Arris Sign Systems CSI Specifications



SECTION 10 14 00

INTERIOR SIGNAGE

Display hidden notes to specifier by using “Tools”/”Options”/“View”/”Hidden Text” or

“More Commands”/”Display”/”Hidden Text”

** NOTE TO SPECIFIER **

1

1. SECTION INCLUDES

** NOTE TO SPECIFIER ** Delete items below not required for project.

A.

2. RELATED SECTIONS

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required.

A.

B. Section 10 13 00 - Directories.

C. Section 10 14 26 – Post and Panel / Pylon Signage.

D. Section 10 14 33 – Illuminated Panel Signage.

E. Section 10 14 36 - Non-Illuminated Panel Signage.

3. REFERENCES

** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.

A.

B. Department of Justice, Office of the Attorney General, "Americans with Disabilities Act", Public Law 101-336, (ADA).

C. 2010 Standards for Accessible Design (SAD): The updated ADAAG (ADA Accessibility Guidelines), effective on March 15, 2011 and made mandatory on March 16, 2012.

4. SYSTEM DESCRIPTION

A. Signage under this section is intended to include items for identification, direction, control, and information of building where installed as complete integrated system from a single manufacturer.

B. ADA design requirements:

1. Provide signage that conforms to the requirements of all regulatory agencies holding jurisdiction.

2. Comply with all applicable provisions of the 2010 Standards for Accessible Design (the updated ADA Accessibility Guidelines, ADAAG - ), effective in March 2011. Requirements include, but are not limited to the following:

a. Tactile copy must be all upper case and raised at least 1/32”. Tactile characters must be sans serif, not italic, not oblique, script or highly decorative.

b. The stroke width of the upper case “I” has to be 15% of the letter height or less. The character width of the uppercase “O” must be between 55% and 100% of the height of the corresponding uppercase “I”.

c. The copy height for tactile information must be between 5/8” and 2”. If separate visual characters are provided, raised characters can be ½” and need not contrast with the background.

d. The distance between characters on tactile copy must be a minimum of 1/8” and a maximum of 4 times the character stroke width. These distances are measured between the closest points of adjacent characters.

e. Spacing between lines of tactile copy needs to be a minimum of 135% and a maximum of 170% of the corresponding upper case “I” height (measured from baseline to baseline).

f. Braille must be Grade II and positioned directly below the corresponding raised characters. If text is multi-lined, Braille is placed below the entire boyd of text and separated 3/8” from any other tactile characters and 3/8” minimum from raised borders and decorative elements.

g. Visual characters and symbols, and their background, are to have a non-glare finish. The color of raised characters must contrast as much as possible with their background to make sure signs are more legible for persons with low vision.

h. Pictograms, selected from International Standards, are to be located within a 6” vertical void and accompanying text descriptions are to be located directly below the pictogram.

5. SUBMITTALS

A. Submit under provisions of Section 01300.

B. Product Data: Manufacturer's data sheets on each product to be used, including:

1. Manufacturer's product literature indicating units and designs selected.

2. Evidence of manufacturer's computerized data retrieval program for tracking of project for sign typography, message strip requirements and other pertinent data from schedule input to final computerized typography on finished product.

3. Preparation instructions and recommendations.

4. Storage and handling requirements and recommendations.

5. Installation methods.

C. Samples: One full size sign sample illustrating the design, construction, colors, typestyles, mounting method and other details as specified. Provide sample in small size sign.

NOTE TO SPECIFIER ** Delete provision not required.

1.

2. Samples will not be returned for use in Project.

D. Shop Drawings:

1. Indicate materials, sizes, configurations, and applicable substrate mountings.

2. Typography sample for message strips and headers copy.

NOTE TO SPECIFIER ** Option. Delete if not required.

3.

NOTE TO SPECIFIER ** Option. Delete if not required.

4.

E. Signage Schedule: Complete with location of each sign and the required copy/text.

F. Sign Program Maintenance Plan:

1. Manufacturer shall provide details of software and system of pre-perforated and color coated paper sign inserts allowing client to update and maintain signage graphics in-house.

