NPP Power Co.,Ltd. NPD12-250Ah 12V250Ah
NPP Power Co.,Ltd.
NPD12-250Ah 12V250Ah
Specifications Nominal Voltage
Rated capacity (20 hour rate) Length
Dimensions
Width Height
Total Height
Approx. Weight
12V 250Ah 520?2mm(20.47inch) 268?2mm(10.55inch) 220?2mm(8.66inch) 243?2mm(9.57inch) 74.5kg(163.9lbs)?3%
Outer dimensions (mm)
Terminal Type (mm)
16
M8?16 T16
5
Characteristics
Capacity (25)
20HR(10.8V) 3HR(10.8V) 1HR(10.5V)
Terminal type
250Ah 189Ah 140Ah
T16
Internal resistance (Fully charged,25)
Approx. 2.6m
Capacity affected by temperature
(20HR)
40 25 0 -15
Self-discharge (25)
3 months 6 months 12 months
Nominal operating temperature
Operating temperature
range
Discharge Charge Storage
102% 100% 85% 65% Remaining Capacity:91% Remaining Capacity:82% Remaining Capacity:65%
2 5 ?3( 7 7 ?5)
-15~50(5~122) -10~50(14~122) -20~50(-4~122)
13.50 to 13.80V Float charging voltage(25) Temperature compensation:
-18mV/
14.50 to 15.00V Cyclic charging voltage(25) Temperature compensation:
-30mV/
Maximum charging current Maximum discharge current Designed floating life(20)
75A 1500A(5 sec.)
10years
Construction
Component Positive plate Raw material Lead dioxide
Negative plate Container Cover Separator
Lead
ABS
ABS
AGM
Constant Current Discharge Characteristics Unit:A(25,77)
Electrolyte Sulfuric acid
Safety valve Rubber
Terminal Copper
F.V/Time 15min 30min 60min
2h
3h
4h
5h
6h
8h
10h
20h
9.60V
428
256
158
93.2
67.1
53.6
45.8
39.8
31.5
26.0
13.8
9.90V
418
251
155
92.6
66.7
53.3
45.5
39.6
31.3
25.9
13.7
10.2V
403
243
151
91.8
66.3
52.9
45.2
39.3
31.1
25.8
13.7
10.5V
389
238
147
90.4
65.8
52.5
44.9
39.0
30.9
25.7
13.6
10.8V
368
229
142
88.1
63.8
51.0
43.5
37.8
29.9
25.5
13.5
Constant Power Discharge Characteristics Unit:W(25,77)
F.V/Time 15min 30min 60min
2h
3h
4h
5h
6h
8h
10h
20h
9.60V
4704
2875
1797
1079
789
630
541
470
374
310
165
9.90V
4591
2818
1770
1073
785
626
538
468
372
309
165
10.2V
4422
2732
1725
1063
779
622
534
464
369
308
164
10.5V
4271
2666
1671
1047
774
618
530
461
367
307
163
10.8V
4045
2568
1617
1021
750
599
515
447
356
304
162
Note: The above characteristics data can be obtained within three charge or discharge cycles.
NPP Power Co.,Ltd. NPD12-250Ah 12V250Ah
Capacity (%)
Voltage (V)
13.0 12.0 11.0 10.0 9.00 8.00
3C 2C
1C 0.6C
0.2C 0.1C 0.05C 0.3C
1 2 3 5 10 20 30 60 2 3 5 10 20 30 min
Discharge time
120 100
0.05C 0.1C
80
0.25C
60 1C
40
20
0 -20 -10 0
10 20 30 40 50
Temperature ()
Floating life on Temperature
15
Life (years)
10 5
2.30V/Cell
0.5
10
20
30
40
50
60
Temperature()
The relationship for OCV and Capacity (25)
Open Circuit Voltage (V)
13.5
13.0 (25 C/77 F)
12.5 12.0
11.5
11.0
0
20
40
60
80
100
Residual Capacity (%)
IS O1 IS O 9
001 :20 08
4000 :20 04
Voltage (V)
Capacity (%)
Charged Volume Current Voltage
(%) 140
(CA) (V)
120 0.25 15.0
100 0.20 14.0
80
0.15 13.0
60
0.10
40
12.0
50% Discharge 100% Discharge
Charged volume
Charge voltage
20
0.05 11.0
Charging current
0
0
0 2 4 6 8 10 12 14 16 18 20 Charging time(hours)
Self-discharge characteristics
100
90
80
70
60
40 C
50
30 C
20 C
40
02
4
6
8 10 12 14 16
Storage time(months)
Cycle life on D.O.D (25)
Capacity (%)
120 100
80 60 40 20
100% D.O.D.
50% D.O.D.
30% D.O.D.
0 200 400 600 800 1000 1200 1400 1600 Number of cycles (cycles)
The relationship for Charging voltage and Temperature
15.6 15.0 14.4 13.8 13.2
Cycle Use Floating Use
-10
0
10
20
30
40
Temperature()
50
60
................
................
In order to avoid copyright disputes, this page is only a partial summary.
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Related download
- white paper deep cycle battery storage
- batteries and inverters first national battery
- deep cycle series east penn manufacturing
- deep cycle and starter batteries usa material
- npp power co ltd npd12 250ah 12v250ah
- charging flooded lead acid batteries for long battery life
- how to correctly connect deep cycle
- deep cycle battery amperes hour ah rating
- renogy deep cycle gel battery 12 volt
- commercial deep cycle batteries crown battery