City of Oviedo - Florida Building Department Service-PDCS ...



Valencia CollegePermit Application Guidelines All permit application packages must be complete prior to acceptance. A complete application package shall include the following:Building Permit Application completed, signed and notarized. Application must include correct address and complete parcel I.D. number.Copy of the contractor’s license issued by the State of Florida (if contractor is applicant).A site specific notarized power of attorney shall be required from the licensed contractor ifhe/she appoints an employee of his/her company to sign the permit application as the contractor.Certificate of insurance indicating General Liability insurance coverage and naming the Valencia College as certificate holder.Certificate of insurance indicating Worker’s Compensation insurance coverage and naming the Valencia College as certificate holder.Three (3) paper sets of signed and sealed building construction plans.Two (2) copies of the manufacturer’s installation instructions for the following products: windows, doors, roofing materials, engineered lumber products, glass blocks, soffit materials and siding.Three (3) sets of completed and signed energy calculations (signed/sealed if required by Florida Statute or code).State of Florida Division of Hotel and Restaurant approval (if applicable).Florida Department of Environmental Protection Notice of Asbestos Renovation or Demolition (if applicable).State of Florida Notification on Gas Tanks (if applicable).THE CONSTRUCTION DOCUMENTS MUST INCLUDE, AT A MINIMUM, THE FOLLOWING:SITE PLANAll parking and accessible routesAccessible parking space(s) and signage detailsAccessible entrancesAccessible ramps, handrails, guardrails, curb cuts and detailsAll required building exits accessible (not less than 60% if all are not required exits)Areas of rescue assistanceAccessible signageFire accessVehicle loadingDriving/turning radiusFire hydrant/water supply/post indicator valve (PIV)Location of septic systems (if applicable)Setbacks/fire separation (assumed property lines)Utility lines (water, sewer, irrigationMeters and backflow devicesBUILDING PLANConstruction documents shall indicate code edition being appliedPage size minimum 11” x 17”Plans to minimum 1/8“scaleAll pages numbered and labeledPlans signed/sealed and dated by a Florida Design Professional as applicableDesigner information: name, address, registration # on all pagesReference the currently adopted code editionsWind design data required on drawings per FBC 1603.1.4 to meet 129 mph ultimate design wind speed for risk category I buildings, 139 mph ultimate design wind speed for risk category II buildings and 149 mph ultimate design wind speed for risk category III and IV buildings Ultimate design wind speed (Vult)Nominal design wind speed (Vasd)Risk categoryExposure categoryEnclosure classificationInternal pressure coefficientComponent and cladding design wind pressures in terms of psfStructural Calculations, if necessary Threshold Inspection Plan (for threshold buildings)All areas dimensioned and use notedCorridorsShafts and elevator hoistwaysStair location/guardrails/handrailsPartition denotations and scheduleDoor locations, sizes, door and hardware scheduleWindow locations, sizes and scheduleTempered glass locationsAttic ventilation and accessAir barrier requirementsInterior finish ratings and scheduleLight and ventilationSanitationElevatorsEscalatorsLiftsRoof coveringsConstruction type design criteria:Type of construction denoted (per table 503)Occupancy group classification denoted for building and rooms/areasGross square footage – Net square footage calculationsBuilding heightPercentage of exterior openings calculationsClassification of hazard of contents (if applicable) Structural Design Criteria:Ultimate design wind speed (Vult)Nominal design wind speed (Vasd)Risk categoryExposure categoryEnclosure classificationInternal pressure coefficientComponent and cladding design wind pressures in terms of psfStructural Calculations, if necessary Floor loads – psfStair loads – psfRoof loads – psfBalcony loads – psfCorridor loads – psfStorage loads – psfMaterials to be reviewed shall at a minimum include the following:Wood / grade – speciesSteel / type - grade AluminumConcretePlasticGlassMasonryGypsum board and plasterInsulating (mechanical)RoofingInsulationAlternate materialsStructural:Signed and sealed soil report with a positive conclusion requiredCompaction requirementsFoundation locations, dimensions and depth specifiedFoundation denotations, schedules and detailsReinforcing steel, amount, size, grade, spacing, and lap specifiedFooting dowel locationsMaximum filled cell spacingEmbedment’sSlab thickness and reinforcementVapor barrierTermite protectionRelieving arch steel details at pipe penetrationsBrick ledge detail including flashing and weep hole size and spacingBuilding materials usedLintel locations, denotations and scheduleExterior and interior structural wall sectionsColumnsTie beamsStructural steel