2. Manufacturer shall provide details of an Online Reordering & Maintenance Application whereby the client can submit sign reorders online and store relevant project information such as sign type drawings, message schedules and product instructions.

G. Contract close out:

1. Furnish appropriate checklist for aiding in reordering after Date of Substantial Completion. Maintain computer schedule program for five years for ordering new signage required by Owner.

2. Maintenance data and cleaning requirements for exterior surfaces.

NOTE TO SPECIFIER ** Manufacturer has available software program for personal computers - pc, called "SignWord Pro" enabling end user to produce graphics on insert or sign face. Information in main catalog, Call manufacturer directly at listed telephone number for more info. Delete if not required.

3.

NOTE TO SPECIFIER ** Option. Delete if not required.

6.

A. Manufacturer Qualifications:

1. Work required under this section from manufacturer regularly engaged in work of this type and scope for a minimum of 5 years.

2. Maintain computer link between schedule input and computerized typography production.

B. Installer Qualifications: Trained and authorized by manufacturer for installations of required scope and product.

** NOTE TO SPECIFIER ** Include a mock-up if the project size and/or quality warrant taking such a precaution. The following is one example of how a mock-up on a large project might be specified. When deciding on the extent of the mock-up, consider all the major different types of work on the project.

C.

1. Finish areas designated by Architect.

2. Do not proceed with remaining work until workmanship, graphics, and installation are approved by Architect.

3. Refinish mock-up as required to produce acceptable work.

7. DELIVERY, STORAGE & HANDLING

A. Package signs to prevent damage during shipment, handling, storage and installation. Products are to remain in their original packaging (unless otherwise specified) until removal is necessary for installation.

B. If installation site is not ready for signage upon delivery, store signs in a dry, air-conditioned environment.

C. Handle signage in accordance with manufacturer’s instructions.

D. Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction.

8. PROJECT CONDITIONS

A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.

9. SEQUENCING AND SCHEDULING

A. Schedule system installation after room finishes and fixtures have been completed.

10. WARRANTY

A. Product Warranty: Provide manufacturer’s warranty against defects in materials and workmanship for a period of one year.

2 PRODUCTS

1. ACCEPTABLE MANUFACTURERS

A. Signage shall be manufactured by APCO Graphics, Inc. (a.k.a. APCO Signs or APCO USA), at 388 Grant Street SE, Atlanta, GA 30312.

2. ACCEPTABLE PRODUCT

A. FullView Modular Sign & Display System.

** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.

B.

C. Requests for substitutions will be considered in accordance with provisions of Section 01600.

3. SYSTEM REQUIREMENTS

A. General:

1. Sign system shall feature solutions for all required sign types, including but not limited to wall mounted personnel signs, work station personnel signs, primary room identification, directories, directionals, overhead signs, projection wall signs, free standing signs, restroom signs, regulatory and information signs, stair signs and changeable slide conference room signs. All signs within the system must feature the same family of components and/or convey a uniform look throughout.

B. Features:

1. Sign Frames: Sign frame assemblies shall be comprised of aluminum extrusions with a core material rigid enough to support the sign’s display/insert material.

2. Sign Depth: No wall mounted signs, excluding any decorative backers, should feature a depth greater than 5/8”. Wall mounted signs 17”w or less shall feature a maximum depth of 7/16”.

3. Updatability: Signs must allow for easy updating of message inserts for all signtypes and must offer an option of front-loading/re-loading of insert panels.

4. Tamper Resistance: System must offer an option for a concealed locking method to increase level of tamper resistance.

5. Mounting: Signs must be able to accommodate installation via fully concealed mechanical fasteners.

C. Graphics and Typography: As selected from manufacturer’s standards. Reference sign drawings.

D. Colors and Finishes: As selected from manufacturer’s standards. Reference sign drawings.

E. ADA Compliance: Sign system shall comply with all applicable provisions of the 2010 Standards for Accessible Design (the updated ADA Accessibility Guidelines, ADAAG), effective in March 2011. This includes requirements regarding which sign types require Braille/tactile features, character heights, raised character spacing, raised character stroke width, color contrast and installation locations / mounting heights within the facility.

