zone vsan X’ |

|‘zoneDelete "zonename"’ |‘zone del {ZONE} ‘ |‘config zoning deleteZone’ |‘config t’ |

| |or | |“no zone vsan X” |

| |‘zone delete {ZONE}’ | | |

|‘zoneRemove "zonename", |‘zone remove {ZONE} | |‘config t’ |

|"zoneMemberList"’ |{MEMBER_LIST}’ | |“zoneset vsan X” |

| | | |‘no zone ’ |

|‘zoneShow’ |‘zone list’ |‘show zoning’ |‘show zoneset’ |

| | | |or |

| | | |‘show zone status’ |

|‘cfgClear’ |‘reset zoning’ |“config zoning clearZoneSet” |“clear zone database vsan X” |

|‘cfgcreate "cfgName", "member"’ |‘zoneset create {ZONESET}’ | | |

|‘cfgDisable’ |‘zoneset deact’ |“config zoning deactivateZoneSet” |“no zoneset activate |

| |or | | vsan X” |

| |‘zoneset deactivate’ | | |

|‘cfgEnable’ |‘zoneset act {ZONESET}’ |“config zoning activateZoneSet” |“zoneset activate |

| |or | | vsan X” |

| |‘zoneset activate {ZONESET}’ | | |

|‘cfgSave’ |‘zoning save’ | |“copy running-config |

| | | |startup-config” |

|‘cfgSize’ | | | |

|‘cfgTransAbort’ | | | |

|‘cfgTransShow’ | |‘config zoning showpending’ |‘show zone status’ |

|‘cfgActvShow’ | |‘config zoning showactive’ |‘show zone active’ |

License Commands

|Brocade |McData (QLogic) 4Gb Switches |McData (Legacy Switches) |Cisco |

|‘licenseAdd "license"’ |‘feature add {FEATURE_KEY}’ |‘config features installKey’ |“install license |

| | | |bootflash:license-file” |

|‘licenseIdShow’ | |n/a |‘show license host-id’ |

|‘licenseRemove "license"’ | |n/a |‘clear license X’ |

|‘licenseShow’ |‘feature log’ |‘show features’ |‘show license’ |

Environmental Commands

|Brocade |McData (QLogic) 4Gb Switches |McData (Legacy Switches) |Cisco |

|‘fanDisable ’ | |n/a | |

|‘fanEnable ’ | |n/a | |

|‘fanShow’ |‘show switch’ |‘show frus’ |‘show environment fan’ |

|‘psShow’ |‘show switch’ |‘show frus’ |‘show environment power’ |

| |or | | |

| |‘show chassis’ | | |

|‘sensorShow’ | |n/a |“show tech-support module 1” |

|‘tempShow’ |‘show switch’ |n/a |‘show environment temp’ |

| |or | | |

| |‘show chassis’ | | |

Port Commands

|Brocade |McData (QLogic) 4Gb |McData (Legacy Switches) |Cisco |

| |Switches | | |

|‘portCfgDefault’ |‘set config ports’ |‘maint port reset’ | |

|or | | | |

|‘portCfgDefault [slotnumber/]portnumber’ | | | |

|‘portCfgEport [slotnumber/]portnumber, mode’ | |‘config port type X eport’ |‘config t’ |

| | | |‘interface fcX/X’ |

| | | |‘switchport mode E’ |

|‘portCfgGport [slotnumber/]portnumber, mode’ | |‘config port type X gport’ | |

| | |or | |

| | |‘config port type X fport’ | |

|‘portCfgISLMode [slotnumber/]portnumber, mode’ | |n/a | |

|‘portCfgLongDistance [slotnumber/]portnumber | |“config port extDist X | |

|[distance_level] [VC_Translation_Link_Init] | |(true/false)” | |

|[desired_distance]’ | | | |

|‘portCfgLport [slotnumber/]portnumber, mode’ | |‘config port type’ |‘config t’ |

| | | |‘interface fcX/X’ |

| | | |‘switchport mode TL’ |

|‘portCfgPersistentDisable | |‘config port blocked X | |

|[[slotnumber/]portnumber]’ | |true’ | |

|‘portCfgPersistentEnable | |‘config port blocked X | |

|[[slotnumber/]portnumber]’ | |false’ | |

|‘portCfgShow’ |‘show port X’ |‘show port config’ |‘show interface’ |

|or | |or | |

|‘portCfgShow [[slotnumber/]portnumber]’ | |‘config port show’ | |

|‘portCfgSpeed [slotnumber/]portnumber, mode’ |‘set port {PORT_NUM} |‘config port speed’ |‘config t’ |

| |{SPEED}’ | |‘interface fcX/X’ |

| | | |‘switchport speed X’ |

| | | |(X=1000 for 1gb, 2000 for |

| | | |2gb and Auto for |

| | | |auto-negotiate) |

|‘portCfgTrunkPort [slotnumber/]portnumber, mode’| |“config features | |

| | |openTrunking” | |

|‘portDisable [slotnumber/]portnumber’ |‘set port {PORT_NUM} state |“config port blocked X |‘config t’ |

| |offline’ |true” |‘interface fcX/X’ |

| | | |‘shutdown’ |

|‘portEnable [slotnumber/]portnumber’ |‘set port {PORT_NUM} state |“config port blocked X |‘config t’ |

| |online’ |false” |‘interface fcX/X’ |

| | | |‘no shutdown’ |

|‘portErrShow’ |‘show perf’ |‘perf show X’ |‘show interface’ |

| |and/or |or | |

| |‘show port X’ |‘perf errors X’ | |

| | |or | |

| | |‘perf traffic X’ | |

|‘portLogDump’ | | | |

|or | | | |

|‘portLogDump [count[, saved[, portid]]]’ | | | |

|portLogShow | | | |

|portPerfShow | | |`show interface counters |

| | | |brief’ |

|portShow | |‘perf errors X’ |‘show interface brief’ |

| | |or | |

| | |‘config port show’ | |

|portStatsClear |‘set port clear’ |‘perf clearStats X’ |“clear counters interface |

| | | |fcX/X” |

|portStatsShow | |‘perf errors X’ |‘show interface’ |

|trunkDebug | |n/a | |

|trunkShow | |‘perf openTrunking show’ |“show interface trunk vsan |

| | | |X” |

SNMP Commands

|Brocade |McData (QLogic) 4Gb Switches |McData (Legacy Switches) |Cisco |

|‘agtcfgDefault’ | |n/a | |

|‘agtcfgSet’ |‘set setup snmp’ |‘config snmp’ |‘config t’ |

| | | |‘callhome X’ |

|‘agtcfgShow’ |‘show setup snmp’ |‘config snmp show’ | |

|‘snmpMibCapSet’ | |n/a | |

Firmware Commands

|Brocade |McData (QLogic) 4Gb |McData (Legacy Switches) |Cisco |

| |Switches | | |

|‘firmwareCommit’ | |n/a | |

|‘firmwareDownload’ |‘firmware install’ |Use SANpilot or HAFM |‘install all’ |

|or | | | |

|‘firmwareDownload –s’ | | | |

|‘firmwareDownloadStatus’ | |n/a | |

|‘firmwareRestore’ |‘fallback’ |n/a | |

|‘firmwareShow’ | |‘show system’ |‘show version’ |

................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download