size, type, connectionsFraming details and fasteningLoad path connectorsFloor deck and fasteningWall sheathing and fasteningRoof deck and fasteningStair constructionWindow and door details, including design pressure of openingsFastening details for windows and doors, (type, length, and quantity)Exterior mounted mechanical units fastening methods to meet wind loadRoof and floor framing, truss layout, connector scheduleFire Protection Requirements:Fire separation requirements for corridors, elevators, stairways, floors & shaftsOccupancy separation requirementsTenant separation requirementsFire resistant protection details for type of constructionRated requirements for walls, floor-ceiling and roof-ceiling assembliesDesign numbers and details for all rated assembliesDesign numbers and details for all rated penetrationsRated door and hardware schedulesFire blocking and draft stoppingCalculated fire resistanceInterior finishes (flame spread/smoke development)Life Safety:Occupant load calculations and egress capacitiesSpecial occupancy requirementsEgress planNumber of exitsCapacity of exitsArrangement of exitsTravel distance to exits/common path of travelStairs construction/geometry and protectionHorizontal exits/exit passagewaysIllumination of exitsExit signsEmergency lightingEnclosuresHandrailsGuardrailsRampsEarly warning systems schematicSmoke control systems schematicStair pressurization systems schematicExtinguishing requirementsAreas of rescue assistanceAccessibility Building:Door sizes, hardware scheduleVertical accessibilityAccessible route dimensionsManeuvering clearancesHi-Lo drinking fountainEquipment clear floor space/reach rangesAreas of rescue assistanceSignageATM machinesAccessibility Restrooms/Bathrooms:Turning radiusRequired floor space for fixturesFixture and equipment mounting dimensionsAdaptabilityAccessible requirements for special occupancies in addition to general requirements will also be reviewed.PLUMBING PLANPlumbing plans submittedPiping materialsPiping supportsDetermine minimum plumbing fixtures required based on occupant load calculated per FBC 1004Water distribution diagramWater hammer arrestorsPlumbing drain, waste and vent riser diagramGrease trap detailGrease trap Health Dept. report on existingInterceptorsRoof drains/calculations for flat roofsBackflow preventionMedical gasOxygen systemsEnvironmental requirementsWater Heaters:T & P drainAir gapPan drainThermal expansion deviceHeat trapsMounting platformGAS PLANType of gasGas pressureAppliances schedule and BTU’sChimneys and VentsCombustion airLP tank size and location (above or below grade)Protection requirementsGas Riser Diagram:Pipe typePipe sizingTotal developed lengthSegment lengthsAppliance locationsShut-offs valvesMECHANICAL PLANMechanical plans submittedEnergy calculationsDuct systems and sizingDuct work clearances at mechanical room (4” minimum)Duct supportsMeans for balancing HVAC systemDiffusers (size and direction)CFM requirementsVentilationCombustion airOutdoor air calculationsBalanced return airMake-up airEquipment location and working clearances ( 30” wide by 36” deep, 6’ high minimum)Condensate piping and disposalRequired platforms and catwalksRoof mounted equipment (including equipment and curb anchorage)Details and specificationsEquipment sizing calculationsEquipment specificationsJoint sealing methods and product specificationAir balance tableRated penetrations - fire damper details and manufacturer’s installation instructionsMeans for automatic fan shutdownKitchen hood, duct plans, fire suppression and specificationsBathroom exhaust systemsSpecial exhaust systemsChimneys, fireplaces and ventsOther appliancesBoilersRefrigerationBathroom ventilationLaboratoryELECTRICAL PLANMaximum available fault current at serviceAIC rating of equipmentVoltage and phase of electrical systemLoad calculationElectrical service riser diagram indicating overcurrent protection sizes, conductor and conduit types and sizes, number of service disconnecting means, grounding electrode system: bonded to the foundation steel, structural steel, metal piping, size and type, separately derived system or not? (solid neutral or switching)Transformer sizes and types if usedPanel schedules and ratingsPower planPanel locations and working clearancesLighting planDevice legendWiring methods and materialsFeeders and branch circuits, conduit sizes and typesGrounding conductorsExit lightsEmergency lightingEgress lightingSignage and disconnecting means locationGenerator type: emergency or standbyRemote annunciationLoad shed (if necessary)Required receptacle outletsGFCI’sEquipmentSpecial occupanciesEmergency systemsCommunication systemsLow voltageFIRE PROTECTION/FIRE SUPPRESSION PLANEarly warning smoke evacuation and controlSprinkler design criterion (separate permit required)Fire alarm design criterion (separate permit required)Pre-engineered systemsRiser diagramStandpipes ................
................

In order to avoid copyright disputes, this page is only a partial summary.

Google Online Preview   Download