F. Materials and Construction:

1. Sign assemblies shall be comprised of an extruded aluminum frame and an inner core rigid enough to properly support the display/insert material. Overall depth of all frames 17”w or less shall not exceed 7/16”. Frames must allow for front loading/re-loading of insert panels and must offer an option for a concealed locking method to increase tamper resistance.

2. Aluminum frame extrusions shall be extruded in the USA.

3. ADA-compliant components shall be APCO’s DP-Tactile process direct-print, UV-cured, 1/32” thick tactile characters and fully domed Braille printed on an acrylic or aluminum plaque.

4. Graphic Inserts/Panels are as per sign drawings and should be easily updatable without the need to replace the entire sign assembly.

5. Fasteners: Signs shall be able to accommodate fully concealed mechanical

fasteners.

** NOTE TO SPECIFIER ** If using APCO’s Design Studio 2 to design the sign system and/or if the FullView signs will feature decorative backers, use Section 2.5 below and use Section 2.6 only as needed for additional sign types or mounting options.

4.

A. Low-Profile FullView Signs as Designed Using APCO’s Online Design Studio 2 (Reference 2.5 Following)

B. Low-Profile FullView Signs as Custom Specified and Designed

(Reference 2.6 Following)

5. FULLVIEW SIGNS AS DESIGNED USING APCO’S ONLINE DESIGN STUDIO 2

Reference drawings for colors, finishes, sizes and details. Additional signtypes may be added in Section 2.6 following.

A. Basic System Description: Low profile aluminum FullView sign frames with a wide range of graphics inserts and displays. Larger directional and directory signs are of APCO’s Accord15 modular system, aesthetically compatible with FullView. Reference drawings for colors, finishes, typestyles and other details. Reference sign schedule for exact messages.

B. FullView Assembly Type

1. E-Series (FVE) with Flex-In / Flex-Out, 1/16” thick acrylic inserts.

C. Edge Profile Shape

** NOTE TO SPECIFIER ** Delete the profiles that do not apply.

1. Square: FVES

2. Radius: FVER

3. Contour: FVEC

D. Frame Finish

1. Natural Satin Anodized

2. Painted Finish

a. Manufacturer’s Standard: ________________

b. Custom Color: _________________________

E. Core SignTypes

Other/additional signtypes may also be included within this project.

** NOTE TO SPECIFIER ** Delete any signtypes that do not apply.

See signage schedule and/or drawings for details.

1. SignType FV_-A4 Personnel Sign – Small. Nominal 3”h x 8-1/2”w ID.

2. SignType FV_-B12 Room/Personnel ID. Nominal 6-1/2”h x 8-1/2”w ID.

3. SignType FV_-B17 Room ID – User Lettered. Nominal 8-1/2”h x 6”w ID.

4. SignType FV_-R1 Restroom ID. Nominal 8-1/2”h x 6”w ID.

5. SignType FV_-B18 Room ID – User Lettered. Nominal 8-1/2”h x 8-1/2”w ID.

6. SignType FV_-C1.R Patient Information. Nominal 14-3/8”h x 7-1/8”w ID.

7. SignType FV_-B22 Conference Room ID. Nominal 9-1/8”h x 8-1/2”w ID.

8. SignType FV_-B20 Room ID. Nominal 8-1/2”h x 8-1/2”w ID.

9. SignType FV_-B28 Room ID – Large. Nominal 15-1/4”h x 8-1/2”w ID.

10. SignType FV_E3 Fire Evacuation. Nominal 12-3/4”h x 11”w ID.

11. SignType FV_R.P1 Overhead Wall Projection. Nominal 8-1/2”h x 8-1/2”w ID.

12. SignType FV_D5 Directional w/ Paper Insert. Nominal 20-1/4”h x 11”w ID.

13. SignType FV_F6 Stair ID. Nominal 8-1/2”h x 6”w ID.

14. SignType FV_B4 Tactile Room ID – Small. 4”h x 8-1/2”w ID.

15. SignType FV_D.O1 Overhead Ceiling. Nominal 6”h x 36”w ID.

16. SignType FV_D10 Directional w/ Aluminum Inserts. Nominal 27-3/4”h x 17”w.

17. SignType FV_K5 Directory w/ InsertSlots. Nominal 18-1/4”h x 14”w ID.

F. Decorative Backer Shape(s)

NOTE TO SPECIFIER ** Delete shapes that are not required.

1.

2. ARC 1

3. ARC 2

4. ARC 3

5. SCROLL 1

6. SCROLL 2

7. SCROLL 3

8. ORTHO 1

9. ORTHO 2

10. ORTHO 3

G. Decorative Backer Finishes

NOTE TO SPECIFIER ** Delete finishes that are not required.

1.

2. Direct Print Wood Pattern: ______________________ (Top/Bottom Layer)

3. Direct Print Stone Pattern: ______________________ (Top/Bottom Layer)

4. Translucent – ACF Cool Frost: (Top Layer)

5. Translucent – w/ Direct Print Pattern: _________________ (Top/Bottom Layer)

6. Direct Print Pattern/Image: _______________________ (Top/Bottom Layer)

7. Solid Color – Painted: ___________________________ (Top/Bottom Layer)

H. Graphics / Typography

1. Type Sizes: Selected from manufacturer's standard sizes indicated in SCHEDULE for particular units; meet ADA requirements for letter proportions and sizes.

2. Typography: Reference signage schedule and individual signtype drawings for details. Font(s) selected from manufacturer’s standards unless otherwise specified. All text and graphics shall be a true representation of the typeface(s) and/or graphics specified. Letter spacing and interline spacing shall be set by the manufacturer.

NOTE TO SPECIFIER ** Delete typeface(s) not required.

a.

b. Futura Book (FUB)

c. Arial (AR)

d. Frutiger-Normal (F55)

e. Myriad Pro (MP)

f. Typeface(s) as indicated in SCHEDULES Article and Drawings.

NOTE TO SPECIFIER ** Delete type code(s) not required.

3.

4. Type Code(s): Initial caps.

5. Type Code(s): Combination.

6. Type Code(s): Indicated in SCHEDULES Article.

7. Imprint Colors: Selected by Architect from manufacturer's standard direct-print colors and indicated in SCHEDULE; color contrast background colors in accord with ADA requirements.

8. Copy/Message List: Indicated in SCHEDULE.

9. Reference drawings and Signage Schedule for details.

10. All text and graphics shall be a true representation of typeface(s) and/or graphics specified.

6. FULLVIEW SIGNS AS CUSTOM SPECIFIED AND DESIGNED

Reference signtype drawings for colors, finishes, sizes and details. Reference signage schedule for graphics/copy specifications.

A. Standard Assembly FullView – Vertical Configuration: FV(V)

1. Frame Shape

a. Square: FVS(V)

b. Radius: FVR(V)

c. Contour: FVC(V)

2. Frame Finish

a. Natural Satin Anodized

b. Painted Finish – Manufacturer’s Standard Color: _______________

c. Painted Finish – Custom Color: ____________________________

3. Frame Sizes Selected from Manufacturer’s Standards.

4. Insert/Display Components to Include:

NOTE TO SPECIFIER ** Delete inserts that are not required.

a.

b. FVOP(V) 1/8” Thick Painted Acrylic Plaque with Direct-Print Graphics

c. FV341A-DPT(V) 1/8” Thick Acrylic with UV-Cured, Direct-Print Raised Characters & Braille.

d. FV241A-DPT-D(V) 1/16” Thick Acrylic ADA Bottom Plaque with UV-Cured, Direct-Print Raised Characters & Braille, with Aluminum Divider

e. FV341A-DPT(V) 1/8” Thick Acrylic ADA Bottom Plaque with UV-Cured, Direct-Print Raised Characters & Braille, without Aluminum Divider.

f. FVSL(V) 1-1/8”h Aluminum Slider Band.

g. FVDW(V) Direct-Print Decorative Wood Pattern Bottom Plaque

i. Manufacturer’s Standard: _________________________

ii. Other: _________________________

h. FVDM(V) Decorative Metal Bottom Plaque

i. DMP3 MicroPerf

ii. DMS4 Dimpled

5. Mounting/Installation Types to Include

a. FV(V)CT Desk/Countertop Mounting with Formed Aluminum Stand

b. FV(V)PC Workstation Mounting with Formed Aluminum Panel Clip

c. FV(V)WM Surface Wall Mount

i. Vinyl Tape (VT)

ii. Concealed Mechanical Fasteners (MF)

iii. Vinyl Tape and Silicone Adhesive (SA)

d. FV(V)PWM Projection Wall Mount with Aluminum CMTM Bracket.

B. Standard Assembly FullView – Horizontal Configuration: FV(H)

1. Frame Shape

a. Square: FVS(H)

b. Radius: FVR(H)

c. Contour: FVC(H)

2. Frame Finish

a. Natural Satin Anodized

b. Painted Finish – Manufacturer’s Standard Color: _______________

c. Painted Finish – Custom Color: ____________________________

3. Frame Sizes Selected from Manufacturer’s Standards.

4. Insert/Display Components to Include:

a. FVCL(H) 1/8” Thick Non-Glare Acrylic Lens with Subsurface ADO (APCO Digital Output) or Laser Printed Insert.

b. FVOP(H) 1/8” Thick Acrylic Plaque with Direct-Print Graphics

c. FV341A-DPT(H) 1/8” Thick Acrylic with UV-Cured, Direct-Print Raised Characters & Braille.

5. Mounting/Installation Types to Include

a. FV(H)PC Workstation Mounting with Formed Aluminum Panel Clip

b. FV(H)WM Surface Wall Mount

i. Vinyl Tape (VT)

ii. Concealed Mechanical Fasteners (MF)

iii. Vinyl Tape and Silicone Adhesive (SA)

c. FV(H)CMF Flush Ceiling Mount

d. FV(H)CMW Wire Suspended Ceiling Mount

C. Top-Access Assembly FullView – Vertical Configuration: FVTA(V)

1. Frame Shape

a. Square: FVS(V)

b. Radius: FVR(V)

c. Contour: FVC(V)

2. Frame Finish

a. Natural Satin Anodized

b. Painted Finish – Manufacturer’s Standard Color: _______________

c. Painted Finish – Custom Color: ____________________________

3. Frame Sizes Selected from Manufacturer’s Standards.

(Maximum Top-Access frame size is 17”h x 11”w)

4. Insert/Display Components to Include:

a. FVCL(V)TA Thumb-Slot Non-Glare Acrylic Lens with SubSurface ADO (APCO Digital Output) Insert.

b. FVCL(V)TA Thumb-Slot Non-Glare Acrylic Lens with SubSurface Laser Printed Insert.

c. FVADA-DPT(V) Flatbed Direct-Print or Painted Band* with APCO’s DP-Tactile Process Direct-Print UV-Cured Raised Characters & Braille, Applied to Non-Glare Acrylic Lens. (*For non-metallic colors, band is printed directly onto non-glare lens. For metallic colors, a painted band is applied to a non-glare lens.)

d. FVSL(V) 1-1/8”h Aluminum Slider Band.

e. FV241A-DPT-D(V) 1/16” Thick Acrylic ADA Bottom Plaque with UV-Cured, Direct-Print Raised Characters & Braille, with Aluminum Divider

f. FV341A-DPT(V) 1/8” Thick Acrylic ADA Bottom Plaque with UV-Cured, Direct-Print Raised Characters & Braille, without Aluminum Divider.

g. FVDW(V) Direct-Print Decorative Wood Pattern Bottom Plaque

i. Manufacturer’s Standard: _________________________

ii. Other: _________________________

FVDM(V) Decorative Metal Bottom Plaque

i. DMP3 MicroPerf

ii. DMS4 Dimpled

5. Mounting/Installation Types to Include

a. FVTA(V)PC Workstation Mounting with Formed Aluminum Panel Clip

b. FVTA(V)WM Surface Wall Mount

i. Vinyl Tape (VT)

ii. Vinyl Tape and Silicone Adhesive (SA)

c. FVTA(V)CT Desk/Countertop Mounting with Formed Aluminum Stand

D. Inner-Access FullView Assembly – Vertical Configuration: FVIA(V)

1. Frame Shape

a. Square: FVS(V)

b. Radius: FVR(V)

c. Contour: FVC(V)

2. Frame Finish

a. Natural Satin Anodized

b. Painted Finish – Manufacturer’s Standard Color: _______________

c. Painted Finish – Custom Color: ____________________________

3. Frame Sizes Selected from Manufacturer’s Standards.

(Maximum Top-Access frame size is 17”h x 11”w)

4. Insert/Display Components to Include:

a. FVCL(V)IA 1/16” Thick Non-Glare Acrylic Lens with SubSurface ADO (APCO Digital Output) or Laser Printed Insert.

b. FVADA-DPT(V) Flatbed Direct-Print or Painted Band* with APCO’s DP-Tactile Process Direct-Print UV-Cured Raised Characters & Braille, Applied to Non-Glare Acrylic Lens. (*For non-metallic colors, band is printed directly onto non-glare lens. For metallic colors, a painted band is applied to a non-glare lens.)

c. FVSL(V) 1-1/8”h Aluminum Slider Band.

d. FV241A-DPT-D(V) 1/16” Thick Acrylic ADA Bottom Plaque with UV-Cured, Direct-Print Raised Characters & Braille, with Aluminum Divider

e. FV341A-DPT(V) 1/8” Thick Acrylic ADA Bottom Plaque with UV-Cured, Direct-Print Raised Characters & Braille, without Aluminum Divider.

f. FVDW(V) Direct-Print Decorative Wood Pattern Bottom Plaque

i. Manufacturer’s Standard: _________________________

ii. Other: _________________________

FVDM(V) Decorative Metal Bottom Plaque

i. DMP3 MicroPerf

ii. DMS4 Dimpled

5. Mounting/Installation Types to Include

a. FVIA(V)PC Workstation Mounting with Formed Aluminum Panel Clip

b. FVIA(V)WM Surface Wall Mount

i. Vinyl Tape (VT)

ii. Vinyl Tape & Silicone Adhesive (SA)

c. FVIA(V)CT Desk/Countertop Mounting with Formed Aluminum Stand

E. E-Series Assembly FullView – Vertical Configuration: FVE(V)

1. Frame Shape

a. Square: FVES(V)

b. Radius: FVER(V)

c. Contour: FVEC(V)

2. Frame Finish

a. Natural Satin Anodized

b. Painted Finish – Manufacturer’s Standard Color: _______________

c. Painted Finish – Custom Color: ____________________________

3. Frame Sizes Selected from Manufacturer’s Standards.

(Maximum E-Series frame size is 17”h x 11”w)

4. Insert/Display Components to Include:

a. FVECL(V) 1/16” Thick Non-Glare Acrylic Lens with SubSurface ADO (APCO Digital Output) or Laser Printed Insert.

b. FVEOP(V) 1/16” Thick Painted Acrylic with Direct-Print Graphics.

c. FVE241A-DPT(V) 1/16” Thick Acrylic ADA Plaque with UV-Cured, Direct-Print Raised Characters & Braille.

d. FVADA-DPT(V) Flatbed Direct-Print or Painted Band* with APCO's DP-Tactile Process Direct-Print UV-Cured Raised Characters & Braille, Applied to Non-Glare Acrylic Lens. (*For non-metallic colors, band is printed directly onto non-glare lens. For metallic colors, a painted band is applied to a non-glare lens.)

e. FVDB ¼” Aluminum Divider Bar for E-Series.

5. Mounting/Installation Types to Include

a. FVE(V)PC Workstation Mounting with Formed Aluminum Panel Clip

b. FVE(V)WM Surface Wall Mount

i. Vinyl Tape (VT)

ii. Concealed Mechanical Fasteners (MF)

iii. Vinyl Tape and Silicone Adhesive (SA)

F. Large Assembly FullView – Vertical Configuration: FVL(V)

1. Frame Shape

a. Square: FVLS(V)

b. Radius: FVLR(V)

2. Frame Finish

a. Natural Satin Anodized

b. Painted Finish – Manufacturer’s Standard Color: _______________

c. Painted Finish – Custom Color: ____________________________

3. Frame Sizes

a. 22”h x 22”w (FVL__2222(V))

b. 28”h x 22”w (FVL__2822(V))

c. 24”h x 24”w (FVL__2424(V))

d. 28”h x 24”w (FVL__2824(V))

e. 32”h x 24”w (FVL__3224(V))

f. 36”h x 24”w (FVL__3624(V))

g. 24”h x 25”w 2-Column (FVL__24MC1(V))

h. 24”h x 38”w 3-Column (FVL__24MC2(V))

i. 24”h x 37”w 2-Column (FVL__24MC3(V))

j. 36”h x 25”w 2-Column (FVL__36MC1(V))

k. 36”h x 38”w 3-Column (FVL__36MC2(V))

l. 36”h x 37”w 2-Column (FVL__36MC3(V))

m. 28-1/16”h x 25”w 2-Column with Header (FVL__28MCH1(V))

n. 28-1/16”h x 38”w 3-Column with Header (FVL__28MCH2(V))

o. 28-1/16”h x 37”w 2-Column with Header (FVL__28MCH3(V))

p. 40-1/16”h x 25”w 2-Column with Header (FVL__40MCH1(V))

q. 40-1/16”h x 38”w 3-Column with Header (FVL__40MCH2(V))

r. 40-1/16”h x 37”w 2-Column with Header (FVL__40MCH3(V))

4. Mounting/Installation Types to Include

a. FVL(V)WM Surface Wall Mount

i. Concealed Mechanical Fasteners (MF)

G. Large Assembly FullView – Horizontal Configuration: FVL(H)

1. Frame Shape

a. Square: FVLS(H)

b. Radius: FVLR(H)

2. Frame Finish

a. Natural Satin Anodized

b. Painted Finish – Manufacturer’s Standard Color: _______________

c. Painted Finish – Custom Color: ____________________________

3. Frame Sizes

a. 22”h x 22”w (FVL__2222(H))

b. 22”h x 28”w (FVL__2228(H))

c. 22”h x 36”w (FVL__2236(H))

d. 24”h x 24”w (FVL__2424(H))

e. 24”h x 36”w (FVL__2436(H))

f. 24”h x 48”w with 4-Side Capture Feature (FVL__2448(H)4C)

g. 36”h x 36”w with 4-Side Capture Feature (FVL__3636(H)4C)

h. 36”h x 42”w with 4-Side Capture Feature (FVL__3642(H)4C)

i. 36”h x 48”w with 4-Side Capture Feature (FVL__3648(H)4C)

j. 36”h x 54”w with 4-Side Capture Feature (FVL__3654(H)4C)

k. 36”h x 60”w with 4-Side Capture Feature (FVL__3660(H)4C)

H. FullView Stanchion: FS300-FV

1. Stanchion Finish

a. Natural Satin Anodized

b. Painted Finish – Manufacturer’s Standard Color: _______________

c. Painted Finish – Custom Color: ____________________________

2. Frame Finish

a. Natural Satin Anodized

b. Painted Finish – Manufacturer’s Standard Color: _______________

c. Painted Finish – Custom Color: ____________________________

3. Stanchion Type

a. FS300 Incline Display

b. FS301 Vertical Display – Single Sided

c. FS301.2 Vertical Display – Double Sided

4. Display Type

a. FullView Standard Assembly – Vertical Configuration (FV(V))

b. FullView Standard Assembly – Horizontal Configuration (FV(H))

c. FullView Top-Access Assembly – Vertical Configuration (FVTA(V))

d. FullView Inner-Access Assembly – Vertical Configuration (FVIA(V))

e. FullView E-Series Assembly – Vertical Configuration (FVE(V))

5. Display/Frame Size

a. 8-1/2”h x 11”w

b. 11”h x 8-1/2”w

c. 11”h x 17”w

d. 17”h x 11”w

I. FullView Kiosk: FVKSK

1. Kiosk Finish

a. Natural Satin Anodized

b. Painted Finish – Manufacturer’s Standard Color: _______________

c. Painted Finish – Custom Color: ____________________________

2. Kiosk Size

a. 48”h x 11”w (FVKSK4811)

b. 60”h x 11”w (FVKSK6011)

c. 60”h x 17”w (FVKSK6017)

d. 66”h x 17”w (FVKSK6617)

e. 72”h x 17”w (FVKSK7217)

f. 66”h x 22”w (FVKSK6622)

g. 72”h x 22”w (FVKSK7222)

3. Kiosk Display Components to Include:

a. 1/8” thick non-glare acrylic lens with subsurface ADO (APCO Digital Output) insert (FVKSCL(V))

b. 1/8” thick acrylic with Direct-Print decorative wood pattern (FVKSDW)

i. Manufacturer’s Standard: _________________________

ii. Other: _________________________

J. Graphics

1. Type Sizes: Selected from manufacturer's standard sizes indicated in SCHEDULE for particular units; meet ADA requirements for letter proportions and sizes.

2. Typography: Reference signage schedule and drawings for details. Font(s) selected from manufacturer’s standards unless otherwise specified. All text and graphics shall be a true representation of the typeface(s) and/or graphics specified. Letter spacing and interline spacing shall be set by the manufacturer.

NOTE TO SPECIFIER ** Delete typeface(s) not required.

a.

b. Futura Book (FUB)

c. Arial (AR)

d. Frutiger-Normal (F55)

e. Myriad Pro (MP)

f. Typeface(s) as indicated in SCHEDULES Article and Drawings.

NOTE TO SPECIFIER ** Delete type code(s) not required.

3.

4. Type Code(s): Initial caps.

5. Type Code(s): Combination.

6. Type Code(s): Indicated in SCHEDULES Article.

7. Imprint Colors: Selected by Architect from manufacturer's standard direct-print colors and indicated in SCHEDULE; color contrast background colors in accord with ADA requirements.

8. Copy/Message List: Indicated in SCHEDULE.

9. Reference drawings and Signage Schedule for details.

10. All text and graphics shall be a true representation of typeface(s) and/or graphics specified.

7. FABRICATION

A. Fabricate units as per specifications and details indicated on reviewed drawings.

B. All fabrication must take place in the USA.

C. Include product instructions sheets for installation and removal/replacement of insert components.

3 EXECUTION

1. EXAMINATION

A. Do not begin installation until substrates have been properly prepared.

B. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.

2. PREPARATION

A. Clean surfaces thoroughly prior to installation.

B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

3. INSTALLATION

A. Install products in accordance with manufacturer’s instructions, in locations and with mounting methods as specified in sign and location drawings.

B. Square, plumb and level all installed products.

C. Install all signage in accordance with the 2010 Standard for Accessible Design (SAD) effective in March 2011, and any applicable local regulations and/or codes.

D. Upon completion of the work, sign installer shall remove any unused products, materials, packaging and debris from the installation site.

4. CLEANING

A. Clean all exposed surface not more than 48 hours prior to Date of Substantial Completion in accordance with manufacturer’s written cleaning instructions.

5. PROTECTION

A. Protect installed products until completion of project.

B. Touch-up, repair or replace damaged products before Substantial Completion.

6. SIGN SCHEDULES

A. Refer to Signage Schedule and Drawings for sizes, locations, sign types, layouts, typestyle specifications, sign text/copy and sign graphics.

B.

END OF SECTION

................
................